Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Crystallogr ; 55(Pt 6): 1514-1527, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36570664

RESUMO

Event-mode data collection presents remarkable new opportunities for time-of-flight neutron scattering studies of collective excitations, diffuse scattering from short-range atomic and magnetic structures, and neutron crystallography. In these experiments, large volumes of the reciprocal space are surveyed, often using different wavelengths and counting times. These data then have to be added together, with accurate propagation of the counting errors. This paper presents a statistically correct way of adding and histogramming the data for single-crystal time-of-flight neutron scattering measurements. In order to gain a broader community acceptance, particular attention is given to improving the efficiency of calculations.

2.
Rev Sci Instrum ; 91(12): 125111, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33379978

RESUMO

The European Spallation Source (ESS), which is under construction in Lund (Sweden), will be the next leading neutron facility with an unprecedented brilliance and novel long-pulse time structure. A long-pulse source not only provides a high time-average flux but also opens the possibility to tune the resolution by using pulse shaping choppers. Thus, an instrument can readily be operated in either a high flux or a high resolution mode. Several of the shorter instruments at the ESS will employ Wavelength Frame Multiplication (WFM) in order to enable a sufficient resolution while offering a continuous and broad wavelength range. A test beamline was operated until the end of 2019 at the research reactor in Berlin to test components and methods, including WFM, in order to prepare the new facility for the operation of neutron instruments and successful first science. We herein demonstrate the implementation of WFM for reflectometry. By selecting a short pulse mode under the same geometrical configuration, we compare and discuss the results for two reference samples. The reported experiments not only serve to prove the reliability of the WFM approach but also, for the first time, demonstrate the full instrument control, data acquisition and data reduction chain that will be implemented at the ESS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA