Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(14)2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-39065912

RESUMO

OBJECTIVE: The aim of this analysis was to assess glycemic control before and during the coronavirus disease (COVID-19) pandemic. METHODS: Data from 64 (main analysis) and 80 (sensitivity analysis) people with type 1 diabetes (T1D) using intermittently scanned continuous glucose monitoring (isCGM) were investigated retrospectively. The baseline characteristics were collected from electronic medical records. The data were examined over three periods of three months each: from 16th of March 2019 until 16th of June 2019 (pre-pandemic), from 1st of December 2019 until 29th of February 2020 (pre-lockdown) and from 16th of March 2020 until 16th of June 2020 (lockdown 2020), representing the very beginning of the COVID-19 pandemic and the first Austrian-wide lockdown. RESULTS: For the main analysis, 64 individuals with T1D (22 female, 42 male), who had a mean glycated hemoglobin (HbA1c) of 58.5 mmol/mol (51.0 to 69.3 mmol/mol) and a mean diabetes duration 13.5 years (5.5 to 22.0 years) were included in the analysis. The time in range (TIR[70-180mg/dL]) was the highest percentage of measures within all three studied phases, but the lockdown 2020 phase delivered the best data in all these cases. Concerning the time below range (TBR[<70mg/dL]) and the time above range (TAR[>180mg/dL]), the lockdown 2020 phase also had the best values. Regarding the sensitivity analysis, 80 individuals with T1D (26 female, 54 male), who had a mean HbA1c of 57.5 mmol/mol (51.0 to 69.3 mmol/mol) and a mean diabetes duration of 12.5 years (5.5 to 20.7 years), were included. The TIR[70-180mg/dL] was also the highest percentage of measures within all three studied phases, with the lockdown 2020 phase also delivering the best data in all these cases. The TBR[<70mg/dL] and the TAR[>180mg/dL] underscored the data in the main analysis. CONCLUSION: Superior glycemic control, based on all parameters analyzed, was achieved during the first Austrian-wide lockdown compared to prior periods, which might be a result of reduced daily exertion or more time spent focusing on glycemic management.


Assuntos
Automonitorização da Glicemia , Glicemia , COVID-19 , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Controle Glicêmico , Humanos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/epidemiologia , COVID-19/epidemiologia , COVID-19/sangue , Masculino , Áustria/epidemiologia , Feminino , Automonitorização da Glicemia/métodos , Adulto , Glicemia/análise , Controle Glicêmico/métodos , Hemoglobinas Glicadas/análise , Estudos Retrospectivos , Pessoa de Meia-Idade , Pandemias , SARS-CoV-2/isolamento & purificação , Adulto Jovem , Adolescente
2.
Artigo em Inglês | MEDLINE | ID: mdl-38512385

RESUMO

Introduction: This study examined associations between hypoglycemia awareness status and hypoglycemia symptoms reported in real-time using the novel Hypoglycaemia-MEasurement, ThResholds and ImpaCtS (Hypo-METRICS) smartphone application (app) among adults with insulin-treated type 1 (T1D) or type 2 diabetes (T2D). Methods: Adults who experienced at least one hypoglycemic episode in the previous 3 months were recruited to the Hypo-METRICS study. They prospectively reported hypoglycemia episodes using the app for 10 weeks. Any of eight hypoglycemia symptoms were considered present if intensity was rated between "A little bit" to "Very much" and absent if rated "Not at all." Associations between hypoglycemia awareness (as defined by Gold score) and hypoglycemia symptoms were modeled using mixed-effects binary logistic regression, adjusting for glucose monitoring method and diabetes duration. Results: Of 531 participants (48% T1D, 52% T2D), 45% were women, 91% white, and 59% used Flash or continuous glucose monitoring. Impaired awareness of hypoglycemia (IAH) was associated with lower odds of reporting autonomic symptoms than normal awareness of hypoglycemia (NAH) (T1D odds ratio [OR] 0.43 [95% confidence interval {CI} 0.25-0.73], P = 0.002); T2D OR 0.51 [95% CI 0.26-0.99], P = 0.048), with no differences in neuroglycopenic symptoms. In T1D, relative to NAH, IAH was associated with higher odds of reporting autonomic symptoms at a glucose concentration <54 than >70 mg/dL (OR 2.18 [95% CI 1.21-3.94], P = 0.010). Conclusion: The Hypo-METRICS app is sensitive to differences in hypoglycemia symptoms according to hypoglycemia awareness in both diabetes types. Given its high ecological validity and low recall bias, the app may be a useful tool in research and clinical settings. The clinical trial registration number is NCT04304963.

3.
Diabetes Technol Ther ; 26(7): 433-441, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38386436

RESUMO

Introduction: Nocturnal hypoglycemia is generally calculated between 00:00 and 06:00. However, those hours may not accurately reflect sleeping patterns and it is unknown whether this leads to bias. We therefore compared hypoglycemia rates while asleep with those of clock-based nocturnal hypoglycemia in adults with type 1 diabetes (T1D) or insulin-treated type 2 diabetes (T2D). Methods: Participants from the Hypo-METRICS study wore a blinded continuous glucose monitor and a Fitbit Charge 4 activity monitor for 10 weeks. They recorded details of episodes of hypoglycemia using a smartphone app. Sensor-detected hypoglycemia (SDH) and person-reported hypoglycemia (PRH) were categorized as nocturnal (00:00-06:00 h) versus diurnal and while asleep versus awake defined by Fitbit sleeping intervals. Paired-sample Wilcoxon tests were used to examine the differences in hypoglycemia rates. Results: A total of 574 participants [47% T1D, 45% women, 89% white, median (interquartile range) age 56 (45-66) years, and hemoglobin A1c 7.3% (6.8-8.0)] were included. Median sleep duration was 6.1 h (5.2-6.8), bedtime and waking time ∼23:30 and 07:30, respectively. There were higher median weekly rates of SDH and PRH while asleep than clock-based nocturnal SDH and PRH among people with T1D, especially for SDH <70 mg/dL (1.7 vs. 1.4, P < 0.001). Higher weekly rates of SDH while asleep than nocturnal SDH were found among people with T2D, especially for SDH <70 mg/dL (0.8 vs. 0.7, P < 0.001). Conclusion: Using 00:00 to 06:00 as a proxy for sleeping hours may underestimate hypoglycemia while asleep. Future hypoglycemia research should consider the use of sleep trackers to record sleep and reflect hypoglycemia while asleep more accurately. The trial registration number is NCT04304963.


Assuntos
Automonitorização da Glicemia , Glicemia , Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglicemia , Sono , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glicemia/análise , Ritmo Circadiano/fisiologia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/sangue , Hipoglicemia/sangue , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/uso terapêutico , Sono/fisiologia
4.
PLoS One ; 18(3): e0283148, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36930585

RESUMO

INTRODUCTION: The aim of this study was to determine the acceptability and psychometric properties of the Hypo-METRICS (Hypoglycemia MEasurement, ThResholds and ImpaCtS) application (app): a novel tool designed to assess the direct impact of symptomatic and asymptomatic hypoglycemia on daily functioning in people with insulin-treated diabetes. MATERIALS AND METHODS: 100 adults with type 1 diabetes mellitus (T1DM, n = 64) or insulin-treated type 2 diabetes mellitus (T2DM, n = 36) completed three daily 'check-ins' (morning, afternoon and evening) via the Hypo-METRICs app across 10 weeks, to respond to 29 unique questions about their subjective daily functioning. Questions addressed sleep quality, energy level, mood, affect, cognitive functioning, fear of hypoglycemia and hyperglycemia, social functioning, and work/productivity. Completion rates, structural validity, internal consistency, and test-retest reliability were explored. App responses were correlated with validated person-reported outcome measures to investigate convergent (rs>±0.3) and divergent (rs<±0.3) validity. RESULTS: Participants' mean±SD age was 54±16 years, diabetes duration was 23±13 years, and most recent HbA1c was 56.6±9.8 mmol/mol. Participants submitted mean±SD 191±16 out of 210 possible 'check-ins' (91%). Structural validity was confirmed with multi-level confirmatory factor analysis showing good model fit on the adjusted model (Comparative Fit Index >0.95, Root-Mean-Square Error of Approximation <0.06, Standardized Root-Mean-square Residual<0.08). Scales had satisfactory internal consistency (all ω≥0.5), and high test-retest reliability (rs≥0.7). Convergent and divergent validity were demonstrated for most scales. CONCLUSION: High completion rates and satisfactory psychometric properties demonstrated that the Hypo-METRICS app is acceptable to adults with T1DM and T2DM, and a reliable and valid tool to explore the daily impact of hypoglycemia.


Assuntos
Diabetes Mellitus Tipo 1 , Diabetes Mellitus Tipo 2 , Hipoglicemia , Aplicativos Móveis , Adulto , Humanos , Pessoa de Meia-Idade , Idoso , Diabetes Mellitus Tipo 2/tratamento farmacológico , Diabetes Mellitus Tipo 2/psicologia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/psicologia , Psicometria , Reprodutibilidade dos Testes , Benchmarking , Smartphone , Hipoglicemia/psicologia , Insulina , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA