Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Medicina (Kaunas) ; 59(6)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37374377

RESUMO

Background and Objectives: To our knowledge, this is the first study that investigated the prognostic value of radiomics features extracted from not only staging 18F-fluorodeoxyglucose positron emission tomography (FDG PET/CT) images, but also post-induction chemotherapy (ICT) PET/CT images. This study aimed to construct a training model based on radiomics features obtained from PET/CT in a cohort of patients with locally advanced head and neck squamous cell carcinoma treated with ICT, to predict locoregional recurrence, development of distant metastases, and the overall survival, and to extract the most significant radiomics features, which were included in the final model. Materials and Methods: This retrospective study analyzed data of 55 patients. All patients underwent PET/CT at the initial staging and after ICT. Along the classical set of 13 parameters, the original 52 parameters were extracted from each PET/CT study and an additional 52 parameters were generated as a difference between radiomics parameters before and after the ICT. Five machine learning algorithms were tested. Results: The Random Forest algorithm demonstrated the best performance (R2 0.963-0.998) in the majority of datasets. The strongest correlation in the classical dataset was between the time to disease progression and time to death (r = 0.89). Another strong correlation (r ≥ 0.8) was between higher-order texture indices GLRLM_GLNU, GLRLM_SZLGE, and GLRLM_ZLNU and standard PET parameters MTV, TLG, and SUVmax. Patients with a higher numerical expression of GLCM_ContrastVariance, extracted from the delta dataset, had a longer survival and longer time until progression (p = 0.001). Good correlations were observed between Discretized_SUVstd or Discretized_SUVSkewness and time until progression (p = 0.007). Conclusions: Radiomics features extracted from the delta dataset produced the most robust data. Most of the parameters had a positive impact on the prediction of the overall survival and the time until progression. The strongest single parameter was GLCM_ContrastVariance. Discretized_SUVstd or Discretized_SUVSkewness demonstrated a strong correlation with the time until progression.


Assuntos
Neoplasias de Cabeça e Pescoço , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/terapia , Estudos Retrospectivos , Fluordesoxiglucose F18 , Compostos Radiofarmacêuticos , Recidiva Local de Neoplasia , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/terapia
2.
J Radiol Prot ; 42(3)2022 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-35973412

RESUMO

The hands of nuclear medicine (NM) personnel involved in radiopharmaceutical preparation and administration can receive significant radiation doses. The dose distribution across the hand is nonuniform and the Hp(0.07) doses obtained by an individual passive ring dosimeter do not always present a real situation. The aim of this study was to assess the extremity exposure of NM workers working with99mTc-labelled radiopharmaceuticals and with an automatic IRIDE (COMECER, Italy)18F-FDG injection system. Hp(0.07) doses were measured using calibrated thermoluminescent dosimeters-100 (TLD-100) and were read by a RIALTO TLD (NE Technology) reader. It was found that the most exposed parts of the hand during work with18F and99mTc radionuclides are the fingertips of the thumb, index finger and middle finger. The maximum fingertip doses were 1.3-2.4 times higher compared with the doses from the typical monitoring position (base of the middle finger of the dominant hand). When working with99mTc, the average hand doses were relatively high, i.e. 0.17 ± 0.04 and 0.37 ± 0.13 mSv Gbq-1for the left and the right hand, respectively, during preparation, and 58 ± 20 and 53 ± 13µSv GBq-1for the left and the right hand, respectively, during administration of99mTc labelled radiopharmaceuticals. Meanwhile, the lowest doses were found for hands during administration of18F-FDG (average hand dose 28 ± 13µSv GBq-1for the left hand and 28 ± 7µSv GBq-1for the right hand), which shows the advantages of automated injection/infusion systems, thus implementation of automatic infusion/injection in hospitals could be an expedient way to optimize Hp(0.07) doses to NM workers.


Assuntos
Exposição Ocupacional , Compostos Radiofarmacêuticos , Fluordesoxiglucose F18 , Mãos , Humanos , Exposição Ocupacional/análise , Doses de Radiação
3.
Environ Res ; 194: 110728, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33444608

RESUMO

Recycling of electric and electronic waste products (e-waste) which amounted to more than 50 million metric tonnes per year worldwide is a massive and global operation. Unfortunately, an estimated 70-80% of this waste has not been properly managed because the waste went from developed to low-income countries to be dumped into landfills or informally recycled. Such recycling has been carried out either directly on landfill sites or in small, often family-run recycling shops without much regulations or oversights. The process traditionally involved manual dismantling, cleaning with hazardous solvents, burning and melting on open fires, etc., which would generate a variety of toxic substances and exposure/hazards to applicators, family members, proximate residents and the environment. The situation clearly calls for global responsibility to reduce the impact on human health and the environment, especially in developing countries where poor residents have been shouldering the hazardous burden. On the other hand, formal e-waste recycling has been mainly conducted in small scales in industrialized countries. Whether the latter process would impose less risk to populations and environment has not been determined yet. Therefore, the main objectives of this review are: 1. to address current trends and emerging threats of not only informal but also formal e-waste management practices, and 2. to propose adequate measures and interventions. A major recommendation is to conduct independent surveillance of compliance with e-waste trading and processing according to the Basel Ban Amendment. The recycling industry needs to be carefully evaluated by joint effort from international agencies, producing industries and other stakeholders to develop better processes. Subsequent transition to more sustainable and equitable e-waste management solutions should result in more effective use of natural resources, and in prevention of adverse effects on health and the environment.


Assuntos
Resíduo Eletrônico , Gerenciamento de Resíduos , Resíduo Eletrônico/análise , Eletrônica , Humanos , Reciclagem
4.
Medicina (Kaunas) ; 54(6)2018 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-30544718

RESUMO

Background and objectives: Induction chemotherapy (ICT) before definitive chemoradiation (CRT) gives high response rates in locally advanced squamous cell carcinoma of the head and neck (LA-SCCHN). However, pre-ICT gross tumor volume (GTV) for radiotherapy (RT) planning is still recommended. As 18F-FDG PET/CT has an advantage of biological tumor information comparing to standard imaging methods, we aimed to evaluate the feasibility of 18F-FDG PET/CT-based post-ICT GTV delineation for RT planning in LA-SCCHN and to assess the prognostic value of PET parameters: maximum standardized uptake value (SUVmax), metabolic tumor volume (MTV) and total lesion glycolysis (TLG). Methods: 47 LA-SCCHN patients were treated with 3 cycles of ICT (docetaxel, cisplatin, and 5-fluorouracil) followed by CRT (70 Gy in 35 fractions with weekly cisplatin). Pre- and post-ICT PET/CT examinations were acquired. Planning CT was co-registered with post-ICT PET/CT and RT target volumes were contoured according to post-ICT PET. Post-ICT percentage decrease of SUVmax, MTV and TLG in primary tumor and metastatic regional lymphnodes (LN) was counted. Loco-regional failure patterns, 3-year progression free (PFS) and overall survival (OS) were evaluated. Results: 3-year PFS and OS rates for study population were 67% and 61% respectively. 31.9% of patients progressed loco-regionally. All progress was localized in high-to-intermediate dose (60⁻70 Gy) RT volumes and none in low dose (50 Gy) volumes. Decrease of SUVmax ≥ 74% (p = 0.04), MTV ≥ 68% (p = 0.03), TLG ≥ 76% (p = 0.03) in primary tumor, and LN TLG decrease ≥ 74% (p = 0.03) were associated with PFS. Decrease of primary tumor SUVmax ≥ 74% (p = 0.04), MTV ≥ 69% (p = 0.03), TLG ≥ 74% (p = 0.02) and LN TLG ≥ 73% (p = 0.02) were prognostic factors for OS. Conclusions: According to our results, 18F-FDG PET/CT-based post-ICT GTV delineation is feasible strategy without negative impacts on loco-regional control and survival. Percentage decrease of metabolic PET parameters SUVmax, MTV and TLG has a prognostic value in LA-SCCHN.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Quimioterapia de Indução , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/tratamento farmacológico , Adulto , Idoso , Estudos de Coortes , Progressão da Doença , Feminino , Fluordesoxiglucose F18/farmacocinética , Glicólise , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos/farmacocinética , Radioterapia , Análise de Regressão , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia , Carga Tumoral
5.
Antibiotics (Basel) ; 13(5)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38786169

RESUMO

Simple low-cost, nontoxic, environmentally friendly plant-extract-based polymer films play an important role in their application in medicine, the food industry, and agriculture. The addition of silver nanoparticles to the composition of these films enhances their antimicrobial capabilities and makes them suitable for the treatment and prevention of infections. In this study, polymer-based gels and films (AgRonPVA) containing silver nanoparticles (AgNPs) were produced at room temperature from fresh red onion peel extract ("Ron"), silver nitrate, and polyvinyl alcohol (PVA). Silver nanoparticles were synthesized directly in a polymer matrix, which was irradiated by UV light. The presence of nanoparticles was approved by analyzing characteristic local surface plasmon resonance peaks occurring in UV-Vis absorbance spectra of irradiated experimental samples. The proof of evidence was supported by the results of XRD and EDX measurements. The diffusion-based method was applied to investigate the antimicrobial activity of several types of microbes located in the environment of the produced samples. Bacteria Staphylococcus aureus ATCC 29213, Acinetobacter baumannii ATCC BAA 747, and Pseudomonas aeruginosa ATCC 15442; yeasts Candida parapsilosis CBS 8836 and Candida albicans ATCC 90028; and microscopic fungi assays Aspergillus flavus BTL G-33 and Aspergillus fumigatus BTL G-38 were used in this investigation. The greatest effect was observed on Staphylococcus aureus, Acinetobacter baumannii, and Pseudomonas aeruginosa bacteria, defining these films as potential candidates for antimicrobial applications. The antimicrobial features of the films were less effective against fungi and the weakest against yeasts.

6.
Gels ; 10(5)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38786207

RESUMO

Ionizing radiation covers a broad spectrum of applications. Since radioactive/radiation pollution is directly related to radiation risk, radiation levels should be strictly controlled. Different detection methods can be applied for radiation registration and monitoring. In this paper, radiation-induced variations in the optical properties of silver-enriched PVA-based hydrogel films with and without azo dye (Toluidine blue O, TBO, and Methyl red, MR) additives were investigated, and the feasibility of these free-standing films to serve as radiation detectors/exposure indicators was assessed. AgNO3 admixed with PVA gel was used as a source for the radiation-induced synthesis of silver nanoparticles (AgNPs) in irradiated gel films. Three types of sensors were prepared: silver-enriched PVA films containing a small amount of glycerol (AgPVAGly); silver-enriched PVA films with toluidine blue adducts (AgPVAGlyTBO); and silver-enriched PVA films with methyl red additives (AgPVAGlyMR). The selection of TBO and MR was based on their sensitivity to irradiation. The irradiation of the samples was performed in TrueBeam2.1 (VARIAN) using 6 MeV photons. Different doses up to 10 Gy were delivered to the films. The sensitivity of the films was assessed by analyzing the characteristic UV-Vis absorbance peaks on the same day as irradiation and 7, 30, 45, 90, and 180 days after irradiation. It was found that the addition of azo dyes led to an enhanced radiation sensitivity of the AgNPs containing films (0.6 Gy-1 for AgPVAGlyTBO and 0.4 Gy-1 for AgPVAGlyMR) irradiated with <2 Gy doses, indicating their applicability as low-dose exposure indicators. The irradiated films were less sensitive to higher doses. Almost no dose fading was detected between the 7th and 45th day after irradiation. Based on the obtained results, competing AgNP formation and color-bleaching effects in the AgPVAGly films with dye additives are discussed.

7.
Gels ; 9(12)2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38131933

RESUMO

This study employed a coarse-grained Monte Carlo (MC) simulation to investigate the radiation-induced polymerisation of methacrylic acid (MAA) in an aqueous solution. This method provides an alternative to traditional kinetic models, enabling a detailed examination of the micro-structure and growth patterns of MAA polymers, which are often not captured in other approaches. In this work, we generated multiple clones of a simulation box, each containing a specific chemical composition. In these simulations, every coarse-grained (CG) bead represents an entire monomer. The growth function, defined by the chemical behaviour of interacting substances, was determined through repeated random sampling. This approach allowed us to simulate the complex process of radiation-induced polymerisation, enhancing our understanding of the formation of poly(methacrylic acid) hydrogels at a microscopic level; while Monte Carlo simulations have been applied in various contexts of polymerisation, this study's specific approach to modelling the radiation-induced polymerisation of MAA in an aqueous environment, utilising the data obtained by quantum chemistry modelling, with an emphasis on micro-structural growth, has not been extensively explored in existing studies. This understanding is important for advancing the synthesis of these hydrogels, which have potential applications in diverse fields such as materials science and medicine.

8.
Gels ; 9(3)2023 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-36975638

RESUMO

Occupational radiation exposure monitoring is well-established in clinical or industrial environments with various different dosimeter systems. Despite the availability of many dosimetry methods and devices, a challenge with the occasional exposure registration, which may occur due to the spilling of radioactive materials or splitting of these materials in the environment, still exists, because not every individual will have an appropriate dosimeter at the time of the irradiation event. The aim of this work was to develop radiation-sensitive films-color-changing radiation indicators, which can be attached to or integrated in the textile. Polyvinyl alcohol (PVA)-based polymer hydrogels were used as a basis for fabrication of radiation indicator films. Several organic dyes (brilliant carmosine (BC), brilliant scarlet (BS), methylene red (MR), brilliant green (BG), brilliant blue (BB), methylene blue (MB) and xylenol orange (XiO)) were used as a coloring additives. Moreover, PVA films enriched with Ag nanoparticles (PVA-Ag) were investigated. In order to assess the radiation sensitivity of the produced films, experimental samples were irradiated in a linear accelerator with 6 MeV X-ray photons and the radiation sensitivity of irradiated films was evaluated using UV-Vis spectrophotometry method. The most sensitive were PVA-BB films indicating 0.4 Gy-1 sensitivity in low-dose (0-1 or 2 Gy) range. The sensitivity at higher doses was modest. These PVA-dye films were sensitive enough to detect doses up to 10 Gy and PVA-MR film indicated stable 33.3% decolorization after irradiation at this dose. It was found that the dose sensitivity of all PVA-Ag gel films varied from 0.068 to 0.11 Gy-1 and was dependent on the Ag additives concentration. Exchange of a small amount of water with ethanol or isopropanol caused the enhancement of radiation sensitivity in the films with the lowest AgNO3 concentration. Radiation-induced color change of AgPVA films varied between 30 and 40%. Performed research demonstrated the potential of colored hydrogel films in their applications as indicators for the assessment of the occasional radiation exposure.

9.
Gels ; 9(6)2023 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-37367169

RESUMO

UV-initiated green synthesis of metal nanoparticles by using plant extracts as photoreducing agents is of particular interest since it is an environmentally friendly, easy-to-maintain, and cost-effective method. Plant molecules that act as reducing agents are assembled in a highly controlled way which makes them suitable for metal nanoparticle synthesis. Depending on the plant species, their application for green synthesis of metal nanoparticles for diverse applications may contribute to the mediation/reduction in organic waste amounts, thus enabling the implementation of the circular economy concept. In this work, UV-initiated green synthesis of Ag nanoparticles in hydrogels and hydrogel's thin films containing gelatin (matrix), red onion peel extract of different concentrations, water, and a small amount of 1 M AgNO3 have been investigated and characterized using UV-Vis spectroscopy, SEM and EDS analysis, XRD technique, performing swelling experiments and antimicrobial tests using bacteria (Staphylococcus aureus, Acinetobacter baumannii, Pseudomonas aeruginosa), yeasts (Candida parapsilosis, Candida albicans) and microscopic fungi (Aspergillus flavus, Aspergillus fumigatus). It was found that the antimicrobial effectiveness of the silver-enriched red onion peel extract-gelatin films was higher at lower AgNO3 concentrations as compared to those usually used in the commercially available antimicrobial products. The enhancement of the antimicrobial effectiveness was analyzed and discussed, assuming the synergy between photoreducing agent (red onion peel extract) and silver nitrate (AgNO3) in the initial gel solutions leading to the intensification of Ag nanoparticles production.

10.
Polymers (Basel) ; 15(7)2023 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-37050314

RESUMO

There is a growing need to develop lead-free shielding materials that are safe, low weight, durable, environmentally friendly, chemically and mechanically stable and customizable for specific applications. Fused deposition modeling (FDM), an additive manufacturing technique based on the extrusion of a thermoplastic filament into a 3D printed object one layer at a time, could be employed well in applications involving ionizing radiation due to its relatively low cost, design flexibility and high manufacturing precision. This study aimed at developing 3D printing composites that contain Titanium dioxide as a filler agent for shielding in a medical radiation environment. First, the effect of low-dose ionizing radiation (up to 15 Gy) on the mechanical properties of common 3D printing polymers, ABS, ULTRAT, PLA, NYLON, ASA and PETG, was investigated. Since ABS experienced the lowest variation in its ultimate tensile strength (±5%) and Young's modulus (-5%/+11%), it was chosen as a matrix for a new extruded 3D filament containing TiO2 at 1 wt.%, 3 wt.%, and 5 wt.%. With the incorporation of TiO2 at different filler contents, the UTS of the ABS composites varied between 24.1 MPa and 28.4 MPa, with the highest value recorded for 3 wt.% TiO2. Young's modulus values were dependent on both the TiO2 concentration and on the irradiation dose. In addition, the ABS/TiO2 composites with a higher filler content (3 wt.% and 5 wt.%) maintained their attenuation ability even after exposure to a radiation dose of 100 Gy as opposed to pure ABS, which exhibited a ~2.5% reduction in its mass attenuation coefficient after exposure to the same dose of radiation. The pilot investigation performed demonstrated that the newly developed ABS/TiO2 composite containing 5 wt.% of filler can be successfully employed to shield electronic devices operating in a radiotherapy room.

11.
Polymers (Basel) ; 14(9)2022 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-35566867

RESUMO

Silicone-based polymer composites containing high atomic number additives are prioritized for the development of new materials for radiation shielding, due to their mechanical, thermal, electrical, and multifunctional properties. The X-ray attenuation properties, as well as mechanical properties, of the newly developed-lead-free multi-layered structures for radiation shielding, based on silicone composite layers containing tin, cerium oxide, tungsten oxide, and bismuth additives, are analyzed and discussed in this paper. It is shown that, by varying the additive concentrations in silicone composites, lead-free and flexible layered structures, exhibiting lead-equivalent X-ray shielding, can be fabricated.

12.
Gels ; 8(10)2022 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-36286130

RESUMO

As advanced radiotherapy techniques progress to deliver a high absorbed dose to the target volume while minimizing the dose to normal tissues using intensity-modulated beams, arcs or stereotactic radiosurgery, new challenges occur to assure that the high treatment dose is delivered homogeneously to the tumor. Small irradiation field sizes (≤1 cm2) that tightly conform to precise target regions and allow for the deliverance of doses with a high therapeutic ratio, are of particular interest. However, the small field dosimetry using conventional dosimeters is limited by the relative large size of the detector. Radiation-sensitive polymer gels have the potential to meet this dosimetry challenge due to their almost unlimited ability in resolving three-dimensional dose distributions of any shape and makes them unique and suitable for the evaluation of dose profiles and the verification of complex doses. In this work, dose distributions in nMAG gels that have been irradiated to different doses by applying a 6 MV FFF photon beam collimated to 1 cm2, were analyzed and the dose profiles were evaluated by applying a gamma passing rate criteria of 3%/3 mm and considering different post-irradiation time intervals between the irradiation and the gels read out process. X-ray CT and NMR imaging procedures were used for the dose evaluation. It was found that the shape and uniformity of the dose profiles were changing due to post-irradiation polymerization and gelation processes, indicating time dependent growing uniformity which was better expressed for the higher delivered doses. It was estimated that in order to obtain acceptably symmetric small field dose profiles, a longer post-irradiation time is needed for getting the full scope of the polymerization as compared with the recently recommended 24 h period between irradiation and the read out processes of the dose gels. An estimated overall uncertainty (double standard deviation, 95% confidence level) of 3.66% was achieved by applying R2 measurements (NMR read out), and a 3.81-applying X-ray CT read out for 12 Gy irradiated gels 56 h post-irradiation. An increasing tendency for the uncertainty was observed with a decreasing post-irradiation time. A gamma passing rate of 90.3% was estimated for the 12 Gy irradiated gels and, 56 h post-irradiation, the X-ray CT evaluated gels as well as a gamma passing rate of 92.7% was obtained for the NMR evaluated gels applying a 3%/3 mm passing criteria.

13.
Gels ; 8(5)2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-35621587

RESUMO

The essential component of modern radiation therapy is the application of steep dose gradients during patient treatment in order to maximize the radiation dose to the target volume and protect neighboring heathy tissues. However, volumetric dose distribution in an irradiated target is still a bottleneck of dose verification in modern radiotherapy. Dose gels are almost the only known dosimetry tool which allows for the evaluation of dose distribution in the irradiated volume due to gel's polymerization upon irradiation. The accuracy of dose gel dosimetry has its own obstacle, which is related to the continuation of the gel's polymerization after the radiation treatment procedure is finished. In this article, a method to monitor the polymerization dynamics of dose gels in real-time is proposed using a modified optical spectrometry system. Using the proposed method, the changes of the optical characteristics of irradiated nMAG dose gels in situ were assessed. The investigation revealed that the detectable polymerization in dose gel proceeds up to 6 h after irradiation. This time is significantly shorter compared with a commonly recommended 24 h waiting time allocated for polymer gel to settle. It was also found that dose rate significantly influences the temporal response of the nMAG dosimeter. By increasing the irradiation dose rate by a factor of 2, the time needed for the polymerization process to settle was increased by 22%. Identification of the gel's post-irradiation polymerization time interval and its dependence on irradiation parameters will contribute to more accurate dose verification using dose gel dosimetry.

14.
Gels ; 8(2)2022 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-35200451

RESUMO

Highly precise dose delivery to the target (tumor or cancerous tissue) is a key point when brain diseases are treated applying recent stereotactic techniques: intensity-modulated, image-guided radiotherapy, volumetric modulated arc therapy, Gamma knife radiosurgery. The doses in one single shot may vary between tens and hundreds of Gy and cause significant cell/tissue/organ damages. This indicates the need for implementation of quality assurance (QA) measures which are realized performing treatment dose verification with more than one calibrated quality assurance method or tool, especially when functional radiosurgery with a high dose (up to 40 Gy in our case) shall be delivered to the target using small 4 mm collimator. Application of two dosimetry methods: radiochromic film dosimetry using RTQA2 and EBT3 films and dose gel dosimetry using modified nPAG polymer gels for quality assurance purposes in stereotactic radiosurgery treatments using Leksell Gamma Knife© Icon™ facility is discussed in this paper. It is shown that due to their polymerization ability upon irradiation nPAG gels might be potentially used as a quality assurance tool in Gamma knife radiosurgery: they indicate well pronounced linear dose response in hypo-fractionated (up to 10 Gy) dose range and are sensitive enough to irradiation dose changes with a high (at least 0.2 mm) spatial resolution. Dose assessment sensitivity of gels depends on parameters of a dose evaluation method (optical or magnetic resonance imaging), however, is similar to this estimated using film dosimetry, which is set as a standard dosimetry method for dose verification in radiotherapy.

15.
Polymers (Basel) ; 13(22)2021 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-34833224

RESUMO

Polymer gels and films, due to their near equivalence to biological tissue, are amongst the most promising future dosimetry tools for medical applications. The application of polymer dose gels is limited by the sensitivity of dose readout methods and dose gel properties. It is a challenge to find suitable dosimeters for registration of doses delivered to the target by orthovoltage therapy units. The application of metal-particle-enriched polymer composites for dose registration in X-ray therapy might be an elegant solution, especially if recent dose-reading technologies exploring advantages of different physical phenomena are involved. In this work, X-rays from the orthovoltage therapy range were used for the irradiation of experimental samples. In addition, radiation-induced processes of formation of silver nanoparticles in AgNO3-PVA gels and in free standing AgNO3PVA films, also containing some additional solvents, namely glycerol, ethanol, and isopropanol, have been investigated, with the aim to apply the developed composites for medical dosimetry purposes. A simple and environmentally friendly method for the formation of free-standing AgPVA films at room temperature was proposed and realized for preparing AgPVA films for investigation. Radiation-induced synthesis of silver nanoparticles in AgPVA composites was investigated, analyzing LPSR-based UV-VIS spectral changes to the irradiated films with respect to irradiation doses, and dose-related tendencies were also evaluated. It was shown that AgPVA films were more sensitive for detection of doses from the interval 0-1.0 Gy, thus indicating potential application of AgPVA films for dosimetry purposes.

16.
J Occup Med Toxicol ; 15(1): 38, 2020 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-33371904

RESUMO

BACKGROUND: Until today, industrial sources contribute to the multifaceted contamination of environmental air. Exposure to air pollutants has the potential to initiate and promote asthma and chronic obstructive pulmonary disease (COPD). At global scale, both entities cause the majority of about 4 million annual deaths by respiratory disease. However, we identified industrial contamination as a subgroup of air pollution that may be associated with this burden and is underinvestigated in research. Therefore, the aim of this study is to investigate associations between substances industrially released into environmental air and the occurrence of asthma and COPD in the human population. Here we present the protocol for our systematic review of the current evidence. METHODS: The following determinations will be applied during the systematic review process and are specified in the protocol that complies with the PRISMA-P statement. Populations of children and adults, as well as outdoor workers, exposed to industrially released air pollutants are of interest. Eligible studies may include subjects as controls who are non- or less exposed to the investigated air pollutants. The outcomes new-onset asthma and/or COPD investigated with risk ratio, odds ratio, hazard ratio, incidence rate ratio, cumulative incidence, and incidence rate are eligible. We will search the electronic literature databases EMBASE, MEDLINE, and Web of Science for peer-reviewed reports of incidence studies and incidence case-control studies. After systematic sorting of initial records, included studies will be subjected to quality assessment. Data will be synthesized qualitatively and, if appropriate, quantitatively for risk ratio and odds ratio. We will maintain and provide a PRISMA report. DISCUSSION: Results of this systematic review may indicate alterations of incidence and risk of asthma and/or COPD in populations within industrial exposure radiuses including outdoor workplaces. Specific causal substances and compositions will be identified, but results will depend on the exposure assessment of the eligible studies. Our approach covers effects of industrial contributions to overall air pollution if studies reportedly attribute investigated emissions to industry. Results of this study may raise the question wether the available higher-level evidence sufficiently covers the current scale of industrial exposure scenarios and their potential harm to respiratory health. TRIAL REGISTRATION: This protocol was registered in PROSPERO, registration number CRD42020151573 .

17.
Appl Radiat Isot ; 65(7): 836-42, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17383886

RESUMO

The presence of noble gas and other short-lived radionuclides in air borne effluents from RBMK-1500-type reactor has been investigated using experimental and theoretical instrumentation for detection purposes. Activity concentrations of (85m)Kr, (87)Kr, (88)Kr, (135m)Xe, (135)Xe, (133)Xe and (41)Ar were measured in air emissions from Ignalina NPP using a special method and special equipment. Theoretical detection of reactor-borne radionuclides and investigation of their behaviour in a nuclear fuel during operation of nuclear reactor was performed using an analytical model based on reactor physics. An innovative method for the estimation of noble gas flow time from the defective nuclear fuel element through the ventilation stack of NPP to the atmosphere based on comparison of the experimentally and theoretically evaluated activity ratios of (88)Kr/(85m)Kr; (135)Xe/(133)Xe has been proposed. The estimated flow time of noble gas provides an excellent possibility to obtain modelling-based information about the qualitative and quantitative content of atmospheric releases from NPP.


Assuntos
Radioisótopos de Criptônio/química , Gases Nobres/química , Reatores Nucleares , Radioisótopos de Xenônio/química , Radioisótopos/química
18.
Phys Med ; 44: 1-10, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29254585

RESUMO

In vivo dosimetry is a powerful tool for dose verification in radiotherapy. Its application in high dose rate (HDR) brachytherapy is usually limited to the estimation of gross errors, due to inability of the dosimetry system/ method to record non-uniform dose distribution in steep dose gradient fields close to the radioactive source. In vivo dose verification in interstitial catheter based HDR brachytherapy is crucial since the treatment is performed inserting radioactive source at the certain positions within the catheters that are pre-implanted into the tumour. We propose in vivo dose verification method for this type of brachytherapy treatment which is based on the comparison between experimentally measured and theoretical dose values calculated at well-defined locations corresponding dosemeter positions in the catheter. Dose measurements were performed using TLD 100-H rods (6 mm long, 1 mm diameter) inserted in a certain sequences into additionally pre-implanted dosimetry catheter. The adjustment of dosemeter positioning in the catheter was performed using reconstructed CT scans of patient with pre-implanted catheters. Doses to three Head&Neck and one Breast cancer patient have been measured during several randomly selected treatment fractions. It was found that the average experimental dose error varied from 4.02% to 12.93% during independent in vivo dosimetry control measurements for selected Head&Neck cancer patients and from 7.17% to 8.63% - for Breast cancer patient. Average experimental dose error was below the AAPM recommended margin of 20% and did not exceed the measurement uncertainty of 17.87% estimated for this type of dosemeters. Tendency of slightly increasing average dose error was observed in every following treatment fraction of the same patient. It was linked to the changes of theoretically estimated dosemeter positions due to the possible patient's organ movement between different treatment fractions, since catheter reconstruction was performed for the first treatment fraction only. These findings indicate potential for further average dose error reduction in catheter based brachytherapy by at least 2-3% in the case that catheter locations will be adjusted before each following treatment fraction, however it requires more detailed investigation.


Assuntos
Braquiterapia/instrumentação , Catéteres , Dosimetria in Vivo/métodos , Doses de Radiação , Neoplasias da Mama/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Dosagem Radioterapêutica
19.
J Environ Radioact ; 90(1): 68-77, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16860912

RESUMO

The presence of man-made gamma emitting radionuclides in the region within 32km radius of the Ignalina NPP/Lithuania has been investigated during the period 2001-2004, prior to the closure of the first of the two operating RBMK 1500-type reactors. Gamma spectrometric measurements of various terrestrial and aquatic plants as well as of soil samples showed moderate environmental contamination with the fission product (137)Cs and with the neutron activation products (60)Co and (54)Mn. Traces of the activation products (65)Zn and (110m)Ag were found in the nearest vicinity of the NPP. Activity concentrations were inhomogeneously distributed in the area of interest. Moss and algae samples showed the highest uptake of radionuclides. In addition to the gamma spectrometric measurements, the levels of (14)C were determined in the same bio-indicator samples using accelerator mass spectrometry.


Assuntos
Reatores Nucleares , Poluentes Radioativos da Água/análise , Ecossistema , Meia-Vida , Poluentes Radioativos da Água/farmacocinética
20.
Radiat Prot Dosimetry ; 169(1-4): 336-9, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26535002

RESUMO

The interest to application of various surface plasmon resonance (SPR)-based sensors for the investigation of chemical and biological processes in thin layers deposited on the grating's surface/media is developing. Characterisation of processes as well as specimen's features might be performed analysing variations in optical properties (refraction index) of these thin layers. SPR sensors by default are characterised by high resolution and small uncertainties, and measurements might be performed in situ High-resolution, low-cost, SPR-based dosemeter concept has been proposed and realised depositing dose-sensitive nPAG gel layer onto diffraction grating's surface. The experimental set-up and method for information read out from the sensor were developed and implemented. Obtained results show a potential application of SPR-based dosemeter for dose measurements/mapping in steep gradient fields and/or large area fields.


Assuntos
Dosímetros de Radiação , Proteção Radiológica/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA