Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pediatr Res ; 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38429571

RESUMO

BACKGROUND: Pediatric patients often receive topical anesthesia before skin procedures in the Emergency Department, with EMLA cream and amethocaine gel being common choices. The most effective option remains a subject of debate. OBJECTIVE: Our goal was to compare EMLA cream with amethocaine gel in pediatric patients undergoing topical anesthesia, focusing on outcomes: first-attempt cannulation success, child-reported visual analogue scale (VAS) score, parent-reported VAS score, observed pain score, child-reported absence of pain, and child-reported acceptable anesthesia. METHODS: A database search for studies comparing EMLA cream and amethocaine gel in pediatric topical anesthesia was conducted. Two reviewers extracted and cross-verified data, with a third ensuring accuracy. Using R software, a pairwise meta-analysis was performed via the Mantel-Haenszel method. Outcomes were pooled as risk ratios or standard mean differences with 95% confidence intervals using the random-effects model. RESULTS: Amethocaine gel surpasses EMLA cream in child-reported pain absence and first cannulation success. No significant differences were found in child-reported acceptable anesthesia or observed pain scores. Similarly, child- and parent-reported VAS scores showed no variations between EMLA and amethocaine. CONCLUSION: This analysis favors amethocaine gel for pediatric topical anesthesia. Further large randomized trials comparing EMLA cream and amethocaine gel in pediatric patients are warranted. IMPACT: Procedural pain is a major concern for pediatric patients, their families, and physicians. Topical anesthesia is routinely given prior to children undergoing skin-related procedures in the Emergency Department. In pediatric patients, topical anesthetics such as eutectic mixture of local anesthetics cream and amethocaine gel have proved to be pioneering in pain reduction, but the most effective method is often disputed. Presently, this is the most comprehensive pooled analysis of trials comparing EMLA cream and amethocaine gel in pediatric patients undergoing topical anesthesia. Amethocaine performed better with regards to child-reported absence of pain and first attempt cannulation success.

2.
Aesthetic Plast Surg ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38740623

RESUMO

BACKGROUND: Immediate action is required to address some complications of implant-based reconstruction after mastectomy to prevent reconstruction failure. Implant exchange may be simple but poses the risk of further complications while autologous flap reconstruction seems more complex but may pose less subsequent risk. Which of these is preferable remains unclear. METHODS: We reviewed thirty-two female breast cancer patients who had serious complications with their breast implants after post-mastectomy reconstruction. Latissimus dorsi flap (LDF) patients underwent explantation and immediate reconstruction with an LDF, while implant exchange (IE) patients underwent immediate implant removal and exchange with an expander followed by delayed reconstruction with silicon or immediately with a smaller size silicone implant. RESULTS: LDF patients underwent a single operation with an average duration of care of 31 days compared to an average 1.8 procedures (p= 0.005) with an average duration of care of 129.9 days (p < 0.001) among IE patients. Seven IE (50%) had serious complications that required subsequent revision while no LDF patients required additional procedures. Patient overall satisfaction and esthetics results were also superior in the LDF group at six months. CONCLUSION: In patients who want to reconstructively rescue and salvage their severely infected or exposed breast implant, the LDF offers an entirely autologous solution. LDF reconstruction in this setting allows patients to avoid an extended duration of care, reduces their risk of complications, and preserves the reconstructive process. LEVEL OF EVIDENCE III: The journal asks authors to assign a level of evidence to each article. For a complete description of Evidence-Based Medicine ratings, see the Table of Contents or the online Instructions for Authors at www.springer.com/00266 .

3.
Catheter Cardiovasc Interv ; 102(1): 166-175, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37172208

RESUMO

BACKGROUND: Post-procedural aortic insufficiency (AI) continues to be prevalent following transcatheter aortic valve replacement (TAVR). While several studies have assessed the outcomes of moderate-severe AI following TAVR, the incidence, predictors, and outcomes of mild AI remain unclear. METHODS: A systematic literature review was performed to identify studies reporting on mild AI following TAVR. The primary outcome was pooled incidence of post-TAVR mild AI. Secondary outcomes included pooled incidence of mild AI at 30 days and long term. The pooled incidence of midterm mortality in patients with post-TAVR mild AI was also evaluated. The random effect generalized linear mixed-effects model with logit-transformed proportions and Hartung-Knapp adjustment was used to calculate pooled incidence rates. Meta-regression was performed to identify predictors of mild AI. RESULTS: The pooled analysis included 19,241 patients undergoing TAVR across 50 studies. The mean age of patients ranged from 73 to 85 years, and female patients ranged from 20.0% to 83.3%. The overall pooled incidence of post-TAVR mild AI was 56.1% (95% confidence interval [CI] 0.31-0.64). The pooled incidence of mild AI at 30 days was 33.7% (95% CI 0.12-0.37). At mean follow-up of 1.15 years, the pooled incidence of mild AI was 37.0% (95% CI 0.16-0.45). The overall pooled incidence of Midterm mortality (mean follow-up 1.22 years) in patients with mild AI was 14.8% (95% CI 0.10-0.25). At meta-regression, none of the explored variables correlated with a difference in mild AI incidence. CONCLUSIONS: In published studies to date, 50% of patients undergoing TAVR develop mild AI postoperatively. In 37% of patients, this persists in long term. Though the incidence of AI is likely improving with newer generation TAVR valves, the prevalence and outcomes of mild AI should be closely monitored as TAVR volume and indications expand to younger patients with long life expectancy. The long-term outcomes of mild AI remain unclear. Further dedicated studies on post-TAVR mild AI are needed.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Fatores de Risco , Resultado do Tratamento , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia , Insuficiência da Valva Aórtica/etiologia
4.
J Cardiothorac Vasc Anesth ; 37(8): 1358-1367, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37120319

RESUMO

OBJECTIVES: For patients with aortic stenosis, transcatheter aortic valve replacement (TAVR) offers a less invasive treatment modality than conventional surgical valve replacement. Although the surgery is performed traditionally under general anesthesia (GA), recent studies have described success with TAVR using local anesthesia (LA) and/or conscious sedation. The study authors performed a pairwise meta-analysis to compare the clinical outcomes of TAVR based on operative anesthesia management. DESIGN: A random effects pairwise meta-analysis via the Mantel-Haenszel method. SETTING: Not applicable, as this is a meta-analysis. PARTICIPANTS: No individual patient data were used. INTERVENTIONS: Not applicable, as this is a meta-analysis. MEASUREMENTS AND MAIN RESULTS: The authors comprehensively searched the PubMed, Embase, and Cochrane databases to identify studies comparing TAVR performed using LA or GA. Outcomes were pooled as risk ratios (RR) or standard mean differences (SMD) and their 95% CIs. The authors' pooled analysis included 14,388 patients from 40 studies (7,754 LA; 6,634 GA). Compared to GA TAVR, LA TAVR was associated with significantly lower rates of 30-day mortality (RR 0.69; p < 0.01) and stroke (RR 0.78; p = 0.02). Additionally, LA TAVR patients had lower rates of 30-day major and/or life-threatening bleeding (RR 0.64; p = 0.01), 30-day major vascular complications (RR 0.76; p = 0.02), and long-term mortality (RR 0.75; p = 0.009). No significant difference was seen between the 2 groups for a 30-day paravalvular leak (RR 0.88, p = 0.12). CONCLUSIONS: Transcatheter aortic valve replacement performed using LA is associated with lower rates of adverse clinical outcomes, including 30-day mortality and stroke. No difference was seen between the 2 groups for a 30-day paravalvular leak. These results support the use of minimally invasive forms of TAVR without GA.


Assuntos
Estenose da Valva Aórtica , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Anestesia Local , Resultado do Tratamento , Acidente Vascular Cerebral/etiologia , Anestesia Geral/efeitos adversos , Valva Aórtica/cirurgia , Fatores de Risco
5.
J Card Surg ; 37(4): 801-807, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35137971

RESUMO

BACKGROUND/AIM: Peripheral access vessel dimensions in the general patient population screened for transcatheter aortic valve replacement (TAVR) can offer insight into the indications for pre-TAVR computed tomography angiography (CTA) assessment. We seek to determine peripheral access vessel sizes in patients screened for TAVR and association with patient characteristics. MATERIALS AND METHODS: All patients with severe, symptomatic aortic stenosis screened for TAVR at a high-volume center from April 2012 to March 2019 were retrospectively reviewed. For each patient, contrast-enhanced CTA was used to determine the minimal luminal diameters (MLDs) of the transfemoral access vessels, as measured between the inguinal ligament and the deep femoral artery for the femoral artery, and proximal to the inguinal ligament for the external and common iliac arteries, respectively. Paired and independent samples t-tests were used to compare means and regression analyses were performed to determine factors associated with MLD. RESULTS: A total of 1049 screened patients were included of which 826 (78.7%) underwent TAVR and 551 (52.5%) were male. The mean age was 80.6 (±9.6) years and the mean body mass index (BMI) was 26.7 (±5.9) kg/m2 . About 152 (14.5%) had peripheral vascular disease and 153 (14.6%) had chronic kidney disease. The mean (±2 standard deviations) MLDs of the right and left femoral arteries were 7.73 mm (4.68-10.78) and 7.68 mm (4.63-10.72), respectively. Male sex and BMI were associated with larger average femoral MLD while hyperlipidemia, hypertension, smoking, peripheral vascular disease, and coronary artery disease were inversely associated. CONCLUSION: Most patients screened for TAVR have minimum peripheral access vessel sizes exceeding the recommended minimum access route diameters of modern transcatheter heart valves. As sheath sizes decrease, clinicians must carefully judge patient individual risk factors to determine whether a pre-TAVR CTA assessing peripheral access vessel dimensions and anatomical contraindications is indicated. Larger studies and randomized controlled trials are required to compare the outcomes of TAVR with and without preoperative CTA.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada/métodos , Artéria Femoral/cirurgia , Humanos , Artéria Ilíaca/cirurgia , Masculino , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
6.
J Card Surg ; 36(7): 2486-2495, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33797799

RESUMO

BACKGROUND/AIM: With the growing contemporary use of bioprosthetic valves, whose limited long-term durability has been well-documented, an increase in the need for reintervention is expected. We perform a meta-analysis to compare the current standard of care, redo surgical aortic valve replacement (Redo SAVR) with the less invasive alternative, valve-in-valve transcatheter aortic valve replacement (ViV TAVR) for treating structural valve deterioration. METHODS: After a comprehensive literature search, studies comparing ViV TAVR to Redo SAVR were pooled to perform a pairwise meta-analysis using the random-effects model. Primary outcomes were 30-day and follow-up mortality. RESULTS: A total of nine studies including 9127 patients were included. ViV TAVR patients were significantly older (mean difference [MD], 5.82; p = .0002) and more frequently had hypercholesterolemia (59.7 vs. 60.0%; p = .0006), coronary artery disease (16.1 vs. 16.1%; p = .04), periphery artery disease (15.4 vs. 5.7%; p = .004), chronic obstructive pulmonary disease (29.3 vs. 26.2%; p = .04), renal failure (30.2 vs. 24.0%; p = .009), and >1 previous cardiac surgery (23.6 vs. 15.9%; p = .004). Despite this, ViV TAVR was associated with decreased 30-day mortality (OR, 0.56; p < .0001). Conversely, Redo SAVR had lower 30-day paravalvular leak (OR, 6.82; p = .04), severe patient-prosthesis mismatch (OR, 3.77; p < .0001), and postoperative aortic valve gradients (MD, 5.37; p < .0001). There was no difference in follow-up mortality (HR, 1.02; p = .86). CONCLUSIONS: Despite having patients with an increased baseline risk, ViV TAVR was associated with lower 30-day mortality, while Redo SAVR had lower paravalvular leak, severe patient-prosthesis mismatch, and postoperative gradients. Although ViV TAVR remains a feasible treatment option in high-risk patients, randomized trials are necessary to elucidate its efficacy over Redo SAVR.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Reoperação , Fatores de Risco , Resultado do Tratamento
7.
J Card Surg ; 36(11): 4308-4319, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34494307

RESUMO

BACKGROUND: When transfemoral (TF) access is contraindicated in patients undergoing transcatheter aortic valve replacement (TAVR), alternate access strategies are considered. The choice of one alternate access over the other remains controversial. METHODS: Following a comprehensive literature search, studies comparing any combination of TF, transapical (TA), transaortic (TAo), transcarotid (TC), and trans-subclavian (TS) TAVR were identified. Data were pooled using fixed- and random-effects network meta-analysis. Rank scores with probability ranks of different treatment groups were calculated. RESULTS: Eighty-four studies (26,449 patients) were included. Compared to TF access, TA and TAo accesses were associated with higher 30-day mortality (odds ratio [OR] 1.60, 95% confidence interval [CI] 1.31-1.94; OR 1.79, 95% CI 1.21-2.66, respectively), while the TC and TS showed no difference (OR 1.12, 95% CI 0.64-1.95; OR 1.23, 95% CI 0.67-2.27, respectively); TF access ranked best followed by TC. There was no significant difference in 30-day stroke; TC access ranked best followed by TS. At a weighted mean follow-up of 1.6 years, TA and TAo accesses were associated with higher long-term mortality versus TF (incidence rate ratio [IRR] 1.31, 95% CI 1.18-1.45; IRR 1.41, 95% CI 1.11-1.79, respectively); there was no difference between TC and TS versus TF access (IRR 1.02, 95% CI 0.70-1.47; IRR 1.16, 95% CI 0.82-1.66, respectively); TF access ranked best followed by TC. At a weighted mean follow-up of 1.4 years, only TA access was associated with higher long-term stroke compared to TF (IRR 3.01, 95% CI 1.15-7.87); TF access ranked as the best strategy followed by TAo. CONCLUSION: TC and TS approaches are associated with superior postoperative outcomes compared to other TAVR alternate access strategies. Randomized trials definitively assessing the safety and efficacy of alternate access strategies are needed.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Metanálise em Rede , Medição de Risco , Fatores de Risco , Resultado do Tratamento
8.
J Sep Sci ; 41(1): 99-124, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28994266

RESUMO

The development of new stationary phases has been the key aspect for fast and efficient high-performance liquid chromatography separation with relatively low backpressure. Core-shell particles, with a solid core and porous shell, have been extensively investigated and commercially manufactured in the last decade. The excellent performance of core-shell particles columns has been recorded for a wide range of analytes, covering small and large molecules, neutral and ionic (acidic and basic), biomolecules and metabolites. In this review, we first introduce the advance and advantages of core-shell particles (or more widely known as superficially porous particles) against non-porous particles and fully porous particles. This is followed by the detailed description of various methods used to fabricate core-shell particles. We then discuss the applications of common silica core-shell particles (mostly commercially manufactured), spheres-on-sphere particles and core-shell particles with a non-silica shell. This review concludes with a summary and perspective on the development of stationary phase materials for high-performance liquid chromatography applications.

10.
Chemistry ; 22(13): 4389-94, 2016 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-26864874

RESUMO

We have encapsulated the heat exchange material, n-docosane, into polyurethane capsules of different sizes. Decreasing the size of the capsules leads to changes of the crystallinity of phase-change material as well as melting/crystallization temperature. The novelty of the paper includes 1) protection of the nanostructured energy-enriched materials against environment during storage and controlled release of the encapsulated energy on demand and 2) study of the structure and surface-to-volume properties of the energy-enriched materials dispersed in capsules of different sizes. The stability of energy nanomaterials, influence of capsule diameter on their energy capacity, homogeneity and operation lifetime are investigated.

11.
Langmuir ; 30(41): 12190-9, 2014 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-25253125

RESUMO

Core-shell particles have a wide range of applications. Most of the core-shell particles are prepared in two or multiple steps. Core-shell silica microspheres, with solid core and porous shell, have been used as novel packing materials in recent years for highly efficient liquid chromatography separation with relatively low back-pressure. These core-shell silica microspheres are usually prepared by the time-consuming layer-by-layer technique. Built on our previous report of one-pot synthesis of core-shell nanospheres-on-microspheres (termed as SOS particles for "spheres-on-spheres"), we describe here a two-stage synthesis for the introduction of shell mesoporosity into SOS particles with tunable shell morphology by co-condensation of tetraethyl orthosilicate (TEOS) with 3-mercaptopropyltrimethoxysilane (MPTMS) in the presence of surfactant in the second stage. With MPTMS as the primary precursor at the first stage, some other silica precursors (apart from TEOS) are also employed at the second stage. Expansion of the surfactant-templated mesopores with swelling agents during the reaction and by hydrothermal postsynthesis treatment is then performed to allow the pore sizes (> 6 nm) suitable for separation of small molecules in liquid chromatography. Compared to the standard SOS silica (both the nanospheres and microspheres contain nearly no mesopores), the introduction of mesoporosity into the nanosphere shell increases the separation efficiency of small molecule mixtures by 4 times as judged by the height equivalent plate number, while the separation of protein mixtures is not negatively affected.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Microesferas , Nanosferas/química , Dióxido de Silício/química , Tamanho da Partícula , Porosidade , Propriedades de Superfície
12.
Tex Heart Inst J ; 51(1)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38623731

RESUMO

Dextrocardia with situs inversus totalis is a rare hereditary condition characterized by reversed orientation of the major thoracic and abdominal organs. Though dextrocardia itself is not believed to increase the risk of coronary artery disease, the workup and surgical management of patients with this condition may be technically challenging to heart team clinicians. This report describes the case management of a high-risk 56-year-old man with dextrocardia who presented with multivessel coronary artery disease.


Assuntos
Doença da Artéria Coronariana , Dextrocardia , Situs Inversus , Masculino , Humanos , Pessoa de Meia-Idade , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Situs Inversus/complicações , Situs Inversus/diagnóstico , Situs Inversus/cirurgia , Dextrocardia/complicações , Dextrocardia/cirurgia , Ponte de Artéria Coronária , Doenças Raras
13.
JTCVS Open ; 17: 23-36, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420535

RESUMO

Objective: For high-risk patients with aortic arch pathology, hybrid aortic arch repair with simultaneous or staged thoracic endovascular repair of the descending aorta may be a viable alternative to open repair. However, data on postintervention aortic remodeling remain limited. We report the short-term outcomes of remodeling of the thoracoabdominal aorta after hybrid arch repair + thoracic endovascular repair. Methods: All patients undergoing hybrid arch repair with planned zones 0 to 5 thoracic endovascular repair from January 2020 to March 2022 were retrospectively reviewed. Computed tomography angiography scans preoperatively, after hybrid aortic arch repair, and on long-term follow-up were analyzed for thoracoabdominal aorta remodeling. Mean change in aortic true luminal diameter and full luminal diameter was calculated at every level, and paired-samples t test was used to compare means. Results: Of 39 patients, 38 had follow-up data at a mean duration of 14.9 months. There were a total of 3 (7.7%) deaths, 0 (0.0%) strokes, and 0 (0.0%) paralysis. For the 35 patients undergoing thoracic endovascular repair for aortic dissection, at follow-up, there was a significant increase in the mean true luminal diameter at each level (P < .05), except at the aortic bifurcation and common iliac arteries. The largest increase in mean true luminal diameter (P < .01) was observed at the level of the left inferior pulmonary vein (mean difference +13.22 mm, 95% CI, 10.38-16.07), tracheal carina (mean difference +13.06 mm, 95% CI, 10.05-16.07), and inferior left atrium (mean difference +11.19 mm, 95% CI, 7.84-14.53). Conclusions: Hybrid arch repair with zones 0 to 5 leads to improved true lumen augmentation in zones 0 to 8 with complete false lumen thrombosis down to zone 5 at short-term follow-up. Zones 9 to 11, if involved, may require adjunctive treatment strategies for total aortic remodeling and complete false lumen obliteration.

14.
Artigo em Inglês | MEDLINE | ID: mdl-38842244

RESUMO

BACKGROUND: Data on predictors of poor hemodynamic presentation and rehospitalizations following transcatheter aortic valve replacement (TAVR) are limited. We evaluate the association between neighborhood socioeconomic status (NSES) on echocardiographic presentation and post-TAVR readmission at a high-volume institution. METHODS: All patients undergoing TAVR at a single institution between 2012 and 2022 were included. Patient addresses, baseline variables including Society of Thoracic Surgeons (STS) preoperative risk of mortality and frailty, and post-procedural outcomes were extracted from electronic health records. Using a validated US Census Bureau Index, the NSES of each patient (1-100) was tabulated, with lower values correlating to increased social deprivation. Patients were separated into four ranked groups based on NSES (rank 1: 1-25, rank 4: 76-100). Multivariable regression was performed to determine variables associated with number of days hospitalized in one-year following index TAVR procedure. RESULTS: A total of 2031 patients were included. The median NSES was 68 (IQR: 53-80). There was a total of 232 (11.4%) readmissions. The median number of days hospitalized in one year following TAVR was 4 (interquartile range [IQR]: 2-7) After adjusting for baseline variables including STS risk score and patient frailty, compared to patients in the lowest ranked socioeconomic group, patients of higher NSES were associated with lower aortic valve gradients at baselines (Exp[ß]=0.997, 95% CI: 0.993-0.999, P=0.049). Additionally, compared to patients in the lowest ranked socioeconomic group, patients of NSES were associated with shorter duration of readmission after risk-factor adjustments (Exp[ß]=0.996, 95% CI: 0.992-0.999, P=0.032). CONCLUSIONS: Patients of lower socioeconomic status are associated with higher aortic valve gradient at baseline and more days hospitalized in the first year after their index TAVR procedure after adjusting for other risk factors. As TAVR volume continues to expand, physicians and health systems must consider this independent factor when determining patient prognosis and readmission policies.

15.
J Cardiol ; 83(3): 177-183, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37611742

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) has evolved as an alternative to surgical aortic valve replacement (SAVR). In addition to full-sternotomy (FS), recent reports have shown successful minimally-invasive SAVR approaches, including mini-sternotomy (MS) and mini-thoracotomy (MT). This network-meta-analysis (NMA) seeks to provide an outcomes comparison based on these different modalities (MS, MT, TAVR) compared with FS as a reference arm for the management of aortic valve disease. METHODS: A comprehensive literature search was performed to identify studies that compared minimally-invasive SAVR (MS/MT) to conventional FS-SAVR, and/or TAVR. Bayesian NMA was performed using the random effects model. Outcomes were pooled as risk ratios (RR) with their 95 % confidence intervals (CIs). Our primary outcomes included 30-day mortality, stroke, acute kidney injury (AKI), major bleeding, new permanent pacemaker (PPM), and paravalvular leak (PVL). We also assessed long-term mortality at the latest follow-up. RESULTS: A total of 27,117 patients (56 studies) were included; 10,397 patients had FS SAVR, 9523 had MS, 5487 had MT, and 1710 had TAVR. Compared to FS, MS was associated with statistically-significantly lower rates of 30-day mortality (RR, 0.76, 95%CI 0.59-0.98), stroke (RR, 0.84, 95%CI 0.72-0.97), AKI (RR, 0.76, 95%CI 0.61-0.94), and long-term mortality (RR 0.84, 95%CI 0.72-0.97) at a weighted mean follow-up duration of 10.4 years, while MT showed statistically-significantly higher rates of 30-day PVL (RR, 3.76, 95%CI 1.31-10.85) and major bleeding (RR 1.45; 95%CI 1.08-1.94). TAVR had statistically significant lower rates of 30-day AKI (RR 0.49, 95%CI 0.31-0.77), but showed statistically-significantly higher PPM (RR 2.50; 95%CI 1.60-3.91) and 30-day PVL (RR 12.85, 95%CI 5.05-32.68) compared to FS. CONCLUSIONS: MS was protective against 30-day mortality, stroke, AKI, and long-term mortality compared to FS; TAVR showed higher rates of 30-day PVL and PPM but was protective against AKI. Conversely, MT showed higher rates of 30-day PVL and major bleeding. With the emergence of TAVR, the appropriate benchmarks for SAVR comparison in future trials should be the minimally-invasive SAVR approaches to provide clinical equipoise.


Assuntos
Injúria Renal Aguda , Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Teorema de Bayes , Metanálise em Rede , Fatores de Risco , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/etiologia , Hemorragia , Resultado do Tratamento
16.
Gen Thorac Cardiovasc Surg ; 72(2): 95-103, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37414971

RESUMO

BACKGROUND: The ideal conduit for mitral valve replacement (MVR) remains elusive, particularly among younger patients due to increased life expectancy. We perform a pairwise meta-analysis comparing the use of bioprosthetic valves (BPV) and mechanical mitral valves (MMV) in patients < 70 years old undergoing MVR. METHODS: We comprehensively searched medical databases to identify studies comparing the use of BPV and MMV in patients < 70 years old undergoing MVR. Pairwise meta-analysis was performed using the Mantel-Haenszel method in R version 4.0.2. Outcomes were pooled using the random effect model as risk ratios (RR) with their 95% confidence intervals (95% CI). RESULTS: 16,879 patients from 15 studies were pooled. Compared to MMV, BPV was associated with significantly higher rates of 30-day mortality (RR 1.53, p = 0.0006) but no difference in 30-day stroke (RR 0.70, p = 0.43). At a weighted mean follow-up duration of 14.1 years, BPV was associated with higher rates of long-term mortality (RR 1.28, p = 0.0054). No difference was seen between the two groups for risk of long-term stroke (RR 0.92, p = 0.67), reoperation(RR 1.72, p = 0.12), or major-bleeding (RR 0.57, p = 0.10) at a weighted mean follow-up duration of 11.7, 11.3, and 11.9 years, respectively. CONCLUSION: The use of MMV in patients < 70 undergoing MVR is associated with lower rates of 30-day/long-term mortality compared to BPV. No significant differences were observed for risk of 30-day/long-term stroke, long-term reoperation, and long-term major bleeding. These findings support the use of MMV in younger patients, although prospective, randomized trials are still needed.


Assuntos
Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Humanos , Idoso , Valva Mitral/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Acidente Vascular Cerebral/etiologia , Hemorragia/etiologia , Reoperação , Bioprótese/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia
17.
J Robot Surg ; 18(1): 41, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38231324

RESUMO

Online health resources are important for patients seeking perioperative information on robotic cardiac and thoracic surgery. The value of the resources depends on their readability, accuracy, content, quality, and suitability for patient use. We systematically assess current online health information on robotic cardiac and thoracic surgery. Systematic online searches were performed to identify websites discussing robotic cardiac and thoracic surgery. For each website, readability was measured by nine standardized tests, and accuracy and content were assessed by an independent panel of two robotic cardiothoracic surgeons. Quality and suitability of websites were evaluated using the DISCERN and Suitability Assessment of Materials tools, respectively. A total of 220 websites (120 cardiac, and 100 thoracic) were evaluated. Both robotic cardiac and thoracic surgery websites were very difficult to read with mean readability scores of 13.8 and 14.0 (p = 0.97), respectively, requiring at least 13 years of education to be comprehended. Both robotic cardiac and thoracic surgery websites had similar accuracy, amount of content, quality, and suitability (p > 0.05). On multivariable regression, academic websites [Exp (B)], 2.25; 95% confidence interval [CI], 1.60-3.16; P < 0.001), and websites with higher amount of content [Exp (B)],1.73; 95% CI, 1.24-2.41; P < 0.001) were associated with higher accuracy. There was no association between readability of websites and accuracy [Exp (B)], 1.04; 95% CI, 0.90-1.21; P = 0.57). Online information on robotic cardiac and thoracic surgery websites overestimate patients' understanding and require at least 13 years of education to be comprehended. As website accuracy is not associated with ease of reading, the readability of online resources can be improved without compromising accuracy.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Cirurgia Torácica , Procedimentos Cirúrgicos Torácicos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos
18.
Cureus ; 15(11): e48628, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38084165

RESUMO

Dual exemestane-everolimus therapy has been shown to confer a progression-free survival benefit in women with refractory advanced hormone-receptor-positive breast cancer. Patients with breast cancer may experience several other comorbidities, including hypertension, for which angiotensin-converting enzyme inhibitors (ACE-I) are a first-line therapy for hypertension of cardiovascular and/or renal etiology. One rare but feared side effect of ACE-I is severe angioedema due to decreased bradykinin degradation, which can lead to respiratory collapse. Several single-center case series have previously suggested that the use of everolimus in conjunction with ACE-I may lower the threshold for angioedema development. We report our experiences managing a 71-year-old with metastatic breast carcinoma and hypertension who presented with severe angioedema after the combined use of exemestane-everolimus with lisinopril.

19.
Cureus ; 15(10): e47322, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38022109

RESUMO

Total hip arthroplasty (THA) is the preferred treatment for patients with hip joint disorders refractory to conservative management. While original implants were designed to articulate a metallic femoral head onto a polyethylene liner, the popularity of "metal-on-metal" (MoM) hip implants surged in the early 21st century due to their perceived superior long-term durability and lower revision rates. However, subsequent follow-up studies showed high failure rates due to inflammatory responses to periprosthetic metallic debris leading to lymphocytic proliferation, soft tissue necrosis or fibrosis, systemic metal toxicity, and/or the development of cystic pseudotumors. Although these discoveries resulted in a significant decrease in MoM THA and revision procedures, the majority of MoM hip implants persist in the adult population. In this case report and review, we report the presentation, diagnostic work-up, and management of an 84-year-old status-post MoM THA who presented with unilateral leg tenderness and poor ambulation secondary to pseudotumor-induced sciatica.

20.
J Cardiovasc Surg (Torino) ; 64(6): 657-667, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37486236

RESUMO

The development of tricuspid regurgitation (TR) is a common complication of mitral valve disease. Although severe TR is usually operated on at the same time of mitral valve surgery (MVS), controversies remain regarding whether mild to moderate TR patients should be operated. Concomitant tricuspid valve repair with MVS for mild-moderate TR patients. Electronic databases were searched from inception to November 20, 2022 to include any observational or randomized controlled trials (RCT) that compare concomitant tricuspid repair with MVS versus MVS alone. Mantel-Haenszel method was used to pool study estimates and calculate odds ratios (OR) with 95% confidence intervals (CI). A total of 9813 patients from 25 studies were included. Regarding primary outcomes, concomitant repair group had significantly lower 30 days mortality (OR: 0.66; 95% CI 0.45 to 0.96), all-cause mortality-based on RCTs- (OR: 0.40; 95% CI 0.22 to 0.71), cardiovascular mortality (OR: 0.53; 95% CI: 0.33 to 0.86) and heart failure hospitalizations (OR: 0.41; 95% CI: 0.26 to 0.63). However, was associated with higher permanent pacemaker implantation rates (OR: 2.09; 95% CI: 1.45 to 3.00). There were no significant differences in terms of secondary outcomes: tricuspid valve reinterventions, stroke and acute kidney injury. Furthermore, repair group showed lower risk for TR progression degrees (OR 0.08; 95% CI 0.05 to 0.16) and decreased mean of TR progression (MD -1.85; 95% CI -1.92 to -1.77). Concomitant tricuspid valve repair in mild or moderate TR at time of MVS appears to reduce not only 30 days but also long-term all-cause and cardiovascular mortality weighed against the increased risk of pacemaker implantation.


Assuntos
Anuloplastia da Valva Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Insuficiência da Valva Mitral/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA