Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Clin Invest ; 53(6): e13969, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36776121

RESUMO

BACKGROUND AND AIMS: Transvenous lead extraction (TLE) has become a pivotal part of a comprehensive lead management strategy, dealing with a continuously increasing demand. Nonetheless, the literature about the long-term impact of TLE on survivals is still lacking. Given these knowledge gaps, the aim of our study was to analyse very long-term mortality in patients undergoing TLE in public health perspective. METHODS: This prospective, single-centre, observational study enrolled consecutive patients with cardiac implantable electronic device (CIED) who underwent TLE, from January 2005 to January 2021. The main goal was to establish the independent predictors of very long-term mortality after TLE. We also aimed at assessing procedural and hospitalization-related costs. RESULTS: We enrolled 435 patients (mean age 70 ± 12 years, with mean lead dwelling time 6.8 ± 16.7 years), with prevalent infective indication to TLE (92%). Initial success of TLE was achieved in 98% of population. After a median follow-up of 4.5 years (range: 1 month-15.5 years), 150 of the 435 enrolled patients (34%) died. At multivariate analysis, death was predicted by: age (≥77 years, OR: 2.55, CI: 1.8-3.6, p < 0.001), chronic kidney disease (CKD) defined as severe reduction of estimated glomerular filtration rate (eGFR <30 mL/min/1.73 m2 , OR: 1.75, CI: 1.24-2.4, p = 0.001) and systolic dysfunction assessed before TLE defined as left ventricular ejection fraction (LVEF) <40%, OR: 1.78, CI 1.26-2.5, p = 0.001. Mean extraction cost was €5011 per patient without reimplantation and €6336 per patient with reimplantation respectively. CONCLUSIONS: Our study identified three predictors of long-term mortality in a high-risk cohort of patients with a cardiac device infection, undergoing successful TLE. The future development of a mortality risk score before might impact on public health strategy.


Assuntos
Desfibriladores Implantáveis , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Desfibriladores Implantáveis/efeitos adversos , Estudos Prospectivos , Volume Sistólico , Função Ventricular Esquerda , Fatores de Risco , Resultado do Tratamento , Estudos Retrospectivos
2.
Rev Cardiovasc Med ; 23(2): 43, 2022 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-35229534

RESUMO

Despite continuous technological developments, transvenous pacemakers (PM) are still associated with significant immediate and long-term complications, mostly lead or pocket-related. Recent technological advances brought to the introduction in clinical practice of leadless PM for selected cohort of patients. These miniaturize devices are implanted through the femoral vein and advanced to the right ventricle, without leaving leads in place. Lack of upper extremity vascular access and/or high infective risk in patients requiring VVI pacing are the most common indications to leadless PM. The recently introduced MICRA AV leadless PM also allows ventricular synchronization through mechanical sensing of atrial contraction waves, thus solving the problem of AV synchronization. This review will discuss and summarize available clinical evidence on leadless PM, their performance compared to transvenous devices, current applications and future perspectives.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Estimulação Cardíaca Artificial/efeitos adversos , Desenho de Equipamento , Ventrículos do Coração , Humanos
3.
Pacing Clin Electrophysiol ; 44(10): 1769-1780, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34486141

RESUMO

Transvenous lead extraction (TLE) has seen a rapid expansion in the past 20 years. The procedure has changed from early techniques involving simple manual traction that frequently proved themselves ineffective for chronically implanted leads, and carried significant periprocedural risks including death, to the availability of a wide range of more efficacious techniques and tools, providing the skilled extractor with a well-equipped armamentarium. The reduction in morbidity and mortality associated with these new extraction techniques has widened indications to TLE from prevalent use in life-threatening situations, such as infection and sepsis, to a more widespread use even in noninfectious situations such as malfunctioning leads. Powered sheaths have been a remarkable step forward in this improvement in TLE procedures and recent registries at high-volume centers report high success rates with exceedingly low complication rates. This review is aimed at describing technical features of powered sheaths as well as reported performance during TLE procedures.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo/métodos , Eletrodos Implantados , Humanos
4.
Pacing Clin Electrophysiol ; 44(10): 1657-1662, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34314032

RESUMO

BACKGROUND: Sleep apnea syndrome (SAS) has been reported to be associated with a higher incidence of ventricular arrhythmias. The aim of this study was twofold: (1) to investigate whether in SAS patients receiving an implantable cardioverter defibrillator (ICD) the severity of SAS was associated with the occurrence of ventricular arrhythmias; (2) to assess whether changes in nocturnal apnoic/hypopnoic episodes may favor the occurrence of life-threatening arrhythmias, that is, sustained ventricular tachycardia (VT)/fibrillation (VF), requiring ICD intervention. METHODS: We enrolled 46 patients with documented SAS at polysomnography (apnea/hypopnea index [AHI] > 5) who also had a left ventricle ejection fraction (LVEF) < 35% and, according to primary prevention indications, implanted an ICD (Boston Scientific Incepta) able to daily monitor apnoic/hypopnoic episodes occurring during sleep. Patients were followed at 3-month intervals. RESULTS: At a mean follow-up of 18 months, 21 episodes of sustained VT/FV requiring ICD intervention were documented in eight patients (17.4%). Baseline AHI was significantly higher in patients with compared to those without ICD intervention. ICD interventions, however, were not preceded by any worsening of apnoic/hypopnoic episodes. The respiratory disturbance index (RDI) of the week during the event, indeed, was not different from that recorded during the previous 2 weeks (25.4 ± 11, 25.6 ± 10 and 25.1 ± 10, respectively; p = .9). CONCLUSIONS: In patients with SAS who received an ICD for primary prevention of sudden death, those with ICD interventions showed a more severe form of the disease at baseline. ICD interventions, however, were not preceded by any significant changes in SAS severity.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Síndromes da Apneia do Sono/fisiopatologia , Taquicardia Ventricular/prevenção & controle , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Polissonografia , Prevenção Primária , Fatores de Risco , Índice de Gravidade de Doença , Taquicardia Ventricular/epidemiologia
5.
Medicina (Kaunas) ; 57(2)2021 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-33672601

RESUMO

The diagnosis of structural heart disease in athletes with ventricular arrhythmias (VAs) and an apparently normal heart can be very challenging. Several pieces of evidence demonstrate the importance of an extensive diagnostic work-up in apparently healthy young patients for the characterization of concealed cardiomyopathies. This study shows the various diagnostic levels and tools to help identify which athletes need deeper investigation in order to unmask possible underlying heart disease.


Assuntos
Cardiomiopatias , Cardiopatias , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Atletas , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico , Humanos , Fluxo de Trabalho
6.
Europace ; 19(3): 432-440, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27025772

RESUMO

AIMS: The number of cardiovascular implantable electronic devices has increased progressively, leading to an increased need for transvenous lead extraction (TLE) due to device infections. Previous studies described 'ghost' as a post-removal, new, tubular, mobile mass detected by echocardiography following the lead's intracardiac route in the right-sided heart chambers, associated with diagnosis of cardiac device-related infective endocarditis. We aimed to analyse the association between 'ghosts' assessed by transesophageal echocardiography (TEE) and intracardiac echocardiography (ICE) and mortality in patients undergoing TLE. METHODS AND RESULTS: We prospectively enrolled 217 patients (70 ± 13 years; 164 males) undergoing TLE for systemic infection (139), local device infection (67), and lead malfunction (11). All patients underwent TEE before and 48 h after TLE and ICE during TLE. Patients were allocated to two groups: either with (Group 1) or without (Group 2) post-procedural 'ghost'. Mid-term clinical follow-up was obtained in all patients (11 months, IQR 1-34 months). We identified 30 (14%) patients with 'ghost', after TLE. The significant predictors of 'ghost' were Charlson co-morbidity index (HR = 1.24, 95% CI 1.04-1.48, P = 0.03) and diagnosis of endocarditis assessed by ICE (HR = 1.82, 95% CI 1.01-3.29, P = 0.04). Mortality was higher in Group 1 than in Group 2 (28 vs. 5%; log-rank P < 0.001). Independent predictors of mid-term mortality were the presence of 'ghost' and systemic infection as the clinical presentation of device infection (HR = 3.47, 95% CI 1.18-10.18, P = 0.002; HR = 3.39, 95% CI 1.15-9.95, P = 0.001, respectively). CONCLUSION: The presence of 'ghost' could be an independent predictor of mortality after TLE, thus identifying a subgroup of patients who need closer clinical surveillance to promptly detect any complications.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/mortalidade , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/mortalidade , Falha de Prótese , Infecções Relacionadas à Prótese/mortalidade , Infecções Relacionadas à Prótese/cirurgia , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo/efeitos adversos , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Infecções Relacionadas à Prótese/diagnóstico , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Europace ; 18(10): 1565-1572, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26559916

RESUMO

AIMS: Aim of this study was to compare a minimally fluoroscopic radiofrequency catheter ablation with conventional fluoroscopy-guided ablation for supraventricular tachycardias (SVTs) in terms of ionizing radiation exposure for patient and operator and to estimate patients' lifetime attributable risks associated with such exposure. METHODS AND RESULTS: We performed a prospective, multicentre, randomized controlled trial in six electrophysiology (EP) laboratories in Italy. A total of 262 patients undergoing EP studies for SVT were randomized to perform a minimally fluoroscopic approach (MFA) procedure with the EnSiteTMNavXTM navigation system or a conventional approach (ConvA) procedure. The MFA was associated with a significant reduction in patients' radiation dose (0 mSv, iqr 0-0.08 vs. 8.87 mSv, iqr 3.67-22.01; P < 0.00001), total fluoroscopy time (0 s, iqr 0-12 vs. 859 s, iqr 545-1346; P < 0.00001), and operator radiation dose (1.55 vs. 25.33 µS per procedure; P < 0.001). In the MFA group, X-ray was not used at all in 72% (96/134) of cases. The acute success and complication rates were not different between the two groups (P = ns). The reduction in patients' exposure shows a 96% reduction in the estimated risks of cancer incidence and mortality and an important reduction in estimated years of life lost and years of life affected. Based on economic considerations, the benefits of MFA for patients and professionals are likely to justify its additional costs. CONCLUSION: This is the first multicentre randomized trial showing that a MFA in the ablation of SVTs dramatically reduces patients' exposure, risks of cancer incidence and mortality, and years of life affected and lost, keeping safety and efficacy. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT01132274.


Assuntos
Ablação por Cateter , Fluoroscopia/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Exposição à Radiação , Taquicardia Supraventricular/cirurgia , Adulto , Mapeamento Potencial de Superfície Corporal , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taquicardia Supraventricular/mortalidade , Resultado do Tratamento
8.
Circ J ; 80(3): 613-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26821688

RESUMO

BACKGROUND: Not all heart failure (HF) patients benefit from cardiac resynchronization therapy (CRT). We assessed whether choosing the site of left ventricular (LV) pacing by a quadripolar lead may improve response to CRT. METHODS AND RESULTS: We prospectively randomized 23 patients with HF (67±11 years; 21 males) to CRT with a quadripolar LV lead (group 1, with the LV pacing site chosen on the basis of QRS shortening using simultaneous biventricular pacing), and 20 patients (71±6 years; 16 males) to a bipolar LV lead (group 2, with devices programmed with a conventional tip-to-ring configuration). New York Heart Association (NYHA) class and LV ejection fraction (EF) by 2D echocardiography were assessed at baseline and after 3 months. The baseline EF was not different between the 2 groups (25±6% group 1 vs. 27±3% group 2; P=0.22), but after 3 months EF was higher in group 1 (35±13% group 1 vs. 31±4% group 2; P<0.001). A reduction in at least 1 NYHA class at 3 months was observed in 22 (96%) and 12 (60%) of group 1 and group 2 patients, respectively (P<0.05). CONCLUSIONS: CRT with a quadripolar LV lead was associated with an improvement of EF greater than that observed in patients receiving a bipolar LV lead. In devices with a quadripolar lead, CRT programming based on the best QRS shortening is reliable and effective. (Circ J 2016; 80: 613-618).


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Idoso , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
9.
Circulation ; 129(1): 11-7, 2014 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-24277055

RESUMO

BACKGROUND: Radiofrequency ablation of atrial fibrillation has been associated with some risk of thromboembolic events. Previous studies showed that preventive short episodes of forearm ischemia (remote ischemic preconditioning [IPC]) reduce exercise-induced platelet reactivity. In this study, we assessed whether remote IPC has any effect on platelet activation induced by radiofrequency ablation of atrial fibrillation. METHODS AND RESULTS: We randomized 19 patients (age, 54.7±11 years; 17 male) undergoing radiofrequency catheter ablation of paroxysmal atrial fibrillation to receive remote IPC or sham intermittent forearm ischemia (control subjects) before the procedure. Blood venous samples were collected before and after remote IPC/sham ischemia, at the end of the ablation procedure, and 24 hours later. Platelet activation and reactivity were assessed by flow cytometry by measuring monocyte-platelet aggregate formation, platelet CD41 in the monocyte-platelet aggregate gate, and platelet CD41 and CD62 in the platelet gate in the absence and presence of ADP stimulation. At baseline, there were no differences between groups in platelet variables. Radiofrequency ablation induced platelet activation in both groups, which persisted after 24 hours. However, compared with control subjects, remote IPC patients showed a lower increase in all platelet variables, including monocyte-platelet aggregate formation (P<0.0001), CD41 in the monocyte-platelet aggregate gate (P=0.002), and CD41 (P<0.0001) and CD62 (P=0.002) in the platelet gate. Compared with control subjects, remote IPC was also associated with a significantly lower ADP-induced increase in all platelet markers. CONCLUSIONS: Our data show that remote IPC before radiofrequency catheter ablation for paroxysmal atrial fibrillation significantly reduces the increased platelet activation and reactivity associated with the procedure.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Precondicionamento Isquêmico Miocárdico/métodos , Isquemia Miocárdica/prevenção & controle , Ativação Plaquetária/fisiologia , Complicações Pós-Operatórias/prevenção & controle , Adulto , Idoso , Fibrilação Atrial/sangue , Plaquetas/fisiologia , Feminino , Antebraço/irrigação sanguínea , Humanos , Masculino , Pessoa de Meia-Idade , Monócitos/fisiologia , Complicações Pós-Operatórias/sangue , Trombose/sangue , Trombose/prevenção & controle
10.
J Cardiovasc Electrophysiol ; 25(12): 1363-7, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25066621

RESUMO

BACKGROUND: Patients with severe structural heart disease have increased mortality after implantable cardioverter-defibrillator (ICD) shocks. Whether this is limited to ICD shock therapy only or extends also to no-shock therapies, such as antitachycardia pacing (ATP), is unclear. We investigated the impact of different ICD therapies on long-term mortality. METHODS: We enrolled 573 patients who underwent ICD implantation at our institution from 2004 to 2011. The population was divided into 3 groups: no device interventions (group 1), ATP interventions (group 2), and shock interventions (group 3). The endpoint was the all-cause mortality. RESULTS: Over a follow-up period of 48 months (range 1-110), 447 (78%) had no device interventions, 71 (12%) had ATP therapy only, and 55 (10%) had at least one shock intervention. All-cause mortality occurred in 94 patients in group 1 (21%), 23 patients (43%) in group 2, and 21 patients (38%) in group 3. At multivariable Cox regression analysis, ATP intervention (HR: 1.8; 95% CI 1.1-3; P < 0.001), shock intervention (HR: 1.39; 95% CI 1.09-1.77; P = 0.008), age (HR: 1.05; 95% CI 1.02-1.07; P < 0.001), and LVEF (HR: 0.95; 95% CI 0.93-0.98; P = 0.001) were predictors of all-cause mortality. No significant difference in mortality was found between group 2 and 3. CONCLUSION: Patients with ICDs who receive appropriate interventions are at increased risk of mortality. Such risk is not dependent on different types of ICD therapy, such as shocks or ATP. Our data suggest that sustained ventricular arrhythmias per se have a negative impact on prognosis rather than modality of ICD therapy.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/mortalidade , Insuficiência Cardíaca/mortalidade , Taquicardia Ventricular/prevenção & controle , Idoso , Comorbidade , Cardioversão Elétrica/instrumentação , Feminino , Insuficiência Cardíaca/prevenção & controle , Humanos , Incidência , Itália/epidemiologia , Masculino , Estudos Retrospectivos , Medição de Risco , Taxa de Sobrevida , Taquicardia Ventricular/mortalidade , Resultado do Tratamento
11.
J Nucl Cardiol ; 21(3): 622-32, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24715624

RESUMO

BACKGROUND: Positron emission tomography-computed tomography (PET-CT) with (18)F-fluorodeoxyglucose (FDG) has emerged as a rapidly evolving diagnostic tool for infectious diseases. However, the optimal imaging time in this clinical setting is not clear yet. The aim of this study is to investigate whether delayed (3 hours) FDG PET-CT could increase the diagnostic accuracy of this technique compared to standard (1 hour) imaging in the detection of septic foci involving the pocket and/or pacing leads in patients with suspected cardiovascular implantable electronic device (CIED) infection scheduled for device removal. METHODS AND RESULTS: Twenty-seven patients underwent standard and delayed imaging. PET-CT results were compared to bacteriological cultures after CIED removal. Fifteen controls free of infection underwent PET-CT imaging as part of investigation of malignancy. The diagnostic accuracy of delayed imaging was significantly higher than 1-hour scan for lead infection (70% vs 51%, P = .024). No significant difference was found between standard and delayed diagnostic accuracy for pocket or device infection. Semi-quantitative analysis showed that mean pocket and lead target-to-background ratio were significantly higher on delayed compared to standard imaging (3.7 ± 1.9 vs 1.6 ± 1.1, P = .0002; 3.0 ± 1.3 vs 0.7 ± 1.0, P = .01). CONCLUSIONS: Delayed FDG PET-CT imaging should be considered at least in patients with negative 1-hour scan and founded suspicion of pacing lead infection.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Endocardite/diagnóstico por imagem , Fluordesoxiglucose F18 , Marca-Passo Artificial/efeitos adversos , Tomografia por Emissão de Pósitrons/métodos , Infecções Relacionadas à Prótese/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Endocardite/etiologia , Feminino , Humanos , Masculino , Imagem Multimodal/métodos , Infecções Relacionadas à Prótese/etiologia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo
13.
Europace ; 16(10): 1496-507, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24965015

RESUMO

BACKGROUND: Transvenous lead extraction (TLE) is a complex invasive procedure and the experience of the operator and the team is a major determinant of procedural outcomes. AIM: Because of very limited data available on minimum procedural volumes to enable training and ongoing competency for TLEs, we performed a meta-analysis aimed at assessing the outcomes of TLE in the centres with low, medium, and high volume of procedures. METHODS: Of the 280 papers initially retrieved until February 2013, 66 observational studies met inclusion criteria and were included in at least one stratified meta-analysis: 17 were prospective studies; 47 had a retrospective design; and 2 were defined 'experience studies'. We included only articles published after the introduction of laser technique (year 1999). We divided the studies in low, medium, and high volume centres utilizing either the European Heart Rhythm Association (EHRA) or Lexicon classification criteria. RESULTS: When meta-analyses were carried out separately for the studies with larger and smaller sample sizes, either using EHRA or Lexicon classification criteria, no clear differences emerged in the combined rate of major complications or intraoperative deaths. In contrast, both minor complications and mortality at 30 days decreased as centre volume increased. CONCLUSIONS: In our meta-analysis of observational studies, patients who have been treated in higher volume centres have a lower probability of minor complications and death at 30 days regardless of the infection rate, length of lead duration, type of device, and type of extraction.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo/métodos , Marca-Passo Artificial/efeitos adversos , Segurança do Paciente , Veias , Humanos , Falha de Prótese , Infecções Relacionadas à Prótese/etiologia
14.
BMJ Case Rep ; 17(3)2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38508603

RESUMO

Remote monitoring (RM) of cardiac implantable electronic devices (CIED) represented a major improvement in clinical practice and has been used with multiple indications. Many parameters monitored on a daily basis by current CIED can indeed assist in clinical practice (eg, decompensated heart failure) by providing the patient with optimal timing for anticipated outpatient visit or urgent medical care. Recognition of acute myocardial infarction (AMI) is not usually considered among the capabilities of RM. We present the case of an AMI occurring without any ischaemic symptoms but associated with recurrent ventricular tachyarrhythmias effectively treated by multiple interventions of the implantable cardioverter defibrillator and promptly detected by RM personnel, who recommended the patient to quickly access to the emergency department where diagnosis and revascularization of an otherwise untreated myocardial infarction was performed.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Infarto do Miocárdio , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Insuficiência Cardíaca/diagnóstico , Coração
15.
Europace ; 15(11): 1615-21, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23794613

RESUMO

AIMS: A wide QRS with left bundle branch block pattern is usually required for cardiac resynchronization therapy (CRT) in patients with dilated cardiomyopathy. However, ∼30% of patients do not benefit from CRT. We evaluated whether a detailed analysis of QRS complex can improve prediction of CRT success. METHODS AND RESULTS: We studied 51 patients (67.3 + 9.5 years, 36 males) with classical indication to CRT. Twelve-lead electrocardiogram (ECG) (50 mm/s, 0.05 mV/mm) was obtained before and 3 months after CRT. The following ECG intervals were measured in leads V1 and V6: (i) total QRS duration; (ii) QRS onset-R wave peak; (iii) R wave peak-S wave peak (RS-V1 and RS-V6); (iv) S wave peak-QRS end; and (v) difference between QR in V6 and in V1. Patients were considered as responder when left ventricular ejection fraction (LVEF) increased by ≥5% and New York Heart Association class by ≥1 after 3 months of CRT. Of ECG intervals, only basal RS-V1 was longer in responders (n = 36) compared with non-responders (52.9 ± 11.8 vs. 44.0 ± 12.6 ms, P = 0.021). Among patients with RS-V1 ≥45 ms 83% responded to CRT vs. 33% of those with RS-V1 < 45 ms (P < 0.001). RS-V1 ≥ 45 ms was independently associated with response to CRT in multivariable analysis (odds ratio 9.8; P = 0.002). A reduction of RS-V1 ≥ 10 ms by CRT also significantly predicted clinical response. RS-V1 shortening correlated with improvement in LVEF (r = -0.45; P < 0.001) and in MS (r = 0.46; P < 0.001). CONCLUSION: Our data point out that RS-V1 interval and its changes with CRT may help to identify patients who are most likely to benefit from CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatia Dilatada/fisiopatologia , Cardiomiopatia Dilatada/terapia , Eletrocardiografia/métodos , Idoso , Bloqueio de Ramo/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
16.
Rev Esp Cardiol (Engl Ed) ; 76(5): 353-361, 2023 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36493957

RESUMO

INTRODUCTION AND OBJECTIVES: The clinical value of electrocardiogram (ECG) repolarization parameters associated with ventricular arrhythmias (VAs) in tako-tsubo syndrome is still under debate. We aimed to evaluate ECG predictors of subacute VAs, defined as those occurring after the first 48hours from admission. METHODS: This single-center observational study enrolled patients admitted to the cardiology department between 2012 and 2018 with a confirmed diagnosis of tako-tsubo syndrome. Data collection included a 12-lead ECG on admission and at 48hours, continuous telemetry monitoring, blood testing, transthoracic echocardiography, and coronary angiography during hospitalization. VAs events were defined as: premature ventricular contractions ≥ 2000 within a 24-hour window of telemetry monitoring, ventricular fibrillation, sustained ventricular tachycardia (VT), polymorphic VT, and non-sustained VT. RESULTS: A total of 87 patients (age 72±12 years) were enrolled. During a median of 8 days of hospitalization, subacute VAs were documented in 22 patients (25%) after a median of 91hours from admission. Subacute VAs were associated with an increase in mortality during hospitalization (P=.030). The corrected global (mean of the 12-lead ECG values) Tpeak-Tend interval at 48hours from admission was an independent predictor of subacute VAs and was statistically superior to the standard corrected QT interval (Z test, P=.040). A cut-off of 108 msec for the corrected global Tpeak-Tend yielded a 71% sensitivity and 72% specificity for subacute VAs. CONCLUSIONS: In patients with tako-tsubo syndrome, subacute VAs are associated with repolarization alterations that can be identified on conventional ECG using the Tpeak-Tend interval.


Assuntos
Taquicardia Ventricular , Cardiomiopatia de Takotsubo , Complexos Ventriculares Prematuros , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Cardiomiopatia de Takotsubo/complicações , Cardiomiopatia de Takotsubo/diagnóstico , Prognóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Eletrocardiografia , Hospitais
17.
J Cardiovasc Dev Dis ; 10(4)2023 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-37103047

RESUMO

BACKGROUND: Adults with congenital heart disease (ACHD) are often affected by cardiac arrhythmias requiring catheter ablation. Catheter ablation in this setting represents the treatment of choice but is flawed by frequent recurrencies. Predictors of arrhythmia relapse have been identified, but the role of cardiac fibrosis in this setting has not been investigated. The aim of this study was to determine the role of the extension of cardiac fibrosis, detected by electroanatomical mapping, in predicting arrhythmia recurrencies after ablation in ACHD. MATERIALS AND METHODS: Consecutive patients with congenital heart disease and atrial or ventricular arrhythmias undergoing catheter ablation were enrolled. An electroanatomical bipolar voltage map was performed during sinus rhythm in each patient and bipolar scar was assessed according to the current literature data. During follow-up, arrhythmia recurrences were recorded. The relationship between the extent of myocardial fibrosis and arrhythmia recurrence was assessed. RESULTS: Twenty patients underwent successful catheter ablation of atrial (14) or ventricular (6) arrhythmias, with no inducible arrhythmia at the end of the procedure. During a median follow-up period of 207 weeks (IQR 80 weeks), eight patients (40%; five atrial and three ventricular arrhythmias) had arrhythmia recurrence. Of the five patients undergoing a second ablation, four showed a new reentrant circuit, while one patient had a conduction gap across a previous ablation line. The extension of the bipolar scar area (HR 1.049, CI 1.011-1.089, p = 0.011) and the presence of a bipolar scar area >20 cm2 (HR 6.101, CI 1.147-32.442, p = 0.034) were identified as predictors of arrhythmia relapse. CONCLUSION: The extension of the bipolar scar area and the presence of a bipolar scar area >20 cm2 can predict arrhythmia relapse in ACHD undergoing catheter ablation of atrial and ventricular arrhythmias. Recurrent arrhythmias are often caused by circuits other than those previously ablated.

18.
Future Cardiol ; 19(14): 707-718, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37929680

RESUMO

Recently, prognosis and survival of cancer patients has improved due to progression and refinement of cancer therapies; however, cardiovascular sequelae in this population augmented and now represent the second cause of death in oncological patients. Initially, the main issue was represented by heart failure and coronary artery disease, but a growing body of evidence has now shed light on the increased arrhythmic risk of this population, atrial fibrillation being the most frequently encountered. Awareness of arrhythmic complications of cancer and its treatments may help oncologists and cardiologists to develop targeted approaches for the management of arrhythmias in this population. In this review, we provide an updated overview of the mechanisms triggering cardiac arrhythmias in cancer patients, their prevalence and management.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Neoplasias , Humanos , Prevalência , Fibrilação Atrial/complicações , Neoplasias/complicações , Neoplasias/epidemiologia , Neoplasias/terapia , Insuficiência Cardíaca/complicações
19.
JACC Clin Electrophysiol ; 9(3): 314-326, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36752480

RESUMO

BACKGROUND: Endomyocardial biopsy (EMB) is required to make a definite diagnosis of lymphocytic myocarditis (LM), to identify its etiology, and to classify LM into different phases. OBJECTIVES: This study aims to characterize and compare clinical and electrophysiological characteristics of different biopsy-proven LM phases, namely acute myocarditis (AM), chronic active myocarditis (CAM), and healed myocarditis (HM). METHODS: All patients with a diagnosis of LM at 3 Italian referral centers were prospectively enrolled. According to EMB findings, LM was classified as AM, CAM, or HM; per-group comparisons of clinical presentations, noninvasive, and invasive findings are reported. RESULTS: Among the 122 enrolled patients (AM, n = 44; CAM, n = 42; HM, n = 36), complex ventricular arrhythmias were very common overall (n = 109, 89%), but ventricular fibrillation was slightly more prevalent in AM (P = 0.028). Cardiac magnetic resonance imaging showed late gadolinium enhancement in more patients with HM and CAM than AM (94.4% vs 92.9% vs 50%; P < 0.001), whereas edema was more common in AM than in CAM, being absent in HM (90.9% vs 50% vs 0%; P < 0.001). Accordingly, edema was the strongest independent clinical predictor of EMB-proven active inflammation. Electroanatomical mapping revealed a lower prevalence of low-voltage areas in AM than in CAM or HM. We observed a strong association between edema at a specific myocardial segment and normal voltages at that site (odds ratio: 0.24; 95% CI: 0.10-0.54; P < 0.01), as well as between late gadolinium enhancement and low-voltage areas (odds ratio: 2.86; 95% CI: 1.19-6.97; P = 0.019). CONCLUSIONS: LM is a highly heterogeneous disease, and its different phases are characterized by diverse clinical, morphological, and electrophysiological features. Further research is required to identify electroanatomical markers of inflammation.


Assuntos
Miocardite , Humanos , Miocardite/complicações , Miocardite/diagnóstico , Meios de Contraste , Gadolínio , Miocárdio/patologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/etiologia , Inflamação
20.
Front Cardiovasc Med ; 10: 1020966, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36923954

RESUMO

Introduction: Monomorphic ventricular tachycardia (VT) is a life-threatening condition often observed in patients with structural heart disease. Ventricular tachycardia ablation through radiation therapy (VT-ART) for sustained monomorphic ventricular tachycardia seems promising, effective, and safe. VT-ART delivers focused, high-dose radiation, usually in a single fraction of 25 Gy, allowing ablation of VT by inducing myocardial scars. The procedure is fully non-invasive; therefore, it can be easily performed in patients with contraindications to invasive ablation procedures. Definitive data are lacking, and no direct comparison with standard procedures is available. Discussion: The aim of this multicenter observational study is to evaluate the efficacy and safety of VT-ART, comparing the clinical outcome of patients undergone to VT-ART to patients not having received such a procedure. The two groups will not be collected by direct, prospective accrual to avoid randomization among the innovative and traditional arm: A retrospective selection through matched pair analysis will collect patients presenting features similar to the ones undergone VT-ART within the consortium (in each center independently). Our trial will enroll patients with optimized medical therapy in whom endocardial and/or epicardial radiofrequency ablation (RFA), the gold standard for VT ablation, is either unfeasible or fails to control VT recurrence. Our primary outcome is investigating the difference in overall cardiovascular survival among the group undergoing VT-ART and the one not exposed to the innovative procedure. The secondary outcome is evaluating the difference in ventricular event-free survival after the last procedure (i.e., last RFA vs. VT-ART) between the two groups. An additional secondary aim is to evaluate the reduction in the number of VT episodes comparing the 3 months before the procedure to the ones recorded at 6 months (from the 4th to 6th month) following VT-ART and RFA, respectively. Other secondary objectives include identifying the benefits of VT-ART on cardiac function, as evaluated through an electrocardiogram, echocardiographic, biochemical variables, and on patient quality of life. We calculated the sample size (in a 2:1 ratio) upon enrolling 149 patients: 100 in the non-exposed control group and 49 in the VT-ART group. Progressively, on a multicentric basis supervised by the promoting center in the VT-ART consortium, for each VT-ART patient enrollment, a matched pair patient profile according to the predefined features will be shared with the consortium to enroll a patient that has not undergone VT-ART. Conclusion: Our trial will provide insight into the efficacy and safety of VT-ART through a matched pair analysis, via an observational, multicentric study of two groups of patients with or without VT-ART in the multicentric consortium (with subgroup stratification into dynamic cohorts).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA