Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Haematol ; 113(1): 110-116, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38566462

RESUMO

OBJECTIVES: Based on a previous phase 1 study, total marrow irradiation (TMI) at 9Gy was added to a myeloablative FluBu4 conditioning regimen in allogeneic hematopoietic stem cell transplantation (HSCT) for myeloid malignancies. Here, we report on the long-term toxicity of TMI combined with FluBu4 and compare it to patients who received only FluBu4. METHODS: We retrospectively analyzed 38 consecutive patients conditioned with FluBu4/TMI (n = 15) or FluBu4 (n = 23, control group) who had at least 1 year follow-up post-transplant. The rate of long-term adverse events that have been previously associated with total body irradiation (TBI) was analyzed in the two groups. RESULTS: The baseline characteristics did not differ between the two groups. The control group had a longer median follow-up (71.2 mo) than the TMI group (38.5 mo) (p = .004). The most common adverse events were xerostomia, dental complications, cataracts, or osteopenia and did not differ between the two groups. Cognitive dysfunction or noninfectious pneumonitis, often detected after high dose TBI, were also not different in the two groups (p = .12 and p = .7, respectively). There was no grade 4 adverse event. CONCLUSION: Our results suggest that a conditioning regimen with TMI 9Gy and FluBu4 does not increase long-term adverse events after allogeneic HSCT.


Assuntos
Bussulfano , Transplante de Células-Tronco Hematopoéticas , Agonistas Mieloablativos , Condicionamento Pré-Transplante , Transplante Homólogo , Vidarabina , Humanos , Condicionamento Pré-Transplante/efeitos adversos , Condicionamento Pré-Transplante/métodos , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Transplante de Células-Tronco Hematopoéticas/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Vidarabina/análogos & derivados , Vidarabina/administração & dosagem , Vidarabina/efeitos adversos , Bussulfano/efeitos adversos , Bussulfano/administração & dosagem , Estudos Retrospectivos , Agonistas Mieloablativos/efeitos adversos , Agonistas Mieloablativos/uso terapêutico , Agonistas Mieloablativos/administração & dosagem , Irradiação Corporal Total/efeitos adversos , Adulto Jovem , Seguimentos , Medula Óssea/efeitos da radiação , Medula Óssea/efeitos dos fármacos , Idoso , Adolescente
2.
J Appl Clin Med Phys ; 21(3): 184-191, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31981305

RESUMO

BACKGROUND: Fiducial markers are frequently used before treatment for image-guided patient setup in radiation therapy (RT), but can also be used during treatment for image-guided intrafraction motion detection. This report describes our implementation of automatic marker detection with periodic kV imaging (TrueBeam v2.5) to monitor and correct intrafraction motion during prostate RT. METHODS: We evaluated the reproducibility and accuracy of software fiducial detection using a phantom with 3 implanted fiducial markers. Clinical implementation for patients with intraprostatic fiducials receiving volumetric modulated arc therapy (VMAT) utilized periodic on-board kV imaging with 10 s intervals during treatment delivery. For each image, the software automatically identified fiducial locations and determined whether their distance relative to planned locations were within a 3 mm tolerance. Motion was corrected if either ≥2 fiducials in a single image or ≥1 fiducial in sequential images were out of tolerance. RESULTS: Phantom studies demonstrated poorer performance of linear fiducials compared to collapsible fiducials, and wide variability to accurately detect fiducials across eight software settings. For any given setting, results were relatively reproducible and precise to ~0.5 mm. Across 17 patients treated with a median of 20 fractions, the software recommended a shift in 44% of fractions, and a shift was actually implemented after visual confirmation of movement greater than the 3 mm threshold in 20% of fractions. Adjustment of our approach led to improved accuracy for the latter (n = 7) patient subset. On average, table repositioning added 3.0 ± 0.3 min to patient time on table. Periodic kV imaging increased skin dose by an estimated 1 cGy per treatment arc. CONCLUSIONS: Periodic kV imaging with automatic detection of motion during VMAT prostate treatments is commercially available, and can be successfully implemented to mitigate effects of intrafraction motion with careful attention to software settings.


Assuntos
Marcadores Fiduciais , Movimento , Imagens de Fantasmas , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Software , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Órgãos em Risco/efeitos da radiação , Neoplasias da Próstata/metabolismo , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
3.
J Appl Clin Med Phys ; 20(8): 21-28, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31328368

RESUMO

Single-isocenter volumetric modulated arc therapy (VMAT) technique can provide stereotactic radiosurgery (SRS) treatment with improved delivery efficiency for treating multiple metastases. Nevertheless, planning is time consuming and verification of frame-based SRS setup, especially at noncoplanar angles, can be challenging. We report on a single-isocenter VMAT technique with a special focus on improving treatment workflow and delivery verification to exploit the minimized patient motion of the frame-based SRS. We developed protocols for preplanning and verification for VMAT and evaluated them for ten patient cases. Preplans based on MRI were used to generate comparable treatment plans using CT taken on the day of treatment after frame placement. Target positioning accuracy was evaluated by stereoscopic in-room kV imaging. Dosimetric accuracy of the noncoplanar plan delivery was validated using measurement-guided 3D dose reconstruction as well as film-based end-to-end test with a Rando phantom. Average absolute differences of homogeneity indices, conformity indices, and V12Gy between MR preplans and CT-based plans were within 5%. In-room imaging positioning accuracy of 0.4 mm was verified to be independent of the distance to the isocenter. For treatment verification, average local and global passing rates of the 3D gamma (1 mm, 3%) were 86% and 99%, respectively. D99 values were matched within 5% for individual target structures (>0.5 cc). Additional film analysis confirmed dosimetric accuracy for small targets that had large verification errors in the 3D dose reconstruction. Our results suggest that the advantages of frame-based SRS and noncoplanar single-isocenter VMAT technique can be combined for efficient and accurate treatment of patients with multiple metastases.


Assuntos
Neoplasias Encefálicas/secundário , Neoplasias Encefálicas/cirurgia , Imageamento por Ressonância Magnética/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Órgãos em Risco/efeitos da radiação , Prognóstico , Dosagem Radioterapêutica
4.
J Appl Clin Med Phys ; 17(3): 171-179, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167274

RESUMO

Frame-based stereotactic radiosurgery (SRS) requires fixation of an invasive head ring to ensure accurate targeting. Minimizing waiting time with a fixed head ring is important for patient comfort and satisfaction. We report a practical preplanning solution for the Brainlab iPlan treatment planning system that reduces waiting time by expediting the planning process on treatment day. A water-filled anthropomorphic head phantom was used to acquire a surrogate CT image set for preplanning and fused with patient's MRI, which was obtained before the day of treatment. Once an acceptable preplan was obtained, it was saved as a plan template and the phantom image set was removed from the Brainlab database to prevent any confusion and mix-up of image sets. On the treatment day, the patient's CT and MRI were fused, and the customized beam settings of the preplan template were then applied and optimized. Up to 10-fold of reduction in treatment plan time was demonstrated by bench testing with multiple planners and a variety of cases. Loading the plan template and fine-tuning the preconfigured beam settings took only a small fraction of the preplan time to restore the conformity and dose falloff comparable to those of the preplan. For instance, preplan time was 2 hr for a two-isocenter case, whereas, it took less than 20 min for a less experienced planner to plan it on the day of treat-ment using the preplan method. The SRS preplanning technique implemented in this study for the Brainlab iPlan treatment planning system offers an opportunity to explore possible beam configurations thoroughly, optimize planning parameters, resolve gantry angle clearance issues, and communicate and address challenges with physicians before the treatment day. Preplanning has been proven to improve plan quality and to improve efficiency in our clinic, especially for multiple-isocenter and dosimetrically challenging cases.


Assuntos
Neoplasias Encefálicas/cirurgia , Cabeça/cirurgia , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Radiocirurgia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias Encefálicas/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Humanos , Dosagem Radioterapêutica , Fluxo de Trabalho
5.
Am J Respir Cell Mol Biol ; 53(4): 555-62, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26426981

RESUMO

Radiation-induced pulmonary fibrosis (RIF) is a severe complication of thoracic radiotherapy that limits its dose, intensity, and duration. The contribution of the endocannabinoid signaling system in pulmonary fibrogenesis is not known. Using a well-established mouse model of RIF, we assessed the involvement of cannabinoid receptor-1 (CB1) in the onset and progression of pulmonary fibrosis. Female C57BL/6 mice and CB1 knockout mice generated on C57BL/6 background received 20 Gy (2 Gy/min) single-dose thoracic irradiation that resulted in pulmonary fibrosis and animal death within 15 to 18 weeks. Some C57BL/6 animals received the CB1 peripherally restricted antagonist AM6545 at 1 mg/kg intraperitoneally three times per week. Animal survival and parameters of pulmonary inflammation and fibrosis were evaluated. Thoracic irradiation (20 Gy) was associated with marked pulmonary inflammation and fibrosis in mice and high mortality within 15 to 18 weeks after exposure. Genetic deletion or pharmacological inhibition of CB1 receptors with a peripheral CB1 antagonist AM6545 markedly attenuated or delayed the lung inflammation and fibrosis and increased animal survival. Our results show that CB1 signaling plays a key pathological role in the development of radiation-induced pulmonary inflammation and fibrosis, and peripherally restricted CB1 antagonists may represent a novel therapeutic approach against this devastating complication of radiotherapy/irradiation.


Assuntos
Morfolinas/farmacologia , Fibrose Pulmonar/prevenção & controle , Pirazóis/farmacologia , Lesões Experimentais por Radiação/prevenção & controle , Protetores contra Radiação/farmacologia , Receptor CB1 de Canabinoide/antagonistas & inibidores , Animais , Avaliação Pré-Clínica de Medicamentos , Feminino , Deleção de Genes , Camundongos Endogâmicos C57BL , Morfolinas/uso terapêutico , Fibrose Pulmonar/metabolismo , Pirazóis/uso terapêutico , Lesões Experimentais por Radiação/metabolismo , Tolerância a Radiação , Protetores contra Radiação/uso terapêutico , Receptor CB1 de Canabinoide/genética , Receptor CB1 de Canabinoide/metabolismo
6.
J Appl Clin Med Phys ; 16(3): 4930, 2015 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103472

RESUMO

The purpose of this study was to evaluate the increased dose near the skin from an electromagnetic surface beacon transponder, which is used for localization and tracking organ motion. The bolus effect due to the copper coil surface beacon was evaluated with radiographic film measurements and Monte Carlo simulations. Various beam incidence angles were evaluated for both 6 MV and 18 MV experimentally. We performed simulations using a general-purpose Monte Carlo code MCNPX (Monte Carlo N-Particle) to supplement the experimental data. We modeled the surface beacon geometry using the actual mass of the glass vial and copper coil placed in its L-shaped polyethylene terephthalate tubing casing. Film dosimetry measured factors of 2.2 and 3.0 enhancement in the surface dose for normally incident 6 MV and 18 MV beams, respectively. Although surface dose further increased with incidence angle, the relative contribution from the bolus effect was reduced at the oblique incidence. The enhancement factors were 1.5 and 1.8 for 6 MV and 18 MV, respectively, at an incidence angle of 60°. Monte Carlo simulation confirmed the experimental results and indicated that the epidermal skin dose can reach approximately 50% of the dose at dmax at normal incidence. The overall effect could be acceptable considering the skin dose enhancement is confined to a small area (~ 1 cm2), and can be further reduced by using an opposite beam technique. Further clinical studies are justified in order to study the dosimetric benefit versus possible cosmetic effects of the surface beacon. One such clinical situation would be intact breast radiation therapy, especially large-breasted women.


Assuntos
Absorção de Radiação , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/instrumentação , Radioterapia Conformacional/instrumentação , Fenômenos Fisiológicos da Pele , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Doses de Radiação , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores
7.
Biol Blood Marrow Transplant ; 20(12): 2034-41, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25234438

RESUMO

Here we examined the addition of intensity-modulated total marrow irradiation (TMI) delivered using a linear accelerator to a myeloablative chemotherapy conditioning regimen before allogeneic hematopoietic stem cell transplantation (HSCT). In this phase I study, we enrolled 14 patients with high-risk hematologic malignancies who received escalating doses of TMI at 3 Gy (n = 3), 6 Gy (n = 3), 9 Gy (n = 6), and 12 Gy (n = 2) in combination with intravenous (i.v.) fludarabine 160 mg/m(2) and targeted busulfan (area under the curve, 4800 µM*minute). Peripheral blood mobilized stem cells were obtained from HLA-matched related (n = 9) or unrelated (n = 4) or 1 antigen-mismatched unrelated (n = 1) donors. All patients rapidly engrafted and recovered their immune cells. Overall, Bearman extrahematologic toxicity were limited to grades 1 or 2, with oral mucositis grade 1 in 64% and grade 2 in 36% of the patients. With a median follow-up of 1126 days (range, 362 to 1469) for living patients, the overall survival was 50% and relapse-free survival was 43%. Of 7 deaths, 3 were due to relapse and 4 to transplantation-related complications. We conclude that 9 Gy TMI can be combined with myeloablative chemotherapy in the design of new preparative regimens for HSCT. This study was registered at clinicaltrials.gov as NCT00988013.


Assuntos
Neoplasias Hematológicas/terapia , Transplante de Células-Tronco Hematopoéticas , Transplante de Células-Tronco de Sangue Periférico , Condicionamento Pré-Transplante/métodos , Doadores não Relacionados , Adulto , Idoso , Aloenxertos , Bussulfano/administração & dosagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Agonistas Mieloablativos/administração & dosagem , Irradiação Corporal Total
8.
Tumour Biol ; 35(3): 2403-15, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24241898

RESUMO

Our previous studies demonstrate that A549, a human lung adenocarcinoma line, could be adapted to the free radical nitric oxide (NO([Symbol: see text])). NO([Symbol: see text]) has been shown to be overexpressed in human tumors. The original cell line, A549 (parent), and the newly adapted A549-HNO (which has a more aggressive phenotype) serves as a useful model system to study the role of NO([Symbol: see text]) in tumor biology. It is well known that DNA damage response (DDR) is altered in cancer cells and NO([Symbol: see text]) is known to cause DNA damage. Modulations in molecular mechanisms involved in DNA damage response in A549-HNO cells can provide better insights into the enhanced growth behavior of these cells. Thus, here, we carried out a series of time course experiments by treating A549 and A549-HNO cells with NO([Symbol: see text]) donor and examining levels of proteins involved in the DDR pathway. We observed induced expression of key components of DDR pathway in A549-HNO cells. The HNO cells showed sustained expression of key proteins involved in both nonhomologous end joining (NHEJ) and homologous recombination pathways, whereas parent cells only expressed low levels of NHEJ pathway proteins. Further with prolonged NO([Symbol: see text]) exposure, ATR, Chk1, and p53 were activated and upregulated in HNO cells. Activation of p53 results in inhibition of apoptosis through induced Mcl1 expression. It also leads to cell cycle modulation. Interestingly, several reports show that cancer stem cells have enhanced expression of proteins involved in DNA damage response and also activated an antiapoptotic response. Our results here suggest that our HNO adapted A549 cells have increased activation of DNA damage response pathway proteins which can lead to better DNA repair function. Enhanced DDR leads to activation of antiapoptosis response and modulation in the cell cycle which may lead to better survival of these cells under harsh conditions. Thus, our present investigation further supports the hypothesis that HNO exposure leads to survival of these cells.


Assuntos
Adaptação Fisiológica/fisiologia , Adenocarcinoma/metabolismo , Apoptose/fisiologia , Dano ao DNA , Reparo do DNA/fisiologia , Neoplasias Pulmonares/metabolismo , Óxido Nítrico/metabolismo , Transdução de Sinais , Adenocarcinoma/genética , Adenocarcinoma de Pulmão , Linhagem Celular Tumoral , Dano ao DNA/fisiologia , Humanos , Immunoblotting , Neoplasias Pulmonares/genética , Análise de Sequência com Séries de Oligonucleotídeos , Transdução de Sinais/fisiologia
9.
Front Artif Intell ; 7: 1329737, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38646416

RESUMO

Background and purpose: We proposed an artificial neural network model to predict radiobiological parameters for the head and neck squamous cell carcinoma patients treated with radiation therapy. The model uses the tumor specification, demographics, and radiation dose distribution to predict the tumor control probability and the normal tissue complications probability. These indices are crucial for the assessment and clinical management of cancer patients during treatment planning. Methods: Two publicly available datasets of 31 and 215 head and neck squamous cell carcinoma patients treated with conformal radiation therapy were selected. The demographics, tumor specifications, and radiation therapy treatment parameters were extracted from the datasets used as inputs for the training of perceptron. Radiobiological indices are calculated by open-source software using dosevolume histograms from radiation therapy treatment plans. Those indices were used as output in the training of a single-layer neural network. The distribution of data used for training, validation, and testing purposes was 70, 15, and 15%, respectively. Results: The best performance of the neural network was noted at epoch number 32 with the mean squared error of 0.0465. The accuracy of the prediction of radiobiological indices by the artificial neural network in training, validation, and test phases were determined to be 0.89, 0.87, and 0.82, respectively. We also found that the percentage volume of parotid inside the planning target volume is the significant parameter for the prediction of normal tissue complications probability. Conclusion: We believe that the model has significant potential to predict radiobiological indices and help clinicians in treatment plan evaluation and treatment management of head and neck squamous cell carcinoma patients.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38082949

RESUMO

Accurate segmentation of organs-at-risks (OARs) is a precursor for optimizing radiation therapy planning. Existing deep learning-based multi-scale fusion architectures have demonstrated a tremendous capacity for 2D medical image segmentation. The key to their success is aggregating global context and maintaining high resolution representations. However, when translated into 3D segmentation problems, existing multi-scale fusion architectures might underperform due to their heavy computation overhead and substantial data diet. To address this issue, we propose a new OAR segmentation framework, called OARFocalFuseNet, which fuses multi-scale features and employs focal modulation for capturing global-local context across multiple scales. Each resolution stream is enriched with features from different resolution scales, and multi-scale information is aggregated to model diverse contextual ranges. As a result, feature representations are further boosted. The comprehensive comparisons in our experimental setup with OAR segmentation as well as multi-organ segmentation show that our proposed OARFocalFuseNet outperforms the recent state-of-the-art methods on publicly available OpenKBP datasets and Synapse multi-organ segmentation. Both of the proposed methods (3D-MSF and OARFocalFuseNet) showed promising performance in terms of standard evaluation metrics. Our best performing method (OARFocalFuseNet) obtained a dice coefficient of 0.7995 and hausdorff distance of 5.1435 on OpenKBP datasets and dice coefficient of 0.8137 on Synapse multi-organ segmentation dataset. Our code is available at https://github.com/NoviceMAn-prog/OARFocalFuse.


Assuntos
Órgãos em Risco , Tomografia Computadorizada por Raios X , Tomografia Computadorizada por Raios X/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
11.
Nanomaterials (Basel) ; 13(11)2023 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-37299694

RESUMO

Although radiotherapy is one of the most important curative treatments for cancer, its clinical application is associated with undesired therapeutic effects on normal or healthy tissues. The use of targeted agents that can simultaneously achieve therapeutic and imaging functions could constitute a potential solution. Herein, we developed 2-deoxy-d-glucose (2DG)-labeled poly(ethylene glycol) (PEG) gold nanodots (2DG-PEG-AuD) as a tumor-targeted computed tomography (CT) contrast agent and radiosensitizer. The key advantages of the design are its biocompatibility and targeted AuD with excellent sensitivity in tumor detection via avid glucose metabolism. As a consequence, CT imaging with enhanced sensitivity and remarkable radiotherapeutic efficacy could be attained. Our synthesized AuD displayed linear enhancement of CT contrast as a function of its concentration. In addition, 2DG-PEG-AuD successfully demonstrated significant augmentation of CT contrast in both in vitro cell studies and in vivo tumor-bearing mouse models. In tumor-bearing mice, 2DG-PEG-AuD showed excellent radiosensitizing functions after intravenous injection. Results from this work indicate that 2DG-PEG-AuD could greatly potentiate theranostic capabilities by providing high-resolution anatomical and functional images in a single CT scan and therapeutic capability.

12.
Blood Adv ; 7(3): 285-292, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-35851593

RESUMO

Relapse after allogeneic stem cell transplantation (allo-SCT) remains the primary cause of treatment failure. A second SCT can result in long-term survival in a subset of patients, but the relapse rate remains high. We conducted a single-center, phase 1, modified 3 + 3 dose-escalation study of the feasibility of combining intensity-modulated total marrow irradiation (IM-TMI) with fludarabine and melphalan for conditioning. Between December 2015 and May 2020, 21 patients with relapsed hematologic disease undergoing second or greater allo-SCT were treated with IM-TMI doses of 6 Gy, 9 Gy, or 12 Gy. Dose-limiting toxicity was defined as a grade 3 or higher treatment-related adverse event; mucositis was the primary dose-limiting toxicity. The median times to neutrophil and platelet engraftment were 10 and 18 days, respectively. The 1-year cumulative incidence of graft-versus-host disease was 65% (95% confidence interval CI, 38-83). The nonrelapse mortality at 2 years was 17% (95% CI, 4-39). Cumulative incidence of relapse at 2 years was 35% (95% CI, 13-58). Two-year progression-free survival and overall survival were 48% and 50%. We conclude that combining IM-TMI with fludarabine-melphalan is feasible. We recommend 12 Gy of IM-TMI with fludarabine-melphalan for second SCT, although 9 Gy may be used for older or underweight patients.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica , Neoplasias Hematológicas , Transplante de Células-Tronco Hematopoéticas , Humanos , Neoplasias Hematológicas/terapia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Melfalan/uso terapêutico , Recidiva Local de Neoplasia/tratamento farmacológico , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos
13.
Front Med (Lausanne) ; 10: 1269689, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37904839

RESUMO

Background: Clinical attempts to find benefit from specifically targeting and boosting resistant hypoxic tumor subvolumes have been promising but inconclusive. While a first preclinical murine tumor type showed significant improved control with hypoxic tumor boosts, a more thorough investigation of efficacy from boosting hypoxic subvolumes defined by electron paramagnetic resonance oxygen imaging (EPROI) is necessary. The present study confirms improved hypoxic tumor control results in three different tumor types using a clonogenic assay and explores potential confounding experimental conditions. Materials and methods: Three murine tumor models were used for multi-modal imaging and radiotherapy: MCa-4 mammary adenocarcinomas, SCC7 squamous cell carcinomas, and FSa fibrosarcomas. Registered T2-weighted MRI tumor boundaries, hypoxia defined by EPROI as pO2 ≤ 10 mmHg, and X-RAD 225Cx CT boost boundaries were obtained for all animals. 13 Gy boosts were directed to hypoxic or equal-integral-volume oxygenated tumor regions and monitored for regrowth. Kaplan-Meier survival analysis was used to assess local tumor control probability (LTCP). The Cox proportional hazards model was used to assess the hazard ratio of tumor progression of Hypoxic Boost vs. Oxygenated Boost for each tumor type controlling for experimental confounding variables such as EPROI radiofrequency, tumor volume, hypoxic fraction, and delay between imaging and radiation treatment. Results: An overall significant increase in LTCP from Hypoxia Boost vs. Oxygenated Boost treatments was observed in the full group of three tumor types (p < 0.0001). The effects of tumor volume and hypoxic fraction on LTCP were dependent on tumor type. The delay between imaging and boost treatments did not have a significant effect on LTCP for all tumor types. Conclusion: This study confirms that EPROI locates resistant tumor hypoxic regions for radiation boost, increasing clonogenic LTCP, with potential enhanced therapeutic index in three tumor types. Preclinical absolute EPROI may provide correction for clinical hypoxia images using additional clinical physiologic MRI.

15.
J Lipid Res ; 53(8): 1553-68, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22615416

RESUMO

The enforcement of sphingosine-1-phosphate (S1P) signaling network protects from radiation-induced pneumonitis. We now demonstrate that, in contrast to early postirradiation period, late postirradiation sphingosine kinase-1 (SphK1) and sphingoid base-1-phosphates are associated with radiation-induced pulmonary fibrosis (RIF). Using the mouse model, we demonstrate that RIF is characterized by a marked upregulation of S1P and dihydrosphingosine-1-phosphate (DHS1P) levels in the lung tissue and in circulation accompanied by increased lung SphK1 expression and activity. Inhibition of sphingolipid de novo biosynthesis by targeting serine palmitoyltransferase (SPT) with myriocin reduced radiation-induced pulmonary inflammation and delayed the onset of RIF as evidenced by increased animal lifespan and decreased expression of markers of fibrogenesis, such as collagen and α-smooth muscle actin (α-SMA), in the lung. Long-term inhibition of SPT also decreased radiation-induced SphK activity in the lung and the levels of S1P-DHS1P in the lung tissue and in circulation. In vitro, inhibition or silencing of serine palmitoyltransferase attenuated transforming growth factor-ß1 (TGF-ß)-induced upregulation of α-SMA through the negative regulation of SphK1 expression in normal human lung fibroblasts. These data demonstrate a novel role for SPT in regulating TGF-ß signaling and fibrogenesis that is linked to the regulation of SphK1 expression and S1P-DHS1P formation.


Assuntos
Inibidores Enzimáticos/farmacologia , Ácidos Graxos Monoinsaturados/farmacologia , Regulação Enzimológica da Expressão Gênica/efeitos dos fármacos , Fosfotransferases (Aceptor do Grupo Álcool)/genética , Fibrose Pulmonar/prevenção & controle , Lesões Experimentais por Radiação/prevenção & controle , Serina C-Palmitoiltransferase/antagonistas & inibidores , Animais , Feminino , Regulação Enzimológica da Expressão Gênica/efeitos da radiação , Humanos , Camundongos , Fibrose Pulmonar/enzimologia , Fibrose Pulmonar/genética , Fibrose Pulmonar/patologia , Lesões Experimentais por Radiação/enzimologia , Lesões Experimentais por Radiação/genética , Lesões Experimentais por Radiação/patologia , Transdução de Sinais/efeitos dos fármacos , Transdução de Sinais/efeitos da radiação , Esfingosina/análogos & derivados , Esfingosina/metabolismo , Tórax/efeitos da radiação , Fatores de Tempo , Fator de Crescimento Transformador beta/metabolismo , Regulação para Cima/efeitos dos fármacos , Regulação para Cima/efeitos da radiação
16.
Med Phys ; 39(1): 281-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22225298

RESUMO

PURPOSE: Volumetric modulated arc therapy (VMAT) treatment planning studies have been reported to provide good target coverage and organs at risk (OARs) sparing in total marrow irradiation (TMI). A comprehensive dosimetric study simulating the clinical situation as close as possible is a norm in radiotherapy before a technique can be used to treat a patient. Without such a study, it would be difficult to make a reliable and safe clinical transition especially with a technique as complicated as VMAT-TMI. To this end, the dosimetric feasibility of VMAT-TMI technique in terms of treatment planning, delivery efficiency, and the most importantly three dimensional dose distribution accuracy was investigated in this study. The VMAT-TMI dose distribution inside a humanlike Rando phantom was measured and compared to the dose calculated using RapidArc especially in the field junctions and the inhomogeneous tissues including the lungs, which is the dose-limiting organ in TMI. METHODS: Three subplans with a total of nine arcs were used to treat the planning target volume (PTV), which was determined as all the bones plus the 3 mm margin. Thermoluminescent detectors (TLDs) were placed at 39 positions throughout the phantom. The measured TLD doses were compared to the calculated plan doses. Planar dose for each arc was verified using mapcheck. RESULTS: TLD readings demonstrated accurate dose delivery, with a median dose difference of 0.5% (range: -4.3% and 6.6%) from the calculated dose in the junctions and in the inhomogeneous medium including the lungs. CONCLUSIONS: The results from this study suggest that RapidArc VMAT technique is dosimetrically accurate, safe, and efficient in delivering TMI within clinically acceptable time frame.


Assuntos
Carga Corporal (Radioterapia) , Doenças da Medula Óssea/radioterapia , Radiometria/métodos , Radioterapia Conformacional/métodos , Contagem Corporal Total/métodos , Doenças da Medula Óssea/prevenção & controle , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica
17.
Front Oncol ; 12: 924961, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36330489

RESUMO

We evaluated the impact of respiratory motion on the lung dose during linac-based intensity-modulated total marrow irradiation (IMTMI) using two different approaches: (1) measurement of doses within the lungs of an anthropomorphic phantom using thermoluminescent detectors (TLDs) and (2) treatment delivery measurements using ArcCHECK where gamma passing rates (GPRs) and the mean lung doses were calculated and compared with and without motion. In the first approach, respiratory motions were simulated using a programmable motion platform by using typical published peak-to-peak motion amplitudes of 5, 8, and 12 mm in the craniocaudal (CC) direction, denoted here as M1, M2, and M3, respectively, with 2 mm in both anteroposterior (AP) and lateral (LAT) directions. TLDs were placed in five selected locations in the lungs of a RANDO phantom. Average TLD measurements obtained with motion were normalized to those obtained with static phantom delivery. The mean dose ratios were 1.01 (0.98-1.03), 1.04 (1.01-1.09), and 1.08 (1.04-1.12) for respiratory motions M1, M2, and M3, respectively. To determine the impact of directional respiratory motion, we repeated the experiment with 5-, 8-, and 12-mm motion in the CC direction only. The differences in average TLD doses were less than 1% when compared with the M1, M2, and M3 motions indicating a minimal impact from CC motion on lung dose during IMTMI. In the second experimental approach, we evaluated extreme respiratory motion 15 mm excursion in only the CC direction. We placed an ArcCHECK device on a commercial motion platform and delivered the clinical IMTMI plans of five patients. We compared, with and without motion, the dose volume histograms (DVHs) and mean lung dose calculated with the ArcCHECK-3DVH tool as well as GPR with 3%, 5%, and 10% dose agreements and a 3-mm constant distance to agreement (DTA). GPR differed by 11.1 ± 2.1%, 3.8 ± 1.5%, and 0.1 ± 0.2% with dose agreement criteria of 3%, 5%, and 10%, respectively. This indicates that respiratory motion impacts dose distribution in small and isolated parts of the lungs. More importantly, the impact of respiratory motion on the mean lung dose, a critical indicator for toxicity in IMTMI, was not statistically significant (p > 0.05) based on the Student's t-test. We conclude that most patients treated with IMTMI will have negligible dose uncertainty due to respiratory motion. This is particularly reassuring as lung toxicity is the main concern for future IMTMI dose escalation studies.

18.
Front Oncol ; 12: 942685, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36267964

RESUMO

Purpose: Total marrow irradiation (TMI) involves optimization of extremely large target volumes and requires extensive clinical experience and time for both treatment planning and delivery. Although volumetric modulated arc therapy (VMAT) achieves substantial reduction in treatment delivery time, planning process still presents a challenge due to use of multiple isocenters and multiple overlapping arcs. We developed and evaluated a knowledge-based planning (KBP) model for VMAT-TMI to address these clinical challenges. Methods: Fifty-one patients previously treated in our clinic were selected for the model training, while 22 patients from another clinic were used as a test set. All plans used a 3-isocenter to cover sub-target volumes of head and neck (HN), chest, and pelvis. Chest plan was performed first and then used as the base dose for both the HN and pelvis plans to reduce hot spots around the field junctions. This resulted in a wide range of dose-volume histograms (DVH). To address this, plans without the base-dose plan were optimized and added to the library to train the model. Results: KBP achieved our clinical goals (95% of PTV receives 100% of Rx) in a single day, which used to take 4-6 days of effort without KBP. Statistically significant reductions with KBP were observed in the mean dose values to brain, lungs, oral cavity and lenses. KBP substantially improved 105% dose spillage (14.1% ± 2.4% vs 31.8% ± 3.8%), conformity index (1.51 ± 0.06 vs 1.81 ± 0.12) and homogeneity index (1.25 ± 0.02 vs 1.33 ± 0.03). Conclusions: KBP improved dosimetric performance with uniform quality. It reduced dependence on planner experience and achieved a factor of 5 reduction in planning time to produce quality plans to allow its wide-spread clinical implementation.

19.
Tumour Biol ; 32(1): 87-98, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20963646

RESUMO

It is not understood why some head and neck squamous cell carcinomas, despite having identical morphology, demonstrate different tumor aggressiveness, including radioresistance. High levels of the free radical nitric oxide (NO) and increased expression of the NO-producing enzyme nitric oxide synthase (NOS) have been implicated in tumor progression. We previously adapted three human tongue cancer cell lines to high NO (HNO) levels by gradually exposing them to increasing concentrations of an NO donor; the HNO cells grew faster than their corresponding untreated ("parent") cells, despite being morphologically identical. Herein we initially characterize the HNO cells and compare the biological properties of the HNO and parent cells. HNO/parent cell line pairs were analyzed for cell cycle distribution, DNA damage, X-ray and ultraviolet radiation response, and expression of key cellular enzymes, including NOS, p53, glutathione S-transferase-pi (GST-pi), apurinic/apyrimidinic endonuclease-1 (APE1), and checkpoint kinases (Chk1, Chk2). While some of these properties were cell line-specific, the HNO cells typically exhibited properties associated with a more aggressive behavior profile than the parent cells (greater S-phase percentage, radioresistance, and elevated expression of GST-pi/APE1/Chk1/Chk2). To correlate these findings with conditions in primary tumors, we examined the NOS, GST-pi, and APE1 expression in human tongue squamous cell carcinomas. A majority of the clinical samples exhibited elevated expression levels of these enzymes. Together, the results herein suggest cancer cells exposed to HNO levels can develop resistance to free radicals by upregulating protective mechanisms, such as GST-pi and APE1. These upregulated defense mechanisms may contribute to their aggressive expression profile.


Assuntos
Carcinoma de Células Escamosas/patologia , Óxido Nítrico/metabolismo , Neoplasias da Língua/patologia , Adaptação Fisiológica/efeitos dos fármacos , Western Blotting , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/metabolismo , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular , Quinase 1 do Ponto de Checagem , Quinase do Ponto de Checagem 2 , DNA Liase (Sítios Apurínicos ou Apirimidínicos)/metabolismo , Glutationa S-Transferase pi/metabolismo , Humanos , Peróxido de Hidrogênio/farmacologia , Técnicas Imunoenzimáticas , Doadores de Óxido Nítrico/farmacologia , Óxido Nítrico Sintase Tipo I/metabolismo , Compostos Nitrosos/farmacologia , Oxidantes/farmacologia , Proteínas Quinases/metabolismo , Proteínas Serina-Treonina Quinases/metabolismo , Neoplasias da Língua/tratamento farmacológico , Neoplasias da Língua/metabolismo , Células Tumorais Cultivadas , Proteína Supressora de Tumor p53/metabolismo , Raios Ultravioleta , Raios X
20.
Int J Radiat Oncol Biol Phys ; 110(2): 551-565, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33373659

RESUMO

PURPOSE: Preclinical radiation replicating clinical intensity modulated radiation therapy (IMRT) techniques can provide data translatable to clinical practice. For this work, treatment plans were created for oxygen-guided dose-painting in small animals using inverse-planned IMRT. Spatially varying beam intensities were achieved using 3-dimensional (3D)-printed compensators. METHODS AND MATERIALS: Optimized beam fluence from arbitrary gantry angles was determined using a verified model of the XRAD225Cx treatment beam. Compensators were 3D-printed with varied thickness to provide desired attenuation using copper/polylactic-acid. Spatial resolution capabilities were investigated using printed test-patterns. Following American Association of Physicists in Medicine TG119, a 5-beam IMRT plan was created for a miniaturized (∼1/8th scale) C-shape target. Electron paramagnetic resonance imaging of murine tumor oxygenation guided simultaneous integrated boost (SIB) plans conformally treating tumor to a base dose (Rx1) with boost (Rx2) based on tumor oxygenation. The 3D-printed compensator intensity modulation accuracy and precision was evaluated by individually delivering each field to a phantom containing radiochromic film and subsequent per-field gamma analysis. The methodology was validated end-to-end with composite delivery (incorporating 3D-printed tungsten/polylactic-acid beam trimmers to reduce out-of-field leakage) of the oxygen-guided SIB plan to a phantom containing film and subsequent gamma analysis. RESULTS: Resolution test-patterns demonstrate practical printer resolution of ∼0.7 mm, corresponding to 1.0 mm bixels at the isocenter. The miniaturized C-shape plan provides planning target volume coverage (V95% = 95%) with organ sparing (organs at risk Dmax < 50%). The SIB plan to hypoxic tumor demonstrates the utility of this approach (hypoxic tumor V95%,Rx2 = 91.6%, normoxic tumor V95%,Rx1 = 95.7%, normal tissue V100%,Rx1 = 7.1%). The more challenging SIB plan to boost the normoxic tumor rim achieved normoxic tumor V95%,Rx2 = 90.9%, hypoxic tumor V95%,Rx1 = 62.7%, and normal tissue V100%,Rx2 = 5.3%. Average per-field gamma passing rates using 3%/1.0 mm, 3%/0.7 mm, and 3%/0.5 mm criteria were 98.8% ± 2.8%, 96.6% ± 4.1%, and 90.6% ± 5.9%, respectively. Composite delivery of the hypoxia boost plan and gamma analysis (3%/1 mm) gave passing results of 95.3% and 98.1% for the 2 measured orthogonal dose planes. CONCLUSIONS: This simple and cost-effective approach using 3D-printed compensators for small-animal IMRT provides a methodology enabling preclinical studies that can be readily translated into the clinic. The presented oxygen-guided dose-painting demonstrates that this methodology will facilitate studies driving much needed biologic personalization of radiation therapy for improvements in patient outcomes.


Assuntos
Fibrossarcoma/radioterapia , Impressão Tridimensional , Radioterapia de Intensidade Modulada/instrumentação , Animais , Cobre , Espectroscopia de Ressonância de Spin Eletrônica , Fibrossarcoma/diagnóstico por imagem , Fibrossarcoma/metabolismo , Camundongos , Tratamentos com Preservação do Órgão/métodos , Oxigênio/metabolismo , Imagens de Fantasmas , Poliésteres , Estudo de Prova de Conceito , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Hipóxia Tumoral , Filme para Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA