Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Mikrochim Acta ; 187(2): 153, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32008130

RESUMO

A solid-phase extraction method is presented for micro-extraction of three progestins (levonorgestrel, 19-norethisterone acetate and medroxyprogesterone acetate) from water samples. A mini-column was packed with 60 mg of oxidized multiwalled carbon nanotubes and coupled to a flow injection assembly. The extraction parameters, such as washing solution, eluent type, eluent volume, flow rate and sample volume, were optimized. Separation and determination were performed by HPLC with UV detection. The method has a good linear range (0.90-9.0 µg L-1), acceptable limits of detection (0.05-0.14 µg L-1) and low RSDs (0.8-4.6%). Attractive features of the method include low consumption of organic solvents and preconcentration factors of up to 100. The method was applied to analyze stream, underground and effluent water samples, and recoveries between 74 and 121% were obtained. Graphical abstractSchematic representation of the flow injection assembly couples to an ox-MWCNTs extraction column used to perform the solid phase extraction procedure of progestins in environmental water samples.

2.
Talanta ; 276: 126189, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38718645

RESUMO

A film composed of agarose and graphene (G) and magnetic nanoparticles (G-MNPs) is proposed as a sorbent for the extraction and determination of medroxyprogesterone (MED), levonorgestrel (LEV), norethisterone (NOR) and progesterone (PRO) in natural water samples. Both the preparation of the film and the extraction procedure were optimized. The optimal extraction parameters were as follows: isopropyl alcohol as activation solvent, sample pH value of 3.0, extraction time of 30 min, 1.00 mL of acetonitrile as eluent, elution time of 5 min and sample volume of 100.00 mL. HPLC with photodiode array detector was used for the separation and determination. The method presented a linear range between 2.50 and 75.0 µg L-1 for all analytes, and the LODs were between 1.40 and 1.80 µg L-1. The method was applied to natural water samples, obtaining satisfactory recovery values (75-111 %). In conclusion, for the immobilization of the G-MNPs, agarose was used, which is a non-toxic, renewable and biodegradable material. The G-MNPs-agarose film was reused up to 70 times, without losing its extraction capacity significantly and presenting excellent sorbent properties, which allow the extraction and preconcentration of the progestogens under study.


Assuntos
Progestinas , Poluentes Químicos da Água , Poluentes Químicos da Água/análise , Poluentes Químicos da Água/isolamento & purificação , Poluentes Químicos da Água/química , Progestinas/isolamento & purificação , Progestinas/análise , Progestinas/química , Adsorção , Nanopartículas de Magnetita/química , Extração em Fase Sólida/métodos , Sefarose/química , Cromatografia Líquida de Alta Pressão
3.
RSC Adv ; 13(13): 9055-9064, 2023 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-36950076

RESUMO

One of the main goals of green chemistry is to reduce the use of toxic materials and the generation of hazardous waste, both during method development and in the synthesis of the materials used. Thus, a biodegradable, single and reusable material composed of agarose and multi-walled carbon nanotubes was proposed. The film preparation was carefully optimized in order to obtain a one-piece sorbent, with high extraction efficiency and the possibility of reuse. The film was tested in the simultaneous extraction and preconcentration of three non-steroidal anti-inflammatory drugs (ketorolac, ketoprofen and piroxicam) from environmental water samples. The optimal extraction parameters were as follows: isopropyl alcohol as the activation solvent, a sample pH value of 3.0, extraction time of 30 min, 2.00 mL of acetonitrile as the eluent, an elution time of 5 minutes, and a sample volume of 250.00 mL. Under these conditions, the film was reusable 50 times without losing its extraction capacity significantly. HPLC with a photodiode array detector was used for the separation and determination. The method presented a linear range between 0.10 and 1.2 µg L-1, good sensitivity with limits of detection between 0.0075 and 0.0089 µg L-1, and quantification between 0.025 and 0.030 µg L-1. In addition, low RSD values (0.46-3.13%) were obtained demonstrating satisfactory precision. Stream water samples were analyzed, and recoveries between 82.0 and 109.0% were obtained.

4.
Talanta ; 245: 123465, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35427949

RESUMO

This manuscript reports on a fully automatic sequential injection system incorporating a 3D printed module for real-time monitoring of the release of Metridia luciferase from a modified liver epithelial cell line. To this end, a simple and effective approach for the automation of flash-type chemiluminescence assays was developed. The 3D printed module comprised an apical and a basal compartment that enabled monitoring membrane processes on both sides of the cell monolayer aimed at elucidating the direction of luciferase release. A natural release was observed after transfection with the luciferase plasmid by online measurement of the elicited light from the reaction of the synthesized luciferase with the coelenterazine substrate. Model substances for acute toxicity from the group of cholic acids - chenodeoxycholic and deoxycholic acids - were applied at the 1.0 and 0.5 mmol L-1 levels. The tested cholic acids caused changes in cell membrane permeability that was accompanied by an increased luciferase release. The obtained kinetic profiles were evaluated based on the delay between the addition of the toxic substance and the increase of the chemiluminescence signal. All experiments were carried out in a fully automatic system in ca. 5 min per sample in 30 min intervals and no manual interventions were needed for a sampling period of at least 6 h.


Assuntos
Copépodes , Animais , Ácidos Cólicos , Copépodes/metabolismo , Cinética , Luciferases/genética , Luciferases/metabolismo , Medições Luminescentes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA