Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Acta Oncol ; 62(11): 1455-1460, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37773941

RESUMO

BACKGROUND: Inter-fractional anatomical changes challenge robust delivery of whole-pelvic proton therapy for high-risk prostate cancer. Pre-treatment robust evaluation (PRE) takes uncertainties in isocenter shifts and distal beam edge in treatment plans into account. Using weekly control computed tomography scans (cCTs), the aim of this study was to evaluate the PRE strategy by comparing to an off-line during-treatment robust evaluation (DRE) while also assessing plan robustness with respect to protocol planning constraints. MATERIAL AND METHODS: Treatment plans and cCTs from ten patients included in the pilot phase of the PROstate PROTON Trial 1 were analysed. Treatment planning followed protocol guidelines with 78 Gy to the primary clinical target volume (CTVp) and 56 Gy to the elective target (CTVe) in 39 fractions. Recalculations of the treatment plans were performed for a total of 64 cCTs and dose/volume measures corresponding to clinical constraints were evaluated for this DRE against the simulated scenario interval from the PRE. RESULTS: Of the 64 cCTs, 59 showed DRE CTVp measures within the robustness range from the PRE; this was also the case for 39 of the cCTs for the CTVe measures. However, DRE CTVe coverage was still within constraints for 57 of the 64 cCTs. DRE dose/volume measures for CTVp fulfilled target coverage constraints in 59 of 64 cCTs. All DRE measures for the rectum, bladder, and bowel were inside the PRE range in 63, 39, and 31 cCTs, respectively. CONCLUSION: The PRE strategy predicted the DRE scenarios for CTVp and rectum. CTVe, bladder, and bowel showed more complex anatomical variations than simulated by the PRE isocenter shift. Both original and recalculated nominal treatment plans showed robust treatment delivery in terms of target coverage.


Assuntos
Neoplasias da Próstata , Terapia com Prótons , Radioterapia de Intensidade Modulada , Masculino , Humanos , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Órgãos em Risco , Dosagem Radioterapêutica
2.
Acta Oncol ; 62(10): 1279-1285, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37647364

RESUMO

BACKGROUND: Secondary lymphedema is a known side effect to radiotherapy (RT), but limited information regarding prevalence and risk factors for lower limb edema (LLE) after curative radiotherapy in patients with prostate cancer (PCa) is available. This study provides a descriptive analysis of patient-reported LLE with analysis of risk factors in a cohort of patients with PCa treated with curative RT. MATERIAL AND METHODS: A total of 302 patients with PCa with prospective registration of patient-reported LLE (EORTC QLQ-PR25 (Question 46)) were included. Analysis of LLE was done with the calculation of prevalence rates and Kaplan-Meier statistics. Risk factors for LLE were analyzed multivariate with Cox regression analysis. RESULTS: At a median follow-up of 15 (3-51) months, the overall crude incidence of patients reporting 'quite a bit' or 'a lot' of LLE was 49 (16.2%) and 21 (7.0%), respectively. The baseline prevalence rate of 'quite a bit' and 'a lot' of LLE was 5.0% and 0.8%, respectively. During follow-up the prevalence rate for 'quite a bit' or 'a lot' of LLE increased significantly and remained constant from 6 months where 11.5% (±1.7%) reported 'quite a bit' and 2.9% (±0.5%) reported 'very much' LLE (p < 0.001), respectively.Significant risk factors (p < 0.10) for LLE in univariate analysis included lymph node irradiation (HR:2.325), baseline Body Mass Index (BMI) (HR:1.100), Charlson Comorbidity Index (HR:1.227), Androgen Deprivation Therapy (HR:2,979), and Performance Status (HR:0.594). Only high BMI (HR:1.091) remained significant in multivariate analysis with a three-fold increase in LLE in patients with BMI ≥ 30 compared to normal weight patients. CONCLUSION: Severe patient-reported LLE after curative RT for PCa is rare. Significantly more patients with a high BMI report 'quite a bit' or 'very much' LLE compared to patients with a normal BMI. Obese PCa patients could be offered a rehabilitation program for early detection and management of LLE.


Assuntos
Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/radioterapia , Estudos Prospectivos , Antagonistas de Androgênios , Edema , Extremidade Inferior , Medidas de Resultados Relatados pelo Paciente
3.
Acta Oncol ; 61(2): 179-184, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34543143

RESUMO

BACKGROUND: The aim of this study was to assess acute and late morbidity measured by the physician and patient-reported outcomes (PROs) in high-risk prostate cancer (PC) patients receiving whole pelvic intensity-modulated radiotherapy (IMRT) in the setting of a national clinical trial. MATERIAL AND METHODS: A total of 88 patients with adenocarcinoma of the prostate and high-risk parameters were enrolled from 2011 to 2013. All patients received 78 Gy in 39 fractions of IMRT delivering simultaneous 78 Gy to the prostate and 56 Gy to the seminal vesicles and lymph nodes. Physician-reported morbidity was assessed by CTCAE v.4.0. PROs were registered for gastro-intestinal (GI) by the RT-ARD score, genito-urinary (GU) by DAN-PSS, sexual and hormonal by EPIC-26, and quality of life (QoL) by EORTC QLQ-C30. RESULTS: Median follow-up (FU) time was 4.6 years. No persistent late CTCAE grade 3+ morbidity was observed. Prevalence of CTCAE grade 2+ GI morbidities varied from 0 to 6% at baseline throughout FU time, except for diarrhea, which was reported in 19% of the patients post-RT. PROs revealed increased GI morbidity (≥1 monthly episode) for "rectal urgency", "use of pads", "incomplete evacuation", "mucus in stool" and "bowel function impact on QoL" all remained significantly different (p < .05) at 60 months compared to baseline. CTCAE grade 2+ GU and sexual morbidity were unchanged. GU PROs on obstructive and irritative GU items (≥daily episode) increased during RT and normalized at 24 months. No clinically significant differences were found in sexual, hormonal, and QoL scores compared to baseline. CONCLUSIONS: Whole pelvic RT resulted in a mild to the moderate burden of late GI morbidities demonstrated by a relatively high prevalence of PROs. Whereas, physician-assessed morbidity revealed a low prevalence of late GI morbidity scores. This emphasizes the importance of using both PROs and physician-reported scoring scales when reporting late morbidity in clinical trials.


Assuntos
Médicos , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Humanos , Masculino , Morbidade , Medidas de Resultados Relatados pelo Paciente , Neoplasias da Próstata/epidemiologia , Neoplasias da Próstata/radioterapia , Qualidade de Vida , Radioterapia de Intensidade Modulada/efeitos adversos
4.
Acta Oncol ; 60(5): 598-604, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33646069

RESUMO

BACKGROUND: Proton therapy (PT) is sensitive towards anatomical changes that may occur during a treatment course. The aim of this study was to investigate if anatomically robust PT (ARPT) plans incorporating patient-specific target motion improved target coverage while still sparing normal tissues, when applied on locally advanced prostate cancer patients where pelvic irradiation is indicated. MATERIAL AND METHODS: A planning computed tomography (CT) scan used for dose calculation and two additional CTs (acquired on different days) were used to make patient-specific targets for the ARPT plans on the eight included patients. The plans were compared to a conventional robust PT plan and a volumetric modulated arc therapy (VMAT) photon plan, which were derived from the planning CT (pCT). Worst-case robust optimisation was used for all proton plans with a setup uncertainty of 5 mm and a range uncertainty of 3.5%. Target coverage (V95% and D95%) and normal tissue doses (V5-75 Gy) were evaluated on 6-8 rCTs per patient. RESULTS: The ARPT plans improved the prostate target coverage for the most challenging patient compared to conventional robust PT plans (20% point increase for V95% and 31 Gy increase for D95%). Across the whole cohort the estimated mean value for V95% was 97% for the ARPT plans and 95% for the conventional robust PT plans. The ARPT plans had a slight, statistically insignificant increase in normal tissue doses compared to the conventional robust proton plans. Compared to VMAT, the ARPT plans significantly reduced the normal tissue doses in the low-to-intermediate dose range. CONCLUSIONS: While both proton plans reduced the low-to-intermediate normal tissue doses compared to VMAT, ARPT plans improved the target coverage for the most challenging patient without significantly increasing the normal tissue doses compared to conventional robust PT plans.


Assuntos
Neoplasias da Próstata , Terapia com Prótons , Radioterapia de Intensidade Modulada , Humanos , Masculino , Órgãos em Risco , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X
5.
J Magn Reson Imaging ; 51(4): 1235-1246, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31588646

RESUMO

BACKGROUND: Previous studies have reported tumor volume underestimation with multiparametric (mp)MRI in prostate cancer diagnosis. PURPOSE: To investigate why some parts of lesions are not visible on mpMRI by comparing their histopathology features to those of visible regions. STUDY TYPE: Retrospective. POPULATION: Thirty-four patients with biopsy-proven prostate cancer scheduled for prostatectomy (median 68.7 years). FIELD STRENGTH/SEQUENCE: T2 -weighted, diffusion-weighted imaging, T2 mapping, and dynamic contrast-enhanced MRI on two 3T systems and one 1.5T system. ASSESSMENT: Two readers delineated suspicious lesions on mpMRI. A pathologist delineated the lesions on histopathology. A patient-customized mold enabled the registration of histopathology and MRI. On histopathology we identified mpMRI visible and invisible lesions. Subsequently, within the visible lesions we identified regions that were visible and regions that were invisible on mpMRI. For each lesion and region the following characteristics were determined: size, location, International Society of Urological Pathology (ISUP) grade, and Gleason subpatterns (density [dense/intermediate], tumor morphology [homogeneous/heterogeneous], cribriform growth [yes/no]). STATISTICAL TESTS: With generalized linear mixed-effect modeling we investigated which features explain why a lesion or a region was invisible on MRI. We compared imaging values (T2 , ADC, and Ktrans ) for these features with one-way analysis of variance (ANOVA). RESULTS: Small, anterior, and ISUP grade 1-2 lesions (n = 34) were missed more frequent than large, posterior, ISUP grade ≥ 3 lesions (n = 35). Invisible regions on mpMRI had lower tumor density, heterogeneous tumor morphology, and were located in the transition zone. Both T2 and ADC values were higher in "intermediate" compared with "dense" regions (P = 0.002 and < 0.001) and in regions with heterogeneous compared with homogeneous morphology (P < 0.001 and 0.03). Ktrans was not significantly different (P = 0.24 and 0.99). DATA CONCLUSION: Regions of prostate cancer lesions that are invisible on mpMRI have different histopathology features than visible regions. This may have implications for monitoring during active surveillance and focal treatment strategies. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2020;51:1235-1246.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Humanos , Imageamento por Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos
6.
Acta Oncol ; 56(6): 839-845, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28464733

RESUMO

BACKGROUND: Proton therapy (PT) may have a normal tissue sparing potential when co-irradiating pelvic lymph nodes in patients with locally advanced prostate cancer, but may also be more sensitive towards organ motion in the pelvis. Building upon a previous study identifying motion-robust proton beam angles for pelvic irradiation, we aimed to evaluate the influence of organ motion for PT using biological models, and to compare this with contemporary photon-based RT. MATERIAL AND METHODS: Eight locally advanced prostate cancer patients with a planning CT (pCT) and 8-9 repeated CT scans (rCTs) were included. Two PT plans were created, one using two lateral opposed beams at gantry angles of 90°/270° and the other using two lateral oblique beams at 35°/325°; these were compared with volumetric modulated arc therapy (VMAT) plans. All plans were optimised on the pCT and subsequently re-calculated on each rCT (following rigid alignment on the prostate). Dose distributions in organs at risk (OARs) were evaluated using mean dose, generalized equivalent uniform doses (gEUDs) and normal tissue complication probabilities (NTCPs), while mean dose and the volume receiving 98% of the dose (V98%) were used for the targets. RESULTS: PT significantly reduced the mean dose to the OARs and a correlation was seen in the pCTs between the prostate PTV overlapping the relevant OAR and OAR NTCPs, as was also the case for the VMAT plans. The best prostate target coverage across the rCTs for the IMPT plans were seen with two lateral opposed beams, although a poor coverage of the lymph node target was apparent based on V98% compared to the VMAT plans. CONCLUSIONS: PT reduced the mean dose to normal tissues in the irradiation of pelvic lymph nodes and a strong association between the volume overlap and NTCPs in the pCTs were found.


Assuntos
Modelos Biológicos , Movimentos dos Órgãos/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Fótons , Neoplasias da Próstata/radioterapia , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino , Pelve/efeitos da radiação , Dosagem Radioterapêutica , Reto/efeitos da radiação
7.
Acta Oncol ; 56(6): 846-852, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28464734

RESUMO

BACKGROUND: Proton therapy dose distributions are sensitive to range variations, e.g. arising from inter-fraction organ motion. The aim of this study was to evaluate the inter-fraction motion robustness of proton beams from different beam angles in irradiation of pelvic lymph nodes (LNs). MATERIAL AND METHODS: Planning CT (pCT) and multiple repeat CT (rCT) scans of 18 prostate cancer patients were used. Considering left and right LNs separately, the average water equivalent path length (WEPL) over all ray paths in the beams eye view of the LNs were calculated for all gantry/couch angle combinations across all rCTs versus the corresponding pCT. Single beam proton plans were optimized on the pCT for all gantry angles (0° couch) and were re-calculated on all rCTs for each respective patient. WEPL and dose parameters were extracted and a statistical clustering analysis performed to identify patient sub-populations in terms of patterns in which angles were robust. RESULTS: The WEPL analysis showed a general pattern of least variation for 0° couch beam angles where three minima were found across gantry angles for the left LNs and two for the right LNs. The clustering analysis identified three patient sub-groups for the left LNs and two groups for the right LNs. The dose calculations showed similar results as the WEPL variation, e.g. for the left LNs angles around 25°-35°, 100°-110°, and 160°-170° were consistently preferable for both target and organs at risk. CONCLUSIONS: Sub-populations of patients with similar patterns of WEPL variations across beam angles were identified. The most robust angles found for WEPL variations were also confirmed by the dose/volume analysis.


Assuntos
Linfonodos/efeitos da radiação , Movimento/efeitos da radiação , Neoplasias Pélvicas/radioterapia , Neoplasias da Próstata/radioterapia , Terapia com Prótons , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos de Coortes , Humanos , Processamento de Imagem Assistida por Computador/métodos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Masculino , Órgãos em Risco/efeitos da radiação , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos
8.
Acta Oncol ; 56(11): 1514-1521, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28844157

RESUMO

INTRODUCTION: Normal tissue morbidity sets the dose limit for radiotherapy (RT) in cancer treatment and has importance for quality of life for cancer survivors. A previous study of prostate cancer patients treated with RT generated clinical data for radiation-induced morbidity measured by anorectal physiological methods and validated questionnaires. Other studies have identified genetic predictors associated with late radiation-induced morbidity outcome. We have expanded biobank material aiming to validate single nucleotide polymorphisms (SNPs) and a gene expression classifier with endpoints on patient-reported outcomes and biomechanical properties of the anorectum from our cohort matching originally published endpoints. MATERIALS AND METHODS: The present cohort of prostate cancer patients was treated with RT curative intent in 1999-2007. Nine SNPs associated with late radiation-induced morbidity were tested in 96 patients (rs2788612, rs1800629, rs264663, rs2682585, rs2268363, rs1801516, rs13035033, rs7120482 and rs17779457). A validated gene expression profile predictive of resistance to radiation-induced skin fibrosis was tested in 42 patients. An RT-induced anorectal dysfunction score (RT-ARD) served as a fibrosis-surrogate and a measure of overall radiation-induced morbidity. RESULTS: The lowest p-value found in the genotype analyses was for SNP rs2682585 minor allele (A) in the FSHR gene and the RT-ARD score with odds ratios (OR) = 1.76; 95% CI (0.98-3.17) p = .06, which was out of concordance with original data showing a protective effect of the minor allele. The gene expression profile in patients classified as fibrosis-resistant was associated with high RT-ARD scores OR 4.18; 95% CI (1.1-16.6), p = .04 conflicting with the hypothesis that fibrosis-resistant patients would experience lower RT-ARD scores. CONCLUSIONS: We aimed to validate nine SNPs and a gene expression classifier in a cohort of prostate cancer patients with unique scoring of radiation-induced morbidity. One significant association was found, pointing to the opposite direction of originally published data. We conclude that the material was not able to validate previously published genetic predictors of radiation-induced morbidity.


Assuntos
Biomarcadores Tumorais/genética , Recidiva Local de Neoplasia/radioterapia , Polimorfismo de Nucleotídeo Único , Neoplasias da Próstata/radioterapia , Lesões por Radiação/diagnóstico , Radioterapia/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Predisposição Genética para Doença , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade , Recidiva Local de Neoplasia/genética , Neoplasias da Próstata/genética , Qualidade de Vida , Lesões por Radiação/etiologia , Transcriptoma
9.
Acta Oncol ; 54(9): 1393-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26340044

RESUMO

INTRODUCTION: Hypoxic tumor cells are radioresistant, therefore, identification of hypoxia is crucial. Hyperpolarized magnetic resonance spectroscopy (HPMRS) allows real time measurements of the conversion of pyruvate to lactate, the final step of anaerobic energy production, and may thus allow non-invasive identification of hypoxia or treatment-induced changes in oxygenation. The aim of the study was to investigate the usefulness of HPMRS as a means to assess tumor hypoxia and its dynamics during intervention. MATERIAL AND METHODS: C3H mammary carcinomas grown in CDF1 mice were used. To manipulate with tumor oxygenation, non-anaesthetized mice were gassed with air, 10% or 100% oxygen prior to administration of hyperpolarized [1-¹³C]pyruvate and HPMRS analysis. A direct assessment of tumor oxygen partial pressure (pO2) distributions were made using the Eppendorf oxygen electrode in a separate, but similarly treated, group of mice. RESULTS: Even though breathing 100% oxygen improved tumor oxygenation as evidenced by pO2 measurements, the mean (with 1 S.E.) [1-¹³C]lactate/[1-¹³C]pyruvate ratio was unaffected by this intervention, being 34 (30-37) in mice breathing air and 37 (33-42) in mice breathing 100% oxygen. In contrast, and in accordance with pO2 measurements, a significant increase in the [1-¹³C]lactate/[1-¹³C]pyruvate ratio was seen in 10% oxygen-breathing mice with a ratio of 46 (42-50). CONCLUSIONS: Although, no metabolic change was observed during 100% O2 breathing using HPMRS, the significant increase in the [1-¹³C]lactate/[1-¹³C]pyruvate ratio during 10% oxygen breathing suggests, that HPMRS can detect hypoxia-driven changes in the metabolic fate of pyruvate. To what extent and for what purposes HPMRS may best supplement or complement established techniques like hypoxia PET needs to be unraveled in future research.


Assuntos
Hipóxia Celular , Espectroscopia de Ressonância Magnética/métodos , Neoplasias Mamárias Experimentais/metabolismo , Oxigênio/metabolismo , Administração por Inalação , Animais , Feminino , Ácido Láctico/sangue , Camundongos Endogâmicos C3H , Oxigênio/administração & dosagem , Ácido Pirúvico/sangue
10.
Acta Oncol ; 54(9): 1643-50, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26203931

RESUMO

BACKGROUND: The benefit of proton therapy may be jeopardized by dose deterioration caused by water equivalent path length (WEPL) variations. In this study we introduced a method to evaluate robustness of proton therapy with respect to inter-fractional motion and applied it to irradiation of the pelvic lymph nodes (LNs) from different beam angles. Patient- versus population-specific patterns in dose deterioration were explored. MATERIAL AND METHODS: Patient data sets consisting of a planning computed tomography (pCT) as well as multiple repeat CT (rCT) scans for three patients were used, with target volumes and organs at risk (ORs) outlined in all scans. Single beam spot scanning proton plans were optimized for the left and right LN targets separately, across all possible beam angle configurations (5° angle intervals). Isotropic margins of 0, 3, 5 and 7 mm from the clinical target volume (CTV) to the planning target volume (PTV) were investigated. The optimized fluence maps for the pCT for each beam were applied onto all rCTs and the dose distributions were re-calculated. WEPL variation for each beam angle was computed by averaging over beams eye view WEPL distributions. RESULTS: Similarity in deterioration patterns were found for the investigated patients, with beam angles delivering less dose to rectum, bladder and overall normal tissue identified around 40° and around 150°-160° for the left LNs, and corresponding angles for the right LNs. These angles were also associated with low values of WEPL variation. CONCLUSION: We have established and explored a method to quantify the robustness towards inter-fractional motion of single beam proton plans treating the pelvic LNs from different beam configurations and with different CTV to PTV margins. For the patients investigated we were able to identify beam orientations that were robust to dose deterioration in the target and ORs.


Assuntos
Movimento , Neoplasias da Próstata/patologia , Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Metástase Linfática , Masculino , Movimento (Física) , Órgãos em Risco , Pelve , Doses de Radiação , Radioterapia de Intensidade Modulada/métodos , Reto , Bexiga Urinária
11.
Acta Oncol ; 54(9): 1326-34, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26340136

RESUMO

BACKGROUND: Gastrointestinal (GI) morbidity after radiotherapy (RT) for prostate cancer is typically addressed by studying specific single symptoms. The aim of this study was to explore the interplay between domains of patient- reported outcomes (PROs) on GI morbidity, and to what extent these are explained by RT dose to the GI tract. MATERIAL AND METHODS: The study included men from two Scandinavian studies (N = 211/277) who had undergone primary external beam radiotherapy (EBRT) for localized prostate cancer to 70-78 Gy (2 Gy/fraction). Factor analysis was applied to previously identified PRO-based symptom domains from two study-specific questionnaires. Number of questions: 43; median time to follow-up: 3.6-6.4 years) and dose-response outcome variables were defined from these domains. Dose/volume parameters of the anal sphincter (AS) or the rectum were tested as predictors for each outcome variable using logistic regression with 10-fold cross-validation. Performance was assessed using area under the receiver operating characteristic curve (Az) and model frequency. RESULTS: Outcome variables from Defecation urgency (number of symptoms: 2-3), Fecal leakage (4-6), Mucous (4), and Pain (3-6) were defined. In both cohorts, intermediate rectal doses predicted Defecation urgency (mean Az: 0.53-0.54; Frequency: 70-75%), and near minimum and low AS doses predicted Fecal leakage (mean Az: 0.63-0.67; Frequency: 83-99%). In one cohort, high AS doses predicted Mucous (mean Az: 0.54; Frequency: 96%), whereas in the other, low AS doses and intermediate rectal doses predicted Pain (mean Az: 0.69; Frequency: 28-82%). CONCLUSION: We have demonstrated that Defecation urgency, Fecal leakage, Mucous, and Pain following primary EBRT for localized prostate cancer primarily are predicted by intermediate rectal doses, low AS doses, high AS doses, or a combination of low AS and intermediate rectal doses, respectively. This suggests that there is a domain-specific dose-response for the GI tract. To reduce risk of GI morbidity, dose distributions of both the AS region and the rectum should, therefore, be considered when prescribing prostate cancer RT.


Assuntos
Trato Gastrointestinal/efeitos da radiação , Neoplasias da Próstata/radioterapia , Lesões por Radiação/etiologia , Radioterapia/efeitos adversos , Idoso , Defecação/efeitos da radiação , Relação Dose-Resposta à Radiação , Incontinência Fecal/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Órgãos em Risco/efeitos da radiação , Dor/etiologia
12.
Acta Oncol ; 53(10): 1329-36, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24957554

RESUMO

BACKGROUND: Methods to accurately accumulate doses in radiotherapy (RT) are important for tumour and normal tissues being influenced by geometric uncertainties. The purpose of this study was to investigate a pre-release deformable image registration (DIR)-based dose accumulation application, in the setting of prostate RT. MATERIAL AND METHODS: Initially accumulated bladder and prostate doses were assessed (based on 8-9 repeat CT scans/patient) for nine prostate cancer patients using an intensity-based DIR and dose accumulation algorithm as provided by the Dynamic Adaptive Radiation Therapy (DART) software. The accumulated bladder and prostate dose-volume histograms (DVHs) were compared on a range of parameters (paired Wilcoxon signed-rank test, 5% significance level) to DVHs derived using an in-house developed dose accumulation method based on biomechanical, contour-driven DIR (SurfaceRegistration). Finally, both these accumulated dose distributions were compared to the 'static' DVH, assessed from the planning CT. RESULTS: Over the population, doses accumulated with DART were overall lower than those from SurfaceRegistration (p < 0.05: D2%, gEUD and NTCP (bladder); Dmin (prostate)). The magnitude of these differences peaked for the bladder gEUD with a population median of 47 Gy for DART versus 57 Gy for SurfaceRegistration. Across the ten bladder dose/volume parameters investigated, the most pronounced individual differences were observed between the 'accumulated' DVHs and the 'static' DVHs, with deviations in mean dose up to 22 Gy. CONCLUSION: Substantial and significant differences were observed in the dose distributions between the two investigated DIR-based dose accumulation applications. The most pronounced individual differences were seen for the bladder and relative to the planned dose distribution, encouraging the use of repeat imaging data in RT planning and evaluation for this organ.


Assuntos
Próstata/efeitos da radiação , Neoplasias da Próstata/radioterapia , Bexiga Urinária/efeitos da radiação , Relação Dose-Resposta à Radiação , Humanos , Masculino , Órgãos em Risco/efeitos da radiação , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X/métodos , Bexiga Urinária/diagnóstico por imagem
13.
Acta Oncol ; 52(7): 1411-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23879649

RESUMO

BACKGROUND AND PURPOSE: Deformable image registration (DIR) is a key component of image-guided and adaptive strategies in radiotherapy. DIR based on image intensities alone is promising for online applications, but is challenged in regions with low intensity gradients. In this study we have investigated the performance of intensity- based DIR applied to contour propagation of the rectum and bladder, focusing on the consequences in terms of dose/volume parameters. MATERIAL AND METHODS: The rectum and bladder volumes were delineated in the planning computed tomography (pCT) scan and in 8-9 repeat CTs (Vmanual) for nine prostate cancer patients. The volumes from the pCT were propagated onto the repeat CTs using intensity-based DIR (Vprop). Dose/volume parameters for Vmanual and Vprop were derived by dose re-calculations following rigid registration on prostate fiducials. Linear regression was used to identify qualitative and quantitative volumetric measures of the DIR performance being associated with the differences in dose/volume parameters. RESULTS: The median differences in dose/volume parameters assessed for Vprop and Vmanual were modest, but individual differences ~7 Gy were seen. The observed differences in dose/volume parameters showed strong correlations to the measures of the DIR performance as well as with the volume variations, most pronounced for the rectum (R(2) = 0.63-0.85; p ≤ 0.05). CONCLUSION: Limitations in the intensity-based DIR algorithm resulted in large individual differences in dose/volume parameters between propagated and manually segmented volumes, which were correlated with volumetric measures of the DIR performance.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias da Próstata/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Radioterapia Guiada por Imagem , Reto/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Bexiga Urinária/diagnóstico por imagem , Algoritmos , Humanos , Masculino , Prognóstico , Neoplasias da Próstata/radioterapia , Intensificação de Imagem Radiográfica , Radioterapia de Intensidade Modulada
14.
Acta Oncol ; 52(3): 521-7, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23409771

RESUMO

UNLABELLED: Internal target and organ motion during treatment is a challenge in radiotherapy (RT) of the prostate and the involved elective targets, with residual motion being present also following image-guidance strategies. The aim of this study was to investigate organ motion-induced dose degradations for the prostate, seminal vesicle and the pelvic lymph node when treating these targets with proton therapy, using different image-guidance and delivery strategies. MATERIAL AND METHODS: Four patients were selected from a larger series as they displayed large inter-fractional variation in bladder and rectum volume. Intensity-modulated proton therapy plans were generated using both simultaneous integrated and sequential boost delivery. For each technique, three isotropic margin expansions (in the range of 4-10 mm) were evaluated for the clinical target volume of prostate (CTV-p), seminal vesicles (CTV-sv) and lymph nodes (CTV-ln). Simulation of the dose degradations for all treatment plans were based on dose re-calculations for the 8-9 repeat CTs available for each patient, after applying rigid registrations to reproduce set-up based on either intra-prostatic fiducials or bony anatomy. RESULTS: The simulated dose received by 99% of the target volume (D(99)) and generalized equivalent dose (gEUD) showed substantial inter-patient variations. For 40% of the investigated scenarios, the patient average simulated D(99) for all targets were within 2 GyE from the planned dose. The largest difference between simulated and planned dose was seen for the CTV-sv when using SIB delivery, with an average relative reduction in D(99) of 13% and 15% for the largest margin expansion, when positioned using fiducials and bony anatomy, respectively. CONCLUSIONS: The most severe dose degradations were found for CTV-sv, but they were also evident for CTV-ln. The degradations could not be completely resolved, neither by using the largest margin expansion nor with the choice of set-up. With fiducial set-up CTV-p was robust against the inter-fraction changes.


Assuntos
Fracionamento da Dose de Radiação , Próstata/patologia , Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Simulação por Computador , Relação Dose-Resposta à Radiação , Humanos , Masculino , Movimento (Física) , Tamanho do Órgão , Posicionamento do Paciente , Pelve/diagnóstico por imagem , Pelve/patologia , Próstata/efeitos da radiação , Terapia com Prótons/efeitos adversos , Erros de Configuração em Radioterapia/prevenção & controle , Radioterapia de Intensidade Modulada/efeitos adversos , Reto/diagnóstico por imagem , Reto/patologia , Tomografia Computadorizada por Raios X/métodos , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/patologia
15.
Clin Transl Radiat Oncol ; 41: 100632, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37441541

RESUMO

The Danish Prostate Cancer Group is launching the randomized trial, PROstate PROTON Trial 1 (NCT05350475), that compares photons and protons to the prostate and pelvic lymph nodes in treatment of high-risk prostate cancer. The aim of the work described in this paper was, in preparation of this trial, to establish a strategy for conventionally fractionated proton therapy of prostate and elective pelvic lymph nodes that is feasible and robust. Proton treatments are image-guided based on gold fiducial markers and on-board imaging systems in line with current practice. Our established proton beam configuration consists of four coplanar fields; two posterior oblique fields and two lateral oblique fields, chosen to minimize range uncertainties associated with penetrating a varying amount of material from both treatment couch and patient body. Proton plans are robustly optimized to ensure target coverage while keeping normal tissue doses as low as is reasonably achievable throughout the course of treatment. Specific focus is on dose to the bowel as a reduction in gastrointestinal toxicity is the primary endpoint of the trial. Strategies have been established using previously treated patients and will be further investigated and evaluated through the ongoing pilot phase of the trial.

16.
Radiother Oncol ; 171: 62-68, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35033604

RESUMO

INTRODUCTION: In vivo dosimetry (IVD) can be used for source tracking (ST), i.e., estimating source positions, during brachytherapy. The aim of this study was to exploit IVD-based ST to perform 3D dose reconstruction for high-dose-rate prostate brachytherapy and to evaluate the robustness of the treatments against observed geometric variations. MATERIALS AND METHODS: Twenty-three fractions of high-dose-rate prostate brachytherapy were analysed. The treatment planning was based on MRI. Time-resolved IVD was performed using a fibre-coupled scintillator. ST was retrospectively performed using the IVD measurements. The ST identified 2D positional shifts of each treatment catheter and thereby inferred updated source positions. For each fraction, the dose was recalculated based on the source-tracked catheter positions and compared with the original plan dose using differences in dose volume histogram indices. RESULTS: Of 352 treatment catheters, 344 had shifts of less than 5 mm. Shifts between 5 and 10 mm were observed for 3 catheters, and shifts greater than 10 mm for 2 catheters. The ST failed for 3 catheters. The maximum relative difference in clinical target volume (prostate + 3 mm isotropic margin) D90% was 5%. In one fraction, the bladder D2cm3 dose increased by 18% (1.4 Gy) due to a single source position being inside the bladder rather than nearby as planned. The max increase in urethra dose was 1.5 Gy (15%). CONCLUSION: IVD-based 3D dose reconstruction for high-dose-rate prostate brachytherapy is feasible. The dosimetric impact of the observed catheter shifts was limited. Dose reconstruction can therefore aid in determining the dosimetric impact of geometric variations and errors in brachytherapy.


Assuntos
Braquiterapia , Dosimetria in Vivo , Neoplasias da Próstata , Catéteres , Humanos , Masculino , Próstata , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos
17.
Biomed Phys Eng Express ; 8(2)2022 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-35108695

RESUMO

Introduction.Internal organ motion and deformations may cause dose degradations in proton therapy (PT) that are challenging to resolve using conventional image-guidance strategies. This study aimed to investigate the potential ofrange guidanceusing water-equivalent path length (WEPL) calculations to detect dose degradations occurring in PT.Materials and methods. Proton ranges were estimated using WEPL calculations. Field-specific isodose surfaces in the planning CT (pCT), from robustly optimised five-field proton plans (opposing lateral and three posterior/posterior oblique beams) for locally advanced prostate cancer patients, were used as starting points. WEPLs to each point on the field-specific isodoses in the pCT were calculated. The corresponding range for each point was found in the repeat CTs (rCTs). The spatial agreement between the resulting surfaces in the rCTs (hereafter referred to as iso-WEPLs) and the isodoses re-calculated in rCTs was evaluated for different dose levels and Hausdorff thresholds (2-5 mm). Finally, the sensitivity and specificity of detecting target dose degradation (V95% < 95%) using spatial agreement measures between the iso-WEPLs and isodoses in the pCT was evaluated.Results. The spatial agreement between the iso-WEPLs and isodoses in the rCTs depended on the Hausdorff threshold. The agreement was 65%-88% for a 2 mm threshold, 83%-96% for 3 mm, 90%-99% for 4 mm, and 94%-99% for 5 mm, across all fields and isodose levels. Minor differences were observed between the different isodose levels investigated. Target dose degradations were detected with 82%-100% sensitivity and 75%-80% specificity using a 2 mm Hausdorff threshold for the lateral fields.Conclusion. Iso-WEPLs were comparable to isodoses re-calculated in the rCTs. The proposed strategy could detect target dose degradations occurring in the rCTs and could be an alternative to a fully-fledged dose re-calculation to detect anatomical variations severely influencing the proton range.


Assuntos
Neoplasias da Próstata , Terapia com Prótons , Humanos , Masculino , Movimentos dos Órgãos , Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Prótons , Planejamento da Radioterapia Assistida por Computador/métodos
18.
Acta Oncol ; 50(6): 918-25, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21767192

RESUMO

BACKGROUND AND PURPOSE: Daily organ motion occurring during the course of radiotherapy in the pelvic region leads to uncertainties in the doses delivered to the tumour and the organs at risk. Motion patterns include both volume and shape changes, calling for deformable image registration (DIR), in approaches involving dose accumulation and adaptation. In this study, we tested the performance of a DIR application for contour propagation from the treatment planning computed tomography (pCT) to repeat cone-beam CTs (CBCTs) for a set of prostate cancer patients. MATERIAL AND METHODS: The prostate, rectum and bladder were delineated in the pCT and in six to eight repeat CBCTs for each of five patients. The pCT contours were propagated onto the corresponding CBCT using the Multi-modality Image Registration and Segmentation application, resulting in 36 registrations. Prior to the DIR, a rigid registration was performed. The algorithm used for the DIR was based on a 'demons' algorithm and the performance of it was examined quantitatively using the Dice similarity coefficient (DSC) and qualitatively as visual slice-by-slice scoring by a radiation oncologist grading the deviations in shape and/or distance relative to the anatomy. RESULTS: The average DSC (range) for the DIR over all scans and patients was 0.80 (0.65-0.87) for prostate, 0.77 (0.63-0.87) for rectum and 0.73 (0.34-0.91) for bladder, while the corresponding DSCs for the rigid registrations were 0.77 (0.65-0.86), 0.71 (0.55-0.82) and 0.64 (0.33-0.87). The percentage of propagated contours of good/acceptable quality was 45% for prostate; 20% for rectum and 33% for bladder. For the bladder, there was an association between the average DSC and the different scores of the qualitative evaluation. CONCLUSIONS: DIR improved the performance of pelvic organ contour propagation from the pCT to CBCTs as compared to rigid registration only. Still, a large fraction of the propagated rectum and bladder contours were unacceptable. The image quality of the CBCTs was sub-optimal and the usability of CBCTs for dose accumulation and adaptation purposes is therefore likely to benefit from improved image quality and improvements of the DIR algorithm.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Algoritmos , Humanos , Masculino , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/radioterapia , Intensificação de Imagem Radiográfica , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/radioterapia , Estudos Retrospectivos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/radioterapia
19.
Acta Oncol ; 50(6): 926-34, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21767193

RESUMO

BACKGROUND AND PURPOSE: Uncorrelated motion of targets and large deformations of organs at risk represent challenges for image-guidance in simultaneous integrated boost (SIB) radiotherapy (RT) of pelvic tumour sites. This study aims to evaluate the robustness towards geometrical uncertainties in prostate cancer using two image-guided RT (IGRT) set-up strategies for two SIB delivery methods. Secondly, we evaluate the ability of geometrical parameters to predict when the applied margins are insufficient, resulting in target underdosage (TUD). MATERIAL AND METHODS: The study included nine patients with eight to nine repeat computed tomography (CT)-scans evenly distributed throughout their treatment course. The prostate target (CTV-p) and the lymph node target including seminal vesicles (CTV-ln/sv) were delineated in all scans. SIB treatment plans for intensity-modulated RT and volumetric modulated arc therapy were generated on the planning CT and transferred to the repeat CTs for dose re-calculation using registration based on either anatomy or intra-prostatic fiducial markers. Receiving operator characteristic analysis was used to deduce the ability of the parameters to predict TUD. RESULTS: The dosimetric differences between the two positioning strategies were small for all parameters evaluated and significant only for the dose to rectum. Anatomy based registration resulted in inferior target coverage with a larger number of TUDs, mostly seen in the seminal vesicles. For both targets the highest sensitivity and specificity of predicting TUD was seen for the relative volume and the lowest was found for the displacement vector. CONCLUSIONS: Positioning based on fiducials gave the best trade-off between coverage of the targets although resulting in the highest dose to rectum. Target underdosage occurred mostly in the seminal vesicles. For both targets, the best parameter to predict TUD was the relative volume.


Assuntos
Processamento de Imagem Assistida por Computador , Linfonodos/diagnóstico por imagem , Linfonodos/efeitos da radiação , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia de Intensidade Modulada , Algoritmos , Humanos , Masculino , Neoplasias Pélvicas/diagnóstico por imagem , Neoplasias Pélvicas/radioterapia , Curva ROC , Planejamento da Radioterapia Assistida por Computador , Neoplasias Retais/diagnóstico por imagem , Neoplasias Retais/radioterapia , Tomografia Computadorizada por Raios X , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/radioterapia
20.
Med Phys ; 48(5): 2614-2623, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33655555

RESUMO

PURPOSE: To report on the accuracy of an in vivo dosimetry (IVD)-based source tracking (ST) method for high dose rate (HDR) prostate brachytherapy (BT). METHODS: The ST was performed on a needle-by-needle basis. A least square fit of the expected to the measured dose rate was performed using the active dwell positions in the given needle. Two fitting parameters were used to determine the position of each needle relative to the IVD detector: radial (away or toward the detector) and longitudinal (along the axis of the treatment needle). The accuracy of the ST was assessed in a phantom where the geometries of five HDR prostate BT treatments previously treated at our clinic were reproduced. For each of the five treatment geometries, one irradiation was performed with the detector placed in the middle of the implant. Furthermore, four additional irradiations were performed for one of the geometries where the detector was retracted caudally in four steps of 10-15 mm and up to 12 mm inferior of the most inferior active dwell position, which represented the prostate apex. The time resolved dose measurements were retrieved at a rate of 20 Hz using a detector based on an Al2 O3 :C radioluminescence crystal, which was placed inside a standard BT needle. Individual calibrations of the detector were performed prior to each of the nine irradiations. RESULTS: Source tracking could be applied in all needles across all nine irradiations. For irradiations with the detector located in the middle region of the implant (a total of 89 needles), the mean ± standard deviation (SD, k = 1) accuracy was -0.01 mm ± 0.38 mm and 0.30 mm ± 0.38 mm in the radial and longitudinal directions, respectively. Caudal retraction of the detector did not lead to reduced accuracy as long as the detector was located superior to the most inferior active dwell positions in all needles. However, reduced accuracy was observed for detector positions inferior to the most inferior active dwell positions which corresponded to detector positions in and inferior to the prostate apex region. Detector positions in the prostate apex and 12 mm inferior to the prostate resulted in mean ± SD (k = 1) ST accuracy of 0.7 mm ± 1 mm and 2.8 mm ± 1.6 mm, respectively, in radial direction, and -1.7 mm ± 1 mm and -2.1 mm ± 1.1 mm, respectively, in longitudinal direction. The largest deviations for the configurations with those detector positions were 2.6 and 5.4 mm, respectively, in the radial direction and -3.5 and -3.8 mm, respectively, in the longitudinal direction. CONCLUSION: This phantom study demonstrates that ST based on IVD during prostate BT is adequately accurate for clinical use. The ST yields submillimeter accuracy on needle positions as long as the IVD detector is positioned superior to at least one active dwell position in all needles. Locations of the detector inferior to the prostate apex result in decreased ST accuracy while detector locations in the apex region and above are advantageous for clinical applications.


Assuntos
Braquiterapia , Dosimetria in Vivo , Neoplasias da Próstata , Humanos , Masculino , Imagens de Fantasmas , Próstata , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA