Your browser doesn't support javascript.
loading
Effect of high frequency transcutaneous electrical nerve stimulation on viability of random skin flap in rats / Efeito da estimulação elétrica nervosa transcutânea em alta freqüência na viabilidade do retalho cutâneo randômico em ratos
Liebano, Richard Eloin; Abla, Luiz Eduardo Felipe; Ferreira, Lydia Masako.
Afiliação
  • Liebano, Richard Eloin; Universidade Federal de São Paulo. Escola Paulista de Medicina. São Paulo. Brasil
  • Abla, Luiz Eduardo Felipe; Universidade Federal de São Paulo. Escola Paulista de Medicina. São Paulo. Brasil
  • Ferreira, Lydia Masako; Universidade Federal de São Paulo. Escola Paulista de Medicina. São Paulo. Brasil
Acta cir. bras. ; 21(3): 133-138, May-June 2006. tab, graf
Artigo em Inglês | VETINDEX | ID: vti-14440
Biblioteca responsável: BR68.1
Localização: BR68.1
RESUMO

OBJETIVO:

Avaliar o efeito da Estimulação Elétrica Nervosa Transcutânea (TENS) em alta freqüência na viabilidade do retalho cutâneo randômico em ratos.

MÉTODOS:

Foram utilizados 75 ratos da linhagem Wistar. O retalho cutâneo apresentava 10 x 4 cm, sendo que entre o mesmo e a área doadora foi realizada a interposição de uma barreira plástica. Após o procedimento operatório todos os animais permaneceram anestesiados por mais uma hora com os eletrodos posicionados na base do retalho e submetidos ao tratamento de acordo com seus respectivos grupos. Este procedimento se repetiu nos outros dois dias subseqüentes. G1 simulação da TENS, G2 TENS (f = 80 Hz e I = 5 mA), G3 TENS (f = 80 Hz e I = 10 mA), G4 TENS (f = 80 Hz e I = 15 mA), G5 TENS (f = 80 Hz e I = 20 mA).

RESULTADOS:

A porcentagem média de área de necrose foi de 43,11, 34,65, 49,44, 23,52, 45,10 nos grupos 1, 2, 3, 4 e 5 respectivamente.

CONCLUSÃO:

Os animais estimulados com amplitude de 15 mA apresentaram menor área de necrose quando comparados ao grupo controle e a Estimulação Elétrica Nervosa Transcutânea foi eficiente no aumento de viabilidade do retalho cutâneo randômico em ratos.(AU)
ABSTRACT

PURPOSE:

To determine the effect of high frequency Transcutaneous Electrical Nerve Stimulation (TENS) on viability of random skin flap in rats.

METHODS:

The sample of this study was 75 Wistar rats. The skin flap measured 10 x 4 cm and a plastic barrier was interposed between the flap and donor site. After the operative procedure, animals of all groups were maintained anesthetized one more hour with electrodes positioned in the base of the flap and submitted to treatment according of their respective group. This procedure was repeated on the two subsequent days. G1 sham stimulation (control), G2 TENS (f = 80 Hz and I = 5 mA), G3 TENS (f = 80 Hz and I = 10 mA), G4 TENS (f = 80 Hz and I = 15 mA), G5 TENS (f = 80 Hz and I = 20 mA).

RESULTS:

The average percentage of necrotic area was 43,11, 34,65, 49,44, 23,52, 45,10 in groups 1, 2, 3, 4 and 5 respectively.

CONCLUSION:

The amplitude of 15 mA presented a lower necrotic area than control group and Transcutaneous Electrical Nerve Stimulation was efficient in increasing the random skin flap viability.(AU)
Assuntos

Texto completo: Disponível Base de dados: VETINDEX Assunto principal: Retalhos Cirúrgicos / Estimulação Elétrica Nervosa Transcutânea / Ratos Wistar Limite: Animais Idioma: Inglês Revista: Acta cir. bras. Ano de publicação: 2006 Tipo de documento: Artigo Instituição/País de afiliação: Universidade Federal de São Paulo/Brasil
Texto completo: Disponível Base de dados: VETINDEX Assunto principal: Retalhos Cirúrgicos / Estimulação Elétrica Nervosa Transcutânea / Ratos Wistar Limite: Animais Idioma: Inglês Revista: Acta cir. bras. Ano de publicação: 2006 Tipo de documento: Artigo Instituição/País de afiliação: Universidade Federal de São Paulo/Brasil
...