Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 231
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pain Med ; 24(2): 158-164, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-35944225

RESUMO

OBJECTIVE: To evaluate effectiveness and safety of computed tomography (CT)-guided cyst rupture with intraarticular contrast-enhanced injection of steroid and local anesthetic as first choice therapy in patients with facet joint cyst-induced radicular pain. DESIGN: Retrospective data set analysis. SETTING: University hospital. SUBJECTS: One hundred and twenty-one patients suffering from radicular pain attributable to facet joint cysts were included. METHODS: The rate of patients without following surgery was assessed and defined as surrogate to measure effectiveness. Patients' characteristics, procedure-associated complications, technical aspects, and imaging findings on magnetic resonance imaging (MRI) were analyzed. A subgroup of 65 patients (54%) underwent telephone interview to assess pain relief and clinical outcome measured by Numeric Rating Scale and Oswestry Disability Index. Analyses between the groups with and without surgery were performed by Fisher exact test and two-sample unpaired t-test, respectively. RESULTS: The effectiveness of CT-guided cyst rupture was found to be 66.1%. Procedure-induced pain yielded in premature abort in two cases (1.7%). The detection of epidural contrast agent was statistically significantly associated with no need for surgery (P = .010). The cyst level was associated with the status of following surgery (P = .026), that is, cysts at lower lumbar spine were easier to rupture than cysts at other locations (cervical, thoracic, or upper lumbar spine). No further significant association was found. CONCLUSIONS: CT-guided cyst rupture as the first-choice therapy in patients with cyst-induced radicular pain was safe and effective. Successful cyst rupture was associated with no need for surgery. Cysts at lower lumbar spine revealed the highest success rate.


Assuntos
Cistos , Dor Lombar , Cisto Sinovial , Articulação Zigapofisária , Humanos , Cisto Sinovial/complicações , Cisto Sinovial/diagnóstico por imagem , Cisto Sinovial/cirurgia , Articulação Zigapofisária/diagnóstico por imagem , Articulação Zigapofisária/cirurgia , Estudos Retrospectivos , Dor Lombar/terapia , Cistos/patologia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Artralgia/complicações , Resultado do Tratamento
2.
Clin Oral Investig ; 27(7): 3705-3712, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37039958

RESUMO

OBJECTIVES: Maxillary sinus mucositis is frequently associated with odontogenic foci. Periapical inflammation of maxillary molars and premolars cannot be visualized directly using radiation-based imaging. The purpose of this study was to answer the following clinical question: among patients with periapical inflammatory processes in the maxilla, does the use of magnetic resonance imaging (MRI), as compared to conventional periapical (AP) and panoramic radiography (OPT), improve diagnostic accuracy? METHODS: Forty-two subjects with generalized periodontitis were scanned on a 3 T MRI. Sixteen asymptomatic subjects with mucosal swelling of the maxillary sinus were enrolled in the study. Periapical edema was assessed using short tau inversion recovery (STIR) sequence. Apical osteolysis and mucosal swelling were assessed by MRI, AP, and OPT imaging using the periapical index score (PAI). Comparisons between groups were performed with chi-squared tests with Yates' correction. Significance was set at p < 0.05. RESULTS: Periapical lesions of maxillary premolars and molars were identified in 16 subjects, 21 sinuses, and 58 teeth. Bone edema and PAI scores were significantly higher using MRI as compared to OPT and AP (p < 0.05). Using the STIR sequence, a significant association of PAI score > 1 and the presence of mucosal swelling in the maxillary sinus was detected (p = 0.03). CONCLUSION: Periapical inflammation and maxillary mucositis could be visualized using STIR imaging. The use of MRI may help detect early, subtle inflammatory changes in the periapical tissues surrounding maxillary dentition. Early detection could guide diagnostic criteria, as well as treatment and prevention.


Assuntos
Mucosite , Periodontite Periapical , Humanos , Seio Maxilar/diagnóstico por imagem , Seio Maxilar/patologia , Estudos de Viabilidade , Inflamação/diagnóstico por imagem , Inflamação/patologia , Periodontite Periapical/complicações , Imageamento por Ressonância Magnética , Tomografia Computadorizada de Feixe Cônico/métodos
3.
HNO ; 71(10): 681-692, 2023 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-37702793

RESUMO

The combination of positron-emission tomography (PET) with cross-sectional imaging in particular is becoming increasingly important in the diagnosis of head and neck tumors because, in addition to pure anatomy, the metabolic activity of tissue can be visualized and assessed. The combination of PET and computed tomography (CT) is already an established procedure in head and neck tumor patients in some indications, e.g., for primary tumor detection in cancer of unknown primary (CUP) syndrome or also after completed primary radio(chemo)therapy for evaluation of response, especially also with regard to nodal status. In some cases, salvage neck dissection can thus be avoided in the case of PET-negative findings. In the context of primary diagnosis, PET/CT imaging can be used primarily to evaluate distant metastasis. According to current guidelines, PET-based imaging is not (yet) of value in determining the local extent at initial diagnosis. A challenge is the still limited reimbursement by health insurance companies, which currently allow only certain indications, and the still lack of nationwide coverage.


Assuntos
Neoplasias de Cabeça e Pescoço , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
4.
J Headache Pain ; 24(1): 84, 2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37438700

RESUMO

BACKGROUND: Tension-type headache (TTH) is the most prevalent primary headache disorder. Neck pain is commonly associated with primary headaches and the trigemino-cervical complex (TCC) refers to the convergence of trigeminal and cervical afferents onto neurons of the brainstem, thus conceptualizes the emergence of headache in relation to neck pain. However, no objective biomarkers exist for the myofascial involvement in primary headaches. This study aimed to investigate the involvement of the trapezius muscles in primary headache disorders by quantitative magnetic resonance imaging (MRI), and to explore associations between muscle T2 values and headache frequency and neck pain. METHODS: This cohort study prospectively enrolled fifty participants (41 females, age range 20-31 years): 16 subjects with TTH only (TTH-), 12 with mixed-type TTH plus migraine (TTH+), and 22 healthy controls (HC). The participants completed fat-suppressed T2-prepared three-dimensional turbo spin-echo MRI, a headache diary (over 30 days prior to MRI), manual palpation (two weeks before MRI), and evaluation of neck pain (on the day of MRI). The bilateral trapezius muscles were manually segmented, followed by muscle T2 extraction. Associations between muscle T2 and the presence of neck pain as well as the number of days with headache (considering the 30 days prior to imaging using the headache calendar) were analyzed using regression models (adjusting for age, sex, and body mass index). RESULTS: The TTH+ group demonstrated the highest muscle T2 values (right side: 31.4 ± 1.2 ms, left side: 31.4 ± 0.8 ms) as compared to the TTH- group or HC group (p < 0.001). Muscle T2 was significantly associated with the number of headache days (ß-coefficient: 2.04, p = 0.04) and the presence of neck pain (odds ratio: 2.26, p = 0.04). With muscle T2 as the predictor, the area under the curve for differentiating between HC and the TTH+ group was 0.82. CONCLUSIONS: Increased T2 of trapezius muscles may represent an objective imaging biomarker for myofascial involvement in primary headache disorders, which could help to improve patient phenotyping and therapy evaluation. Pathophysiologically, the increased muscle T2 values could be interpreted as a surrogate of neurogenic inflammation and peripheral sensitization within myofascial tissues.


Assuntos
Músculos Superficiais do Dorso , Cefaleia do Tipo Tensional , Feminino , Adulto Jovem , Humanos , Adulto , Cefaleia do Tipo Tensional/diagnóstico por imagem , Cervicalgia/diagnóstico por imagem , Estudos de Coortes , Músculos Superficiais do Dorso/diagnóstico por imagem , Cefaleia
5.
J Anat ; 240(1): 120-130, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34346505

RESUMO

The morphology of the rib cage affects both the biomechanics of the upper body's musculoskeletal structure and the respiratory mechanics. This becomes particularly important when evaluating skeletal deformities, as in adolescent idiopathic scoliosis (AIS). The aim of this study was to identify morphological characteristics of the rib cage in relation to the lung in patients with non-deformed and scoliotic spines. Computed tomography data of 40 patients without any visible spinal abnormalities (healthy group) and 21 patients with AIS were obtained retrospectively. All bony structures as well as the right and left lung were reconstructed using image segmentation. Morphological parameters were calculated based on the distances between characteristic morphological landmarks. These parameters included the rib position, length, and area, the rib cage depth and width, and the rib inclination angle on either side, as well as the spinal height and length. Furthermore, we determined the left and right lung volumes, and the area of contact between the rib cage and lung. Differences between healthy and scoliotic spines were statistically analysed using the t-test for unpaired data. The rib cage of the AIS group was significantly deformed in the dorso-ventral and medio-lateral directions. The anatomical proximity of the lung to the ribs was nearly symmetrical in the healthy group. By contrast, within the AIS group, the lung covered a significantly greater area on the left side of the rib cage at large thoracic deformities. Within the levels T1-T6, no significant difference in the rib length, depth to width relationship, or area was observed between the healthy and AIS groups. Inferior to the lung (T7-T12), these parameters exhibited greater variability. The ratio between the width of the rib cage at T6 and the thoracic spinal height (T1-T12) was significantly increased within the thoracic AIS group (1.1 ± 0.08) compared with the healthy group (1.0 ± 0.05). No statistical differences were found between the lung volumes among all the groups. While the rib cage was frequently strongly deformed in the AIS group, the lung and its surrounding ribs appeared to be normally developed. The observed rib hump in AIS appeared to be formed particularly by a more ventral position of the ribs on the concave side. Furthermore, the rib cage width to spinal height ratio suggested that the spinal height of the thoracic AIS-spine is reduced. This indicates that the spine would gain its growth-related height after correcting the spinal deformity. These are the important aspects to consider in the aetiology research and orthopaedic treatment of AIS.


Assuntos
Cifose , Escoliose , Adolescente , Humanos , Pulmão/diagnóstico por imagem , Estudos Retrospectivos , Caixa Torácica/diagnóstico por imagem , Escoliose/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem
6.
BMC Musculoskelet Disord ; 23(1): 724, 2022 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-35906573

RESUMO

BACKGROUND: Demographic change entails an increasing incidence of fragility fractures. Dual-energy CT (DECT) with virtual non-calcium (VNCa) reconstructions has been introduced as a promising diagnostic method for evaluating bone microarchitecture and marrow simultaneously. This study aims to define the most accurate cut-off value in Hounsfield units (HU) for discriminating the presence and absence of bone marrow edema (BME) in sacral fragility fractures. METHODS: Forty-six patients (40 women, 6 men; 79.7 ± 9.2 years) with suspected fragility fractures of the sacrum underwent both DECT (90 kVp / 150 kVp with tin prefiltration) and MRI. Nine regions-of-interest were placed in each sacrum on DECT-VNCa images. The resulting 414 HU measurements were stratified into "edema" (n = 80) and "no edema" groups (n = 334) based on reference BME detection in T2-weighted MRI sequences. Area under the receiver operating characteristic curve was calculated to determine the desired cut-off value and an associated conspicuity range for edema detection. RESULTS: The mean density within the "edema" group of measurements (+ 3.1 ± 8.3 HU) was substantially higher compared to the "no edema" group (-51.7 ± 21.8 HU; p < 0.010). Analysis in DECT-VNCa images suggested a cut-off value of -12.9 HU that enabled sensitivity and specificity of 100% for BME detection compared to MRI. A range of HU values between -14.0 and + 20.0 is considered indicative of BME in the sacrum. CONCLUSIONS: Quantitative analysis of DECT-VNCa with a cut-off of -12.9 HU allows for excellent diagnostic accuracy in the assessment of sacral fragility fractures with associated BME. A diagnostic "one-stop-shop" approach without additional MRI is feasible.


Assuntos
Doenças da Medula Óssea , Fraturas Ósseas , Lesões do Pescoço , Osteoporose , Fraturas da Coluna Vertebral , Medula Óssea/diagnóstico por imagem , Doenças da Medula Óssea/diagnóstico por imagem , Doenças da Medula Óssea/etiologia , Edema/diagnóstico por imagem , Edema/etiologia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/complicações , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
7.
Clin Anat ; 35(3): 354-358, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35128729

RESUMO

To evaluate the educational benefits of teaching ultrasound in an elective radiological course for medical students. We conducted a single-center retrospective analysis of a one-week elective ultrasound course in which 39 medical students (25 female; median age 25.8 ± 2.8 years, range 21-35, 4th and 5th years of undergraduate medical education) participated as part of their radiological training. The students completed a pre- and post-course questionnaire using a five-point Likert scale for self-assessment of technical knowledge, confidence in the procedure regarding different organs, motivation for performing ultrasound, and the importance of ultrasound in medical education. The students also assessed the value of ultrasound teaching in the context of their general medical degree. Pre-test and post-test scores showed significantly improved radiology knowledge (p ≤ 0.001) concerning all abdominal organs (liver, spleen, gallbladder, kidney, urinary bladder, aorta and retroperitoneum). A significant improvement was registered in performing ultrasound of peripheral arteries and venous structures (each p = 0.001), and also of the thyroid gland (p = 0.006). General surveys at the end of the elective were overwhelmingly positive, with constructive criticism and complimentary comments. Systematic training in ultrasound markedly improved the students' skills. This was especially pronounced for solid organ structures, while students requested more education regarding the retroperitoneum and vascular structures. Teaching ultrasound in an elective hands-on training course improves anatomical understanding and practical skills associated with increased motivation. The results affirm the necessity and clinical relevance of the course during the radiological training of medical students.


Assuntos
Educação de Graduação em Medicina , Estudantes de Medicina , Adulto , Competência Clínica , Currículo , Educação de Graduação em Medicina/métodos , Avaliação Educacional , Feminino , Humanos , Estudos Retrospectivos , Ultrassonografia , Adulto Jovem
8.
AJR Am J Roentgenol ; 216(2): 453-463, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33325736

RESUMO

OBJECTIVE. The aim of this phantom study was to determine whether low-dose CT of the pelvis can be performed using a dose similar to that used in a standard radio-graphic examination and to ascertain whether CT, with its better delineation of complex structures, has greater clinical value than radiography and therefore will result in improved patient care. Special consideration was given to CT performed using the tin filtration technique. MATERIALS AND METHODS. For dose comparison, an anthropomorphic phantom with 20 thermoluminescent dosimeters, two different CT scanners, and three conventional radiography devices were used. Seven CT protocols (including tin filtration) and four different radiographic examinations were performed. Dose calculations, objective and subjective evaluations of image quality, and figure-of-merit calculations were compared among the techniques. Furthermore, the images obtained were evaluated in a clinical context. Intraclass correlation was determined for the subjective results. RESULTS. The dose values of the tested low-dose CT protocols, in particular those using the tin filtration technique, corresponded to or were only slightly higher than the dose values of conventional pelvic radiographic images obtained in three views. Low-dose CT examinations were rated sufficient for consolidation control and had an informative value that was significantly higher than that of conventional radiography. Tin filtering showed the best results for low-dose CT in terms of combining dose and clinically relevant image quality. CONCLUSION. In this phantom study, low-dose CT was superior to radiography for visualizing and evaluating the dorsal pelvic ring, with only marginally higher radiation exposure occurring when the latest-generation CT systems were used. Tin filtration can improve image quality, create further dose reductions, or provide both benefits.


Assuntos
Pelve/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação , Humanos , Dosimetria Termoluminescente
9.
Eur J Nucl Med Mol Imaging ; 47(10): 2339-2347, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32157427

RESUMO

PURPOSE: 68Ga-PSMA-11-PET/CT is increasingly used in early-stage biochemical recurrence of prostate cancer to detect potential lesions for an individualized radiotherapy concept. However, subtle findings especially concerning small local recurrences can still be challenging to interpret and are prone to variability between different readers. Thus, we analyzed interobserver variability, detection rate, and lesion patterns systematically in a homogeneous patient population with low-level biochemical recurrence. METHODS: We analyzed 68Ga-PSMA-11-PET/CTs in 116 patients with status post-prostatectomy and PSA levels up to 0.6 ng/ml. None of them received ADT or radiotherapy beforehand. Images were interpreted and blinded by two nuclear medicine physicians (R1 and R2). Findings were rated using a 5-point scale concerning local recurrence, lymph nodes, bone lesions, and other findings (1: definitely benign, 2: probably benign, 3: equivocal, 4: probably malignant, 5: definitely malignant). In findings with substantial discrepancies of 2 or more categories and/or potentially leading to differences in further patient management, a consensus reading was done with a third reader (R3). Interobserver agreement was measured by Cohens Kappa analysis after sub-categorizing our classification system to benign (1 + 2), equivocal (3), and malignant (4 + 5). Time course of PSA levels after salvage treatment of patients rated as positive (4 + 5) was analyzed. RESULTS: The overall detection rate (categories 4 and 5) was 50% (R1/R2, 49%/51%) and in the PSA subgroups 0-0.2 ng/ml, 0.21-0.3 ng/ml, and 0.31-0.6 ng/ml 24%/27%, 57%/57%, and 65%/68%, respectively. Local recurrence was the most common lesion manifestation followed by lymphatic and bone metastases. The overall agreement in the Cohens Kappa analysis was 0.74 between R1 and R2. For local, lymphatic, and bone sites, the agreement was 0.76, 0.73, and 0.58, respectively. PSA levels of PSMA PET/CT-positive patients after salvage treatment decreased in 75% (27/36) and increased in 25% (9/36). A decrease of PSA, although more frequent in patients with imaging suggesting only local tumor recurrence (86%, 18/21), was also observed in 67% (10/15) of patients with findings of metastatic disease. CONCLUSIONS: In a highly homogeneous group of prostate cancer patients with early-stage biochemical recurrence after radical prostatectomy, we could show that 68Ga-PSMA-11-PET/CT has a good detection rate of 50% which is in accordance with literature, with clinically relevant findings even in patients with PSA < 0.21 ng/ml. The interobserver variability is low, particularly concerning assessment of local recurrences and lymph nodes. Therefore, PSMA-PET/CT is a robust diagnostic modality in this patient group for therapy planning.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Ácido Edético/análogos & derivados , Isótopos de Gálio , Radioisótopos de Gálio , Humanos , Masculino , Recidiva Local de Neoplasia/diagnóstico por imagem , Variações Dependentes do Observador , Oligopeptídeos , Antígeno Prostático Específico , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Recidiva
10.
J Magn Reson Imaging ; 52(5): 1550-1556, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32379382

RESUMO

BACKGROUND: Liver iron overload is a serious condition occurring in patients requiring blood transfusions (eg, in thalassemia and different forms of anemia) or with dysfunctional iron resorption, since there is no physiological mechanism to excrete iron. Above a certain level of iron concentration, chelation therapy is indicated. To monitor therapy success, liver iron content should be assessed regularly. A noninvasive method is important for patient management. Existing MRI methods suffer from long acquisition times and cost. PURPOSE: To study the correlation of liver iron content (LIC) reference values to liver R2 * determined using a 3D breath-hold multigradient echo (GRE) MRI sequence, employing accelerated acquisition by parallel imaging and in-line R2 * calculation. STUDY TYPE: Prospective. POPULATION: In all, 117 patients (22.1 ± 14.1 years, 66 men) suspected of iron overload. SEQUENCE: GRE. FIELD STRENGTH: 1.5T. ASSESSMENT: For comparison, a regulatory-approved method with a considerably longer scan time was used, providing LIC reference values. Participants were divided into a calibration group (65 participants), analyzed independently by two observers, and a validation group (52 participants). STATISTICAL TESTS: Linear correlation parameters were evaluated for R2 * values with LIC reference values, and for LIC determined from R2 * for validation group participants with LIC reference values. Sensitivity/specificity for clinical relevant LIC thresholds were analyzed. Interobserver variability was determined by intraclass correlation coefficient (ICC). RESULTS: Interobserver agreement was excellent, with an ICC of 0.99, P < 0.001. Good correlation (R2 = 0.89) and congruence of LIC values obtained with our method to LIC reference values was found, and almost identical diagnostic accuracy. Sensitivity/specificity were 0.98/0.67 for the diagnostic relevant LIC threshold of 4.5 mg/g and 1.0/0.95 for the threshold of 7 mg/g. DATA CONCLUSION: MRI acquisition times for determination of LIC can be significantly reduced by the use of comprehensive in-line R2 * map generation without compromising diagnostic accuracy. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Sobrecarga de Ferro , Ferro , Humanos , Sobrecarga de Ferro/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Estudos Prospectivos
11.
J Magn Reson Imaging ; 52(6): 1637-1644, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32652765

RESUMO

BACKGROUND: Imaging of the lung by MRI is challenging due to the intrinsic low proton density and rapid T2 * relaxation. MRI methods providing lung parenchyma and function are in demand. PURPOSE: To investigate the feasibility of two-dimensional ultrashort echo-time (2D UTE) imaging for lung function assessment. STUDY TYPE: Prospective. POPULATION: Eleven healthy volunteers. FIELD STRENGTH/SEQUENCE: 3T, 2D tiny golden angle UTE (2D-tyUTE). ASSESSMENT: The applicability of breath-hold (BH) and self-gated (SG) 2D-tyUTE for quantification of the lung parenchyma signal-to-noise ratio (SNR), proton fraction (fP ), fractional ventilation (FV), and perfusion (f) was investigated. Dependencies on repetition time (BHS/I1/I2 ) and respiratory phase (expiration [EX], inspiration [IN]) were investigated and compared between smokers and nonsmokers. STATISTICAL TESTS: Analysis of variance (ANOVA), Kendell's W. RESULTS: Significant differences of SNR (EX: 10.98 ± 3.19(BHS ), 14.58 ± 3.89(BHI1 ), 17.59 ± 4.92(BHI2 ), 11.00 ± 5.42(SG); IN: 7.17 ± 2.07(BHS ), 9.51 ± 2.37(BHI1 ), 10.49 ± 2.33(BHI2 ), 10.00 ± 4.14(SG)) (P < 0.05 for all cases) were observed between the different approaches. Where fP in expiration (0.41 ± 0.13) was independent of the BH imaging technique, it was slightly higher in SG (0.44 ± 0.06). FV was reproducible among the BH techniques (0.41 ± 0.10), but significantly lower in SG (0.21 ± 0.06) (P < 0.05). A moderate correlation (R2 = 0.47, P < 0.01) was observed between the breathing amplitude and FV. No significant differences between BH and SG were observed for the perfusion analysis (EX: 3.50 ± 1.29 mL/min/mL [BHS ]; IN: 2.36 ± 1.05 mL/min/mL [BHS ]). Significant differences in fP were found between smokers (0.48 ± 0.11 BH) and nonsmokers (0.37 ± 0.12 BH) in expiration. DATA CONCLUSION: This study demonstrates the feasibility of 2D-tyUTE for successful quantification of relevant lung function parameters at 3T within clinically attractive acquisition times. The low spatial resolution into the slice selection direction may limit the final sensitivity and needs further clinical evaluation. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1 J. MAGN. RESON. IMAGING 2020;52:1637-1644.


Assuntos
Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Humanos , Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética , Estudos Prospectivos , Razão Sinal-Ruído
12.
AJR Am J Roentgenol ; 215(4): 945-953, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32783561

RESUMO

OBJECTIVE. The purpose of this study was to determine in a phantom the dose exposure of different dental 3D sectional imaging methods (CT and cone-beam CT [CBCT]) and different CT protocols. The aim was to establish optimal protocols with the lowest possible dose and diagnostically high image quality with special consideration given to tin prefiltration. MATERIALS AND METHODS. Dose was determined with thermoluminescence detectors at 20 different measuring points on an anthropomorphic phantom. Eight different CT protocols with and without tin filtering were compared with iterative reconstruction methods and a standard CBCT protocol. Objective and subjective image evaluations and a figure-of-merit analysis of the image data were performed by radiologists and maxillofacial surgeons. RESULTS. The determined dose-length products of the nine examinations were 5.0-111.9 mGy · cm with a calculated effective whole body dose of 20.7-505.9 µSv. Cone-beam CT was in the upper midfield with an effective dose of 229.3 µSv. On the basis of dose, objective image quality, and clinical evaluation results, tin filter protocols performed best. Protocols with higher doses were significantly less useful in the figure of merit comparison but because of their detailed bony representation are particularly necessary to answer certain questions about trauma and tumors. CONCLUSION. The use of tin filtering can reduce dose in dental CT examinations, compared with standard low-dose examinations, while maintaining good image quality. The dose performance is significantly inferior even to that of a cone-beam CT examination. High-dose protocols are necessary only for certain questions.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Cabeça/diagnóstico por imagem , Imageamento Tridimensional , Tomografia Computadorizada Multidetectores , Doses de Radiação , Radiografia Dentária , Protocolos Clínicos , Humanos , Imagens de Fantasmas , Estanho
13.
Acta Radiol ; 61(6): 768-775, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31569948

RESUMO

BACKGROUND: Iterative reconstruction is well established for CT. Plain radiography also takes advantage of iterative algorithms to reduce scatter radiation and improve image quality. First applications have been described for bedside chest X-ray. A recent experimental approach also provided proof of principle for skeletal imaging. PURPOSE: To examine clinical applicability of iterative scatter correction for skeletal imaging in the trauma setting. MATERIAL AND METHODS: In this retrospective single-center study, 209 grid-less radiographs were routinely acquired in the trauma room for 12 months, with imaging of the chest (n = 31), knee (n = 111), pelvis (n = 14), shoulder (n = 24), and other regions close to the trunk (n = 29). Radiographs were postprocessed with iterative scatter correction, doubling the number of images. The radiographs were then independently evaluated by three radiologists and three surgeons. A five-step rating scale and visual grading characteristics analysis were used. The area under the VGC curve (AUCVGC) quantified differences in image quality. RESULTS: Images with iterative scatter correction were generally rated significantly better (AUCVGC = 0.59, P < 0.01). This included both radiologists (AUCVGC = 0.61, P < 0.01) and surgeons (AUCVGC = 0.56, P < 0.01). The image-improving effect was significant for all body regions; in detail: chest (AUCVGC = 0.64, P < 0.01), knee (AUCVGC = 0.61, P < 0.01), pelvis (AUCVGC = 0.60, P = 0.01), shoulder (AUCVGC = 0.59, P = 0.02), and others close to the trunk (AUCVGC = 0.59, P < 0.01). CONCLUSION: Iterative scatter correction improves the image quality of grid-less skeletal radiography in the clinical setting for a wide range of body regions. Therefore, iterative scatter correction may be the future method of choice for free exposure imaging when an anti-scatter grid is omitted due to high risk of tube-detector misalignment.


Assuntos
Osso e Ossos/diagnóstico por imagem , Osso e Ossos/lesões , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiografia/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Espalhamento de Radiação , Adulto Jovem
14.
Mol Genet Metab ; 126(2): 169-182, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30594474

RESUMO

BACKGROUND: Initiation of enzyme replacement therapy (ERT) early in the Fabry disease course may facilitate better outcomes than in patients with advanced disease. Early diagnosis is often hindered by the heterogeneous nature of signs and symptoms, and by the presentation of atypical phenotypes. METHODS: The Sophisticated Assessment of Disease Burden in Patients with Fabry Disease study (SOPHIA; ClinicalTrials.gov, NCT01210196) evaluated clinical and diagnostic assessments for early detection of Fabry-related organ pathology in ERT-naïve patients with mild FD symptoms. Assessments included cardiac magnetic resonance imaging with late gadolinium enhancement (LGE-CMR), echocardiography, 24-h Holter electrocardiography, and biomarkers of FD and fibrosis. RESULTS: 35 patients with mean (SD) baseline age of 45.0 (10.2) years were included and assessed at baseline, 12 months, and (optionally) at 24 months. At baseline, LGE-CMR and elevated procollagen III N-terminal propeptide, sphingosine-1-phosphate, and globotriaosylsphingosine were the most prevalent indicators of early Fabry-related pathology. LGE was already present in 58.8% of patients with normal left ventricular mass index. 15.2% of patients showed grade 1 diastolic dysfunction. QRS duration increased from baseline to last observation, particularly in patients with severe baseline fibrosis. Fibrosis progressed from baseline to last observation, especially in patients with baseline LGE ≥ 2.50 mL (3.65 [1.14] mL vs 6.74 [1.10] mL). Statistically significant correlations were found between LGE volume and high-sensitivity troponin T, and between LGE volume and fragments of urinary collagen alpha-1 (I), (III), and (VII), and collagen alpha-3 (V). CONCLUSIONS: Fibrosis may become apparent before left ventricular hypertrophy occurs. LGE-CMR imaging is superior to conventional echocardiography for detecting early cardiomyopathy in FD and, in conjunction with biomarker tests, may help detect early organ involvement in mild FD.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Diagnóstico Precoce , Doença de Fabry/complicações , Doença de Fabry/diagnóstico , Adulto , Idoso , Biomarcadores/sangue , Biomarcadores/urina , Cardiomiopatias/fisiopatologia , Progressão da Doença , Feminino , Fibrose , Gadolínio/química , Coração/diagnóstico por imagem , Humanos , Hipertrofia Ventricular Esquerda/etiologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Disfunção Ventricular Esquerda/etiologia
15.
AJR Am J Roentgenol ; 212(3): 607-613, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30645158

RESUMO

OBJECTIVE: The eye lens is one of the most radiosensitive organs, and medical radiation is one of the main causes of cataracts. To protect the lens during head CT examinations, protectors have been developed; however, they can lead to image artifacts, which is a major disadvantage of their use. This study retrospectively evaluates the frequency and extent of artifacts caused by these protectors related to three anatomic regions (eye, brain, and bone) and their dependence on protector positioning. MATERIALS AND METHODS: Datasets from 261 consecutive head CT examinations obtained during 3.5 months of routine clinical imaging were assessed. Diagnostic quality of the images was evaluated by objective measuring and subjective scoring on a 5-point Likert scale. Furthermore, the position of the lens protector in correlation to the eye lens and the intensity and frequency of artifacts were analyzed. RESULTS: Only 4.6% of all analyzed examinations were completely free from artifacts; 95.4% showed artifacts at least in the orbital cavity. Although the brain was affected in 27.8% of cases, in only 5.8% of cases was there a risk of misinterpretation, such as suspected intracranial bleeding. In 24.9% of cases, the lens was not properly covered by the protector. A too cranial position of the protector was identified as the main risk factor for cerebral artifacts. CONCLUSION: Eye shielding for brain CT examinations often leads to artifacts. However, in only a small percentage of cases do these artifacts affect tissue depiction in regions beyond the eye (i.e., brain or bones). Correct positioning is mandatory to minimize artifacts.


Assuntos
Artefatos , Dispositivos de Proteção dos Olhos , Cristalino/efeitos da radiação , Proteção Radiológica/instrumentação , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Estudos Retrospectivos
16.
Neuroradiology ; 61(8): 953-956, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31104077

RESUMO

CT-resolution depends on tube focal spot size. To investigate the effect of reducing focal spot on vessel wall clarity, 22 patients underwent head and neck CTA acquisition with large and small focal spot size. Hounsfield density profile was assessed for each head and neck vessel separately, and significantly sharper density increase at vessel borders was observed using smaller tube focus by an average of 9.9% to 82° angle degrees (p < .05). In conclusion, spatial resolution of CTA of head and neck vessels can be improved by using the small x-ray tube focal spot.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Cabeça/irrigação sanguínea , Cabeça/diagnóstico por imagem , Pescoço/irrigação sanguínea , Pescoço/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
17.
Respiration ; 97(4): 370-402, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30041191

RESUMO

In Germany, 10,000 cases of spontaneous pneumothorax are treated inpatient every year. The German Society for Thoracic Surgery, in co-operation with the German Society for Pulmonology, the German Radiological Society, and the German Society of Internal Medicine has developed an S3 guideline on spontaneous pneumothorax and post-interventional pneumothorax moderated by the German Association of Scientific Medical Societies. METHOD: Based on the source guideline of the British Thoracic Society (2010) for spontaneous pneumothorax, a literature search on spontaneous pneumothorax was carried out from 2008 onwards, for post-interventional pneumothorax from 1960 onwards. Evidence levels according to the Oxford Center for Evidence-Based Medicine (2011) were assigned to the relevant studies found. Recommendations according to grade (A: "we recommend"/"we do not recommend," B: "we suggest"/"we do not suggest") were determined in 3 consensus conferences by the nominal group process. RESULTS: The algorithms for primary and secondary pneumothorax differ in the indication for CT scan as well as in the indication for chest drainage application and video-assisted thoracic surgery. Indication for surgery is recommended individually taking into account the risk of recurrence, life circumstances, patient preferences, and procedure risks. For some forms of secondary pneumothorax, a reserved indication for surgery is recommended. Therapy of post-interventional spontaneous pneumothorax is similar to that of primary spontaneous pneumothorax. DISCUSSION: The recommendations of the S3 Guideline provide assistance in managing spontaneous pneumothorax and post-interventional pneumothorax. Whether this will affect existing deviant diagnostic and therapeutic measures will be demonstrated by future epidemiological studies.


Assuntos
Pneumotórax/terapia , Drenagem , Alemanha , Humanos , Pneumotórax/diagnóstico por imagem , Pneumotórax/epidemiologia , Radiografia Torácica , Cirurgia Torácica Vídeoassistida
18.
BMC Med Imaging ; 19(1): 39, 2019 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-31113389

RESUMO

BACKGROUND: Pulmonary involvement is common in several infectious and non-infectious diagnostic settings. Imaging findings consistently overlap and are therefore difficult to differentiate by chest-CT. The aim of this study was to evaluate the role of CT-textural features(CTTA) for discrimination between atypical viral (respiratory-syncitial-virus(RSV) and herpes-simplex-1-virus (HSV1)), fungal (pneumocystis-jirovecii-pneumonia(PJP)) interstitial pneumonias and alveolar hemorrhage. METHODS: By retrospective single-centre analysis we identified 46 consecutive patients (29 m) with RSV(n = 5), HSV1(n = 6), PJP(n = 21) and lung hemorrhage(n = 14) who underwent unenhanced chest CTs in early stages of the disease between 01/2016 and 02/2017. All cases were confirmed by microbiologic direct analysis of bronchial lavage. On chest-CT-scans, the presence of imaging features like ground-glass opacity(GGO), crazy-paving, air-space consolidation, reticulation, bronchial wall thickening and centrilobular nodules were described. A representative large area was chosen in both lungs and used for CTTA-parameters (included heterogeneity, intensity, average, deviation, skewness). RESULTS: Discriminatory CTTA-features were found between alveolar hemorrhage and PJP consisting of differences in mean heterogeneity(p < 0.015) and uniformity of skewness(p < 0.006). There was no difference between CT-textural features of diffuse alveolar hemorrhage and viral pneumonia or PJP and viral pneumonia. Visual HRCT-assessment yielded great overlap of imaging findings with predominance of GGO for PJP and airspace consolidation for pneumonia/alveolar hemorrhage. Significant correlations between HRCT-based imaging findings and CT-textural features were found for all three disease groups. CONCLUSION: CT-textural features showed significant differences in mean heterogeneity and uniformity of skewness. HRCT-based imaging findings correlated with certain CT-textural features showing that the latter have the potential to characterize structural properties of lung parenchyma and related abnormalities.


Assuntos
Hemorragia/diagnóstico por imagem , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Pneumonia por Pneumocystis/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/microbiologia , Masculino , Pessoa de Meia-Idade , Pneumocystis carinii/isolamento & purificação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
19.
BMC Pulm Med ; 19(1): 269, 2019 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-31888580

RESUMO

BACKGROUND: Skeletal muscle function dysfunction has been reported in patients with cystic fibrosis (CF). Studies so far showed inconclusive data whether reduced exercise capacity is related to intrinsic muscle dysfunction in CF. METHODS: Twenty patients with CF and 23 age-matched controls completed an incremental cardiopulmonary cycling test. Further, a Wingate anaerobic test to assess muscle power was performed. In addition, all participants completed an incremental knee-extension test with 31P magnetic resonance spectroscopy to assess muscle metabolism (inorganic phosphate (Pi) and phosphocreatinine (PCr) as well as intracellular pH). In the MRI, muscle cross-sectional area of the M. quadriceps (qCSA) was also measured. A subgroup of 15 participants (5 CF, 10 control) additionally completed a continuous high-intensity, high-frequency knee-extension exercise task during 31P magnetic resonance spectroscopy to assess muscle metabolism. RESULTS: Patients with CF showed a reduced exercise capacity in the incremental cardiopulmonary cycling test (VO2peak: CF 77.8 ± 16.2%predicted (36.5 ± 7.4 ml/qCSA/min), control 100.6 ± 18.8%predicted (49.1 ± 11.4 ml/qCSA/min); p < 0.001), and deficits in anaerobic capacity reflected by the Wingate test (peak power: CF 537 ± 180 W, control 727 ± 186 W; mean power: CF 378 ± 127 W, control 486 ± 126 W; power drop CF 12 ± 5 W, control 8 ± 4 W. all: p < 0.001). In the knee-extension task, patients with CF achieved a significantly lower workload (p < 0.05). However, in a linear model analysing maximal work load of the incremental knee-extension task and results of the Wingate test, respectively, only muscle size and height, but not disease status (CF or not) contributed to explaining variance. In line with this finding, no differences were found in muscle metabolism reflected by intracellular pH and the ratio of Pi/PCr at submaximal stages and peak exercise measured through MRI spectroscopy. CONCLUSIONS: The lower absolute muscle power in patients with CF compared to controls is exclusively explained by the reduced muscle size in this study. No evidence was found for an intrinsic skeletal muscle dysfunction due to primary alterations of muscle metabolism.


Assuntos
Fibrose Cística/metabolismo , Fibrose Cística/fisiopatologia , Força Muscular , Músculo Esquelético/metabolismo , Músculo Esquelético/fisiopatologia , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Feminino , Humanos , Masculino , Músculo Esquelético/patologia , Tamanho do Órgão , Adulto Jovem
20.
Acta Radiol ; 60(6): 735-741, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30149748

RESUMO

BACKGROUND: Iterative scatter correction (ISC) is a new technique applicable to plain radiography; comparable to iterative reconstruction for computed tomography, it promises dose reduction and image quality improvement. ISC for bedside chest X-rays has been applied and evaluated for some time and has recently been commercially offered for plain skeletal radiography. PURPOSE: To analyze the potential of ISC for plain skeletal radiography with regard to image quality improvement, dose reduction, and replacement for an antiscatter grid. MATERIAL AND METHODS: A total of 385 radiographs with different imaging protocols of the pelvis and cervical spine were acquired from 20 body donors. Radiographs were rated by four radiologists. Ratings were analyzed with visual grading characteristics (VGC) analysis. The area under the VGC curve was used as a measure of difference in image quality. RESULTS: Without ISC, the grid-less images were rated significantly worse than their grid-based counterparts (0.389, P = 0.005); adding ISC made image quality equal (0.498; P = 0.963). In grid-less imaging, reduction of dose by 50% led to significant image quality impairment (0.415, P = 0.001); this was fully counterbalanced when ISC was added (0.512; P = 0.588). CONCLUSION: ISC for plain skeletal radiography has the ability to replace the antiscatter grid without image quality impairment, to improve image quality in grid-less imaging, and to reduce patient radiation dose by 50% without substantial loss in image quality.


Assuntos
Vértebras Cervicais/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Pelve/diagnóstico por imagem , Intensificação de Imagem Radiográfica/métodos , Radiografia/métodos , Cadáver , Bases de Dados Factuais , Feminino , Humanos , Masculino , Doses de Radiação , Intensificação de Imagem Radiográfica/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA