Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Pancreatology ; 24(3): 394-403, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38493004

RESUMO

BACKGROUND: Many affected by pancreatitis harbor rare variants of the cystic fibrosis (CF) gene, CFTR, which encodes an epithelial chloride/bicarbonate channel. We investigated CFTR function and the effect of CFTR modulator drugs in pancreatitis patients carrying CFTR variants. METHODS: Next-generation sequencing was performed to identify CFTR variants. Sweat tests and nasal potential difference (NPD) assays were performed to assess CFTR function in vivo. Intestinal current measurement (ICM) was performed on rectal biopsies. Patient-derived intestinal epithelial monolayers were used to evaluate chloride and bicarbonate transport and the effects of a CFTR modulator combination: elexacaftor, tezacaftor and ivacaftor (ETI). RESULTS: Of 32 pancreatitis patients carrying CFTR variants, three had CF-causing mutations on both alleles and yielded CF-typical sweat test, NPD and ICM results. Fourteen subjects showed a more modest elevation in sweat chloride levels, including three that were provisionally diagnosed with CF. ICM indicated impaired CFTR function in nine out of 17 non-CF subjects tested. This group of nine included five carrying a wild type CFTR allele. In epithelial monolayers, a reduction in CFTR-dependent chloride transport was found in six out of 14 subjects tested, whereas bicarbonate secretion was reduced in only one individual. In epithelial monolayers of four of these six subjects, ETI improved CFTR function. CONCLUSIONS: CFTR function is impaired in a subset of pancreatitis patients carrying CFTR variants. Mutations outside the CFTR locus may contribute to the anion transport defect. Bioassays on patient-derived intestinal tissue and organoids can be used to detect such defects and to assess the effect of CFTR modulators.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística , Fibrose Cística , Pancreatite , Humanos , Bicarbonatos/metabolismo , Cloretos , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Mutação , Pancreatite/genética , Pancreatite/metabolismo , Quinolonas
2.
Pancreatology ; 24(4): 538-544, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38693038

RESUMO

BACKGROUND/OBJECTIVES: Autoimmune pancreatitis (AIP) is a steroid-responsive inflammatory disease of the pancreas. Few studies investigated pancreatic exocrine function (PEF) in patients suffering from AIP and no definitive data are available on the effect of steroids in PEF recovery. Aim of the study is the evaluation of severe pancreatic insufficiency (sPEI) prevalence in AIP at clinical onset and after steroid treatment. METHODS: 312 Patients with diagnosis of AIP between January 1st, 2010 and December 31st, 2020 were identified in our prospectively maintained register. Patients with a pre-steroid treatment dosage of fecal elastase-1 (FE-1) were included. Changes in PEF were evaluated in patients with available pre- and post-treatment FE (between 3 and 12 months after steroid). RESULTS: One-hundred-twenty-four patients were included, with a median FE-1 of 122 (Q1-Q3: 15-379) µg/g at baseline. Fifty-nine (47.6 %) had sPEI (FE-1<100 µg/g). Univariable analysis identified type 1 AIP, radiological involvement of the head of the pancreas (diffuse involvement of the pancreas or focal involvement of the head), weight loss, age and diabetes as associated with a greater risk of sPEI. However, at multivariable analysis, only the involvement of the head of the pancreas was identified as independent risk factor for sPEI. After steroids, mean FE-1 changed from 64 (15-340) to 202 (40-387) µg/g (P = 0.058) and head involvement was the only predictor of improvement of sPEI. CONCLUSION: The inflammatory involvement of the head of the pancreas is associated with PEF severity, as well as PEF improvement after treatment with steroids in patients with AIP.


Assuntos
Pancreatite Autoimune , Insuficiência Pancreática Exócrina , Humanos , Pancreatite Autoimune/tratamento farmacológico , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Insuficiência Pancreática Exócrina/tratamento farmacológico , Pâncreas Exócrino/efeitos dos fármacos , Adulto , Esteroides/uso terapêutico , Elastase Pancreática
3.
Pancreatology ; 23(4): 429-436, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37169669

RESUMO

BACKGROUND/OBJECTIVES: Death domain-associated protein (DAXX) and/or α-thalassemia/mental retardation X-linked (ATRX) chromatin remodeling genes mutations and alternative lengthening of telomeres (ALT) activation are associated with more aggressive behavior of non-functional pancreatic neuroendocrine tumors (NF-PanNETs). We aimed to evaluate the reliability of such markers on endoscopic-ultrasound fine-needle biopsy (EUS-FNB) specimens. METHODS: Patients who underwent EUS-FNB and subsequent surgical resection for PanNETs between January 2017 and December 2019 were retrospectively identified. Immunohistochemistry (IHC) to evaluate DAXX/ATRX expression and fluorescence in situ hybridization (FISH) for ALT status were performed. Primary outcome was the concordance rate of markers expression between EUS-FNB and surgical specimens. Secondary aims were association between markers and lesion aggressiveness, their diagnostic performance in predicting aggressiveness, and agreement of preoperative and post-surgical Ki67-based grading. RESULTS: Forty-one NF-PanNETs (mean diameter 36.1 ± 26.5 mm) were included. Twenty-four showed features of lesion aggressiveness. Concordance of expressions of DAXX, ATRX, and ALT status between EUS-FNB and surgical specimens were 95.1% (κ = 0.828; p < 0.001), 92.7% (κ = 0.626; p < 0.001), and 100% (κ = 1; p < 0.001), respectively. DAXX/ATRX loss and ALT-positivity were significantly (p < 0.05) associated with metastatic lymphnodes and lymphovascular invasion. The combination of all tumor markers (DAXX/ATRX loss + ALT-positivity + grade 2) reached an accuracy of 73.2% (95%CI 57.1-85.8) in identifying aggressive lesions. Pre- and post-operative ki-67-based grading was concordant in 80.5% of cases (k = 0.573; p < 0.001). CONCLUSION: DAXX/ATRX expression and ALT status can be accurately evaluated in a preoperative setting on EUS-FNB samples, potentially improving the identification of patients with increased risk and poorer prognosis.


Assuntos
Deficiência Intelectual , Tumores Neuroendócrinos , Neoplasias Pancreáticas , Talassemia alfa , Humanos , Proteína Nuclear Ligada ao X/genética , Proteína Nuclear Ligada ao X/metabolismo , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/genética , Tumores Neuroendócrinos/cirurgia , Estudos Retrospectivos , Biópsia por Agulha Fina , Hibridização in Situ Fluorescente , Reprodutibilidade dos Testes , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Neoplasias Pancreáticas/cirurgia , Telômero/genética , Telômero/metabolismo , Telômero/patologia , Chaperonas Moleculares/genética , Proteínas Correpressoras/genética
4.
Endoscopy ; 55(3): 225-234, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35915956

RESUMO

BACKGROUND : It is unknown whether there is an advantage to using the wet-suction or slow-pull technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) with new-generation needles. We aimed to compare the performance of each technique in EUS-FNB. METHODS: This was a multicenter, randomized, single-blind, crossover trial including patients with solid lesions of ≥ 1 cm. Four needle passes with 22 G fork-tip or Franseen-type needles were performed, alternating the wet-suction and slow-pull techniques in a randomized order. The primary outcome was the histological yield (samples containing an intact piece of tissue of at least 550 µm). Secondary end points were sample quality (tissue integrity and blood contamination), diagnostic accuracy, and adequate tumor fraction. RESULTS: Overall, 210 patients with 146 pancreatic and 64 nonpancreatic lesions were analyzed. A tissue core was retrieved in 150 (71.4 %) and 129 (61.4 %) cases using the wet-suction and the slow-pull techniques, respectively (P = 0.03). The mean tissue integrity score was higher using wet suction (P = 0.02), as was the blood contamination of samples (P < 0.001). In the two subgroups of pancreatic and nonpancreatic lesions, tissue core rate and tissue integrity score were not statistically different using the two techniques, but blood contamination was higher with wet suction. Diagnostic accuracy and tumor fraction did not differ between the two techniques. CONCLUSION: Overall, the wet-suction technique in EUS-FNB resulted in a higher tissue core procurement rate compared with the slow-pull method. Diagnostic accuracy and the rate of samples with adequate tumor fraction were similar between the two techniques.


Assuntos
Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Sucção/métodos , Estudos Cross-Over , Método Simples-Cego , Pâncreas/diagnóstico por imagem , Pâncreas/patologia
5.
Endoscopy ; 55(2): 129-137, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36044915

RESUMO

BACKGROUND : The advantage of using the macroscopic on-site evaluation (MOSE) technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed with 22G Franseen needles has not been investigated. We aimed to compare EUS-FNB with MOSE vs. EUS-FNB performed with three needle passes. METHODS : This randomized trial involved 10 Italian referral centers. Consecutive patients referred for EUS-FNB of pancreatic or nonpancreatic solid lesions were included in the study and randomized to the two groups. MOSE was performed by gross visualization of the collected material by the endoscopists and considered adequate when a white/yellowish aggregate core longer than 10 mm was retrieved. The primary outcome was diagnostic accuracy. Secondary outcomes were specimen adequacy, number of needle passes, and safety. RESULTS : 370 patients with 234 pancreatic lesions (63.2 %) and 136 nonpancreatic lesions (36.8 %) were randomized (190 EUS-FNB with MOSE and 180 with standard EUS-FNB). No statistically significant differences were found between EUS-FNB with MOSE and conventional EUS-FNB in terms of diagnostic accuracy (90.0 % [95 %CI 84.8 %-93.9 %] vs. 87.8 % [95 %CI 82.1 %-92.2 %]; P = 0.49), sample adequacy (93.1 % [95 %CI 88.6 %-96.3 %] vs. 95.5 % [95 %CI 91.4 %-98 %]; P = 0.31), and rate of adverse events (2.6 % vs. 1.1 %; P = 0.28). The median number of passes was significantly lower in the EUS-FNB with MOSE group (1 vs. 3; P < 0.001). CONCLUSIONS : The accuracy of EUS-FNB with MOSE is noninferior to that of EUS-FNB with three needle passes. MOSE reliably assesses sample adequacy and reduces the number of needle passes required to obtain the diagnosis with a 22G Franseen needle.


Assuntos
Neoplasias Pancreáticas , Humanos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Biópsia Guiada por Imagem , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia
6.
Gastroenterology ; 161(1): 185-195, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33741314

RESUMO

BACKGROUND & AIMS: Benign biliary strictures (BBS) are complications of chronic pancreatitis (CP). Endotherapy using multiple plastic stents (MPS) or a fully covered self-expanding metal stent (FCSEMS) are acceptable treatment options for biliary obstructive symptoms in these patients. METHODS: Patients with symptomatic CP-associated BBS enrolled in a multicenter randomized noninferiority trial comparing 12-month treatment with MPS vs FCSEMS. Primary outcome was stricture resolution status at 24 months, defined as absence of restenting and 24-month serum alkaline phosphatase not exceeding twice the level at stenting completion. Secondary outcomes included crossover rate, numbers of endoscopic retrograde cholangiopancreatography (ERCPs) and stents, and stent- or procedure-related serious adverse events. RESULTS: Eighty-four patients were randomized to MPS and 80 to FCSEMS. Baseline technical success was 97.6% for MPS and 98.6% for FCSEMS. Eleven patients crossed over from MPS to FCSEMS, and 10 from FCSEMS to MPS. For MPS vs FCSEMS, respectively, stricture resolution status at 24 months was 77.1% (54/70) vs 75.8% (47/62) (P = .008 for noninferiority intention-to-treat analysis), mean number of ERCPs was 3.9 ± 1.3 vs 2.6 ± 1.3 (P < .001, intention-to-treat), and mean number of stents placed was 7.0 ± 4.4 vs 1.3 ± .6 (P < .001, as-treated). Serious adverse events occurred in 16 (19.0%) MPS and 19 (23.8%) FCSEMS patients (P = .568), including cholangitis/fever/jaundice (9 vs 7 patients respectively), abdominal pain (5 vs 5), cholecystitis (1 vs 3) and post-ERCP pancreatitis (0 vs 2). No stent- or procedure-related deaths occurred. CONCLUSIONS: Endotherapy of CP-associated BBS has similar efficacy and safety for 12-month treatment using MPS compared with a single FCSEMS, with FCSEMS requiring fewer ERCPs over 2 years. (ClinicalTrials.gov, Number: NCT01543256.).


Assuntos
Colestase/terapia , Materiais Revestidos Biocompatíveis , Drenagem/instrumentação , Pancreatite Crônica/complicações , Plásticos , Stents Metálicos Autoexpansíveis , Stents , Adulto , Idoso , Colestase/diagnóstico por imagem , Colestase/etiologia , Drenagem/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pancreatite Crônica/diagnóstico , Desenho de Prótese , Resultado do Tratamento
7.
Gastroenterology ; 161(3): 899-909.e5, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34116031

RESUMO

BACKGROUND AND AIMS: The benefit of rapid on-site evaluation (ROSE) on the diagnostic accuracy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) has never been evaluated in a randomized study. This trial aimed to test the hypothesis that in solid pancreatic lesions (SPLs), diagnostic accuracy of EUS-FNB without ROSE was not inferior to that of EUS-FNB with ROSE. METHODS: A noninferiority study (noninferiority margin, 5%) was conducted at 14 centers in 8 countries. Patients with SPLs requiring tissue sampling were randomly assigned (1:1) to undergo EUS-FNB with or without ROSE using new-generation FNB needles. The touch-imprint cytology technique was used to perform ROSE. The primary endpoint was diagnostic accuracy, and secondary endpoints were safety, tissue core procurement, specimen quality, and sampling procedural time. RESULTS: Eight hundred patients were randomized over an 18-month period, and 771 were analyzed (385 with ROSE and 386 without). Comparable diagnostic accuracies were obtained in both arms (96.4% with ROSE and 97.4% without ROSE, P = .396). Noninferiority of EUS-FNB without ROSE was confirmed with an absolute risk difference of 1.0% (1-sided 90% confidence interval, -1.1% to 3.1%; noninferiority P < .001). Safety and sample quality of histologic specimens were similar in both groups. A significantly higher tissue core rate was obtained by EUS-FNB without ROSE (70.7% vs. 78.0%, P = .021), with a significantly shorter mean sampling procedural time (17.9 ± 8.8 vs 11.7 ± 6.0 minutes, P < .0001). CONCLUSIONS: EUS-FNB demonstrated high diagnostic accuracy in evaluating SPLs independently on execution of ROSE. When new-generation FNB needles are used, ROSE should not be routinely recommended. (ClinicalTrial.gov number NCT03322592.).


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas/patologia , Avaliação Rápida no Local , Idoso , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
8.
Endoscopy ; 54(12): 1158-1168, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35451041

RESUMO

BACKGROUND AND STUDY AIMS : Endoscopic ultrasound-guided through-the-needle biopsy (TTNB) of pancreatic cystic lesions (PCLs) is associated with a non-negligible risk for adverse events (AEs). We aimed to identify the hierarchic interaction among independent predictors for TTNB-related AEs and to generate a prognostic model using recursive partitioning analysis (RPA). PATIENTS AND METHODS : Multicenter retrospective analysis of 506 patients with PCLs who underwent TTNB. RPA of predictors for AEs was performed and the model was validated by means of bootstrap resampling. RESULTS : Mean cysts size was 36.7 mm. Most common diagnoses were intraductal papillary mucinous neoplasm (IPMN, 45 %), serous cystadenoma (18.8 %), and mucinous cystadenoma (12.8 %). Fifty-eight (11.5 %) AEs were observed. At multivariate analysis, age (odds ratio [OR] 1.32, 1.09-2.14; p = 0.05), number of TTNB passes (OR from 2.17, 1.32-4.34 to OR 3.16, 2.03-6.34 with the increase of the number of passes), complete aspiration of the cyst (OR 0.56, 0.31-0.95; p = 0.02), and diagnosis of IPMN (OR 4.16, 2.27-7.69; p < 0.001) were found to be independent predictors of AEs, as confirmed by logistic regression and random forest analyses. RPA identified three risk classes: high-risk (IPMN sampled with multiple microforceps passes, 28 % AEs rate), low-risk (1.4 % AE rate, including patients < 64 years with other-than-IPMN diagnosis sampled with ≤ 2 microforceps passes and with complete aspiration of the cyst) and middle-risk class (6.1 % AEs rate, including the remaining patients). CONCLUSION : TTNB should be selectively used in the evaluation of patients with IPMN. The present model could be applied during patient selection as to optimize the benefit/risk of TTNB.


Assuntos
Cisto Pancreático , Neoplasias Intraductais Pancreáticas , Neoplasias Pancreáticas , Humanos , Neoplasias Intraductais Pancreáticas/patologia , Estudos Retrospectivos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Cisto Pancreático/patologia , Endossonografia/efeitos adversos , Neoplasias Pancreáticas/patologia
9.
Pancreatology ; 21(4): 805-811, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33745788

RESUMO

BACKGROUND: We aimed to assess factors impacting the endoscopic minor papilla sphincterotomy (EMPS) success rate, clinical efficacy, and safety in a large cohort of patients with symptomatic pancreas divisum (PD). METHODS: Retrospective study including patients with PD referred to the Pancreas Institute of Verona from May 2009 to May 2020 to undergo EMPS. The whole population was analyzed to assess EMPS technical success, defined as the rate of deep cannulation of the dorsal duct. Patients treated for recurrent pancreatitis (RP) with a minimum follow-up of 1 year were included to evaluate the clinical efficacy, defined as resolution or significant reduction of acute pancreatitis (AP) episodes. Safety was defined as the rate of procedure-related adverse events (AEs) according to an international lexicon. The effects of the main determinants on study outcomes were evaluated. RESULTS: Overall, 106 patients were evaluated. Technical success was obtained in 87 (82.1%). The presence of pancreatic calcifications was associated with failure (p < 0.0001). Clinical efficacy was evaluated in 59 patients. Resolution/reduction of AP episodes after EMPS was observed in 93% of patients over a median follow-up of 49 months (IQR 37-92). Smoking habit was associated with AP recurrence (p = 0.026). The overall AE rate was 14.9%, with post-ERCP pancreatitis as the most common complication (12.6%). CONCLUSIONS: In our study, performed at a tertiary center, EMPS showed satisfactory technical success and an acceptable safety profile. If confirmed by prospective multicenter studies, EMPS could become the standard of care for the treatment of RP in PD.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pancreatite Crônica , Doença Aguda , Cateterismo , Humanos , Pâncreas , Ductos Pancreáticos/cirurgia , Estudos Prospectivos , Estudos Retrospectivos , Esfinterotomia Endoscópica/efeitos adversos , Resultado do Tratamento
10.
Pancreatology ; 21(2): 443-450, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33390343

RESUMO

BACKGROUND/OBJECTIVES: Studies comparing EUS-guided fine-needle aspiration (EUS-FNA) with EUS-guided fine-needle biopsy (EUS-FNB) for the evaluation of pancreatic neuroendocrine tumors (pNETs) are lacking. We aimed at comparing EUS-FNA with EUS-FNB in terms of Ki-67 proliferative index (PI) estimation capability, cellularity of the samples, and reliability of Ki-67 PI/tumor grading compared with surgical specimens. METHODS: Patients diagnosed with pNETs on EUS and/or surgical specimens were retrospectively identified. Specimens were re-evaluated to assess Ki-67 PI feasibility, sample cellularity by manual counting, and determination of Ki-67 PI value. Outcomes in the EUS-FNA and EUS-FNB groups were compared. Kendall rank test was used for Ki-67 PI correlation between EUS and surgical specimens. Subgroup analysis including small (≤20 mm), non-functioning pNETs was performed. RESULTS: Three-hundred samples from 292 lesions were evaluated: 69 EUS-FNA cytology and 231 EUS-FNB histology. Ki-67 PI feasibility was similar for EUS-FNA and EUS-FNB (91.3% vs. 95.7%, p = 0.15), while EUS-FNB performed significantly better in the subgroup of 179 small pNETs (88.2% vs. 96.1%, p = 0.04). Rate of poor cellulated (<500 cells) specimens was equal between EUS-FNA and EUS-FNB. A significant correlation for Ki-67 PI values between EUS and 92 correspondent surgical specimens was found in both groups, but it was stronger with EUS-FNB (tau = 0.626, p < 0.0001 vs. tau = 0.452, p = 0.031). Correct grading estimation was comparable between the two groups (p = 0.482). CONCLUSION: Our study showed stronger correlation for Ki-67 values between EUS-FNB and surgical specimens, and that EUS-FNB outperformed EUS-FNA in the evaluation of small pNETs. EUS-FNB should become standard of care for grading assessment of suspected pNETs.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia , Adulto , Idoso , Biópsia por Agulha Fina/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
11.
World J Surg Oncol ; 19(1): 65, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33648512

RESUMO

BACKGROUND: Synovial sarcoma (SS) is a rare soft tissue tumor. Among different anatomical locations where it can be found, gastric localization is a very uncommon one. Based on soft tissue sarcoma guidelines, complete tumor excision is considered the main treatment approach. Depending on size and localization of the tumor, both wedge and major gastric resections have been performed in the past for the treatment of this condition. CASE PRESENTATION: We present the case of a 43-year-old woman who underwent a laparoscopic intragastric excision of a gastric 10-mm SS located nearby the esophagogastric junction. Pathology examination confirmed the presence of a SS. The resected specimen confirmed margin-free excision of a monophasic spindle cell neoplasm invading the submucosa and presenting the rearrangement of SS18 gene at fluorescence in situ hybridization (FISH). No adjuvant treatment was offered, and 18 months after surgery, the patient was alive and disease free. CONCLUSIONS: This represents the first case reported in literature of a laparoscopic intragastric resection for a gastric SS. This approach allowed to obtain a full thickness radical tumor resection with the advantages of minimally invasive and organ preserving surgery.


Assuntos
Laparoscopia , Sarcoma Sinovial , Neoplasias Gástricas , Adulto , Feminino , Humanos , Hibridização in Situ Fluorescente , Prognóstico , Sarcoma Sinovial/diagnóstico por imagem , Sarcoma Sinovial/cirurgia , Neoplasias Gástricas/cirurgia
12.
Ultraschall Med ; 42(2): 167-177, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31597179

RESUMO

BACKGROUND AND STUDY AIMS: On contrast-enhanced imaging studies, nonhypovascular (i. e., isovascular and hypervascular) patterns can be observed in solid pancreatic lesions (SPLs) of different nature, prognosis, and management. We aimed to identify endoscopic ultrasound (EUS) features of nonhypovascular SPLs associated with malignancy/aggressiveness. The secondary aims were EUS tissue acquisition (EUS-TA) outcome and safety in this setting of patients. PATIENTS AND METHODS: This prospective observational study included patients with nonhypovascular SPLs detected on cross-sectional imaging and referred for EUS-TA. Lesion features (size, site, margins, echotexture, vascular pattern, and upstream dilation of the main pancreatic duct) were recorded. Malignancy/aggressiveness was determined by evidence of carcinoma at biopsy/surgical pathology, signs of aggressiveness (perineural invasion, lymphovascular invasion, and/or microscopic tumor extension/infiltration or evidence of metastatic lymph nodes) in the surgical specimen, radiologic detection of lymph nodes or distant metastases, and/or tumor growth > 5 mm/6 months. Uni- and multivariate analyses were performed to assess the primary aim. RESULTS: A total of 154 patients with 161 SPLs were enrolled. 40 (24.8 %) lesions were defined as malignant/aggressive. Irregular margins and size > 20 mm were independent factors associated with malignancy/aggressiveness (p < 0.001, OR = 5.2 and p = 0.003, OR = 2.1, respectively). However, size > 20 mm was not significant in the subgroup of other-than-neuroendocrine tumor (NET) lesions. The EUS-TA accuracy was 92 %, and the rate of adverse events was 4 %. CONCLUSION: Irregular margins on EUS are associated with malignancy/aggressiveness of nonhypovascular SPLs. Size > 20 mm should be considered a malignancy-related feature only in NET patients. EUS-TA is safe and highly accurate for differential diagnosis in this group of patients.


Assuntos
Tumores Neuroendócrinos , Neoplasias Pancreáticas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Endossonografia , Humanos , Tumores Neuroendócrinos/diagnóstico por imagem , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Prospectivos
13.
Gastrointest Endosc ; 92(3): 648-658.e2, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32433914

RESUMO

BACKGROUND AND AIMS: The aim of this study was to compare the performance of EUS-guided fine-needle biopsy using fork-tip or side-fenestrated needles in patients with solid pancreatic lesions. METHODS: A randomized controlled study was conducted in a single academic center on patients who underwent sampling with fork-tip or side-fenestrated 22-gauge or 25-gauge needles. Three passes were performed, each independently evaluated by a blinded pathologist and by endosonographers for macroscopic on-site evaluation (MOSE). The primary outcome was histologic yield; secondary aims were safety, diagnostic yield, sample quality, number of needle passes required to establish a diagnosis, and reliability of MOSE. RESULTS: One hundred ninety-two patients were enrolled. Both 22-gauge and 25-gauge fork-tip needles retrieved significantly higher rates of histologic samples than side-fenestrated needles (P < .013). Safety and diagnostic accuracy were comparable in the 2 arms, whereas sample quality (tissue integrity and blood contamination) was significantly better in the fork-tip group (P < .0001). The median number of diagnostic passes was lower using fork-tip needles (P = .054). The agreement between MOSE and pathologic evaluation was almost perfect in the fork-tip group and fair in the side-fenestrated group. CONCLUSIONS: Both needles showed equivalent safety and diagnostic accuracy. However, fork-tip needles provided a higher rate of extremely good-quality histologic samples and required fewer needle passes to reach a diagnosis. MOSE is a highly reliable tool when fork-tip needles are used compared with side-fenestrated needles. (Clinical trial registration number: NCT03622229.).


Assuntos
Agulhas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Humanos , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas , Reprodutibilidade dos Testes
14.
Endoscopy ; 52(11): 988-994, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32498099

RESUMO

BACKGROUND: Data on the reliability of the Ki-67 index and grading calculations from endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) of pancreatic neuroendocrine tumors (PanNETs) are controversial. We aimed to assess the accuracy of these data compared with histology. METHODS: Cytological analysis from EUS-FNA in patients with suspected PanNETs (n = 110) were compared with resection samples at a single institution. A minimum of 2000 cells were considered to be adequate for grading. Correlation and agreement between cytology and histology in grading and Ki-67 values, respectively, were investigated. Secondary outcomes included the diagnostic performance of EUS-FNA. RESULTS: EUS-FNA samples were adequate for PanNET diagnosis and PanNET grading in 98/110 (89.1 %) and 77/110 (70.0 %) patients, respectively; thus, 77 samples were adequate for comparing cytology vs. histology. There were 67 (62.0 %), 40 (36.4 %), and 1 (0.9 %) patients with a final diagnosis of G1, G2, and G3 tumors, respectively. EUS-FNA grading was concordant with surgical pathology in 81.8 % of patients; under- and overgrading occurred in 15.6 % and 2.6 %, respectively. The overall level of agreement for grading was moderate (Cohen's κ = 0.59, 95 % confidence interval [CI] 0.34 - 0.78). Spearman's rho for Ki-67 in tumors ≤ 20 mm and > 20 mm was strong and moderate, respectively (rho = 0.68, 95 %CI 0.47 - 0.83; rho = 0.59, 95 %CI 0.35 - 0.75). The Bland - Altman plot showed that the Ki-67 values were comparable and reproducible between the two measurements. CONCLUSIONS: Although they were not available for a significant number of patients, grading and Ki-67 values from cytology correlated with histology moderately to strongly.


Assuntos
Tumores Neuroendócrinos , Neoplasias Pancreáticas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Humanos , Antígeno Ki-67 , Gradação de Tumores , Tumores Neuroendócrinos/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
15.
Scand J Gastroenterol ; 55(9): 1108-1113, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32684051

RESUMO

INTRODUCTION: After a failed percutaneous ultrasound (US)-guided sampling, it is recommended that endoscopic ultrasound (EUS)-guided tissue acquisition (TA) be performed for non-resectable solid pancreatic lesions according to the European Federation of Societies for Ultrasound in Medicine and Biology. However, the diagnostic performance of EUS-guided TA in this setting is unknown. METHODS: We retrospectively analyzed the performance and safety of EUS-guided TA in patients with a previous failed percutaneous biopsy. We also evaluated the diagnostic delays between the percutaneous approach and EUS diagnosis. RESULTS: Over a period of 2 years, 49 patients were identified (29 males, mean age 65 years). The reasons for failure of percutaneous sampling were inadequate samples in 25 (52.1%) cases and lesions that were not visible or targetable in 24 (47.9%) cases. In one case, EUS-guided TA was not performed because of the interposition of a metallic biliary stent. No adverse events were recorded for both the percutaneous and EUS approaches. The median diagnostic delay was 12 days. Overall, the sensitivity and accuracy of EUS-guided TA were 92.7 and 93.7%, respectively. A subgroup analysis examined cases with inadequate samples obtained with the percutaneous approach, and the sensitivity and accuracy of EUS-guided TA were 85.7 and 88%, respectively. CONCLUSION: EUS-guided TA is safe and accurate for the diagnosis of pancreatic lesions after a previous inconclusive percutaneous approach.


Assuntos
Diagnóstico Tardio , Neoplasias Pancreáticas , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Humanos , Masculino , Pâncreas , Neoplasias Pancreáticas/diagnóstico por imagem , Estudos Retrospectivos
16.
Surg Endosc ; 34(6): 2796-2802, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32180000

RESUMO

BACKGROUND: Pancreatic enucleation (PE) is a viable option for the removal of non-malignant pancreatic masses leading to complete preservation of organ function. Nevertheless, PE is associated with substantial rates of post-operative pancreatic fistula (POPF), particularly when the mass is close to the main pancreatic duct (MPD). Preoperative stenting of the MPD may prevent its injury when performing PE. This paper describes a novel technique of "deep" PE preceded by endoscopic stenting of the MPD. METHODS: From January 2017 to May 2019, patients with small pancreatic neuroendocrine tumors proximal to the MPD were candidates for PE with previous stenting of the MPD at the University of Verona, Italy, and at the UCLA Medical Center, Los Angeles, California. The endoscopic stenting was scheduled either the day before or 3 weeks before surgery, depending on the participating institute. RESULTS: Ten patients were included in this pilot study. The endoscopic procedure was successful and well tolerated in all cases. Open, laparoscopic and robotic PE were performed. Seven patients had surgical complications. Among these, six developed a post-operative pancreatic fistula (POPF), but neither grade C fistulas nor disruptions of the MPD were detected. At pathology, a low grade pancreatic neuroendocrine tumor was confirmed in all cases. CONCLUSION: In the setting of high-volume centers, this procedure is safe, and it is associated with acceptable short-term surgical morbidity. The preoperative stenting of the MPD might extend the surgical indications for PE.


Assuntos
Laparoscopia/métodos , Pancreatectomia/métodos , Neoplasias Pancreáticas/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Stents , Adulto , Idoso , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Pâncreas/cirurgia , Ductos Pancreáticos/cirurgia , Fístula Pancreática/etiologia , Fístula Pancreática/prevenção & controle , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle
17.
Gastrointest Endosc ; 90(6): 933-943, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31100310

RESUMO

BACKGROUND AND AIMS: EUS-guided through-the-needle biopsy (TTNB) sampling has been reported to improve diagnostic yield compared with cytology for the evaluation of pancreatic cystic lesions (PCLs). The number of macroscopically visible tissue samples needed to reach an adequate diagnosis is still unknown. METHODS: This is a retrospective, single-center study on consecutive patients with PCLs with risk features (cyst >3 cm, thickened wall, cyst growth during follow-up, and mural nodules) who underwent TTNB sampling. The capability of differentiating mucinous versus nonmucinous cysts, ability to obtain a cyst-lining epithelium, definition of the grade of dysplasia, and specific diagnosis of cyst histotype were evaluated for 1, 2, or 3 TTNB macroscopically visible specimens. RESULTS: Sixty-one patients were evaluated. A 100% histologic adequacy was reached by 2 samples (P = .05 versus 1). Compared with cytology, 1 TTNB specimen improved the possibility of defining cyst histotype (P < .0001), whereas 2 specimens increased all 4 diagnostic categories (P < .003). Two specimens also increased diagnostic yield compared with 1 sample (P < .085). The collection of a third sample did not improve the value of any diagnostic categories. A specific diagnosis was reached in 74% of patients with 2 histologic samples. The diagnostic reliability of TTNB sampling compared with surgical histology was 90%, with a 22.9% rate of adverse events. CONCLUSIONS: Two TTNB macroscopically visible specimens reached 100% histologic adequacy and a specific diagnosis in 74% of patients. The collection of a third specimen did not add any additional information and should be avoided to possibly decrease the risk of adverse events.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Cisto Pancreático/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Instrumentos Cirúrgicos , Adulto Jovem
18.
Cytopathology ; 30(2): 179-186, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30484917

RESUMO

OBJECTIVES: Endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) is the gold standard for the diagnosis of solid pancreatic lesions (SPLs). Cytological samples can also be obtained using touch imprint cytology (TIC) on EUS fine-needle biopsy (FNB) specimens. We aimed to compare sample quality and diagnostic yield of EUS-FNA-standard cytology (EUS-FNA-SC) to that of EUS-FNB-TIC in a series of patients with SPLs. METHODS: Thirty-two consecutive patients referred for EUS-tissue acquisition of SPLs who underwent rapid on-site evaluation of both EUS-FNA-SC and paired EUS-FNB-TIC during the same endoscopic session were retrospectively identified. Sample quality (evaluated in terms of blood contamination, presence of clots, tissue casts, cellularity, and necrosis) and diagnostic yield were compared between the techniques. RESULTS: The mean number of passes to reach diagnosis at rapid on-site evaluation was similar between EUS-FNA-SC and EUS-FNB-TIC (1.09 ± 0.3 vs 1.13 ± 0.34, P = .711). EUS-FNA-SC scores of sample quality were comparable to those of EUS-FNB-TIC (blood contamination, 2.47 ± 1.11 vs 2.25 ± 1.14, P = .109; clots, 1.25 ± 0.76 vs 1.19 ± 0.69, P = .624; tissue casts, 3.56 ± 0.88 vs 3.59 ± 1.09, P = .872; cellularity, 2.84 ± 1.11 vs 3.09 ± 1.09, P = .244; necrosis, 2.25 ± 1.08 vs 2.53 ± 1.02 P = .059; total score, 12.38 ± 2.88 vs 17.66 ± 2.38, P = .536). Adequacy, sensitivity and diagnostic accuracy of the two sampling techniques were equal (93.7%, 90.6% and 90.6%, respectively). CONCLUSIONS: EUS-FNB-TIC provides comparable samples to those of EUS-FNA-SC and combines the benefits of cytology and histology for the evaluation of SPLs by employing a single needle during the same endoscopic procedure.


Assuntos
Citodiagnóstico/métodos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Adulto , Idoso , Endossonografia , Feminino , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia
19.
Hepatobiliary Pancreat Dis Int ; 17(1): 70-74, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29428108

RESUMO

BACKGROUND: Early detection of small solid pancreatic lesions is increasingly common. To date, few and contradictory data have been published about the relationship between lesion size and endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) diagnostic yield. The aim of this study was to assess the relation between the size of solid pancreatic lesions and the diagnostic yield of EUS-FNA using a 25-gauge needle in a center without available rapid on-site evaluation. METHODS: In the retrospective cohort study, we selected patients who underwent EUS-FNA for solid pancreatic lesions with a 25-gauge needle from October 2014 to October 2015. Patients were divided into three groups (≤15 mm, 16-25 mm and >25 mm), and the outcomes were compared. RESULTS: We analyzed 163 patients. Overall adequacy, sensitivity, specificity and accuracy were 85.2%, 81.8%, 93.7%, and 80.4%, respectively. When stratified by size, the sensitivity and accuracy correlated with size (P = 0.016 and P = 0.042, respectively). Multivariate analysis showed that lesion size was the only independent factor (P = 0.019, OR = 4.76) affecting accuracy. The role of size as an independent factor affecting accuracy was confirmed in a separate multivariate analysis, where size was included in the model as a covariate (P = 0.018, OR = 1.08). CONCLUSION: Our study demonstrates that, in the absence of rapid on-site evaluation, mass size affects the accuracy of EUS-FNA of solid pancreatic lesions.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Agulhas , Neoplasias Pancreáticas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Distribuição de Qui-Quadrado , Desenho de Equipamento , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Neoplasias Pancreáticas/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Carga Tumoral , Adulto Jovem
20.
Dig Endosc ; 30(6): 760-770, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29808529

RESUMO

BACKGROUND AND AIM: Tissue acquisition in pancreatic cystic lesions (PCL) is the ideal method for diagnosis and risk stratification for malignancy of these lesions. Direct sampling from the walls of PCL with different devices has shown better results than cytology from cystic fluid. We carried out a retrospective, multicenter study to evaluate the feasibility, safety, and diagnostic yield of a micro-forceps, specifically designed to be used through a 19-gauge needle after endoscopic ultrasonography (EUS)-guided puncture of PCL. METHODS: We retrospectively collected data from patients who underwent EUS-through-the-needle biopsy (EUS-TTNB) in PCL at six referral centers. RESULTS: The sampling procedure was carried out in 56 patients (mean age 57.5 ± 13.1 years, M:F 17:39), and was technically successful in all of them (100%; 95% confidence interval [CI], 94-100%). Adverse events occurred in 9/56 (16.1%; 95% CI, 8-28%) patients, with self-limited intracystic hemorrhage the most common (7/56, 12.5%; 95% CI, 5-24%). All adverse events were mild, and resolved without any specific intervention. Specimens were considered adequate for histological diagnosis in 47/56 (83.9%; 95% CI, 72-92%). In two of these patients, despite the histological adequacy, a diagnosis could not be reached. In two other cases, a specimen sufficient for a cytological diagnosis was obtained. Overall diagnostic yield by combining cytological and histological samples was 47/56 (83.9%; 95% CI, 72-92%). CONCLUSION: EUS-TTNB with micro-forceps in PCL is feasible, safe, and has a high diagnostic yield. Future prospective studies are needed to better assess the clinical impact of EUS-TTNB on the management of PCL.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Neoplasias Pancreáticas/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/efeitos adversos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA