Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 96(2): E142-E148, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31696618

RESUMO

OBJECTIVES: To assess long-term safety and efficacy of the Xposition S self-apposing stent in the treatment of unprotected left main coronary artery (ULMCA) disease. BACKGROUND: Percutaneous intervention with stents has emerged as a valid alternative to surgical revascularization to treat ULMCA disease. Conventional balloon-expandable stents face technical challenges, particularly in large left main diameter requiring extensive optimization and side branch access in distal bifurcation. Xposition S allows for optimal apposition, bridging diameter differences, and allows expansion to vessel diameters up to 6.0 mm. METHODS: Between June 2016 and July 2017, 205 patients were enrolled in this international, prospective, multicenter registry. Patients with SYNTAX score ≥ 33 or recent STEMI were excluded. IVUS during procedure was performed in a prespecified subgroup of 50 patients. The primary clinical endpoint was 12 months Target lesion failure (TLF) and the primary efficacy endpoint was angiographic success. RESULTS: Distal left main bifurcation was involved in 92.7%, treated with provisional approach in most cases (79.4%). TLF rate at 12 months was 8.3%, which was defined as a composite of cardiac death (2.0%), target-vessel MI (2.9%), and TLR (5.4%). Most revascularizations occurred at SB ostium. IVUS analysis demonstrated optimal stent apposition with only one reported malapposition and promising poststenting minimal stent area measures. CONCLUSIONS: The TRUNC study confirms that Xposition S self-apposing stent is a valid and feasible option for the treatment of ULMCA disease. Such results were reached without the systematic need of stent optimisation techniques, focusing mainly on lesion treatment.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Stents Metálicos Autoexpansíveis , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 94(7): 966-971, 2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-30903739

RESUMO

OBJECTIVES: The aim is to assess the experience in the Netherlands using the Xposition S self-apposing stent in complex coronary lesions in clinical practice. BACKGROUND: Treatment of complex coronary lesions could be accompanied with stent sizing difficulties and complications, particularly due to vessel overdilation or stent underexpansion. The self-apposing feature of the Xposition S stent (STENTYS, Paris, France) supports good strut apposition in complex anatomies and allows for an increase in diameter after implantation. METHODS: In this real-world registry, data from patients treated with Xposition S in four Dutch clinical sites were prospectively collected and analyzed. Any patient suitable for implantation with Xposition S according to current recommendations was enrolled. Primary endpoint was major adverse cardiac events (MACE) at 1 year. RESULTS: Between 2015 and 2018, data from 251 patients were collected. Clinical presentation was an acute coronary syndrome in majority of the patients (76.9%). Main angiographic indications were lesions in aneurysmatic or ectatic vessels (32.3%), thrombus containing lesions (13.1%), and bifurcation/left main stenosis (10.4%). Most of the target lesions (TLs) were classified as AHA/ACC Type C (53.6%). Despite lesion complexity, device was successfully implanted at TL in 96.8%. MACE rate, reported on patients having completed 1-year follow-up (n = 203), was 6.6%, with low rate of definite/probable stent thrombosis (1.0%). CONCLUSIONS: In clinical practice of several Dutch sites, STENTYS Xposition S showed good procedural results and low 1-year clinical events rate, despite complex coronary anatomy.


Assuntos
Síndrome Coronariana Aguda/terapia , Angioplastia Coronária com Balão/instrumentação , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Síndrome Coronariana Aguda/diagnóstico por imagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Trombose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento