Hemodynamic, ventilatory and gasometric evaluation of an experimental bronchopleural fistula
Oliveira, Douglas Guimaraes de; Toneloto, Maria Gabriela Cavicchia; Moreira, Marcos Mello; Bustorff-Silva, Joaquim Murray; Souza, Gabriel Franco de; Martins, Luiz Claudio; Kosour, Carolina; Dragosavac, Desanka; Falcão, Antonio Luis Eiras.
Afiliação
  • Oliveira, Douglas Guimaraes de; State University of Campinas. Faculty of Medical Sciences. BR
  • Toneloto, Maria Gabriela Cavicchia; State University of Campinas. Faculty of Medical Sciences. BR
  • Moreira, Marcos Mello; State University of Campinas. Faculty of Medical Sciences. BR
  • Bustorff-Silva, Joaquim Murray; State University of Campinas. Faculty of Medical Sciences. BR
  • Souza, Gabriel Franco de; State University of Campinas. Faculty of Medical Sciences. BR
  • Martins, Luiz Claudio; State University of Campinas. Faculty of Medical Sciences. BR
  • Kosour, Carolina; State University of Campinas. Faculty of Medical Sciences. BR
  • Dragosavac, Desanka; State University of Campinas. Faculty of Medical Sciences. BR
  • Falcão, Antonio Luis Eiras; State University of Campinas. Faculty of Medical Sciences. BR
Acta cir. bras ; 30(1): 1-5, 01/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-735712
Biblioteca responsável: BR1.1
ABSTRACT

PURPOSE:

To investigate the hemodynamic and ventilatory changes associated with the creation of an experimental bronchopleural fistula (BPF) treated by mechanical ventilation and thoracic drainage with or without a water seal.

METHODS:

Six large white pigs weighing 25 kg each which, after general anesthesia, underwent endotracheal intubation (6mm), and mechanically ventilation. Through a left thoracotomy, a resection of the lingula was performed in order to create a BPF with an output exceeding 50% of the inspired volume. The chest cavity was closed and drained into the water sealed system for initial observation of the high output BPF.

RESULTS:

Significant reduction in BPF output and PaCO2 was related after insertion of a water-sealed thoracic drain, p< 0.05.

CONCLUSION:

Insertion of a water-sealed thoracic drain resulted in reduction in bronchopleural fistula output and better CO2 clearance without any drop in cardiac output or significant changes in mean arterial pressure. .
Assuntos


Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Doenças Pleurais / Fístula Brônquica / Ventilação Pulmonar / Modelos Animais de Doenças / Hemodinâmica Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Acta cir. bras Assunto da revista: CIRURGIA GERAL / Procedimentos Cir£rgicos Operat¢rios Ano de publicação: 2015 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: State University of Campinas/BR

Texto completo: Disponível Coleções: Bases de dados internacionais Base de dados: LILACS Assunto principal: Doenças Pleurais / Fístula Brônquica / Ventilação Pulmonar / Modelos Animais de Doenças / Hemodinâmica Tipo de estudo: Estudo prognóstico Limite: Animais Idioma: Inglês Revista: Acta cir. bras Assunto da revista: CIRURGIA GERAL / Procedimentos Cir£rgicos Operat¢rios Ano de publicação: 2015 Tipo de documento: Artigo / Documento de projeto País de afiliação: Brasil Instituição/País de afiliação: State University of Campinas/BR
...