Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 60
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr ; 215: 187-191, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31587860

RESUMO

OBJECTIVE: To describe clinical presentation, electrocardiographic, and echocardiographic characteristics of carditis at the time of diagnosis of acute rheumatic fever (ARF) over a 13-year period. STUDY DESIGN: A single-center retrospective chart analysis was conducted involving all consecutive patients diagnosed with ARF between 2003 and 2015. Patient age, sex, clinical characteristics, recent medical history for group A streptococcal pharyngotonsillitis and antibiotic treatment, and laboratory, echocardiographic, and electrocardiographic findings were recorded. RESULTS: Of 98 patients (62 boys, mean age 8.81 ± 3.04 years), 59 (60.2%) reported a positive history of pharyngotonsillitis; 48 (49%) had received antibiotic (mean duration of treatment of 5.9 ± 3.1 days), and, among these, 28 (58.3%) had carditis. Carditis was the second most frequent finding, subclinical in 27% of patients. Mitral regurgitation was present in 49 of 56 patients (87.5%) and aortic regurgitation in 36/56 (64.3%) no stenosis was documented. CONCLUSIONS: ARF is still present in high-income countries and can develop despite primary prophylaxis, especially when given for a short course. Our findings highlight the need for 10 days of antistreptococcal treatment to prevent ARF. Echocardiography is important because 27% of cases with carditis were subclinical.


Assuntos
Miocardite/diagnóstico , Miocardite/epidemiologia , Febre Reumática/diagnóstico , Adolescente , Antibacterianos/uso terapêutico , Insuficiência da Valva Aórtica/diagnóstico por imagem , Artrite/microbiologia , Bloqueio Atrioventricular/diagnóstico , Sedimentação Sanguínea , Criança , Pré-Escolar , Coreia/microbiologia , Países Desenvolvidos , Ecocardiografia Doppler em Cores , Eletrocardiografia , Eritema/microbiologia , Feminino , Hemoglobinas/análise , Humanos , Itália/epidemiologia , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Faringite/epidemiologia , Estudos Retrospectivos , Febre Reumática/tratamento farmacológico , Febre Reumática/epidemiologia , Estações do Ano , Tonsilite/epidemiologia
2.
Heart Lung Circ ; 28(12): 1872-1880, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30555011

RESUMO

BACKGROUND: The extracardiac conduit technique is a valid option for completing total cavopulmonary anastomosis (TCPC) in patients with a single ventricle. The technique allows for beating heart surgery, optimal flow dynamics, and reduced postoperative atrial arrhythmia. Different types of conduit have been proposed. This study reported a single-centre experience with two different types of conduit. METHODS: Consecutive patients referred for TCPC at the current institution between January 2001 and September 2013 were included. Retrospective extraction of pertinent variables was accomplished through electronic patient chart review. Patients were stratified based on the type of conduit used to perform the TCPC: polytetrafluoroethylene (PTFE) conduit (Group A) and polyethylene-terephthalate (Dacron) conduit (Group B). RESULTS: The patient population included 105 patients: Group A had 80 patients, and Group B had 25 patients. The two groups were similar in major clinical and procedural variables, including conduit size and Nakata index. Eighteen patients (Group A: one [1.25%]; Group B: 17 [68%]) had conduit occlusion or severe stenosis requiring intervention after a mean 46.9±35months after the operation. The percentage of patients in Group A who were free of conduit obstruction at 3, 5, and 10 years was 100%, 100%, and 96%, respectively, whereas these figures were 68%, 52%, and 35% in Group B (log-rank <0.000). Conduit re-intervention was associated with an increased risk of overall mortality after primary intervention (p<0.004). Dacron tube was found to be an independent risk factor for mid-term stenosis or obstruction (hazard ratio, 62.9; 95% CI, 8.2-482.2; p=0.000). CONCLUSION: Dacron conduit for TCPC surgery was associated with a higher risk of obstruction and need for early re-intervention compared with PTFE conduit. Surgical or percutaneous re-interventions for conduit obstruction increased the risk of late mortality.


Assuntos
Técnica de Fontan , Polietilenotereftalatos , Adolescente , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/prevenção & controle , Criança , Pré-Escolar , Feminino , Seguimentos , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/prevenção & controle , Estudos Retrospectivos
3.
Drug Dev Ind Pharm ; 43(8): 1378-1389, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28420285

RESUMO

OBJECTIVE: This study aimed to design and characterize an inhalable dry powder of ciprofloxacin or levofloxacin combined with the mucolytics acetylcysteine and dornase alfa for the management of pulmonary infections in patients with cystic fibrosis. METHODS: Ball milling, homogenization in isopropyl alcohol and spray drying processes were used to prepare dry powders for inhalation. Physico-chemical characteristics of the dry powders were assessed via thermogravimetric analysis, differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FT-IR), X-ray diffractometry and scanning electron microscopy. The particle size distribution, dissolution rate and permeability across Calu-3 cell monolayers were analyzed. The aerodynamic parameters of dry powders were determined using the Andersen cascade impactor (ACI). RESULTS: After the micronization process, the particle sizes of the raw materials significantly decreased. X-ray and DSC results indicated that although ciprofloxacin showed no changes in its crystal structure, the structure of levofloxacin became amorphous after the micronization process. FT-IR spectra exhibited the characteristic peaks for ciprofloxacin and levofloxacin in all formulations. The dissolution rates of micro-homogenized and spray-dried ciprofloxacin were higher than that of untreated ciprofloxacin. ACI results showed that all formulations had a mass median aerodynamic diameter less than 5 µm; however, levofloxacin microparticles showed higher respirability than ciprofloxacin powders did. The permeability of levofloxacin was higher than those of the ciprofloxacin formulations. CONCLUSION: Together, our study showed that these methods could suitably characterize antibiotic and mucolytic-containing dry powder inhalers.


Assuntos
Ciprofloxacina/administração & dosagem , Ciprofloxacina/uso terapêutico , Fibrose Cística/tratamento farmacológico , Desoxirribonuclease I/química , Expectorantes/química , Levofloxacino/administração & dosagem , Levofloxacino/uso terapêutico , Pós/administração & dosagem , Administração por Inalação , Varredura Diferencial de Calorimetria , Química Farmacêutica , Ciprofloxacina/química , Fibrose Cística/fisiopatologia , Desoxirribonuclease I/administração & dosagem , Inaladores de Pó Seco , Expectorantes/farmacocinética , Humanos , Levofloxacino/química , Microscopia Eletrônica de Varredura , Tamanho da Partícula , Pós/química , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/química , Espectroscopia de Infravermelho com Transformada de Fourier
4.
Pharm Res ; 33(3): 701-15, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26572643

RESUMO

PURPOSE: The aim of this work was to evaluate the effect of two different dry powder inhalers, of the NGI induction port and Alberta throat and of the actual inspiratory profiles of asthmatic patients on in-vitro drug inhalation performances. METHODS: The two devices considered were a reservoir multidose and a capsule-based inhaler. The formulation used to test the inhalers was a combination of formoterol fumarate and beclomethasone dipropionate. A breath simulator was used to mimic inhalatory patterns previously determined in vivo. A multivariate approach was adopted to estimate the significance of the effect of the investigated variables in the explored domain. RESULTS: Breath simulator was a useful tool to mimic in vitro the in vivo inspiratory profiles of asthmatic patients. The type of throat coupled with the impactor did not affect the aerodynamic distribution of the investigated formulation. However, the type of inhaler and inspiratory profiles affected the respirable dose of drugs. CONCLUSIONS: The multivariate statistical approach demonstrated that the multidose inhaler, released efficiently a high fine particle mass independently from the inspiratory profiles adopted. Differently, the single dose capsule inhaler, showed a significant decrease of fine particle mass of both drugs when the device was activated using the minimum inspiratory volume (592 mL).


Assuntos
Antiasmáticos/administração & dosagem , Asma/tratamento farmacológico , Cápsulas/administração & dosagem , Capacidade Inspiratória/efeitos dos fármacos , Pós/administração & dosagem , Respiração/efeitos dos fármacos , Administração por Inalação , Adolescente , Adulto , Idoso , Beclometasona/administração & dosagem , Química Farmacêutica/métodos , Inaladores de Pó Seco/métodos , Feminino , Fumarato de Formoterol/administração & dosagem , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Tamanho da Partícula , Faringe/efeitos dos fármacos , Adulto Jovem
5.
Pharm Res ; 33(12): 3012-3020, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27623625

RESUMO

PURPOSE: In this work, a novel powder dispersion add-on device, the AOS (Axial Oscillating Sphere), was studied in conjunction with commercially available DPI devices to improve the powder dispersion. METHODS: An ordered mixture of formoterol fumarate and lactose was selected. We studied in two laboratories located at different altitudes the dispensing and dispersion of the drug at different flow rates, paying particular attention to a number of metrics of Fine Particle Dose (FPD). RESULTS: Two novel findings emerged from the data collected. First, the aerosol quality, measured as fine particle dose, can be increased by adding the accessory promoting the dispersion and de-aggregation of the formulation. The second finding was that, albeit the emitted dose was independent of altitude, the drug/lactose carrier DPI aerosolizing performance changed with the altitude of testing. In particular, fine particle dose depended on both altitude and device configuration. The RS01 inhaler without the AOS accessory used at higher altitude gave the lowest FPD values. By combining the AOS accessory with the DPI, however, the performance dependence on altitude/atmospheric pressure was essentially removed. CONCLUSIONS: Increasing inhaler performance can be achieved using an add-on accessory that enhances aerosol dispersion and minimizes flow rate dependency.


Assuntos
Inaladores de Pó Seco/instrumentação , Inaladores de Pó Seco/métodos , Administração por Inalação , Aerossóis , Portadores de Fármacos , Composição de Medicamentos , Desenho de Equipamento , Humanos , Lactose/química , Tamanho da Partícula , Pós
7.
Biochim Biophys Acta ; 1830(9): 4374-80, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23295972

RESUMO

BACKGROUND: Organic electrochemical transistors (OECTs), which are becoming more and more promising devices for applications in bioelectronics and nanomedicine, are proposed here as ideally suitable for sensing and real time monitoring of liposome-based structures. This is quite relevant since, currently, the techniques used to investigate liposomal structures, their stability in different environments as well as drug loading and delivery mechanisms, operate basically off-line and/or with pre-prepared sampling. METHODS: OECTs, based on the PEDOT:PSS conductive polymer, have been employed as sensors of liposome-based nanoparticles in electrolyte solutions to assess sensitivity and monitoring capabilities based on ion-to-electron amplified transduction. RESULTS: We demonstrate that OECTs are very efficient, reliable and sensitive devices for detecting liposome-based nanoparticles on a wide dynamic range down to 10(-5)mg/ml (with a lowest detection limit, assessed in real-time monitoring, of 10(-7)mg/ml), thus matching the needs of typical drug loading/drug delivery conditions. They are hence particularly well suited for real-time monitoring of liposomes in solution. Furthermore, OECTs are shown to sense and discriminate successive injection of different liposomes, so that they could be good candidates in quality-control assays or in the pharmaceutical industry. GENERAL SIGNIFICANCE: Drug loading and delivery by liposome-based structures is a fast growing and very promising field that will strongly benefit from real-time, highly sensitive and low cost monitoring of their dynamics in different pharma and biomedical environments, with a particular reference to the pharmaceutical and production processes, where a major issue is monitoring and measuring the formation and concentration of liposomes and the relative drug load. The demonstrated ability to sense and monitor complex bio-structures, such as liposomes, paves the way for very promising developments in biosensing and nanomedicine. This article is part of a Special Issue entitled Organic Bioelectronics-Novel Applications in Biomedicine.


Assuntos
Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Lipossomos/química , Microfluídica/instrumentação , Microfluídica/métodos , Transistores Eletrônicos , Nanomedicina/instrumentação , Nanomedicina/métodos , Nanopartículas/química , Polímeros/química , Poliestirenos/química , Soluções/química , Tiofenos/química
8.
Am J Cardiol ; 226: 50-58, 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38986860

RESUMO

Surgical implantation of a right ventricle to pulmonary artery (RV-PA) conduit is an important component of congenital heart disease (CHD) surgery, but with limited durability, leading to re-intervention. The present single-center, retrospective, cohort study reports the results of surgically implanted RV-PA conduits in a consecutive series of children and adults with CHD. Patients with CHD referred for RV-PA conduit surgical implantation (from October 1997 to January 2022) were included. The primary outcome was conduit failure, defined as a peak gradient above 64 mm Hg, severe regurgitation, or the need for conduit-related interventions. Longitudinal echocardiographic studies were available for mixed-effects linear regression analysis. A total of 252 patients were initially included; 149 patients were eligible for follow-up data collection. After a median follow-up time of 49 months, the primary study end point occurred in 44 (29%) patients. A multivariable Cox regression model identified adult age (>18 years) at implantation and pulmonary homograft implantation as protective factors (hazard ratio 0.11, 95% confidence interval [CI] 0.02 to 0.47 and hazard ratio 0.34, 95% CI 0.16 to 0.74, respectively). Fever within 7 days of surgical conduit implantation was a risk factor for early (within 24 months) failure (odds ratio 4.29, 95% CI 1.41 to 13.01). Long-term use of oral anticoagulants was independently associated with slower progression of peak echocardiographic gradient across the conduits (mixed-effects linear regression p = 0.027). In patients with CHD, the rate of failure of surgically implanted RV-PA conduits is higher in children and after nonhomograft conduit implantation. Early fever after surgery is a strong risk factor for early failure. Long-term anticoagulation seems to exert a protective effect.

9.
Eur Heart J ; 33(11): 1378-85, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22036871

RESUMO

OBJECTIVE: To assess whether exercise training in adult patients with a systemic right ventricle (RV) improves exercise capacity and quality of life and lowers serum N-terminal prohormone brain natriuretic peptide (NT-proBNP) levels. DESIGN: Multi-centre parallel randomized controlled trial. PARTICIPANTS: Patients with a systemic RV due to congenitally or surgically corrected transposition of the great arteries. METHODS: Fifty-four adult patients with a systemic RV, were randomized using unmarked opaque envelopes to an intervention group (n = 28) with three training sessions per week for 10 consecutive weeks, and a control group (n = 26). Randomization was stratified by participating centre. At baseline, and follow-up, we determined maximal exercise capacity (V'O(2peak)), serum NT-proBNP levels, and quality of life by means of the SF-36, and the TAAQOL Congenital Heart Disease questionnaires. The final analysis was performed by linear regression, taking into account the stratified randomization. RESULTS: Forty-six patients were analysed (male 50%, age 32 ± 11 years, intervention group n = 24, control group n = 22). Analysis at 10 weeks showed a significant difference in V'O(2peak) (3.4 mL/kg/min, 95% CI: 0.2 to 6.7; P = 0.04) and resting systolic blood pressure (-7.6 mmHg, 95% CI: -14.0 to -1.3; P = 0.03) in favour of the exercise group. No significant changes were found in serum NT-proBNP levels or quality of life in the intervention group or in the control group nor between groups. None of the patients in the intervention group had to discontinue the training programme due to adverse events. CONCLUSION: In adult patients with a systemic RV exercise training improve exercise capacity. We recommend to revise restrictive guidelines, and to encourage patients to become physically active. ( TRIAL REGISTRATION: The study was registered at http://trialregister.nl. Identifier: NTR1909.).


Assuntos
Terapia por Exercício , Tolerância ao Exercício/fisiologia , Transposição dos Grandes Vasos/fisiopatologia , Disfunção Ventricular Direita/terapia , Adulto , Transposição das Grandes Artérias Corrigida Congenitamente , Feminino , Humanos , Masculino , Peptídeo Natriurético Encefálico/metabolismo , Fragmentos de Peptídeos/metabolismo , Estudos Prospectivos , Qualidade de Vida , Transposição dos Grandes Vasos/sangue , Resultado do Tratamento , Disfunção Ventricular Direita/sangue , Disfunção Ventricular Direita/fisiopatologia , Adulto Jovem
10.
AAPS PharmSciTech ; 14(3): 911-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23703233

RESUMO

Artemisinin, a poorly water-soluble antimalarial drug, presents a low and erratic bioavailability upon oral administration. The aim of this work was to study an agglomerated powder dosage form for oral administration of artemisinin based on the artemisinin/ß-cyclodextrin primary microparticles. These primary microparticles were prepared by spray-drying a water-methanol solution of artemisinin/ß-cyclodextrin. ß-Cyclodextrin in spray-dried microparticles increased artemisinin water apparent solubility approximately sixfold. The thermal analysis evidenced a reduction in the enthalpy value associated with drug melting, due to the decrease in drug crystallinity. The latter was also evidenced by powder X-ray diffraction analysis, while (13)C-NMR analysis indicated the partial complexation with ß-cyclodextrin. Agglomerates obtained by sieve vibration of spray-dried artemisinin/ß-cyclodextrin primary microparticles exhibited free flowing and close packing properties compared with the non-flowing microparticulate powder. The in vitro dissolution rate determination of artemisinin from the agglomerates showed that in 10 min about 70% of drug was released from the agglomerates, whereas less than 10% of artemisinin was dissolved from raw material powder. Oral administration of agglomerates in rats yielded higher artemisinin plasma levels compared to those of pure drug. In the case of the agglomerated powder, a 3.2-fold increase in drug fraction absorbed was obtained.


Assuntos
Artemisininas/administração & dosagem , beta-Ciclodextrinas/administração & dosagem , Administração Oral , Artemisininas/farmacocinética , Disponibilidade Biológica , Varredura Diferencial de Calorimetria , Formas de Dosagem , Espectroscopia de Ressonância Magnética , Microscopia Eletrônica de Varredura , Solubilidade , Espectroscopia de Infravermelho com Transformada de Fourier , Termodinâmica , beta-Ciclodextrinas/farmacocinética
11.
J Matern Fetal Neonatal Med ; 36(1): 2197099, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37031967

RESUMO

We report the case of a massive fetal cardiac rhabdomyoma recently occurred at our clinic. A woman at 23 weeks of gestational age was referred to our center for a fetal cardiac echogenic mass of 26 mm detected at the second-trimester screening ultrasound. During pregnancy, though, the mass progressively increased its dimensions until reaching 48 mm in diameter at 37 weeks of gestation. Fetal echoencephalography and brain magnetic resonance did not show any further fetal anomalies, but molecular genetic testing at amniocentesis revealed a heterozygotic missense variant of gene TSC2 associated with Tuberous Sclerosis. The mass was therefore most likely preferable to a single large rhabdomyoma of gradually increasing dimensions. The baby was delivered at term with a cesarean section. Because of the rhabdomyoma remarkable size and newborn ECG electrical alterations, postnatal therapies with Flecainide and Everolimus were started. Everolimus treatment led to a significant and progressive reduction in the cardiac mass volume. This case, therefore, shows the efficacy of what seems to be a promising treatment in pediatric patients with large rhabdomyomas.Learning points:Rhabdomyomas may present with different features: most often they appear as multiple masses along the interventricular sept, but they may also appear as a single large thoracic mass.When a rhabdomyoma is suspected, genetic counseling is recommended.Both before and after birth, a multidisciplinary approach is useful to choose the appropriate therapy for the newborn.mTOR inhibitors therapies look like promising therapeutic approaches to stimulate the involution of rhabdomyomas.


Assuntos
Neoplasias Cardíacas , Rabdomioma , Esclerose Tuberosa , Lactente , Recém-Nascido , Humanos , Gravidez , Criança , Feminino , Rabdomioma/diagnóstico por imagem , Rabdomioma/genética , Rabdomioma/complicações , Everolimo , Cesárea , Ultrassonografia , Esclerose Tuberosa/complicações , Esclerose Tuberosa/diagnóstico por imagem , Esclerose Tuberosa/genética , Neoplasias Cardíacas/diagnóstico por imagem , Neoplasias Cardíacas/terapia , Neoplasias Cardíacas/complicações
12.
Nutrients ; 15(3)2023 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-36771190

RESUMO

Children with congenital heart disease (CHD) are at increased risk for undernutrition. The aim of our study was to describe the growth parameters of Italian children with CHD compared to healthy children. We performed a cross-sectional study collecting the anthropometric data of pediatric patients with CHD and healthy controls. WHO and Italian z-scores for weight for age (WZ), length/height for age (HZ), weight for height (WHZ) and body mass index (BMIZ) were collected. A total of 657 patients (566 with CHD and 91 healthy controls) were enrolled: 255 had mild CHD, 223 had moderate CHD and 88 had severe CHD. Compared to CHD patients, healthy children were younger (age: 7.5 ± 5.4 vs. 5.6 ± 4.3 years, p = 0.0009), taller/longer (HZ: 0.14 ± 1.41 vs. 0.62 ± 1.20, p < 0.002) and heavier (WZ: -0,07 ± 1.32 vs. 0.31 ± 1.13, p = 0.009) with no significant differences in BMIZ (-0,14 ± 1.24 vs. -0.07 ± 1.13, p = 0.64) and WHZ (0.05 ± 1.47 vs. 0.43 ± 1.07, p = 0.1187). Moderate and severe CHD patients presented lower z-scores at any age, with a more remarkable difference in children younger than 2 years (WZ) and older than 5 years (HZ, WZ and BMIZ). Stunting and underweight were significantly more present in children affected by CHD (p < 0.01). In conclusion, CHD negatively affects the growth of children based on the severity of the disease, even in a high-income country, resulting in a significant percentage of undernutrition in this population.


Assuntos
Cardiopatias Congênitas , Desnutrição , Humanos , Criança , Lactente , Pré-Escolar , Estudos Retrospectivos , Estudos Transversais , Cardiopatias Congênitas/complicações , Desnutrição/complicações , Desnutrição/epidemiologia , Transtornos do Crescimento/etiologia , Transtornos do Crescimento/complicações
13.
J Cardiovasc Dev Dis ; 10(5)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37233186

RESUMO

BACKGROUND: A progressively increasing prevalence of congenital heart disease (CHD) in adulthood has been noticed in recent decades; CHD cases with a systemic right ventricle have a poorer outcome. METHODS: Seventy-three patients with SRV evaluated in an outpatient clinic between 2014 and 2020 were enrolled in this study. Thirty-four patients had a transposition of the great arteries treated with an atrial switch operation; 39 patients had a congenitally corrected transposition of the great arteries (ccTGA). RESULTS: Mean age at the first evaluation was 29.6 ± 14.2 years; 48% of the patients were female. The NYHA class at the visit was III or IV in 14% of the cases. Thirteen patients had at least one previous pregnancy. In 25% of the cases, complications occurred during pregnancy. Survival free from adverse events was 98.6% at one year and 90% at 6-year follow-up without any difference between the two groups. Two patients died and one received heart transplantation during follow-up. The most common adverse event during follow-up was the presence of arrhythmia requiring hospitalization (27.1%), followed by heart failure (12.3%). The presence of LGE together with lower exercise capacity, higher NYHA class and more dilated and/or hypokinetic RV predicted a poorer outcome. Quality of life was similar to the QoL of the Italian population. CONCLUSIONS: Long-term follow-up of patients with a systemic right ventricle is characterized by a high incidence of clinical events, prevalently arrhythmias and heart failure, which cause most of the unscheduled hospitalizations.

14.
J Matern Fetal Neonatal Med ; 36(1): 2201654, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37073133

RESUMO

INTRODUCTION: The evaluation of upcoming Aortic Coarctation (CoA) in new-borns with prenatal suspicion entails a close echocardiographic monitor until Arterial Duct (AD) closure, in a department with pediatric cardiological and surgical expertise. The significant number of false-positive prenatal diagnoses causes parental stress and healthcare costs. AIM: The aim of this study was to elaborate an echocardiographic prediction model to be employed at birth when PDA is still present, in patients suspected of CoA during fetal life in order to foretell CoA requiring neonatal surgical intervention. METHODS: This retrospective monocentric study included consecutive full-term and late preterm neonates with prenatal suspicion of CoA born from 01 January 2007 to 31 December 2020. Patients were divided into two groups according to the need for aortic surgery (CoA - NoCoA). All patients underwent a comprehensive transthoracic echocardiographic exam in presence of PDA. Multivariable logistic regression was used to create a coarctation probability model (CoMOD) including isthmal (D4), transverse arch (D3) diameters, the distance between a left common carotid artery (LCA) and left subclavian artery (LSA), presence/absence of ventricular septal defect (VSD) and bicuspid aortic valve (BAV). RESULTS: We enrolled 87 neonates (49 male, 56%). 44 patients developed CoA in need of surgical repair. Our index CoMOD showed an AUC = 0.9382, high sensitivity (91%) and specificity (86%) in the prediction of CoA in neonates with prenatal suspicion. We classified neonates with CoMOD > 0 to be at high risk for surgical correction of CoA, with good PPV (86.9%) and NPV (90.9%). CONCLUSIONS: CoMOD > 0 is highly suggestive of the need for CoA corrective surgery in newborns with prenatal suspicion.


Assuntos
Coartação Aórtica , Permeabilidade do Canal Arterial , Criança , Gravidez , Feminino , Humanos , Masculino , Recém-Nascido , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/cirurgia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Estudos Retrospectivos , Ecocardiografia , Aorta Torácica/diagnóstico por imagem
15.
J Cardiovasc Echogr ; 33(1): 1-9, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37426716

RESUMO

Background: The Italian Society of Echocardiography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand better how different echocardiographic modalities are used and accessed in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved via an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories: 112 centers (49%) in the northern, 43 centers (19%) in the central, and 73 (32%) in the southern regions. During the month of observation, we collected 101,050 transthoracic echocardiography (TTE) examinations performed in all centers. As concern other modalities there were performed 5497 transesophageal echocardiography (TEE) examinations in 161/228 centers (71%); 4057 stress echocardiography (SE) examinations in 179/228 centers (79%); and examinations with ultrasound contrast agents (UCAs) in 151/228 centers (66%). We did not find significant regional variations between the different modalities. The usage of picture archiving and communication system (PACS) was significantly higher in the northern (84%) versus central (49%) and southern (45%) centers (P < 0.001). Lung ultrasound (LUS) was performed in 154 centers (66%), without difference between cardiology and noncardiology centers. The evaluation of left ventricular (LV) ejection fraction was evaluated mainly using the qualitative method in 223 centers (94%), occasionally with the Simpson method in 193 centers (85%), and with selective use of the three-dimensional (3D) method in only 23 centers (10%). 3D TTE was present in 137 centers (70%), and 3D TEE in all centers where TEE was done (71%). The assessment of LV diastolic function was done routinely in 80% of the centers. Right ventricular function was evaluated using tricuspid annular plane systolic excursion in all centers, using tricuspid valve annular systolic velocity by tissue Doppler imaging in 53% of the centers, and using fractional area change in 33% of the centers. When we divided into cardiology (179, 78%) and noncardiology (49, 22%) centers, we found significant differences in the SE (93% vs. 26%, P < 0.001), TEE (85% vs. 18%), UCA (67% vs. 43%, P < 0001), and STE (87% vs. 20%, P < 0.001). The incidence of LUS evaluation was similar between the cardiology and noncardiology centers (69% vs. 61%, P = NS). Conclusions: This nationwide survey demonstrated that digital infrastructures and advanced echocardiography modalities, such as 3D and STE, are widely available in Italy with a notable diffuse uptake of LUS in the core TTE examination, a suboptimal diffusion of PACS recording, and conservative use of UCA, 3D, and strain. There are significant differences between northern and central-southern regions and echocardiographic laboratories that pertain to the cardiac unit. This inhomogeneous distribution of technology represents one of the main issues that must be solved to standardize the practice of echocardiography.

16.
J Cardiovasc Echogr ; 33(3): 125-132, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38161775

RESUMO

Background: The Italian Society of Echography and Cardiovascular Imaging (SIECVI) conducted a national survey to understand the volumes of activity, modalities and stressors used during stress echocardiography (SE) in Italy. Methods: We analyzed echocardiography laboratory activities over a month (November 2022). Data were retrieved through an electronic survey based on a structured questionnaire, uploaded on the SIECVI website. Results: Data were obtained from 228 echocardiographic laboratories, and SE examinations were performed in 179 centers (80.6%): 87 centers (47.5%) were in the northern regions of Italy, 33 centers (18.4%) were in the central regions, and 61 (34.1%) in the southern regions. We annotated a total of 4057 SE. We divided the SE centers into three groups, according to the numbers of SE performed: <10 SE (low-volume activity, 40 centers), between 10 and 39 SE (moderate volume activity, 102 centers) and ≥40 SE (high volume activity, 37 centers). Dipyridamole was used in 139 centers (77.6%); exercise in 120 centers (67.0%); dobutamine in 153 centers (85.4%); pacing in 37 centers (21.1%); and adenosine in 7 centers (4.0%). We found a significant difference between the stressors used and volume of activity of the centers, with a progressive increase in the prevalence of number of stressors from low to high volume activity (P = 0.033). The traditional evaluation of regional wall motion of the left ventricle was performed in all centers, with combined assessment of coronary flow velocity reserve (CFVR) in 90 centers (50.3%): there was a significant difference in the centers with different volume of SE activity: the incidence of analysis of CFVR was significantly higher in high volume centers compared to low - moderate - volume (32.5%, 41.0% and 73.0%, respectively, P < 0.001). The lung ultrasound (LUS) was assessed in 67 centers (37.4%). Furthermore for LUS, we found a significant difference in the centers with different volume of SE activity: significantly higher in high volume centers compared to low - moderate - volume (25.0%, 35.3% and 56.8%, respectively, P < 0.001). Conclusions: This nationwide survey demonstrated that SE was significantly widespread and practiced throughout Italy. In addition to the traditional indication to coronary artery disease based on regional wall motion analysis, other indications are emerging with an increase in the use of LUS and CFVR, especially in high-volume centers.

17.
Life (Basel) ; 12(10)2022 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-36295043

RESUMO

Although hypertrophic cardiomyopathy (HCM) is classically considered a disease of the left ventricle, right ventricular (RV) involvement has also been reported, though still not extensively characterized. We present a case of biventricular HCM with significant RV involvement in the absence of a left intraventricular gradient: RV outflow tract gradient due to hypertrophy and near obliteration of the RV cavity. Significant RV hypertrophy may cause reduced RV diastolic filling and/or RV outflow obstruction, with potentially increased incidence of symptoms of heart failure, arrhythmias, and pulmonary thromboembolism. The optimal treatment for these patients is unclear. Our patient underwent complete treatment and elimination of right ventricular obstruction, resulting in improved symptoms and a significant reduction in postoperative gradients. Direct relief of outflow tract obstruction can be achieved with low morbidity and good intermediate- to long-term results. Conventional surgery may provide significant symptomatic improvement and should thus be considered in the setting of HCM with outflow obstruction.

18.
J Matern Fetal Neonatal Med ; 35(25): 6090-6096, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33823732

RESUMO

BACKGROUND: Speckle tracking technology has been applied to assess ventricular deformation throughout the cardiac cycle. An electronic four dimensional probe that allows rapid acquisition of electronic spatio-temporal image correlation volumes (eSTIC) has been recently introduced. OBJECTIVES: The aim of our study was to investigate whether e-STIC acquisition improves deformation analyses reproducibility. STUDY DESIGN: We recruited fetuses between 20 and 40 weeks of gestation. We obtained a 2D video clip and an e-STIC volume of a four-chamber view. We focused on left ventricular global strain (LV-GS) and left ventricular ejection fraction (LV-FE). Intraobserver, interobserver and intermethod agreement were assessed by means of intraclass correlation coefficient (ICC) and illustrated by Bland-Altman plots. Systematic differences between measurements were assessed using a paired t-test. RESULTS: The mean difference between LV-GS values obtained with e-STIC and 2D analysis was -0.10 (95% CI -2.28, 2.08). No systematic differences were found between the two techniques for LV-GS values (p-value = .927). The mean difference between LV-FE values obtained with e-STIC and 2D analysis was 7.55 (95% CI 4.16, 10.95; p-value <.001). The inter-rater reliability of LV-GS was moderate-to-substantial for both e-STIC and 2D. The inter-rater reliability of LV-FE obtained via e-STIC was superior to that obtained via 2D analysis. The intra-rater reliability of LV-GS obtained with e-STIC was superior to that obtained with 2D analysis (ICC 0.857; 95% IC 0.761-0.917). The intra-rater reliability of LV-FE obtained via e-STIC was superior to that obtained via 2D analysis (ICC 0.647; IC 0.51-0.783). CONCLUSIONS: e-STIC seems to be a better technique than 2D analysis for intra-rater reliability of LV-GS. 4D acquisition might improve intrinsic limitations of speckle tracking echocardiography.


Assuntos
Ecocardiografia Tridimensional , Função Ventricular Esquerda , Feminino , Humanos , Volume Sistólico , Reprodutibilidade dos Testes , Ecocardiografia/métodos , Feto , Eletrônica , Ecocardiografia Tridimensional/métodos
19.
J Matern Fetal Neonatal Med ; 35(22): 4299-4305, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33203263

RESUMO

INTRODUCTION: Coarctation of the aorta (CoA) is common and can lead to neonatal emergency. Despite its burden, antenatal detection of this condition remains inaccurate. OBJECTIVE: To evaluate the diagnostic performance of fetal echocardiography and to design a scoring system for risk stratification of CoA in suspected cases. DESIGN: A retrospective cohort study. SETTING: S. Orsola Hospital, Bologna, Italy. POPULATION: About 140 fetuses referred for suspected CoA to our tertiary center in a 9-year period. METHODS: The following parameters were systematically obtained at fetal echocardiography: ventricular disproportion, great vessels asymmetry, transverse aortic arch hypoplasia, flow turbulence, and Z-scores of the ascending aorta and of the aortic isthmus. Associated anomalies were recorded, if present. When CoA was not confirmed at birth, neonates were followed up for 12 months to identify also a tardive onset of this condition. MAIN OUTCOME MEASURES: The primary outcome was the presence of COA after birth. RESULTS: 108 fetuses were eligible for the purpose of the study. CoA was confirmed postnatally in 55 neonates (50.9%). Arch hypoplasia yielded the highest correlation with CoA. The affected neonates presented also significantly lower Z scores of the ascending aorta and of the aortic isthmus. Earlier gestational age at referral was positively correlated with neonatal CoA. An odds ratio-based multiparametric model was designed to build a scoring system (AUC 0.89). CONCLUSION: In our cohort, no single ultrasound parameter was sufficiently accurate to predict postnatal CoA. The scoring system permitted a better identification of the affected fetuses.


Assuntos
Coartação Aórtica , Aorta , Coartação Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Recém-Nascido , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal
20.
G Ital Cardiol (Rome) ; 22(9): 756-766, 2021 Sep.
Artigo em Italiano | MEDLINE | ID: mdl-34463685

RESUMO

Regular physical activity is essential for physical health and mental wellbeing in children and teenagers. However, patients with congenital heart disease are often restricted from being physically active due to parental overprotection and lack of physical activity promotion or exercise prescription from their physicians. A comprehensive medical evaluation is crucial for the development of personalized exercise programs for these patients. The aim of this review is to provide physicians with a practical guide on how to promote physical activity and prescribe exercise for patients with congenital heart disease with or without surgical correction.


Assuntos
Cardiologia , Cardiopatias Congênitas , Adolescente , Criança , Exercício Físico , Humanos , Itália , Prescrições
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA