Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
JAMA ; 305(11): 1097-105, 2011 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-21406646

RESUMO

CONTEXT: High platelet reactivity while receiving clopidogrel has been linked to cardiovascular events after percutaneous coronary intervention (PCI), but a treatment strategy for this issue is not well defined. OBJECTIVE: To evaluate the effect of high-dose compared with standard-dose clopidogrel in patients with high on-treatment platelet reactivity after PCI. DESIGN, SETTING, AND PATIENTS: Randomized, double-blind, active-control trial (Gauging Responsiveness with A VerifyNow assay-Impact on Thrombosis And Safety [GRAVITAS]) of 2214 patients with high on-treatment reactivity 12 to 24 hours after PCI with drug-eluting stents at 83 centers in North America between July 2008 and April 2010. INTERVENTIONS: High-dose clopidogrel (600-mg initial dose, 150 mg daily thereafter) or standard-dose clopidogrel (no additional loading dose, 75 mg daily) for 6 months. MAIN OUTCOME MEASURES: The primary end point was the 6-month incidence of death from cardiovascular causes, nonfatal myocardial infarction, or stent thrombosis. The key safety end point was severe or moderate bleeding according to the Global Utilization of Streptokinase and t-PA for Occluded Coronary Arteries (GUSTO) definition. A key pharmacodynamic end point was the rate of persistently high on-treatment reactivity at 30 days. RESULTS: At 6 months, the primary end point had occurred in 25 of 1109 patients (2.3%) receiving high-dose clopidogrel compared with 25 of 1105 patients (2.3%) receiving standard-dose clopidogrel (hazard ratio [HR], 1.01; 95% confidence interval [CI], 0.58-1.76; P = .97). Severe or moderate bleeding was not increased with the high-dose regimen (15 [1.4%] vs 25 [2.3%], HR, 0.59; 95% CI, 0.31-1.11; P = .10). Compared with standard-dose clopidogrel, high-dose clopidogrel provided a 22% (95% CI, 18%-26%) absolute reduction in the rate of high on-treatment reactivity at 30 days (62%; 95% CI, 59%-65% vs 40%; 95% CI, 37%-43%; P < .001). CONCLUSIONS: Among patients with high on-treatment reactivity after PCI with drug-eluting stents, the use of high-dose clopidogrel compared with standard-dose clopidogrel did not reduce the incidence of death from cardiovascular causes, nonfatal myocardial infarction, or stent thrombosis. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00645918.


Assuntos
Angioplastia Coronária com Balão , Stents Farmacológicos , Ativação Plaquetária/efeitos dos fármacos , Inibidores da Agregação Plaquetária/administração & dosagem , Testes de Função Plaquetária , Ticlopidina/análogos & derivados , Idoso , Doenças Cardiovasculares/mortalidade , Clopidogrel , Relação Dose-Resposta a Droga , Método Duplo-Cego , Feminino , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Agregação Plaquetária/efeitos dos fármacos , Estudos Prospectivos , Risco , Trombose/prevenção & controle , Ticlopidina/administração & dosagem
2.
J Am Coll Cardiol ; 64(6): 565-72, 2014 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-25104525

RESUMO

BACKGROUND: Transcatheter left atrial appendage (LAA) ligation may represent an alternative to oral anticoagulation for stroke prevention in atrial fibrillation. OBJECTIVES: This study sought to assess the early safety and efficacy of transcatheter ligation of the LAA for stroke prevention in atrial fibrillation. METHODS: This was a retrospective, multicenter study of consecutive patients undergoing LAA ligation with the Lariat device at 8 U.S. sites. The primary endpoint was procedural success, defined as device success (suture deployment and <5 mm leak by post-procedure transesophageal echocardiography), and no major complication at discharge (death, myocardial infarction, stroke, Bleeding Academic Research Consortium bleeding type 3 or greater, or cardiac surgery). Post-discharge management was per operator discretion. RESULTS: A total of 154 patients were enrolled. Median CHADS2 score (congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke, transient ischemic attack, or thromboembolism [doubled]) was 3 (interquartile range: 2 to 4). Device success was 94%, and procedural success was 86%. A major complication occurred in 15 patients (9.7%). There were 14 major bleeds (9.1%), driven by the need for transfusion (4.5%). Significant pericardial effusion occurred in 16 patients (10.4%). Follow-up was available in 134 patients at a median of 112 days (interquartile range: 50 to 270 days): Death, myocardial infarction, or stroke occurred in 4 patients (2.9%). Among 63 patients with acute closure and transesophageal echocardiography follow-up, there were 3 thrombi (4.8%) and 13 (20%) with residual leak. CONCLUSIONS: In this initial multicenter experience of LAA ligation with the Lariat device, the rate of acute closure was high, but procedural success was limited by bleeding. A prospective randomized trial is required to adequately define clinical efficacy, optimal post-procedure medical therapy, and the effect of operator experience on procedural safety.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Seguimentos , Humanos , Ligadura , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA