Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 31(7): 1649-1657, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32400073

RESUMO

BACKGROUND: The diagnostic accuracy of incremental atrial pacing (IP) to determine complete cavo-tricuspid isthmus (CTI) block during typical atrial flutter (AFL) ablation is limited by both an extensive/nonlinear ablation and/or the presence of intra-atrial conduction delay elsewhere in the right atrium. We examined the diagnostic performance of an IP variant based on the assessment of the atrial potentials adjacent to the ablation line which aims at overcoming both limitations. METHODS: From a prospective population of 108 consecutive patients, 15 were excluded due to observation of inconclusive CTI ablation potentials precluding for a straight comparison between the IP maneuver and its variant. In the remaining 93, IP was performed from the low lateral right atrium and the coronary sinus ostium, with the ablation catheter positioned both at the CTI line and adjacent (<5 mm) to its septal and lateral aspect. The IP variant consisted of measuring the interval between the two atrial electrograms situated on the same side of the ablation line, opposite to the pacing site, a ≤10 ms increase indicating complete CTI block. RESULTS: The IP maneuver and its variant were consistent with complete CTI block in 82/93 (88%) and 87/93 (93%) patients, respectively. Four patients had AFL recurrence during follow-up: 2/4 and 4/4 had been adequately classified as incomplete block by the IP maneuver and its variant, respectively. Twenty-three patients (24%) had significant intra-atrial conduction delay elsewhere in the right atrium. The IP maneuver and its variant were suggestive of an incomplete CTI block in 11/23 and 4/23 in this setting (P = .028), with the later best predicting subsequent AFL relapses (2/12 vs 2/4, P = .01). CONCLUSIONS: The IP variant, which was designed to overcome the limitations of the conventional IP maneuver, accurately distinguishes complete from incomplete CTI block and helps to predict AFL recurrences after ablation.


Assuntos
Flutter Atrial , Ablação por Cateter , Flutter Atrial/diagnóstico , Flutter Atrial/cirurgia , Técnicas Eletrofisiológicas Cardíacas , Humanos , Estudos Prospectivos , Resultado do Tratamento
2.
J Clin Med ; 11(8)2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35456193

RESUMO

Background: Pulmonary veins isolation (PVI) is a standard treatment for recurrent atrial fibrillation (AF). Uninterrupted anticoagulation for a minimum of 3 weeks before ablation and exclusion of left atrial (LA) thrombus with transesophageal echography (TEE) immediately before or during the procedure minimize peri-procedural risk. We aimed to demonstrate the utility of cardiac tomography (CT) and cardiac magnetic resonance (CMR) to rule out LA thrombus prior to PVI. Methods: Patients undergoing PVI for recurrent AF were retrospectively evaluated. Only patients that started anticoagulation at least 3 weeks prior to the CT/CMR and subsequently uninterrupted until the ablation procedure were selected. An intracardiac echo (ICE) catheter was used in all patients to evaluate LA thrombus. The results of CT/CMR were compared to ICE imaging. Results: We included 272 consecutive patients averaging 54.5 years (71% male; 30% persistent AF). Average CHA2DS2VASC score was 0.9 ± 0.83 and mean LA diameter was 42 ± 5.7 mm, 111 (41%) patients were on Acenocumarol and 161 (59%) were on direct oral anticoagulants. Anticoagulation was started 227 ± 392 days before the CT/CMR, and 291 ± 416 days before the ablation procedure. CT/CMR diagnosed intracardiac thrombus in two cases, both in the LA appendage. A new CT/CMR revealed resolution of thrombus after six additional months of uninterrupted anticoagulation. No macroscopic thrombus was observed in any patients with ICE (negative predictive value of 100%; p < 0.01). Conclusions: CT and MRI are excellent surrogates to TEE and ICE to rule out intracardiac thrombus in patients adequately anticoagulated prior AF ablation. This is true even for delayed procedures as long as anticoagulation is uninterrupted.

3.
J Cardiol ; 79(3): 417-422, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34774385

RESUMO

PURPOSE: Patients undergoing cavotricuspid isthmus (CTI) ablation for typical flutter (AFL) have a high incidence of new onset atrial fibrillation (AF). We aimed to analyze the influence of PACE score to predict new onset AF in this subset of patients to stratify thromboembolic risk. METHODS: Between 2017 and 2019, patients undergoing CTI ablation for AFL and without history of AF were prospectively included. All patients were monitored continuously by implantable loop recorder and followed by remote monitoring. RESULTS: Overall 48 patients were included. New onset AF rate at 12 months was 56.3%. We observed two very strong independent predictors for new onset AF: a PACE score ≥ 30 (HR:6.9; 95% CI:1.71-27.91; p = 0.007) and an HV interval ≥ 55 (HR:11.86; 95% CI:2.57-54.8; p = 0.002). CONCLUSIONS: The incidence of newly diagnosed AF is high in patients with AFL after CTI ablation, and can occur early. A high PACE score and/or long HV interval predict even higher risk, and may be useful in the decision for empiric long-term anticoagulation.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Flutter Atrial/epidemiologia , Flutter Atrial/etiologia , Ablação por Cateter/efeitos adversos , Humanos , Incidência , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA