Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Europace ; 25(4): 1400-1407, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36892146

RESUMO

AIMS: The optimal anticoagulation regimen in patients with end-stage kidney disease (ESKD) undergoing atrial fibrillation (AF) catheter ablation is unknown. We sought to describe the real-world practice of peri-procedural anticoagulation management in patients with ESKD undergoing AF ablation. METHODS AND RESULTS: Patients with ESKD on haemodialysis undergoing catheter ablation for AF in 12 referral centres in Japan were included. The international normalized ratio (INR) before and 1 and 3 months after ablation was collected. Peri-procedural major haemorrhagic events as defined by the International Society on Thrombosis and Haemostasis, as well as thromboembolic events, were adjudicated. A total of 347 procedures in 307 patients (67 ±9 years, 40% female) were included. Overall, INR values were grossly subtherapeutic [1.58 (interquartile range: 1.20-2.00) before ablation, 1.54 (1.22-2.02) at 1 month, and 1.22 (1.01-1.71) at 3 months]. Thirty-five patients (10%) suffered major complications, the majority of which was major bleeding (19 patients; 5.4%), including 11 cardiac tamponade (3.2%). There were two peri-procedural deaths (0.6%), both related to bleeding events. A pre-procedural INR value of 2.0 or higher was the only independent predictor of major bleeding [odds ratio, 3.3 (1.2-8.7), P = 0.018]. No cerebral or systemic thromboembolism occurred. CONCLUSION: Despite most patients with ESKD undergoing AF ablation showing undertreatment with warfarin, major bleeding events are common while thromboembolic events are rare.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Falência Renal Crônica , Tromboembolia , Humanos , Feminino , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Falência Renal Crônica/complicações , Falência Renal Crônica/diagnóstico , Falência Renal Crônica/terapia , Ablação por Cateter/efeitos adversos , Sistema de Registros
2.
J Cardiovasc Electrophysiol ; 31(1): 112-118, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31724790

RESUMO

INTRODUCTION: Isolation of the left atrial appendage (LAA) is often performed in persistent atrial fibrillation (AF). Propagation patterns in the LAA during AF remain to be elucidated. We sought to characterize propagation patterns in the LAA during AF in persistent AF. METHODS: Persistent AF patients undergoing catheter ablation were studied. Pulmonary vein isolation (PVI) was performed during continuous AF. If AF was not terminated by PVI, bi-atrial mapping was performed using a multi-electrode catheter during AF. Maps were collected at each site for 30 seconds and analyzed offline with a novel software, CARTOFINDER. This software made automatic determinations of whether activation was focal or rotational. The left atrium (LA) was divided into five regions, of which the LAA was one, and the right atrium (RA) into three. RESULTS: Eighty patients were studied (62 ± 10 years, 65 males). On average, 9.6 ± 2.2 and 4.1 ± 1.2 maps were created in the LA and RA, respectively. The LAA was mapped in 70 patients, resulting in 85 maps. In the LAA, activation was identified as focal more often than rotational (64 [91%] vs 10 [14%] patients, P < .001), seven patients displayed both. The number of focal activation events was greatest in the LAA (28.5 events/30 seconds [interquartile range, 15-54]) of the eight atrial regions. During focal activation, sites designated as earliest activation frequently covered a wide area, rather than being localized to a discrete site (5.4 ± 3.1 electrodes). CONCLUSIONS: The results of this study suggest that focal activation is a major mechanism underlying the arrhythmogenicity of the LAA in persistent AF.


Assuntos
Potenciais de Ação , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Função do Átrio Esquerdo , Técnicas Eletrofisiológicas Cardíacas , Endocárdio/fisiopatologia , Frequência Cardíaca , Veias Pulmonares/fisiopatologia , Idoso , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Ablação por Cateter , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/cirurgia , Fatores de Tempo
3.
J Cardiol ; 75(4): 410-414, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31606246

RESUMO

BACKGROUND: The feasibility and safety of lead extraction of cardiac implantable electronic devices (CIEDs) in the elderly Asian population remain uncertain. We report the outcome and safety of transvenous excimer laser-assisted lead extraction of CIEDs in Japanese patients aged ≥80 years. METHODS: Consecutive 235 patients (age 67±15 years, 167 male) undergoing lead extraction of CIED with an excimer laser system (Philips, Andover, MA, USA) were included. RESULTS: Of 235 consecutive patients, 51 (22%) were ≥80 years (age 86±5 years, 14 were aged ≥90 years; 42 had pacemakers, 3 had implantable cardioverter defibrillators, and 6 had cardiac resynchronization therapy devices). The median implant duration was 110±95 months. Patients aged ≥80 years had lower body mass index (BMI, 20.7±3.1kg/m2 vs. 22.6±3.4kg/m2, p<0.001), higher incidence of CIED infection (98% vs. 63%, p<0.010), and longer duration of hospitalization (31±17 days vs. 24 ± 31 days, p<0.001) than patients aged <80 years. There were no differences between the age groups in the rate of complete retrieval (94.1% vs. 95.1%, p=0.726) and major complications, including cardiac tamponade and cardiogenic shock (2.0% vs. 2.7%, p=1.000). CONCLUSIONS: Excimer laser-assisted lead extraction was safe and feasible in the Japanese elderly population with low BMI, despite the high likelihood of procedural complications. Early removal of infected CIEDs should be performed without delay in elderly Asian populations.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Lasers de Excimer , Marca-Passo Artificial , Adulto , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
4.
J Arrhythm ; 36(4): 617-623, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32782630

RESUMO

BACKGROUND: The feasibility and safety of pulmonary vein isolation (PVI) using cryoballoon (CB) for paroxysmal atrial fibrillation (PAF) with minimally interrupted apixaban has not fully explored. METHODS: In this multicenter, randomized prospective study, we enrolled patients with PAF undergoing CB or radiofrequency (RF) ablation with interrupted (holding 1 dose) apixaban. The primary composite end point consisted of bleeding events, including pericardial effusion and major bleeding requiring blood transfusion, or thromboembolic events at 4 weeks after ablation; secondary end points included early recurrence of AF and procedural duration. RESULTS: A total of 250 patients underwent PVI (125 assigned to the RF ablation and 125 assigned to the CB ablation). The primary end point occurred in 1 patient in the CB ablation group (0.8%; 90% confidence interval [CI], 0.04 to 3.70) and 3 patients in the RF group (2.4%, P = .622; risk ratio, 0333; 90% CI, 0.05 to 2.20). All events were pericardial effusion, all of whom recovered after pericardiocentesis. Early recurrence of AF occurred in 4 patients (3.2%) in the RF group and in 6 patients (4.8%) in the CB group (P = .749). The procedural duration was shorter in the CB group than that in the RF group (136.5 ± 39.9 vs 179.5 ± 44.8 min, P < .001). CONCLUSION: CB ablation with minimally interrupted apixaban was feasible and safe in patients with PAF undergoing PVI, which was equivalent to RF ablation.

5.
J Cardiol Cases ; 20(3): 81-83, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31497170

RESUMO

The mechanism of adenosine-sensitive atrial tachycardia (AT) originating near the His bundle region has been reported to be due to reentry, as indicated by entrainment pacing at a site remote from the 'entrance' to the slow conduction zone of the postulated reentrant circuit. We report a case of AT, in which the change in response to the entrainment pacing following radiofrequency applications at the 'entrance' to the slow conduction zone not only suggested that the mechanism of the AT was reentry, but also the size of the reentrant circuit. .

7.
J Arrhythm ; 35(2): 287-289, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31007795

RESUMO

Recent studies have demonstrated the utility of cardiac sympathetic denervation (CSD) in patients with ventricular tachycardia (VT) refractory to antiarrhythmic drugs and catheter or surgical ablation. We present our experience with bilateral CSD in a patient with a recurrent VT despite attempts at treatment with catheter ablation and antiarrhythmic drugs, and this is the first description of the successful management of an idiopathic refractory VT with a bilateral CSD and concomitant oral amiodarone, occurring after catheter ablation of persistent atrial fibrillation and idiopathic outflow tract premature ventricular contractions.

8.
J Interv Card Electrophysiol ; 56(3): 249-257, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31654337

RESUMO

PURPOSE: Ripple map (RM) is a novel method for displaying activation pattern on the surface of a cardiac chamber. The aim of this study was to determine the utility of the RM in interpreting the atrial propagation in atrial tachycardia (AT) in comparison with a conventional local activation (LAT) map. METHODS: Three-dimensional electroanatomical mapping and ablation of AT were performed using multielectrode catheters and the CARTO3 ConfiDENSE Module (Biosense Webster). LAT maps and RMs were retrospectively reviewed by two independent observers who were blinded to the ablation results. RESULTS: High-density maps (1683 ± 1362 points) of 45 ATs (274 ± 64 ms; macroreentry 28, focal 17) were obtained in 39 patients. Of the 45 ATs, 41 (91%) were terminated by catheter ablation. A retrospective review of the LAT map alone by two observers resulted in correct diagnosis in 27% (12 ATs), whereas additional reviews of the RMs improved the diagnostic accuracy to 80% (36 ATs, P < 0.001). The diagnostic accuracy using the RM was equally high for macroreentrant (79%) and focal ATs (82%, P = 1.000). Of the 33 LAT maps in disagreement with the observers, adjusting the window-of-interest (WOI) after reviewing the RMs achieved diagnostic agreement of 91% (30 ATs). CONCLUSION: RMs allow us to have precise understanding of the atrial propagation on high-density CARTO maps for both focal and macroreentrant ATs, which is particularly useful for cases with difficult-to-interpret LAT maps.


Assuntos
Ablação por Cateter , Mapeamento Epicárdico/métodos , Taquicardia Supraventricular/fisiopatologia , Taquicardia Supraventricular/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA