Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Childs Nerv Syst ; 40(4): 1177-1184, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38133684

RESUMO

PURPOSE: To investigate differences in sociodemographic characteristics and short-term outcomes between patients undergoing prenatal versus postnatal myelomeningocele repair. METHODS: Patients who underwent myelomeningocele repair at our institution were stratified based on prenatal or postnatal timing of repair. Baseline characteristics and outcomes were compared. Multivariate analysis was performed to identify whether prenatal repair was a predictor of outcomes independent of socioeconomic measures. RESULTS: 49 patients underwent postnatal repair, and 30 underwent prenatal repair. Patients who underwent prenatal repair were more likely to have private insurance (73.3% vs. 42.9%, p = 0.03) and live farther from the hospital where they received their repair (251.5 ± 447.4 vs. 72.5 ± 205.6 miles, p = 0.02). Patients who underwent prenatal repair had shorter hospital stays (14.3 ± 22.7 days vs. 25.3 ± 20.1 days, p = 0.03), fewer complications (13.8% vs. 42.9%, p = 0.01), fewer 30-day ED visits (0.0% vs. 34.0%, p < 0.001), lower CSF diversion rates (13.8% vs. 38.8%, p = 0.02), and better functional status at 3-months (13.3% vs. 57.1% delayed, p = 0.009), 6-months (20.0% vs. 56.7% delayed, p = 0.03), and 1-year (29.4% vs. 70.6% delayed, p = 0.007). On multivariate analysis, prenatal repair was an independent predictor of inpatient complication (OR(95%CI): 0.19(0.05-0.75), p = 0.02) and 3-month (OR(95%CI): 0.14(0.03-0.80) p = 0.03), 6-month (OR(95%CI): 0.12(0.02-0.73), p = 0.02), and 1-year (OR(95%CI): 0.19(0.05-0.80), p = 0.02) functional status. CONCLUSION: Prenatal repair for myelomeningocele is associated with better outcomes and developmental functional status. However, patients receiving prenatal closure are more likely to have private health insurance and live farther from the hospital, suggesting potential barriers to care.


Assuntos
Hidrocefalia , Meningomielocele , Gravidez , Feminino , Humanos , Meningomielocele/cirurgia , Hidrocefalia/cirurgia , Procedimentos Neurocirúrgicos/efeitos adversos , Seguro Saúde , Fatores Socioeconômicos
2.
Neurosurg Focus ; 57(1): E14, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38950447

RESUMO

OBJECTIVE: Few large studies have investigated the factors and outcomes related to concomitant injuries occurring alongside mild traumatic brain injury (mTBI) after motor vehicle collisions (MVCs). Thus, the objective of this study was to assess whether MVC characteristics predict which patients with mTBI will have concomitant whiplash injury, and whether concomitant whiplash injury affects care utilization for these patients. METHODS: This retrospective cohort study included 22,213 patients with mTBI after MVC identified from the American College of Surgeons Trauma Quality Programs dataset. A hierarchical logistic regression model was constructed to investigate patient and MVC factors associated with concomitant whiplash injury. Propensity score matching on whiplash status, in conjunction with a multivariable logistic regression model, assessed if concomitant whiplash affected odds of hospitalization. In the subgroup of patients who were hospitalized, associations with hospital length of stay (LOS) and discharge disposition were investigated. RESULTS: The median (IQR) age was 34 (24-51) years, with a median Glasgow Coma Scale score at presentation of 15 (15-15). Patients with concomitant whiplash were older (median 36 years vs 34 years, p = 0.03) and had higher rates of hospitalization (75% vs 64%, p < 0.001). In the hierarchical model for associations with concomitant whiplash injury, patients with blood alcohol content (BAC) greater than the federal driving limit had lower odds of concomitant whiplash (OR 0.63, 95% CI 0.49-0.81) along with those who had airbag deployment (OR 0.80, 95% CI 0.68-0.95), but seatbelt use was associated with greater odds (OR 1.41, 95% CI 1.16-1.71). After matching, concomitant whiplash was independently associated with increased odds of hospitalization (OR 1.67, 95% CI 1.40-1.99) while seatbelt use was associated with decreased odds (OR 0.88, 95% CI 0.81-0.95). Among hospitalized patients, concomitant whiplash was not associated with hospital LOS or discharge disposition. CONCLUSIONS: MVC characteristics such as alcohol consumption and airbag deployment were protective toward development of concomitant whiplash for mTBI patients, while seatbelt use was associated with higher risk. Concomitant whiplash increases the odds of hospitalization for mTBI patients but does not affect hospital LOS or discharge disposition, while seatbelt use is associated with lower rates of hospitalization and a more favorable hospital course. These findings provide context to injury patterns and care provision after a common mechanism of injury.


Assuntos
Acidentes de Trânsito , Hospitalização , Traumatismos em Chicotada , Humanos , Acidentes de Trânsito/estatística & dados numéricos , Masculino , Feminino , Adulto , Traumatismos em Chicotada/epidemiologia , Traumatismos em Chicotada/complicações , Hospitalização/estatística & dados numéricos , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem , Concussão Encefálica/epidemiologia , Concussão Encefálica/complicações , Estudos de Coortes , Tempo de Internação/estatística & dados numéricos , Escala de Coma de Glasgow
3.
J Cell Sci ; 134(9)2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33973638

RESUMO

The synaptic cleft manifests enriched glycosylation, with structured glycans coordinating signaling between presynaptic and postsynaptic cells. Glycosylated signaling ligands orchestrating communication are tightly regulated by secreted glycan-binding lectins. Using the Drosophila neuromuscular junction (NMJ) as a model glutamatergic synapse, we identify a new Ca2+-binding (C-type) lectin, Lectin-galC1 (LGC1), which modulates presynaptic function and neurotransmission strength. We find that LGC1 is enriched in motoneuron presynaptic boutons and secreted into the NMJ extracellular synaptomatrix. We show that LGC1 limits locomotor peristalsis and coordinated movement speed, with a specific requirement for synaptic function, but not NMJ architecture. LGC1 controls neurotransmission strength by limiting presynaptic active zone (AZ) and postsynaptic glutamate receptor (GluR) aligned synapse number, reducing both spontaneous and stimulation-evoked synaptic vesicle (SV) release, and capping SV cycling rate. During high-frequency stimulation (HFS), mutants have faster synaptic depression and impaired recovery while replenishing depleted SV pools. Although LGC1 removal increases the number of glutamatergic synapses, we find that LGC1-null mutants exhibit decreased SV density within presynaptic boutons, particularly SV pools at presynaptic active zones. Thus, LGC1 regulates NMJ neurotransmission to modulate coordinated movement.


Assuntos
Proteínas de Drosophila , Proteínas de Drosophila/genética , Proteínas de Drosophila/metabolismo , Lectinas Tipo C , Junção Neuromuscular/metabolismo , Terminações Pré-Sinápticas/metabolismo , Sinapses/metabolismo , Transmissão Sináptica , Vesículas Sinápticas/metabolismo
4.
Childs Nerv Syst ; 39(6): 1685-1689, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36746826

RESUMO

BACKGROUND: Lipomyelomeningoceles (LMMs) are subcutaneous lipomas with dural penetration that often present with spinal cord tethering and may lead to neurological deterioration if untreated. This report describes a rare case of an LMM associated with immature nephroblastic tissue, representing a nephrogenic rest (NR) or, less likely, an immature teratoma. CLINICAL PRESENTATION: An 8-day-old infant girl presented to the clinic with a sacral dimple. Imaging demonstrated a tethered spinal cord with low-lying conus medullaris and an LMM. A firm mass was noted in the subcutaneous lipoma. Detethering surgery and removal of the lipoma and mass were performed at the age of 6 months. Pathological examination identified the mass as cartilage, fat, and immature nephroblastic tissue consistent with NR tissue or, less likely, a teratoma with renal differentiation. CONCLUSION: This presentation of an LMM associated with an immature teratoma or NR poses a risk of malignant transformation in patients. As a result, careful surgical dissection, resection, and close clinical follow-up are recommended for these patients.


Assuntos
Lipoma , Meningomielocele , Defeitos do Tubo Neural , Teratoma , Lactente , Feminino , Humanos , Meningomielocele/complicações , Meningomielocele/cirurgia , Defeitos do Tubo Neural/cirurgia , Teratoma/complicações , Teratoma/diagnóstico por imagem , Teratoma/cirurgia , Lipoma/complicações , Lipoma/diagnóstico por imagem , Lipoma/cirurgia
5.
Neurosurg Clin N Am ; 35(2): 263-272, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38423742

RESUMO

Applications and workflows around spinal robotics have evolved since these systems were first introduced in 2004. Initially approved for lumbar pedicle screw placement, the scope of robotics has expanded to instrumentation across different regions. Additionally, precise navigation can aid in tumor resection or spinal lesion ablation. Robot-assisted surgery can improve accuracy while decreasing radiation exposure, length of hospital stay, complication, and revision rates. Disadvantages include increased operative time, dependence on preoperative imaging among others. The future of robotic spine surgery includes automated surgery, telerobotic surgery, and the inclusion of machine learning or artificial intelligence in preoperative planning.


Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Inteligência Artificial , Fusão Vertebral/métodos , Coluna Vertebral/cirurgia , Robótica/métodos , Vértebras Lombares/cirurgia
6.
J Neurosurg Spine ; : 1-13, 2024 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-38968628

RESUMO

OBJECTIVE: Pedicle screw placement guidance is critical in spinal fusions, and spinal surgery robots aim to improve accuracy and reduce complications. Current literature has yet to compare the relative merits of available robotic systems. In this review, the authors aimed to 1) assess the current state of spinal robotics literature; 2) conduct a meta-analysis of robotic performance based on accuracy, speed, and safety; and 3) offer recommendations for robotic system selection. METHODS: Following PRISMA guidelines, the authors conducted a systematic literature review across PubMed, Embase, Cochrane Library, Web of Science, and Scopus as of April 28, 2022, for studies on approved robots for placing lumbar pedicle screws. Three reviewers screened and extracted data relating to the study characteristics, accuracy rate, intraoperative revisions, and reoperations. Secondary performance metrics included operative time, blood loss, and radiation exposure. The authors statistically compared the performance of the robots using a random-effects model to account for variation within and between the studies. Each robot was also compared with performance benchmarks of traditional techniques including freehand, fluoroscopic, and CT-navigated insertion. Finally, we performed a Duval and Tweedie trim-and-fill test to assess for the presence of publication bias. RESULTS: The authors identified 46 studies, describing 4670 patients and 25,054 screws, that evaluated 4 different robotic systems: Mazor X, ROSA, ExcelsiusGPS, and Cirq. The weighted accuracy rates of Gertzbein-Robbins classification grade A or B screws were as follows: ExcelsiusGPS, 98.0%; ROSA, 98.0%; Mazor, 98.2%; and Cirq, 94.2%. No robot was significantly more accurate than the others. However, the accuracy of the ExcelsiusGPS was significantly higher than that of traditional methods, and the accuracies of the Mazor and ROSA were significantly higher than that of fluoroscopy. The intraoperative revision rates were Cirq, 0.55%; ROSA, 0.91%; Mazor, 0.98%; and ExcelsiusGPS, 1.08%. The reoperation rates were Cirq, 0.28%; ExcelsiusGPS, 0.32%; and Mazor, 0.76% (no reoperations were reported for ROSA). Operative times were similar for all robots. Both the ExcelsiusGPS and Mazor were associated with significantly less blood loss than the ROSA. The Cirq had the lowest radiation exposure. Robots tended to be more accurate and generally their use was associated with fewer reoperations and less blood loss than freehand, fluoroscopic, or CT-navigated techniques. CONCLUSIONS: Robotic platforms perform comparably based on key metrics, with high accuracy rates and low intraoperative revision and reoperation rates. The spinal robotics publication rate will continue to accelerate, and choosing a robot will depend on the context of the practice.

7.
Sci Rep ; 14(1): 714, 2024 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-38184676

RESUMO

Ultrasound technology can provide high-resolution imaging of blood flow following spinal cord injury (SCI). Blood flow imaging may improve critical care management of SCI, yet its duration is limited clinically by the amount of contrast agent injection required for high-resolution, continuous monitoring. In this study, we aim to establish non-contrast ultrasound as a clinically translatable imaging technique for spinal cord blood flow via comparison to contrast-based methods and by measuring the spatial distribution of blood flow after SCI. A rodent model of contusion SCI at the T12 spinal level was carried out using three different impact forces. We compared images of spinal cord blood flow taken using both non-contrast and contrast-enhanced ultrasound. Subsequently, we processed the images as a function of distance from injury, yielding the distribution of blood flow through space after SCI, and found the following. (1) Both non-contrast and contrast-enhanced imaging methods resulted in similar blood flow distributions (Spearman's ρ = 0.55, p < 0.0001). (2) We found an area of decreased flow at the injury epicenter, or umbra (p < 0.0001). Unexpectedly, we found increased flow at the periphery, or penumbra (rostral, p < 0.05; caudal, p < 0.01), following SCI. However, distal flow remained unchanged, in what is presumably unaffected tissue. (3) Finally, tracking blood flow in the injury zones over time revealed interesting dynamic changes. After an initial decrease, blood flow in the penumbra increased during the first 10 min after injury, while blood flow in the umbra and distal tissue remained constant over time. These results demonstrate the viability of non-contrast ultrasound as a clinical monitoring tool. Furthermore, our surprising observations of increased flow in the injury periphery pose interesting new questions about how the spinal cord vasculature reacts to SCI, with potentially increased significance of the penumbra.


Assuntos
Contusões , Traumatismos da Medula Espinal , Humanos , Traumatismos da Medula Espinal/diagnóstico por imagem , Ultrassonografia , Processamento de Imagem Assistida por Computador
8.
Clin Neurol Neurosurg ; 243: 108393, 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38917745

RESUMO

OBJECTIVE: Spinal metastases can significantly affect quality of life in patients with cancer and present complex neurosurgical challenges for surgeons. Surgery with instrumentation is often indicated to alleviate pain, preserve neurological function, and ensure mechanical stability. However, distortions in the bony anatomy due to oncological disease can decrease the accuracy of pedicle screw placement. Robotic-assisted surgery may offer an opportunity to increase screw accuracy and improve navigation of spinal lesions compared to conventional techniques. Therefore, we presented our institutional experience evaluating robotic-assisted surgical fixation for spinal metastases. METHODS: Patients undergoing robotic-assisted surgery at a large tertiary care center between January 2019 - January 2023 for the treatment of spinal metastases were identified. Patient characteristics, including demographics, tumor pathology, surgical complications, and post-operative outcomes were extracted. The Gertzbein Robbins classification system (GRS) was used to assess pedicle screw placement accuracy in patients with post-operative computed tomography. RESULTS: Twenty patients were identified, including 7 females (35 %), with an overall median age of 66 years (range: 39-80 years) and median BMI of 25 kg/m2 (range: 17-34 kg/m2). An average of four spinal levels were instrumented, with metastases located primarily in the thoracic (n=17, 85 %) spine. Common primary tumor types included prostate (n=4), lung (n=2), and plasma cell (n=2) cancers. Most pedicle screws (92 %) were classified as GRS A in patients with postoperative imaging. Post-operative complications were unrelated to the use of the robot, and included pulmonary embolism (n=1), deep vein thrombosis (n=2), and gastric symptoms (n=3). Three patients were readmitted at 30 days, with one reoperation due to tumor recurrence. Four patients were deceased within 6 months of surgery. CONCLUSIONS: Despite the inherent high-risk nature of these surgeries, this study underscores the safety and efficacy of robotic-assisted surgery in the management of spinal metastases. Robots can be helpful in ensuring accuracy of pedicle screw placement in patients with metastatic disease.

9.
J Neurosurg Case Lessons ; 6(2)2023 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-37458340

RESUMO

BACKGROUND: Synthetic computed tomography (sCT) can be created from magnetic resonance imaging (MRI) utilizing newer software. sCT is yet to be explored as a possible alternative to routine CT (rCT). In this study, rCT scans and MRI-derived sCT scans were obtained on a cadaver. Morphometric analysis was performed comparing the 2 scans. The ExcelsiusGPS robot was used to place lumbosacral screws with both rCT and sCT images. OBSERVATIONS: In total, 14 screws were placed. All screws were grade A on the Gertzbein-Robbins scale. The mean surface distance difference between rCT and sCT on a reconstructed software model was -0.02 ± 0.05 mm, the mean absolute surface distance was 0.24 ± 0.05 mm, and the mean absolute error of radiodensity was 92.88 ± 10.53 HU. The overall mean tip distance for the sCT versus rCT was 1.74 ± 1.1 versus 2.36 ± 1.6 mm (p = 0.24); mean tail distance for the sCT versus rCT was 1.93 ± 0.88 versus 2.81 ± 1.03 mm (p = 0.07); and mean angular deviation for the sCT versus rCT was 3.2° ± 2.05° versus 4.04°± 2.71° (p = 0.53). LESSONS: MRI-based sCT yielded results comparable to those of rCT in both morphometric analysis and robot-assisted lumbosacral screw placement in a cadaver study.

10.
Neurosurgery ; 93(5): 994-999, 2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37255292

RESUMO

BACKGROUND AND OBJECTIVES: Flow diversion of intracranial aneurysms results in high occlusion rates. However, 10% to 20% remain persistently filling at 1 year. Often, these are retreated, but benefits of retreatment are not well established. A better understanding of the long-term rupture risk of persistently filling aneurysms after flow diversion is needed. METHODS: Our institutional database of 974 flow diversion cases was queried for persistently filling saccular aneurysms of the clinoidal, ophthalmic, and communicating segments of the internal carotid artery treated with the pipeline embolization device (PED, Medtronic). Persistent filling was defined as continued flow into the aneurysm on 1 year catheter angiogram. The clinical record was queried for retreatments and delayed ruptures. Clinical follow-up was required for at least 2 years. RESULTS: Ninety-four persistent aneurysms were identified. The average untreated aneurysm size was 5.6 mm. A branch vessel originated separately in 55% of cases from the body of the aneurysm in 10.6% of cases and from the neck in 34% of cases. Eighteen percent of aneurysms demonstrated >95% filling at 1 year, and 61% were filling 5% to 95% of their original size. The mean follow-up time was 4.9 years, including 41 cases with >5 years. No retreatment was undertaken in 91.5% of aneurysms. There were no cases of delayed subarachnoid hemorrhage. CONCLUSION: Among saccular internal carotid artery aneurysms treated with PED that demonstrated persistent aneurysm filling at 1 year, there were no instances of delayed rupture on long-term follow-up. These data suggest that observation may be appropriate for continued aneurysm filling at least in the first several years after PED placement.


Assuntos
Doenças das Artérias Carótidas , Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Seguimentos , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Angiografia Cerebral , Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Doenças das Artérias Carótidas/diagnóstico por imagem , Doenças das Artérias Carótidas/terapia
11.
J Vis Exp ; (193)2023 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-36971451

RESUMO

Low-intensity focused ultrasound (LIFU) uses ultrasonic pulsations at lower intensities than ultrasound and is being tested as a reversible and precise neuromodulatory technology. Although LIFU-mediated blood-brain barrier (BBB) opening has been explored in detail, no standardized technique for blood-spinal cord barrier (BSCB) opening has been established to date. Therefore, this protocol presents a method for successful BSCB disruption using LIFU sonication in a rat model, including descriptions of animal preparation, microbubble administration, target selection and localization, as well as BSCB disruption visualization and confirmation. The approach reported here is particularly useful for researchers who need a fast and cost-effective method to test and confirm target localization and precise BSCB disruption in a small animal model with a focused ultrasound transducer, evaluate the BSCB efficacy of sonication parameters, or explore applications for LIFU at the spinal cord, such as drug delivery, immunomodulation, and neuromodulation. Optimizing this protocol for individual use is recommended, especially for advancing future preclinical, clinical, and translational work.


Assuntos
Traumatismos da Medula Espinal , Medula Espinal , Ratos , Animais , Medula Espinal/diagnóstico por imagem , Ultrassonografia , Barreira Hematoencefálica/diagnóstico por imagem , Modelos Animais
12.
Oper Neurosurg (Hagerstown) ; 25(6): 482-488, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37578266

RESUMO

BACKGROUND AND OBJECTIVES: Robot-assisted pedicle screw placement is associated with greater accuracy, reduced radiation, less blood loss, shorter hospital stays, and fewer complications than freehand screw placement. However, it can be associated with longer operative times and an extended training period. We report the initial experience of a surgeon using a robot system at an academic medical center. METHODS: We retrospectively reviewed all patients undergoing robot-assisted pedicle screw placement at a single tertiary care institution by 1 surgeon from 10/2017 to 05/2022. Linear regression, analysis of variance, and cumulative sum analysis were used to evaluate operative time learning curves. Operative time subanalyses for surgery indication, number of levels, and experience level were performed. RESULTS: In total, 234 cases were analyzed. A significant 0.19-minute decrease in operative time per case was observed (r = 0.14, P = .03). After 234 operations, this translates to a reduction in 44.5 minutes from the first to last case. A linear relationship was observed between case number and operative time in patients with spondylolisthesis (-0.63 minutes/case, r = 0.41, P < .001), 2-level involvement (-0.35 minutes/case, r = 0.19, P = .05), and 4-or-more-level involvement (-1.29 minutes/case, r = 0.24, P = .05). This resulted in reductions in operative time ranging from 39 minutes to 1.5 hours. Continued reductions in operative time were observed across the learning, experienced, and expert phases, which had mean operative times of 214, 197, and 146 minutes, respectively ( P < .001). General proficiency in robot-assisted surgery was observed after the 20th case. However, 67 cases were required to reach mastery, defined as the inflection point of the cumulative sum curve. CONCLUSION: This study documents the long-term learning curve of a fellowship-trained spine neurosurgeon. Operative time significantly decreased with more experience. Although gaining comfort with robotic systems may be challenging or require additional training, it can benefit surgeons and patients alike with continued reductions in operative time.


Assuntos
Parafusos Pediculares , Robótica , Humanos , Curva de Aprendizado , Duração da Cirurgia , Estudos Retrospectivos
13.
IEEE Trans Biomed Eng ; 70(7): 1992-2001, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37018313

RESUMO

OBJECTIVE: Here we investigate the ability of low-intensity ultrasound (LIUS) applied to the spinal cord to modulate the transmission of motor signals. METHODS: Male adult Sprague-Dawley rats (n = 10, 250-300 g, 15 weeks old) were used in this study. Anesthesia was initially induced with 2% isoflurane carried by oxygen at 4 L/min via a nose cone. Cranial, upper extremity, and lower extremity electrodes were placed. A thoracic laminectomy was performed to expose the spinal cord at the T11 and T12 vertebral levels. A LIUS transducer was coupled to the exposed spinal cord, and motor evoked potentials (MEPs) were acquired each minute for either 5- or 10-minutes of sonication. Following the sonication period, the ultrasound was turned off and post-sonication MEPs were acquired for an additional 5 minutes. RESULTS: Hindlimb MEP amplitude significantly decreased during sonication in both the 5- (p < 0.001) and 10-min (p = 0.004) cohorts with a corresponding gradual recovery to baseline. Forelimb MEP amplitude did not demonstrate any statistically significant changes during sonication in either the 5- (p = 0.46) or 10-min (p = 0.80) trials. CONCLUSION: LIUS applied to the spinal cord suppresses MEP signals caudal to the site of sonication, with recovery of MEPs to baseline after sonication. SIGNIFICANCE: LIUS can suppress motor signals in the spinal cord and may be useful in treating movement disorders driven by excessive excitation of spinal neurons.


Assuntos
Potencial Evocado Motor , Traumatismos da Medula Espinal , Ratos , Animais , Masculino , Potencial Evocado Motor/fisiologia , Ratos Sprague-Dawley , Medula Espinal/fisiologia , Coluna Vertebral , Potenciais Evocados
14.
Cancers (Basel) ; 14(19)2022 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-36230843

RESUMO

Glioblastoma (GBM) is an aggressive primary astrocytoma associated with short overall survival. Treatment for GBM primarily consists of maximal safe surgical resection, radiation therapy, and chemotherapy using temozolomide. Nonetheless, recurrence and tumor progression is the norm, driven by tumor stem cell activity and a high mutational burden. Focused ultrasound (FUS) has shown promising results in preclinical and clinical trials for treatment of GBM and has received regulatory approval for the treatment of other neoplasms. Here, we review the range of applications for FUS in the treatment of GBM, which depend on parameters, including frequency, power, pulse duration, and duty cycle. Low-intensity FUS can be used to transiently open the blood-brain barrier (BBB), which restricts diffusion of most macromolecules and therapeutic agents into the brain. Under guidance from magnetic resonance imaging, the BBB can be targeted in a precise location to permit diffusion of molecules only at the vicinity of the tumor, preventing side effects to healthy tissue. BBB opening can also be used to improve detection of cell-free tumor DNA with liquid biopsies, allowing non-invasive diagnosis and identification of molecular mutations. High-intensity FUS can cause tumor ablation via a hyperthermic effect. Additionally, FUS can stimulate immunological attack of tumor cells, can activate sonosensitizers to exert cytotoxic effects on tumor tissue, and can sensitize tumors to radiation therapy. Finally, another mechanism under investigation, known as histotripsy, produces tumor ablation via acoustic cavitation rather than thermal effects.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA