Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Vascular ; 31(6): 1117-1123, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35698916

RESUMO

OBJECTIVE: The optimal management for revascularization after critical limb ischemia (CLI) is controversial due to limited studies comparing long-term results of endovascular and open techniques. This study compares long-term outcomes after initial management of CLI via lower extremity bypass (LEB) and percutaneous vascular intervention (PVI). METHODS: This retrospective cohort study investigates outcomes of patients who underwent endovascular or open surgical management for CLI at a single institution from 2013-2018. All patients with diagnosis of CLI were included and separated based on initial therapy of PVI or LEB. Demographic, procedural, and follow-up data were assessed. Primary endpoints included major adverse limb events (MALE), specifically the need for major amputation and reintervention. Secondary endpoints included mortality at 30 days and one year. A multivariable Cox Proportional Hazard regression model was used to assess the relationship between Surgery group and time to MALE/death while controlling for confounding variables. RESULTS: This study identified 338 patients with an initial diagnosis of CLI who underwent either LEB (n = 108, 32%) or PVI (n = 230, 68%). The average age was 71.4, 54.4% were male, 30% were African American, 53.6% were diabetic, and 93.2% had hypertension. Patients who underwent LEB were more predominantly smokers (p = .003) and less predominantly on dialysis at time of surgery (p = .01). Re-intervention rates in the bypass group (11%) were not significantly different than the PVI group (9%; p = .95). In the bypass group, 20 (19%) patients had a major amputation with a median time of 189.5 days compared to 23 (10%) patients at a median time of 113 days in the PVI group; however, this difference was not significant (p = .16). There was no significant difference in 1-year mortality between the LEB (2%) and PVI group (4%; p = .2). The cumulative incidence of MALE/death at 30 days was 4.0% in the bypass group and 3.7% in the PVI group (p = .2). Incidences of MALE/death were 21.1% and 48.5% in the bypass group and 19.7 and 45.9% in the PVI group at one and 2 years, respectively. Intervention type was not found to be significantly associated with MALE/death after controlling for possible confounders (HR = 0.82, p = .43). CONCLUSIONS: In the initial management of CLI, there is no significant difference in long-term outcomes in terms of major amputation, need for reintervention, limb-salvage, and 1-year mortality.


Assuntos
Isquemia Crônica Crítica de Membro , Extremidade Inferior , Feminino , Humanos , Masculino , Amputação Cirúrgica , Estudos Retrospectivos , Idoso
2.
J Vasc Surg ; 76(1): 132-140, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34998943

RESUMO

OBJECTIVE: Aneurysmal extension of abdominal aortic aneurysms (AAAs) to the common iliac artery (CIA) presents a technical challenge to successful endovascular abdominal aortic aneurysm repair (EVAR). In the present study, we compared sac shrinkage and perioperative outcomes after the bell-bottom technique (BBT), internal iliac artery embolization and external iliac artery extension (EIE), and iliac branch endoprosthesis (IBE). METHODS: Using the Vascular Quality Initiative database, a retrospective analysis was conducted for patients who had undergone EVAR from 2013 to 2019. The demographic, anatomic, and perioperative data were analyzed. All patients with a proximal aortic neck length <10 mm and aortic graft diameter >32 mm were excluded from the analysis. The patients were subdivided into four groups according to the distal limb strategy: group 1, control group with a bilateral common iliac artery limb <20 mm; group 2, BBT with either a unilateral or bilateral limb >20 mm; group 3, EIE technique; and group 4, IBE. The primary endpoint was the maximal change in the aortic diameter during follow-up. The secondary endpoints included postoperative complications and the rate of endoleak. RESULTS: The records for 14,455 patients who had undergone EVAR were queried and 5788 met the anatomic criteria. The average age was 73 years, and 86.3% were men. The maximal change in the aortic diameter in the control, BBT, IBE, and EIE groups was -7.2 mm, -6.1 mm, -4.6 mm, and -6.8 mm, respectively (P = .06). The differences were not statistically significant on univariate analysis at an average follow-up of 405 days. However, on multivariable analysis (P = .01), compared with the control group, the BBT and IBE groups were 18.4% (odds ratio [OR], 0.816; 95% confidence interval [CI], 0.68-0.98) and 48.0% (OR, 0.52; 95% CI, 0.33-0.82) less likely to experience aneurysmal shrinkage, respectively. In contrast, the EIE group showed no significant difference in shrinkage compared with that in the control group. Multivariable analysis of the groups also revealed that compared directly with the BBT group, the EIE group was 69.5% more likely to have experienced shrinkage in the aortic aneurysmal diameter (OR, 1.70; 95% CI, 1.05-2.75). The BBT and IBE groups had a significantly higher rate of type II endoleaks (17.63% and 16.95%, respectively; P = .03). The EIE group had a higher rate of type Ib endoleaks (1.9%) compared with the BBT (1.1%), IBE (1.7%), and control (0.3%) groups (P = .01). No differences were found between the groups in terms of postoperative myocardial infarction (P = .47) or respiratory (P = .61) or intestinal (P = .71) complications. However, the rates of limb complications and reoperation were higher in the EIE group. CONCLUSIONS: The present study revealed that the EIE technique was more likely to demonstrate shrinkage in the aortic aneurysmal diameter than were the BBT and IBE groups compared with the control group on multivariable analysis. The EIE technique was also more likely to result in aneurysmal sac shrinkage than was the BBT group, albeit with greater rates of limb-related complications.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Aneurisma Ilíaco/complicações , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
3.
Ann Vasc Surg ; 80: 12-17, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34780942

RESUMO

BACKGROUND: Hospitalists can be instrumental in management of inpatients with multiple comorbidities requiring complex medical care such as vascular surgery patients, as well as an expertise in health care delivery. We instituted a unique hospitalist co-management program and assessed length of stay, 30-day readmission rates and mortality, and performed an overall cost-analysis. METHODS: Hospitalist co-management of vascular surgery inpatients was implemented beginning April 2019, and data was studied until March 2020. We compared this data to an eight-month period prior to implementing co-management (7/2018 - 3/2019). Patient-related outcomes that were assessed include length of stay, re-admission index, mortality index, case-mix index. Cost-analysis was performed to look at indirect and direct cost of care. RESULTS: A total of 1,062 patients were included in the study 520 pre co-management and 542 patients were post-comanagement. Baseline case-mix index was 2.47, and post-comanagement was 2.46 (P >0.05). In terms of average length of stay (aLOS), the baseline aLOS was 5.16 days per patient, while after co-management it was significantly decreased by 1.25 days to 3.91 days (P <0.05). This improvement in length of stay opened an average of 2.4 telemetry beds per day. Similarly, excess days per patient which reflects the expected length of stay based on comorbidities, improved from -0.59 to -1.65, an improvement of -1.46. CONCLUSIONS: Hospitalist co-management improves outcomes for vascular surgery inpatients, decreases length of stay, re-admission and mortality while providing a significant cost-savings. The overall average variable direct cost decreased by $1,732 per patient.


Assuntos
Médicos Hospitalares , Equipe de Assistência ao Paciente/organização & administração , Procedimentos Cirúrgicos Vasculares , Redução de Custos , Custos e Análise de Custo , Grupos Diagnósticos Relacionados , Mortalidade Hospitalar , Humanos , Tempo de Internação/estatística & dados numéricos , Cidade de Nova Iorque , Readmissão do Paciente/estatística & dados numéricos , Estudos Retrospectivos
4.
Ann Vasc Surg ; 87: 343-350, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35926790

RESUMO

BACKGROUND: In patients with abdominal aortic aneurysms, 10-20% has concomitant thoracic aortic pathologies. These are typically managed with staged endovascular aneurysm repair (EVAR) and thoracic endovascular aortic repair (TEVAR) due to a perceived higher risk of spinal cord ischemia from a simultaneous intervention. We aimed to determine the outcomes of patients undergoing simultaneous EVAR and TEVAR for concomitant aneurysms. METHODS: A retrospective cohort study was performed using the Vascular Quality Initiative registry from December 2003 to January 2021. Patients undergoing same day EVAR and TEVAR were included and analyzed in accordance with the Society for Vascular Surgery reporting standards. Primary outcomes were technical success and spinal cord ischemia. RESULTS: Simultaneous EVAR and TEVAR were performed in 25 patients. Median age was 75.0 (interquartile range [IQR], 63.0-79.0) years and 20 (80.0%) patients were male. Two (4.0%) patients were symptomatic and 4 (16.0%) presented with rupture. Median maximum infrarenal and thoracic aortic diameter was 57.0 (IQR, 52.0-65.0). Infrarenal aortic neck length was 15.0 mm (IQR, 10.0-25.0), and diameter was 27.0 mm (IQR, 24.5-30.0). Median procedure time was 185.0 min (IQR, 117.8-251.3), fluoroscopy time 32.7 min (IQR, 21.8-63.1), and contrast volume 165 mL (IQR, 115.0-207.0). There were 3 (12.0%) Type Ia endoleaks and 3 (12.0%) Type II endoleaks in EVAR's, with 1 (4.0%) Type Ia and 1 (4.0%) Type II endoleak in TEVARs. In-hospital mortality occurred in 3 (12.0%) patients (1 elective, 2 ruptures). Spinal cord ischemia occurred in 1 (4.0%) patient. This patient had a symptomatic aneurysm. Thoracic coverage extended from Zone 4 to Zone 5 and an emergent spinal drain was placed postoperatively. Symptoms were present on discharge. There was 1 (4.0%) conversion to open repair which occurred in a ruptured aneurysm. Technical success was achieved in 19 (76.0%) patients, however when excluding ruptured aneurysms, was achieved in 17 (81.0%) patients. Follow-up data was available for 19 (76.0%) patients at a median of 426.0 (IQR, 329.0-592.5) days postoperatively. A total of 3 (12.0%) patients died during the late mortality period, at a mean of 509.0 (±503.7) days. Median change in abdominal and thoracic aortic sac diameter was -1.35 mm (IQR, -11.5 to 2.5) and 8.0 (IQR, -10.5 to 12.0), respectively. CONCLUSIONS: Simultaneous EVAR and TEVAR for concomitant abdominal and thoracic aortic aneurysms can be performed with low rates of spinal cord ischemia. Short- and mid-term outcomes are acceptable.


Assuntos
Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Isquemia do Cordão Espinal , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/etiologia , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular , Procedimentos Endovasculares/efeitos adversos , Estudos Retrospectivos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Stents , Resultado do Tratamento , Fatores de Risco , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/cirurgia
5.
J Vasc Surg ; 76(2): 607-608, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35870852
6.
J Vasc Surg Venous Lymphat Disord ; 11(2): 326-330, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36183963

RESUMO

BACKGROUND: In the present study, we compared the outcomes of inferior vena cava (IVC) filter placement between the femoral vein (FV) and internal jugular (IJ) vein access sites. METHODS: We performed a retrospective study using the Vascular Quality Initiative database to assess patients who had undergone IVC filter placement from 2013 to 2019. The patients were placed into two groups according to the access site location: FV and IJ vein. The FV group included patients with access via the right and left FVs and other leg veins, and the IJ group included patients with access via the right or left IJ vein. The primary outcome was the rate of filter angulation. The secondary outcomes included access site complications such as deep vein thrombosis, hematoma, and bleeding requiring transfusion. RESULTS: Of 13,221 patients, 8214 (63%) had undergone IVC filter placement via FV access and 4789 (37%) via IJ access. The remaining 218 patients had had an unknown access site or were excluded. Within the IJ group, 4696 (98.0%) had undergone access via the right IJ and 93 (2%) via the left IJ. Within the FV (common femoral, femoral, or other infrainguinal veins) group, 7007 (85.3%) had undergone access via the right FV and 1207 (14.6%) via the left FV. The mean patient age was 63 ± 15.9 years, the mean body mass index was 30.9 ± 9.60 kg/m2, and 6788 of the patients were men (52.0%). The most common indication for filter placement was a contraindication to anticoagulation because of a recent or active bleeding episode (30%), followed by planned surgery (22%), new deep vein thrombosis/pulmonary embolism (7%), fall risk (5%), and trauma (4%). Infrarenal filters had been placed in 97.9% of the patients. Univariate analysis identified body mass index and suprarenal placement as independent risk factors for angulation. The final multivariate analysis showed a significant increase in angulation (0.9% vs 0.34%; odds ratio, 1.46; 95% confidence interval, 1.02-2.11; P = .04) and increased access site complications (0.25% vs 0.07%; odds ratio, 2.068; 95% confidence interval, 1.01-4.23; P = .048) in the FV access group. No significant correlation between the access site and retrieval rate was found (P = .9270). CONCLUSIONS: Placement of IVC filters via IJ access showed a lower rate of filter angulation in the IVC and fewer access site complications compared with FV access.


Assuntos
Embolia Pulmonar , Filtros de Veia Cava , Trombose Venosa , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Filtros de Veia Cava/efeitos adversos , Estudos Retrospectivos , Veia Cava Inferior , Resultado do Tratamento , Embolia Pulmonar/etiologia , Trombose Venosa/etiologia
7.
Innovations (Phila) ; 16(2): 136-141, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33448886

RESUMO

OBJECTIVE: In the tide of robot-assisted minimally invasive surgery, few cases of robot-assisted pneumonectomy exist in the literature. This study evaluates the perioperative outcomes and risk factors for conversion to thoracotomy with an initial robotic approach to pneumonectomy for lung cancer. METHODS: This study is a single-center retrospective review of all pneumonectomies for lung cancer with an initial robotic approach between 2015 and 2019. Patients were divided into 2 groups: surgeries completed robotically and surgeries converted to thoracotomy. Patient demographics, preoperative clinical data, surgical pathology, and perioperative outcomes were compared for meaningful differences between the groups. RESULTS: Thirteen total patients underwent robotic pneumonectomy with 8 of them completed robotically and 5 converted to thoracotomy. There were no significant differences in patient characteristics between the groups. The Robotic group had a shorter operative time (P < 0.01) and less estimated blood loss (P = 0.02). There were more lymph nodes harvested in the Robotic group (P = 0.08) but without statistical significance. There were 2 major complications in the Robotic group and none in the Conversion group. Neither tumor size nor stage were predictive of conversion to thoracotomy. Conversions decreased over time with a majority occurring in the first 2 years. There were no conversions for bleeding and no mortalities. CONCLUSIONS: Robotic pneumonectomy for lung cancer is a safe procedure and a reasonable alternative to thoracotomy. With meticulous technique, major bleeding can be avoided and most procedures can be completed robotically. Larger studies are needed to elucidate any advantages of a robotic versus open approach.


Assuntos
Neoplasias Pulmonares , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Neoplasias Pulmonares/cirurgia , Pneumonectomia , Estudos Retrospectivos , Cirurgia Torácica Vídeoassistida , Toracotomia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA