Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet Oncol ; 23(6): e251-e312, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35550267

RESUMO

In sub-Saharan Africa (SSA), urgent action is needed to curb a growing crisis in cancer incidence and mortality. Without rapid interventions, data estimates show a major increase in cancer mortality from 520 348 in 2020 to about 1 million deaths per year by 2030. Here, we detail the state of cancer in SSA, recommend key actions on the basis of analysis, and highlight case studies and successful models that can be emulated, adapted, or improved across the region to reduce the growing cancer crises. Recommended actions begin with the need to develop or update national cancer control plans in each country. Plans must include childhood cancer plans, managing comorbidities such as HIV and malnutrition, a reliable and predictable supply of medication, and the provision of psychosocial, supportive, and palliative care. Plans should also engage traditional, complementary, and alternative medical practices employed by more than 80% of SSA populations and pathways to reduce missed diagnoses and late referrals. More substantial investment is needed in developing cancer registries and cancer diagnostics for core cancer tests. We show that investments in, and increased adoption of, some approaches used during the COVID-19 pandemic, such as hypofractionated radiotherapy and telehealth, can substantially increase access to cancer care in Africa, accelerate cancer prevention and control efforts, increase survival, and save billions of US dollars over the next decade. The involvement of African First Ladies in cancer prevention efforts represents one practical approach that should be amplified across SSA. Moreover, investments in workforce training are crucial to prevent millions of avoidable deaths by 2030. We present a framework that can be used to strategically plan cancer research enhancement in SSA, with investments in research that can produce a return on investment and help drive policy and effective collaborations. Expansion of universal health coverage to incorporate cancer into essential benefits packages is also vital. Implementation of the recommended actions in this Commission will be crucial for reducing the growing cancer crises in SSA and achieving political commitments to the UN Sustainable Development Goals to reduce premature mortality from non-communicable diseases by a third by 2030.


Assuntos
COVID-19 , Neoplasias , Doenças não Transmissíveis , África Subsaariana/epidemiologia , COVID-19/epidemiologia , COVID-19/prevenção & controle , Criança , Atenção à Saúde , Humanos , Neoplasias/epidemiologia , Neoplasias/terapia , Pandemias
2.
J Pediatr Gastroenterol Nutr ; 65(2): e35-e42, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28267073

RESUMO

BACKGROUND AND OBJECTIVE: Although named because of its sucrose hydrolytic activity, this mucosal enzyme plays a leading role in starch digestion because of its maltase and glucoamylase activities. Sucrase-deficient mutant shrews, Suncus murinus, were used as a model to investigate starch digestion in patients with congenital sucrase-isomaltase deficiency.Starch digestion is much more complex than sucrose digestion. Six enzyme activities, 2 α-amylases (Amy), and 4 mucosal α-glucosidases (maltases), including maltase-glucoamylase (Mgam) and sucrase-isomaltase (Si) subunit activities, are needed to digest starch to absorbable free glucose. Amy breaks down insoluble starch to soluble dextrins; mucosal Mgam and Si can either directly digest starch to glucose or convert the post-α-amylolytic dextrins to glucose. Starch digestion is reduced because of sucrase deficiency and oral glucoamylase enzyme supplement can correct the starch maldigestion. The aim of the present study was to measure glucogenesis in suc/suc shrews after feeding of starch and improvement of glucogenesis by oral glucoamylase supplements. METHODS: Sucrase mutant (suc/suc) and heterozygous (+/suc) shrews were fed with C-enriched starch diets. Glucogenesis derived from starch was measured as blood C-glucose enrichment and oral recombinant C-terminal Mgam glucoamylase (M20) was supplemented to improve starch digestion. RESULTS: After feedings, suc/suc and +/suc shrews had different starch digestions as shown by blood glucose enrichment and the suc/suc had lower total glucose concentrations. Oral supplements of glucoamylase increased suc/suc total blood glucose and quantitative starch digestion to glucose. CONCLUSIONS: Sucrase deficiency, in this model of congenital sucrase-isomaltase deficiency, reduces blood glucose response to starch feeding. Supplementing the diet with oral recombinant glucoamylase significantly improved starch digestion in the sucrase-deficient shrew.


Assuntos
Erros Inatos do Metabolismo dos Carboidratos/tratamento farmacológico , Suplementos Nutricionais , Digestão/fisiologia , Fármacos Gastrointestinais/uso terapêutico , Glucana 1,4-alfa-Glucosidase/uso terapêutico , Amido/metabolismo , Complexo Sacarase-Isomaltase/deficiência , Sacarase/deficiência , Administração Oral , Animais , Animais Geneticamente Modificados , Biomarcadores/metabolismo , Glicemia/metabolismo , Erros Inatos do Metabolismo dos Carboidratos/metabolismo , Masculino , Distribuição Aleatória , Musaranhos , Complexo Sacarase-Isomaltase/metabolismo , Resultado do Tratamento
3.
Acta Oncol ; 53(10): 1312-20, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24797885

RESUMO

BACKGROUND: Adjuvant chemoradiotherapy improves both overall- and relapse-free survival in patients with resected gastric cancer. However, this comes at the cost of increased treatment-related toxicity. Proton therapy (PT) has distinct dosimetric characteristics that may reduce dose to normal tissues, improving the therapeutic ratio. The purpose of this treatment planning study is to compare PT and intensity-modulated x-ray therapy (IMXT) in gastric cancer with regards to normal tissue sparing. MATERIAL AND METHODS: The patient population consisted of resected gastric cancer patients treated at a single institution between 2008 and 2013. Patients who had undergone 4D CT simulation were replanned to the originally delivered doses (45-54 Gy in 25-30 daily fractions) using six-field photon IMXT and 2-3-field PT (double scattering-uniform scanning techniques). RESULTS: Thirteen patients were eligible for the planning comparison. IMXT provided slightly higher homogeneity indices (median values 0.04 ± 0.01 vs. 0.07 ± 0.01, p = 0.03). PT resulted in significantly (p < 0.05) lower intermediate-low doses for all the normal tissues examined (small bowel V15 82 ml vs. 133 ml, liver mean doses Gy 11.9 vs. 14.4 Gy, left/right kidney mean doses 5/0.9 Gy vs. 7.8/3.1 Gy, heart mean doses 7.4 Gy vs. 9.5 Gy). The total energy deposited outside the target volume was significantly lower with PT (median integral dose 90.1 J vs. 129 J). Four patients were treated with PT: treatment was feasible and verifications scans showed that target coverage was robust. CONCLUSION: PT can contribute to normal tissue sparing in the adjuvant treatment of gastric cancer, with a potential benefit in terms of compliance to treatment, acute and late toxicities.


Assuntos
Órgãos em Risco/efeitos da radiação , Terapia com Prótons/métodos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Gástricas/radioterapia , Estudos de Viabilidade , Humanos , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco/diagnóstico por imagem , Lesões por Radiação/prevenção & controle , Radiografia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/patologia , Neoplasias Gástricas/cirurgia
4.
J Pediatr Gastroenterol Nutr ; 57(6): 704-12, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23838818

RESUMO

OBJECTIVES: Six enzyme activities are needed to digest starch to absorbable free glucose; 2 luminal α-amylases (AMY) and 4 mucosal maltase-glucoamylase (MGAM) and sucrase-isomaltase (SI) subunit activities are involved in the digestion. The AMY activities break down starch to soluble oligomeric dextrins; mucosal MGAM and SI can either directly digest starch to glucose or convert the post-α-amylolytic dextrins to glucose. We hypothesized that MGAM, with higher maltase than SI, drives digestion on ad limitum intakes and SI, with lower activity but more abundant amount, constrains ad libitum starch digestion. METHODS: Mgam null and wild-type (WT) mice were fed with starch diets ad libitum and ad limitum. Fractional glucogenesis (fGG) derived from starch was measured and fractional gluconeogenesis and glycogenolysis were calculated. Carbohydrates in small intestine were determined. RESULTS: After ad libitum meals, null and WT had similar increases of blood glucose concentration. At low intakes, null mice had less (f)GG (P = 0.02) than WT mice, demonstrating the role of Mgam activity in ad limitum feeding; null mice did not reduce fGG responses to ad libitum intakes demonstrating the dominant role of SI activity during full feeding. Although fGG was rising after feeding, fractional gluconeogenesis fell, especially for null mice. CONCLUSIONS: The fGNG (endogenous glucogenesis) in null mice complemented the fGG (exogenous glucogenesis) to conserve prandial blood glucose concentrations. The hypotheses that Mgam contributes a high-efficiency activity on ad limitum intakes and SI dominates on ad libitum starch digestion were confirmed.


Assuntos
Carboidratos da Dieta/metabolismo , Digestão , Gluconeogênese , Glucose/metabolismo , Amido/metabolismo , Complexo Sacarase-Isomaltase/metabolismo , alfa-Glucosidases/metabolismo , Animais , Glicemia/metabolismo , Digestão/genética , Mucosa Intestinal/enzimologia , Mucosa Intestinal/metabolismo , Intestino Delgado/enzimologia , Intestino Delgado/metabolismo , Camundongos , Camundongos Knockout , Mutação , Período Pós-Prandial , alfa-Glucosidases/genética
5.
J Appl Clin Med Phys ; 14(1): 4159, 2013 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-23318397

RESUMO

The American Association of Physicists in Medicine (AAPM) sponsors two summer undergraduate research programs to attract top performing undergraduate students into graduate studies in medical physics: the Summer Undergraduate Fellowship Program (SUFP) and the Minority Undergraduate Summer Experience (MUSE). Undergraduate research experience (URE) is an effective tool to encourage students to pursue graduate degrees. The SUFP and MUSE are the only medical physics URE programs. From 2001 to 2012, 148 fellowships have been awarded and a total of $608,000 has been dispersed to fellows. This paper reports on the history, participation, and status of the programs. A review of surveys of past fellows is presented. Overall, the fellows and mentors are very satisfied with the program. The efficacy of the programs is assessed by four metrics: entry into a medical physics graduate program, board certification, publications, and AAPM involvement. Sixty-five percent of past fellow respondents decided to pursue a graduate degree in medical physics as a result of their participation in the program. Seventy percent of respondents are currently involved in some educational or professional aspect of medical physics. Suggestions for future enhancements to better track and maintain contact with past fellows, expand funding sources, and potentially combine the programs are presented.


Assuntos
Educação de Graduação em Medicina/economia , Educação de Graduação em Medicina/estatística & dados numéricos , Bolsas de Estudo/economia , Física Médica/economia , Física Médica/educação , Bolsas de Estudo/estatística & dados numéricos , Física Médica/estatística & dados numéricos , Estados Unidos
6.
J Appl Clin Med Phys ; 14(3): 4138, 2013 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-23652247

RESUMO

One of the main components in a Calypso 4D localization and tracking system is an electromagnetic array placed above patients that is used for target monitoring during radiation treatment. The beam attenuation and beam spoiling properties of the Calypso electromagnetic array at various beam angles were investigated. Measurements were performed on a Varian Clinac iX linear accelerator with 6 MV and 15 MV photon beams. The narrow beam attenuation properties were measured under a field size of 1 cm × 1 cm, with a photon diode placed in a cylindrical graphite buildup cap. The broad beam attenuation properties were measured under a field size of 10 cm × 10 cm, with a 0.6 cc cylindrical Farmer chamber placed in a polystyrene buildup cap. Beam spoiling properties of the array were studied by measuring depth-dose change from the array under a field size of 10 cm × 10 cm in a water-equivalent plastic phantom with an embedded Markus parallel plate chamber. Change in depth doses were measured with the array placed at distances of 2, 5, and 10 cm from the phantom surface. Narrow beam attenuation and broad beam attenuation from the array were found to be less than 2%-3% for both 6 MV and 15 MV beams at angles less than 40°, and were more pronounced at more oblique angles. Spoiling effects are appreciable at beam buildup region, but are insignificant at depths beyond dmax. Dose measurements in a QA phantom using patient IMRT and VMAT treatment plans were shown to have less than 2.5% dose difference with the Calypso array. The results indicate that the dose difference due to the placement of Calypso array is clinically insignificant.


Assuntos
Fenômenos Eletromagnéticos , Neoplasias/patologia , Neoplasias/radioterapia , Fótons , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica
7.
Z Med Phys ; 33(2): 124-134, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35750591

RESUMO

Compton-based prompt gamma (PG) imaging is being investigated by several groups as a potential solution for in vivo range monitoring in proton therapy. The performance of this technique depends on the detector system as well as the ability of the reconstruction method to obtain good spatial resolution to establish a quantitative correlation between the PG emission and the proton beam range in the patient. To evaluate the feasibility of PG imaging for range monitoring, we quantitatively evaluated the emission distributions reconstructed by a Maximum Likelihood Expectation Maximization (MLEM) and a Stochastic Origin Ensemble (SOE) algorithm. To this end, we exploit experimental and Monte Carlo (MC) simulation data acquired with the Polaris-J Compton Camera (CC) prototype. The differences between the proton beam range (RD) defined as the 80% distal dose fall-off and the PG range (RPG), obtained by fitting the distal end of the reconstructed profile with a sigmoid function, were quantified. A comparable performance of both reconstruction algorithms was found. For both experimental and simulated irradiation scenarios, the correlation between RD and RPG was within 5 mm. These values were consistent with the ground truth distance (RD-RPGg≈ 3 mm) calculated by using the expected PG emission available from MC simulation. Furthermore, shifts of 3 mm in the proton beam range were resolved with the MLEM algorithm by calculating the relative difference between the RPG for each reconstructed profile. In non-homogeneous targets, the spatial changes in the PG emission due to the different materials could not be fully resolved from the reconstructed profiles; however, the fall-off region still resembled the ground truth emission. For this scenario, the PG correlation (RD-RPG) varied from 0.1 mm to 4 mm, which is close to the ground truth correlation (3 mm). This work provides a framework for the evaluation of the range monitoring capabilities of a CC device for PG imaging. The two investigated image reconstruction algorithms showed a comparable and consistent performance for homogeneous and heterogeneous targets.


Assuntos
Terapia com Prótons , Prótons , Humanos , Processamento de Imagem Assistida por Computador/métodos , Funções Verossimilhança , Imagens de Fantasmas , Terapia com Prótons/métodos , Algoritmos , Método de Monte Carlo
8.
Biomed Phys Eng Express ; 9(4)2023 05 12.
Artigo em Inglês | MEDLINE | ID: mdl-37141867

RESUMO

Proton therapy is a type of radiation therapy that can provide better dose distribution compared to photon therapy by delivering most of the energy at the end of range, which is called the Bragg peak (BP). The protoacoustic technique was developed to determine the BP locationsin vivo, but it requires a large dose delivery to the tissue to obtain a high number of signal averaging (NSA) to achieve a sufficient signal-to-noise ratio (SNR), which is not suitable for clinical use. A novel deep learning-based technique has been proposed to denoise acoustic signals and reduce BP range uncertainty with much lower doses. Three accelerometers were placed on the distal surface of a cylindrical polyethylene (PE) phantom to collect protoacoustic signals. In total, 512 raw signals were collected at each device. Device-specific stack autoencoder (SAE) denoising models were trained to denoise the noise-containing input signals, which were generated by averaging only 1, 2, 4, 8, 16, or 24 raw signals (low NSA signals), while the clean signals were obtained by averaging 192 raw signals (high NSA). Both supervised and unsupervised training strategies were employed, and the evaluation of the models was based on mean squared error (MSE), SNR, and BP range uncertainty. Overall, the supervised SAEs outperformed the unsupervised SAEs in BP range verification. For the high accuracy detector, it achieved a BP range uncertainty of 0.20 ± 3.44 mm by averaging over 8 raw signals, while for the other two low accuracy detectors, they achieved the BP uncertainty of 1.44 ± 6.45 mm and -0.23 ± 4.88 mm by averaging 16 raw signals, respectively. This deep learning-based denoising method has shown promising results in enhancing the SNR of protoacoustic measurements and improving the accuracy in BP range verification. It greatly reduces the dose and time for potential clinical applications.


Assuntos
Aprendizado Profundo , Terapia com Prótons , Prótons , Dosagem Radioterapêutica , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
9.
Int J Radiat Oncol Biol Phys ; 116(2): 295-304, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-35235854

RESUMO

PURPOSE: The American Association of Physicists in Medicine (AAPM) shares the results, conclusions, and recommendations from the initial Equity, Diversity, and Inclusion Climate Survey conducted in 2021. METHODS AND MATERIALS: The climate survey targeted medical physicists who are full members of the AAPM and included demographic inquiries and questions intended to assess the working environmental climate in terms of a sense of belonging and inclusion, experiences of discrimination and harassment, and obstacles to participation within the AAPM. The survey invitation was sent to 5,500 members. Responses were collected from 1385 members (response rate of 25%) between January and February 2021. RESULTS: Overall, the medical physics workplace climate was positive. However, some demographic and professional subgroups reported lower levels of agreement with positive characteristics of their workplace climates. Compared with men, women ranked lower 7 of 8 categories that characterized the workplace climate. Other subgroups that also ranked the workplace climate descriptors lower included individuals not originally from the United States and Canada (3/8). Most respondents strongly agreed/agreed that the climate within the AAPM was welcoming. However, 17% of respondents reported personally experiencing or witnessing microaggressions within the AAPM. Overall, medical physicists reported low levels of agreement that opportunities within the AAPM were available to them, from 34% to 60% among 8 categories, including opportunities to volunteer, join committees, and compete for leadership positions within the AAPM. Several subgroups reported even lower levels of agreement that these opportunities are available. Asian and Asian American respondents (3/8) and physicists with origins in countries outside the United States and Canada (7/8) reported fewer opportunities to participate in the AAPM. Medical physicists reported their experiences of discrimination and sexual harassment in their workplaces and within the AAPM. For those who reported personal experiences of sexual harassment, only 24% (15/63) felt comfortable reporting when it occurred within their workplaces, and 35% (9/26) felt comfortable reporting when it occurred within the AAPM. CONCLUSIONS: The report concludes with several recommendations for action.


Assuntos
Medicina , Assédio Sexual , Masculino , Humanos , Feminino , Estados Unidos , Física Médica , Diversidade, Equidade, Inclusão , Inquéritos e Questionários
10.
Ecancermedicalscience ; 17: 1508, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37113724

RESUMO

The rising cancer incidence and mortality in sub-Saharan Africa (SSA) warrants an increased focus on adopting or developing approaches that can significantly increase access to treatment in the region. One such approach recommended by the recent Lancet Oncology Commission for sub-Saharan Africa is hypofractionated radiotherapy (HFRT), which can substantially increase access to radiotherapy by reducing the overall duration of time (in days) each person spends being treated. Here we highlight challenges in adopting such an approach identified during the implementation of the HypoAfrica clinical trial. The HypoAfrica clinical trial is a longitudinal, multicentre study exploring the feasibility of applying HFRT for prostate cancer in SSA. This study has presented an opportunity for a pragmatic assessment of potential barriers and facilitators to adopting HFRT. Our results highlight three key challenges: quality assurance, study harmonisation and machine maintenance. We describe solutions employed to resolve these challenges and opportunities for longer term solutions that can facilitate scaling-up use of HFRT in SSA in clinical care and multicentre clinical trials. This report provides a valuable reference for the utilisation of radiotherapy approaches that increase access to treatment and the conduct of high-quality large-scale/multi-centre clinical trials involving radiotherapy. Trial registration: Not available yet.

11.
Front Oncol ; 12: 1085686, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36776362

RESUMO

Despite technological advances in radiation therapy for cancer treatment, many patient populations still experience mediocre survival percentages, local control, and quality of life. Additionally, much of the world lacks access to expensive, modern treatment options. The need for innovative, cost-effective solutions that can improve patient treatment outcomes is essential. Phytomedicines have been shown to induce apoptotic tumor cell death, diminish tumor progression, reduce cancer incidence, alleviate harmful hypoxic conditions, and more. While an ample amount of research is available that characterizes many phytomedicines as having anti-cancer properties that increase tumor cell killing/control and mitigate the harmful side effects of radiation damage, little work has been done to investigate the synergistic effect of phytoradiotherapy: combining radiation treatment with phytomedicines. In this study, a protocol for testing the radiosensitizing effects of phytomedicines was validated and used to investigate the well-known plant based medicine cannabidiol (CBD) and the lesser-known medicinal fruit Bitter Melon. Additionally, based on its high concentration of plant hemoglobin which has been shown to abate hypoxia, the African-indigenous Justicia plant was tested in pancreatic adenocarcinoma mouse models. The studies reveal that these phytomedicines can effectively enhance tumor cell killing, minimize tumor growth, and prolong mice survival. There is certainly the need for additional research in this regard, however, phytoradiotherapy: the use of phytomedicines to enhance radiation therapy treatment outcomes, continues to show potential as a promising, innovative way to improve cancer care.

12.
J Radiosurg SBRT ; 8(2): 117-125, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36275137

RESUMO

In Gamma Knife (GK) radiosurgery, dose rate decreases during the life cycle of its radiation source, extending treatment times. Prolonged treatments influence the amount of sublethal radiation injury that is repaired during exposure, and is associated with decreased biologically-equivalent dose (BED). We assessed the impact of treatment times on clinical outcomes following GK of the trigeminal nerve - a rare clinical model to isolate the effects of treatment times. This is a retrospective analysis of 192 patients with facial pain treated across three source exchanges. All patients were treated to 80 Gy with a single isocenter. Treatment time was analyzed in terms of patient anatomy-specific dose rate, as well as BED calculated from individual patient beam-on times. An outcome tool measuring pain in three distinct domains (pain intensity, interference with general and oro-facial activities of daily living), was administered before and after intervention. Multivariate linear regression was performed with dose rate/BED, brainstem dose, sex, age, diagnosis, and prior intervention as predictors. BED was an independent predictor of the degree of improvement in all three dimensions of pain severity. A decrease in dose rate by 1.5 Gy/min corresponded to 31.8% less improvement in the overall severity of pain. Post-radiosurgery incidence of facial numbness was increased for BEDs in the highest quartile. Treatment time is an independent predictor of pain outcomes, suggesting that prescription dose should be customized to ensure iso-effective treatments, while accounting for the possible increase in adverse effects at the highest BEDs.

13.
Bioorg Med Chem ; 19(13): 3929-34, 2011 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-21669536

RESUMO

Inhibition of intestinal α-glucosidases and pancreatic α-amylases is an approach to controlling blood glucose and serum insulin levels in individuals with Type II diabetes. The two human intestinal glucosidases are maltase-glucoamylase and sucrase-isomaltase. Each incorporates two family 31 glycoside hydrolases responsible for the final step of starch hydrolysis. Here we compare the inhibition profiles of the individual N- and C-terminal catalytic subunits of both glucosidases by clinical glucosidase inhibitors, acarbose and miglitol, and newly discovered glucosidase inhibitors from an Ayurvedic remedy used for the treatment of Type II diabetes. We show that features of the compounds introduce selectivity towards the subunits. Together with structural data, the results enhance the understanding of the role of each catalytic subunit in starch digestion, helping to guide the development of new compounds with subunit specific antidiabetic activity. The results may also have relevance to other metabolic diseases such as obesity and cardiovascular disease.


Assuntos
Amido/metabolismo , Complexo Sacarase-Isomaltase/metabolismo , alfa-Glucosidases/metabolismo , 1-Desoxinojirimicina/análogos & derivados , 1-Desoxinojirimicina/química , 1-Desoxinojirimicina/farmacologia , Acarbose/química , Acarbose/farmacologia , Domínio Catalítico , Inibidores Enzimáticos/química , Inibidores Enzimáticos/farmacologia , Inibidores de Glicosídeo Hidrolases , Cinética , Monossacarídeos/química , Compostos de Selênio/química , Compostos de Selênio/farmacologia , Complexo Sacarase-Isomaltase/antagonistas & inibidores , Álcoois Açúcares/química , Álcoois Açúcares/farmacologia , Sulfatos/química , Sulfatos/farmacologia
14.
Med Phys ; 48(7): 3948-3957, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33843065

RESUMO

INTRODUCTION: Ultra-high dose rate (FLASH) radiotherapy has become a popular research topic with the potential to reduce normal tissue toxicities without losing the benefit of tumor control. The development of FLASH proton pencil beam scanning (PBS) delivery requires accurate dosimetry despite high beam currents with correspondingly high ionization densities in the monitoring chamber. In this study, we characterized a newly designed high-resolution position sensing transmission ionization chamber with a purpose-built multichannel electrometer for both conventional and FLASH dose rate proton radiotherapy. METHODS: The dosimetry and positioning accuracies of the ion chamber were fully characterized with a clinical scanning beam. On the FLASH proton beamline, the cyclotron output current reached up to 350 nA with a maximum energy of 226.2 MeV, with 210 ± 3 nA nozzle pencil beam current. The ion recombination effect was characterized under various bias voltages up to 1000 V and different beam intensities. The charge collected by the transmission ion chamber was compared with the measurements from a Faraday cup. RESULTS: Cross-calibrated with an Advanced Markus chamber (PTW, Freiburg, Germany) in a uniform PBS proton beam field at clinical beam setting, the ion chamber calibration was 38.0 and 36.7 GyE·mm2 /nC at 100 and 226.2 MeV, respectively. The ion recombination effect increased with larger cyclotron current at lower bias voltage while remaining ≤0.5 ± 0.5% with ≥200 V of bias voltage. Above 200 V, the normalized ion chamber readings demonstrated good linearity with the mass stopping power in air for both clinical and FLASH beam intensities. The spot positioning accuracy was measured to be 0.10 ± 0.08 mm in two orthogonal directions. CONCLUSION: We characterized a transmission ion chamber system under both conventional and FLASH beam current densities and demonstrated its suitability for use as a proton pencil beam dose and spot position delivery monitor under FLASH dose rate conditions.


Assuntos
Terapia com Prótons , Prótons , Alemanha , Radiometria , Dosagem Radioterapêutica
15.
Radiat Environ Biophys ; 49(4): 715-21, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20725839

RESUMO

As a part of the near solar system exploration program, astronauts may receive significant total body proton radiation exposures during a solar particle event (SPE). In the Center for Acute Radiation Research (CARR), symptoms of the acute radiation sickness syndrome induced by conventional radiation are being compared to those induced by SPE-like proton radiation, to determine the relative biological effectiveness (RBE) of SPE protons. In an SPE, the astronaut's whole body will be exposed to radiation consisting mainly of protons with energies below 50 MeV. In addition to providing for a potentially higher RBE than conventional radiation, the energy distribution for an SPE will produce a relatively inhomogeneous total body dose distribution, with a significantly higher dose delivered to the skin and subcutaneous tissues than to the internal organs. These factors make it difficult to use a (60)Co standard for RBE comparisons in our experiments. Here, the novel concept of using megavoltage electron beam radiation to more accurately reproduce both the total dose and the dose distribution of SPE protons and make meaningful RBE comparisons between protons and conventional radiation is described. In these studies, Monte Carlo simulation was used to determine the dose distribution of electron beam radiation in small mammals such as mice and ferrets as well as large mammals such as pigs. These studies will help to better define the topography of the time-dose-fractionation versus biological response landscape for astronaut exposure to an SPE.


Assuntos
Atividade Solar , Animais , Radioisótopos de Cobalto/análise , Simulação por Computador , Relação Dose-Resposta à Radiação , Elétrons , Humanos , Camundongos , Imagens de Fantasmas , Prótons , Monitoramento de Radiação , Software , Suínos , Água/química , Irradiação Corporal Total
16.
Front Oncol ; 10: 624663, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33628736

RESUMO

Radiotherapy (RT) is an effective method of cancer treatment, but like any other method of cancer treatment, there are inherent limitations. While technological advances and a growing understanding of its biological effects have improved its results dramatically, the use of RT is still limited to certain patient populations and by normal tissue toxicities. The harmful side effects of treating patients with radiation can offset its therapy benefits, limiting its use in certain cases. Phyto, or plant-based, medicines offer a way to add to radiation treatment, while also protecting patients from its toxic side effects. Phytomedicines such as cannabinoids (CBD) and bitter melon extract have demonstrated therapeutic properties, including the ability to activate apoptotic death in cancer cells, diminish tumor progression, and generally decrease the incidence of several cancer types. In addition, herbal drugs have been shown to be powerful antioxidants with the ability to decrease toxicity of RT without the adverse side effects found in synthetic drugs. Furthermore, a number of phytomedicines have been shown to mitigate hypoxic conditions within the tumor microenvironment, creating a more radiosensitive disease and preventing tumorigenesis. The purpose of this article is to examine the merits and demerits of employing phytomedicines during RT. Results from studies that have tested the effects of combining radiotherapy with supplemental herbal treatment are discussed along with perspectives on where additional research is needed to advance "Phytoradiotherapy". Overall, experimental evidence points to the fact that phytomedicines have significant potential to enhance RT, with need for cross-disciplinary collaborations to establish optimal dosing combinations with evidence-base for clinical translation.

17.
Nutrition ; 78: 110857, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32599415

RESUMO

OBJECTIVES: Maltase-glucoamylase (Mgam) and sucrase-isomaltase (Si) are mucosal α-glucosidases required for the digestion of starch to glucose. We hypothesized that a dietary approach to reduce Mgam and Si activities can reduce glucose generation and absorption, and improve glucose control. METHODS: Rice starch was entrapped in alginate microspheres to moderate in vitro digestion properties. Three groups of 8-wk old mice (n = 8) were conditioned for 7 d with low 13C-starch-based materials differing in digestion rates (fast, slow, and slower), and then given a digestible 13C-labeled cornstarch test feeding to determine its digestion to glucose. RESULTS: Conditioning of the small intestine with the slowly digestible starches for 7 d reduced jejunal α-glucosidase and sucrase activities, as well as glucose absorption for the slowly digestible starch slower group (P < 0.01). A correlative relationship was found between glucose absorption from a cornstarch test feeding given at d 7 and jejunal α-glucosidase and sucrase activities (R2 = 0.64; 0.67). However, total prandial glucose levels during the 2-h feeding period did not differ. CONCLUSIONS: Decreased glucogenesis from a digestible starch feeding was found in mice conditioned on slowly digestible starch diets, suggesting that a dietary approach incorporating slowly digestible starches may change α-glucosidase activities to moderate glucose absorption rate.


Assuntos
Digestão , alfa-Glucosidases , Animais , Dieta , Glucose , Camundongos , Amido
18.
Br J Radiol ; 93(1107): 20190879, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31804145

RESUMO

OBJECTIVE: Locally recurrent disease is of increasing concern in (non-)small cell lung cancer [(N)SCLC] patients. Local reirradiation with photons or particles may be of benefit to these patients. In this multicentre in silico trial performed within the Radiation Oncology Collaborative Comparison (ROCOCO) consortium, the doses to the target volumes and organs at risk (OARs) were compared when using several photon and proton techniques in patients with recurrent localised lung cancer scheduled to undergo reirradiation. METHODS: 24 consecutive patients with a second primary (N)SCLC or recurrent disease after curative-intent, standard fractionated radio(chemo)therapy were included in this study. The target volumes and OARs were centrally contoured and distributed to the participating ROCOCO sites. Remaining doses to the OARs were calculated on an individual patient's basis. Treatment planning was performed by the participating site using the clinical treatment planning system and associated beam characteristics. RESULTS: Treatment plans for all modalities (five photon and two proton plans per patient) were available for 22 patients (N = 154 plans). 3D-conformal photon therapy and double-scattered proton therapy delivered significantly lower doses to the target volumes. The highly conformal techniques, i.e., intensity modulated radiation therapy (IMRT), volumetric modulated arc therapy (VMAT), CyberKnife, TomoTherapy and intensity-modulated proton therapy (IMPT), reached the highest doses in the target volumes. Of these, IMPT was able to statistically significantly decrease the radiation doses to the OARs. CONCLUSION: Highly conformal photon and proton beam techniques enable high-dose reirradiation of the target volume. They, however, significantly differ in the dose deposited in the OARs. The therapeutic options, i.e., reirradiation or systemic therapy, need to be carefully weighed and discussed with the patients. ADVANCES IN KNOWLEDGE: Highly conformal photon and proton beam techniques enable high-dose reirradiation of the target volume. In light of the abilities of the various highly conformal techniques to spare specific OARs, the therapeutic options need to be carefully weighed and patients included in the decision-making process.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Recidiva Local de Neoplasia/radioterapia , Órgãos em Risco/efeitos da radiação , Fótons/uso terapêutico , Terapia com Prótons/métodos , Reirradiação/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Conjuntos de Dados como Assunto , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Órgãos em Risco/diagnóstico por imagem , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos , Resultado do Tratamento
19.
Int J Radiat Oncol Biol Phys ; 106(2): 440-448, 2020 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-31928642

RESUMO

PURPOSE: Recent studies suggest that ultrahigh-dose-rate, "FLASH," electron radiation therapy (RT) decreases normal tissue damage while maintaining tumor response compared with conventional dose rate RT. Here, we describe a novel RT apparatus that delivers FLASH proton RT (PRT) using double scattered protons with computed tomography guidance and provide the first report of proton FLASH RT-mediated normal tissue radioprotection. METHODS AND MATERIALS: Absolute dose was measured at multiple depths in solid water and validated against an absolute integral charge measurement using a Faraday cup. Real-time dose rate was obtained using a NaI detector to measure prompt gamma rays. The effect of FLASH versus standard dose rate PRT on tumors and normal tissues was measured using pancreatic flank tumors (MH641905) derived from the KPC autochthonous PanCa model in syngeneic C57BL/6J mice with analysis of fibrosis and stem cell repopulation in small intestine after abdominal irradiation. RESULTS: The double scattering and collimation apparatus was dosimetrically validated with dose rates of 78 ± 9 Gy per second and 0.9 ± 0.08 Gy per second for the FLASH and standard PRT. Whole abdominal FLASH PRT at 15 Gy significantly reduced the loss of proliferating cells in intestinal crypts compared with standard PRT. Studies with local intestinal irradiation at 18 Gy revealed a reduction to near baseline levels of intestinal fibrosis for FLASH-PRT compared with standard PRT. Despite this difference, FLASH-PRT did not demonstrate tumor radioprotection in MH641905 pancreatic cancer flank tumors after 12 or 18 Gy irradiation. CONCLUSIONS: We have designed and dosimetrically validated a FLASH-PRT system with accurate control of beam flux on a millisecond time scale and online monitoring of the integral and dose delivery time structure. Using this system, we found that FLASH-PRT decreases acute cell loss and late fibrosis after whole-abdomen and focal intestinal RT, whereas tumor growth inhibition is preserved between the 2 modalities.


Assuntos
Órgãos em Risco/efeitos da radiação , Terapia com Prótons/instrumentação , Lesões Experimentais por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Radioterapia Guiada por Imagem/instrumentação , Abdome/efeitos da radiação , Animais , Proliferação de Células/efeitos da radiação , Desenho de Equipamento/métodos , Estudos de Viabilidade , Feminino , Fibrose , Raios gama , Intestino Delgado/patologia , Intestino Delgado/efeitos da radiação , Camundongos , Camundongos Endogâmicos C57BL , Tratamentos com Preservação do Órgão/instrumentação , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco/patologia , Neoplasias Pancreáticas/radioterapia , Terapia com Prótons/métodos , Proteção Radiológica/métodos , Radiometria/métodos , Radioterapia Guiada por Imagem/métodos , Espalhamento de Radiação , Células-Tronco/efeitos da radiação , Tomografia Computadorizada por Raios X
20.
Radiat Prot Dosimetry ; 131(2): 167-79, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18487617

RESUMO

The University of Pennsylvania is building a proton therapy facility in collaboration with Walter Reed Army Medical Center. The proposed facility has four gantry rooms, a fixed beam room and a research room, and will use a cyclotron as the source of protons. In this study, neutron shielding considerations for the proposed proton therapy facility were investigated using analytical techniques and Monte Carlo simulated neutron spectra. Neutron spectra calculations were done using the GEANT4 (v6.2) simulation code for various materials: water, carbon, iron, nickel and tantalum to estimate the neutron production at proton beam energies of 100, 175 and 250 MeV. Dose equivalent calculations were performed using analytical methods at various critical points within the facility, by folding the GEANT4 produced neutron spectra with dose equivalent rate data from the National Council on Radiation Protection and Measurements (NCRP) Report #144.


Assuntos
Arquitetura de Instituições de Saúde/métodos , Nêutrons , Terapia com Prótons , Proteção Radiológica , Radioterapia de Alta Energia , Algoritmos , Simulação por Computador , Ciclotrons , Arquitetura de Instituições de Saúde/normas , Humanos , Método de Monte Carlo , Exposição Ocupacional , Doses de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA