Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Mater Sci Mater Med ; 32(12): 148, 2021 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-34862915

RESUMO

There is continued focus on the development of new biomaterials and associated biological testing methods needed to reduce the time taken for their entry to clinical use. The application of Raman spectroscopy to the study of individual cells that have been in contact with biomaterials offers enhanced in vitro information in a potentially non-destructive testing regime. The work presented here reports the Raman spectral analysis of discreet U-2 OS bone cells after exposure to hydroxyapatite (HA) coated titanium (Ti) substrates in both the as-deposited and thermally annealed states. These data show that cells that were in contact with the bioactive HA surface for 7 days had spectral markers similar to those cultured on the Ti substrate control for the same period. However, the spectral features for those cells that were in contact with the annealed HA surface had indicators of significant differentiation at day 21 while cells on the as-deposited surface did not show these Raman changes until day 28. The cells adhered to pristine Ti control surface showed no spectral changes at any of the timepoints studied. The validity of these spectroscopic results has been confirmed using data from standard in vitro cell viability, adhesion, and proliferation assays over the same 28-day culture period. In this case, cell maturation was evidenced by the formation of natural bone apatite, which precipitated intracellularly for cells exposed to both types of HA-coated Ti at 21 and 28 days, respectively. The properties of the intracellular apatite were markedly different from that of the synthetic HA used to coat the Ti substrate with an average particle size of 230 nm, a crystalline-like shape and Ca/P ratio of 1.63 ± 0.5 as determined by SEM-EDX analysis. By comparison, the synthetic HA particles used as a control had an average size of 372 nm and were more-rounded in shape with a Ca/P ratio of 0.8 by XPS analysis and 1.28 by SEM-EDX analysis. This study shows that Raman spectroscopy can be employed to monitor single U-2 OS cell response to biomaterials that promote cell maturation towards de novo bone thereby offering a label-free in vitro testing method that allows for non-destructive analyses.


Assuntos
Osso e Ossos/citologia , Durapatita/farmacologia , Análise de Célula Única , Análise Espectral Raman , Titânio/farmacologia , Materiais Biocompatíveis , Biomarcadores , Linhagem Celular , Humanos , Teste de Materiais
2.
Emerg Med J ; 30(2): 157-8, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22423169

RESUMO

OBJECTIVE: Is a watch and wait approach safe in asymptomatic patients presenting to the emergency department with a confirmed oesophageal coin on x-ray? METHODS: A retrospective case note review for children <16 years attending with a confirmed oesophageal coin on x-ray over a 7-year period (1 January 2004 to 31 December 2010). RESULTS: 89% (33/37) of coins in asymptomatic patients, who were conservatively managed, had passed spontaneously on repeat chest x-ray up to 18 h later. No patient who was discharged with a middle or lower oesophageal coin required a GA and no child who was treated conservatively developed any complications. CONCLUSION: In the UK asymptomatic children, with no history of tracheal or oesophageal disease and a confirmed oesophageal coin on x-ray should undergo a period of observation up to 18 h. This can be safely undertaken at home, followed by a repeat x-ray in the emergency department.


Assuntos
Esôfago , Corpos Estranhos/terapia , Adolescente , Algoritmos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Estudos Retrospectivos , Reino Unido
3.
Int J Pharm ; 631: 122477, 2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36509226

RESUMO

Implantable drug-eluting devices that provide therapeutic cover over an extended period of time following a single administration have potential to improve the treatment of chronic conditions. These devices eliminate the requirement for regular and frequent drug administration, thus reducing the pill burden experienced by patients. Furthermore, the use of modern technologies, such as 3D printing, during implant development and manufacture renders this approach well-suited for the production of highly tuneable devices that can deliver treatment regimens which are personalised for the individual. The objective of this work was to formulate subcutaneous implants loaded with a model hydrophobic compound, olanzapine (OLZ) using robocasting - a 3D-printing technique. The formulated cylindrical implants were prepared from blends composed of OLZ mixed with either poly(caprolactone) (PCL) or a combination of PCL and poly(ethylene)glycol (PEG). Implants were characterised using scanning electron microscopy (SEM), thermal analysis, infrared spectroscopy, and X-ray diffraction and the crystallinity of OLZ in the formulated devices was confirmed. In vitro release studies demonstrated that all the formulations were capable of maintaining sustained drug release over a period of 200 days, with the maximum percentage drug release observed to be c.a. 60 % in the same period.


Assuntos
Poliésteres , Polímeros , Humanos , Polímeros/química , Poliésteres/química , Polietilenoglicóis/química , Portadores de Fármacos/química , Impressão Tridimensional
4.
Bioengineering (Basel) ; 9(10)2022 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-36290553

RESUMO

Tissue-engineered (TE) scaffolds provide an 'off-the-shelf' alternative to autograft procedures and can potentially address their associated complications and limitations. The properties of TE scaffolds do not always match the surrounding bone, often sacrificing porosity for improved compressive strength. Previously, the layer-by-layer (LbL) assembly technique was used to deposit nanoclay containing multilayers capable of improving the mechanical properties of open-cell structures without greatly affecting the porosity. However, the previous coatings studied contained poly(ethylenimine) (PEI), which is known to be cytotoxic due to the presence of amine groups, rendering it unsuitable for use in biomedical applications. In this work, poly(diallydimethylammonium chloride) (PDDA)- and chitosan (CHI)-based polyelectrolyte systems were investigated for the purpose of nanoclay addition as an alternative to PEI-based polyelectrolyte systems. Nanocomposite coatings comprising of PEI, poly(acrylic acid) (PAA), Na+ montmorillonite (NC), PDDA, CHI and sodium alginate (ALG) were fabricated. The coatings were deposited in the following manner: (PEI/PAA/PEI/NC), PEI-(PDDA/PAA/PDDA/NC) and (CHI/ALG/CHI/ALG). Results from scanning electron microscopy (SEM) and energy-dispersive X-ray (EDX) analyses demonstrated that the nanoclay was successfully incorporated into each polymer bilayer system, creating a nanocomposite coating. Each coating was successful at tailoring the elastic modulus of the open-cell structures, with polyurethane foams exhibiting an increase from 0.15 ± 0.10 MPa when uncoated to 5.51 ± 0.40 MPa, 6.01 ± 0.36 MPa and 2.61 ± 0.41 MPa when coated with (PEI/PAA/PEI/NC), PEI-(PDDA/PAA/PDDA/NC) and (CHI/ALG/CHI/ALG), respectively. Several biological studies were conducted to determine the cytotoxicity of the coatings, including a resazurin reduction assay, scanning electron microscopy and fluorescent staining of the cell-seeded substrates. In this work, the PDDA-based system exhibited equivalent physical and mechanical properties to the PEI-based system and was significantly more biocompatible, making it a much more suitable alternative for biomaterial applications.

5.
J Mech Behav Biomed Mater ; 133: 105306, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35717775

RESUMO

The corrosion rate of Mg alloys is currently too high for viable resorbable implant applications. One possible solution is to coat the alloy with a hydroxyapatite (HA) layer to slow the corrosion and promote bone growth. As such coatings can be under severe stresses during implant insertion, we present a nano-mechanical and nano-tribological investigation of RF-sputtered HA films on AZ31 Mg alloy substrates. EDX and XRD analysis indicate that as-deposited coatings are amorphous and Ca-deficient whereas rapid thermal annealing results in c-axis orientation and near-stoichiometric composition. Analysis of the nanoindentation data using a thin film model shows that annealing increases the coating's intrinsic hardness (H) and strain at break (H/E) values, from 2.7 GPa to 9.4 GPa and from 0.043 to 0.079, respectively. In addition, despite being rougher, the annealed samples display better wear resistance; a sign that the rapid thermal annealing does not compromise their interfacial strength and that these systems have potential for resorbable bone implant applications.


Assuntos
Durapatita , Magnésio , Ligas/química , Materiais Revestidos Biocompatíveis/química , Corrosão , Durapatita/química , Magnésio/química , Teste de Materiais , Propriedades de Superfície
6.
Materials (Basel) ; 15(24)2022 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-36556835

RESUMO

Polycaprolactone (PCL) is a well-established biomaterial, offering extensive mechanical attributes along with low cost, biocompatibility, and biodegradability; however, it lacks hydrophilicity, bioactivity, and electrical conductivity. Advances in 3D fabrication technologies allow for these sought-after attributes to be incorporated into the scaffolds during fabrication. In this study, solvent-free Fused Deposition Modelling was employed to fabricate 3D scaffolds from PCL with increasing amounts of graphene (G), in the concentrations of 0.75, 1.5, 3, and 6% (w/w). The PCL+G scaffolds created were characterised physico-chemically, electrically, and biologically. Raman spectroscopy demonstrated that the scaffold outer surface contained both PCL and G, with the G component relatively uniformly distributed. Water contact angle measurement demonstrated that as the amount of G in the scaffold increases (0.75-6% w/w), hydrophobicity decreases; mean contact angle for pure PCL was recorded as 107.22 ± 9.39°, and that with 6% G (PCL+6G) as 77.56 ± 6.75°. Electrochemical Impedance Spectroscopy demonstrated a marked increase in electroactivity potential with increasing G concentration. Cell viability results indicated that even the smallest addition of G (0.75%) resulted in a significant improvement in electroactivity potential and bioactivity compared with that for pure PCL, with 1.5 and 3% exhibiting the highest statistically significant increases in cell proliferation.

7.
Bioengineering (Basel) ; 8(8)2021 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-34436110

RESUMO

Despite considerable advances in biomaterials-based bone tissue engineering technologies, autografts remain the gold standard for rehabilitating critical-sized bone defects in the oral and maxillofacial (OMF) region. A majority of advanced synthetic bone substitutes (SBS's) have not transcended the pre-clinical stage due to inferior clinical performance and translational barriers, which include low scalability, high cost, regulatory restrictions, limited advanced facilities and human resources. The aim of this study is to develop clinically viable alternatives to address the challenges of bone tissue regeneration in the OMF region by developing 'dual network composites' (DNC's) of calcium metaphosphate (CMP)-poly(vinyl alcohol) (PVA)/alginate with osteogenic ions: calcium, zinc and strontium. To fabricate DNC's, single network composites of PVA/CMP with 10% (w/v) gelatine particles as porogen were developed using two freeze-thawing cycles and subsequently interpenetrated by guluronate-dominant sodium alginate and chelated with calcium, zinc or strontium ions. Physicochemical, compressive, water uptake, thermal, morphological and in vitro biological properties of DNC's were characterised. The results demonstrated elastic 3D porous scaffolds resembling a 'spongy bone' with fluid absorbing capacity, easily sculptable to fit anatomically complex bone defects, biocompatible and osteoconductive in vitro, thus yielding potentially clinically viable for SBS alternatives in OMF surgery.

8.
Polymers (Basel) ; 13(18)2021 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-34578018

RESUMO

Polyetheretherketone (PEEK) is a high-performance thermoplastic polymer which has found increasing application in orthopaedics and has shown a lot of promise for 'made-to-measure' implants via additive manufacturing approaches. However, PEEK is bioinert and needs to undergo surface modification to make it at least osteoconductive to ensure a more rapid, improved, and stable fixation that will last longer in vivo. One approach to solving this issue is to modify PEEK with bioactive agents such as hydroxyapatite (HA). The work reported in this study demonstrates the direct 3D printing of PEEK/HA composites of up to 30 weight percent (wt%) HA using a Fused Filament Fabrication (FFF) approach. The surface characteristics and in vitro properties of the composite materials were investigated. X-ray diffraction revealed the samples to be semi-crystalline in nature, with X-ray Photoelectron Spectroscopy and Time-of-Flight Secondary Ion Mass Spectrometry revealing HA materials were available in the uppermost surface of all the 3D printed samples. In vitro testing of the samples at 7 days demonstrated that the PEEK/HA composite surfaces supported the adherence and growth of viable U-2 OS osteoblast like cells. These results demonstrate that FFF can deliver bioactive HA on the surface of PEEK bio-composites in a one-step 3D printing process.

9.
Emerg Med J ; 27(9): 712-3, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20581404

RESUMO

OBJECTIVE: To evaluate the use, success rate and time in the paediatric emergency department when employing the kissing technique to remove nasal foreign bodies from children. METHODS: The present work was a retrospective case note review for children attending with a nasal foreign body over a 15-month period. RESULTS: In all, 116 children had a confirmed nasal foreign body and 84 were treated by the kissing technique with a success rate of 48.8%. This group had lower rates of instrumentation (20.2% vs 53.1%) and general anaesthesia (11.9% vs 18.8%). The average time saved per patient who had the kissing technique attempted in the paediatric emergency department was 30.6 min. CONCLUSION: The kissing technique should be employed as a preferred technique to remove nasal foreign bodies in children.


Assuntos
Tratamento de Emergência/métodos , Corpos Estranhos/terapia , Cavidade Nasal , Pressão , Anestesia Geral/estatística & dados numéricos , Criança , Pré-Escolar , Tratamento de Emergência/estatística & dados numéricos , Feminino , Hospitais Pediátricos , Humanos , Masculino , Pais , Estudos Retrospectivos , Resultado do Tratamento
10.
Biomed Mater ; 14(6): 065008, 2019 09 20.
Artigo em Inglês | MEDLINE | ID: mdl-31539364

RESUMO

Using the layer-by-layer (LbL) assembly technique to deposit mechanically reinforcing coatings onto porous templates is a route for fabricating engineered bone scaffold materials with a combination of high porosity, strength, and stiffness. LbL assembly involves the sequential deposition of nano- to micro-scale multilayer coatings from aqueous solutions. Here, a design of experiments (DOE) approach was used to evaluate LbL assembly of polyethyleneimine (PEI), polyacrylic acid (PAA), and nanoclay coatings onto open-cell polyurethane foam templates. The thickness of the coatings, and the porosity, elastic modulus and collapse stress of coated foam templates were most strongly affected by the pH of PAA solutions, salt concentration, and interactions between these factors. The mechanical properties of coated foams correlated with the thickness of the coatings, but were also ascribed to changes in the coating properties due to the different assembly conditions. A DOE optimization aimed to balance the trade-off between higher mechanical properties but lower porosity of foam templates with increasing coating thickness. Micromechanical modeling predicted that deposition of 116 QLs would achieve mechanical properties of cancellous bone (>0.05 GPa stiffness and >2 MPa strength) at a suitable porosity of >70%. When capped with a final layer of PAA and cross-linked via thermal treatment, the PEI/PAA/PEI/nanoclay coatings exhibited good indirect cytotoxicity with mesenchymal stem cells. The ability of LbL assembly to deposit a wide range of functional constituents within multilayer-structured coatings makes the general strategy of templated LbL assembly a powerful route for fabricating engineered tissue scaffolds that can be applied onto various porous template materials to achieve a wide range of properties, pore structures, and multifunctionality.


Assuntos
Osso e Ossos/fisiologia , Nanocompostos/química , Engenharia Tecidual/métodos , Resinas Acrílicas/química , Animais , Antibacterianos/química , Materiais Biomiméticos/química , Células da Medula Óssea/citologia , Materiais Revestidos Biocompatíveis/química , Força Compressiva , Reagentes de Ligações Cruzadas/química , Elasticidade , Concentração de Íons de Hidrogênio , Teste de Materiais , Células-Tronco Mesenquimais/citologia , Polietilenoimina/química , Porosidade , Estresse Mecânico , Suínos , Alicerces Teciduais/química , Titânio/química , Microtomografia por Raio-X
11.
Eur J Emerg Med ; 10(2): 146-8, 2003 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12789075

RESUMO

Re-expansion pulmonary oedema is a well-recognized rare complication of the treatment of spontaneous pneumothorax. It has been associated with death in 20% of cases. A fit 20-year-old man who had returned from holiday 2 days previously presented with a large left-sided pneumothorax of 10 days' duration. He had exhibited symptoms of chest pain and shortness of breath during the return flight. He showed no signs of respiratory distress at presentation to the Accident and Emergency Department, but after treatment with a chest tube in the ensuing 90 min developed severe unilateral re-expansion pulmonary oedema and circulatory collapse. Factors in the aetiology of the condition and prevention are considered.


Assuntos
Pneumotórax/complicações , Edema Pulmonar/etiologia , Choque/etiologia , Adulto , Tubos Torácicos/efeitos adversos , Drenagem/efeitos adversos , Humanos , Masculino , Pneumotórax/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA