Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 127(2): 025002, 2021 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-34296928

RESUMO

The key result of the present work is the theoretical prediction and observation of the formation of a new type of transport barrier in fusion plasmas, called F-ATB (fast ion-induced anomalous transport barrier). As demonstrated through state-of-the-art global electrostatic and electromagnetic simulations, the F-ATB is characterized by a full suppression of the turbulent transport-caused by strongly sheared, axisymmetric E×B flows-and an increase of the neoclassical counterpart, albeit keeping the overall fluxes at significantly reduced levels. The trigger mechanism is shown to be a mainly electrostatic resonant interaction between suprathermal particles, generated via ion-cyclotron-resonance heating, and plasma microturbulence. These findings are obtained by realistic simulations of the ASDEX Upgrade discharge No. 36637-properly designed to maximized the beneficial role of the wave-particle resonance interaction-which exhibits the expected properties of improved confinement produced by energetic particles.

2.
Artigo em Russo | MEDLINE | ID: mdl-35904293

RESUMO

AIM OF THE STUDY: To investigate the efficacy and safety of non-immunogenic staphylokinase (NS) compared with alteplase (A) in patients with acute ischemic stroke (AIS) within 4.5 h after symptom onset. MATERIAL AND METHODS: 336 patients with IS within 4.5 h after symptom onset were included in a randomized, open-label, multicenter, parallel-group, non-inferiority comparative trial of NS vs A (168 patients in each group). NS was administered as an intravenous bolus in a dose of 10 mg, regardless of body weight, over 10 s, A was administered as a bolus infusion in a dose of 0.9 mg/kg, maximum 90 mg over 1 hour. The primary efficacy endpoint was a favorable outcome, defined as a modified Rankin scale (mRS) score of 0-1 on day 90. Safety endpoints included all-cause mortality on day 90, symptomatic intracranial haemorrhage, and other serious adverse events (SAEs). RESULTS: At day 90, 84 (50%) patients reached the primary endpoint (mRS 0-1) in the NS group, 68 (41%) patients - in the A group (p=0.10, OR=1.47, 95% CI=0.93-2.32). The difference between groups NS and A was 9.5% (95% CI= -1.7-20.7) and the lower limit of the 95% CI did not cross the margin of non-inferiority (pnon-inferiority<0.0001). There were no significant differences in the frequency of deaths between the groups: on day 90, 17 (10%) patients in the NS group and 24 (14%) in the A group had died (p=0.32). There was a trend towards significant differences in the frequency of symptomatic intracranial haemorrhage: NS group - 5 (3%) patients, A group - 13 (8%) patients (p=0.087, OR=0.37, 95% CI=0.1-1.13). There were significant differences in the number of patients with SAEs: in the NS group - 22 (13%) patients, in the A group - 37 (22%) patients (p=0.044, OR=0.53, 95% CI=0.28-0.98). CONCLUSION: The presented results of the FRIDA trial are the first in the world to use a drug based on NS in patients with IS. It has been shown that a single bolus (within 10 s) administration of NS at a standard dose of 10 mg, regardless of body weight, allows to conduct fast, effective and safe thrombolytic therapy in patients with IS within 4.5 h after symptom onset. In further clinical tials of NS, it is planned to expand the therapeutic window beyond 4.5 h after symptom onset in patients with IS.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Metaloendopeptidases , Acidente Vascular Cerebral , Peso Corporal , Isquemia Encefálica/complicações , Isquemia Encefálica/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Humanos , Hemorragias Intracranianas/induzido quimicamente , Hemorragias Intracranianas/complicações , Metaloendopeptidases/uso terapêutico , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/etiologia , Terapia Trombolítica , Resultado do Tratamento
3.
Her Russ Acad Sci ; 91(4): 473-481, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34539150

RESUMO

The results of assessing the housing provision of the rural and urban populations of Russia are presented. On the basis of the author's methodology for identifying the level of housing provision, its actual characteristics were compared with social standards, that is, regulatory requirements for area, spaciousness, and comfort of a house or apartment. It is shown that in the city, in contrast to the countryside, housing conditions are characterized by a higher level of comforts but, at the same time, more constrained living conditions (in terms of the area of the dwelling and its spaciousness). The groups of the rural and urban populations differing in terms of housing provision have been identified. It was revealed that the share of rural residents living in housing poverty (in terms of area and living conditions) is more than two times higher (87.8%) than in the country as a whole (41.6%) and more than three times higher than residents of cities (25.1%). Ways to solve this problem are suggested.

4.
Rev Sci Instrum ; 92(3): 033546, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820048

RESUMO

An ion cyclotron emission (ICE) diagnostic is prepared for installation into the W7-X stellarator, with the aim to be operated in the 2022 experimental campaign. The design is based on the successful ICE diagnostic on the ASDEX Upgrade tokamak. The new diagnostic consists of four B-dot probes, mounted about 72° toroidally away (one module) from the neutral beam injector, with an unobstructed plasma view. Two of the B-dot probes are oriented parallel to the local magnetic field, aimed to detect fast magnetosonic waves. The remaining two probes are oriented poloidally, with the aim to detect slow waves. The radio frequency (RF) signals picked up by the probes are transferred via 50 Ω vacuum-compatible coaxial cables to RF detectors. Narrow band notch filters are used to protect the detectors from possible RF waves launched by the W7-X antenna. The signal will be sampled with a four-channel fast analog-to-digital converter with 14 bit depth and 1 GSample/s sampling rate. The diagnostic's phase-frequency characteristic is properly measured in order to allow measuring the wave vectors of the picked up waves.

5.
Phys Rev Lett ; 105(16): 165001, 2010 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-21230980

RESUMO

Turbulence properties in the scrape-off layer (SOL) in the presence of ion cyclotron frequency heating (ICRH) are compared to instances where it is absent. The discharges are all in a high-confinement mode (H-mode) regime. During ICRH, the SOL plasma density increases whereas turbulence large-scale and convective structures are shown to be suppressed. The probability distribution function is thus recorded to be closer to a Gaussian, and a net decrease in the low-frequency density fluctuations is reflected in the power spectra. Consequently, the level of turbulent fluctuations decreases significantly. Turbulence suppression is also reported during edge localized modes (ELMs) where both the ELMs-induced transport and duration are strongly affected. The increase of neutrals by gas puffing did not alter this behavior. We deduce that ICRH can be used as to suppress convective transport and reduce the ELM's amplitude.

6.
Phys Rev Lett ; 104(18): 185002, 2010 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-20482185

RESUMO

We present here the first phase-space characterization of convective and diffusive energetic particle losses induced by shear Alfvén waves in a magnetically confined fusion plasma. While single toroidal Alfvén eigenmodes (TAE) and Alfvén cascades (AC) eject resonant fast ions in a convective process, an overlapping of AC and TAE spatial structures leads to a large fast-ion diffusion and loss. Diffusive fast-ion losses have been observed with a single TAE above a certain threshold in the fluctuation amplitude.

7.
Rev Sci Instrum ; 91(6): 063506, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32611035

RESUMO

This manuscript presents a new method of interpreting the ion temperature (Ti) measurement with a retarding field analyzer (RFA) that accounts for the intermittent/turbulent nature of the scrape off layer (SOL) plasmas in tokamaks. Fast measurements and statistical methods are desirable for an adequate description of random fluctuations caused by such intermittent events as edge localized modes (ELMs) and blobs. We use a RFA that can sweep its current-voltage (I-V) characteristics with up to 10 kHz. The RFA uses an electronics compensation stage to subtract the capacitive pickup due to the finite connecting cable capacitance, which greatly improves the signal-to-noise ratio. In the 10 kHz case, a single I-V characteristic is obtained in time, which is an order of magnitude faster than the ELM cycle. The fast sweeping frequency allows us to reconstruct the Ti probability density function (PDF), which we use as the Ti representation. The boundary conditions that we place on the I-V characteristics when calculating the Ti values impact the resulting Ti PDF. If the boundaries are insensitive to the plasma fluctuations, then the most probable Ti value of the PDF (20 eV-25 eV) is similar to the Ti value obtained via the classical conditional averaging method (20 eV-27 eV). However, if the boundary conditions follow the fluctuations, then the PDF-based method gives a substantially higher most probable Ti value (35 eV-60 eV). Overall, we show that a fast sweeping RFA diagnostic should be used in intermittent SOL plasmas to reconstruct the PDF for accurate Ti measurements.

8.
Rev Sci Instrum ; 89(10): 10J101, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399687

RESUMO

The B-dot probe diagnostic suite on the ASDEX Upgrade tokamak has recently been upgraded with a new 125 MHz, 14 bit resolution digitizer to study ion cyclotron emission (ICE). While classic edge emission from the low field side plasma is often observed, we also measure waves originating from the core with fast fusion protons or beam injected deuterons being a possible emission driver. Comparing the measured frequency values with ion cyclotron harmonics present in the plasma places the origin of this emission on the magnetic axis, with the fundamental hydrogen/second deuterium cyclotron harmonic matching the observed values. The actual values range from ∼27 MHz at the on-axis toroidal field BT = -1.79 T to ∼40 MHz at BT = -2.62 T. When the magnetic axis position evolves during this emission, the measured frequency values track the changes in the estimated on-axis cyclotron frequency values. Core ICE is usually a transient event lasting ∼100 ms during the neutral beam startup phase. However, in some cases, core emission occurs in steady-state plasmas and lasts for longer than 1 s. These observations suggest an attractive possibility of using a non-perturbing ICE-based diagnostic to passively monitor fusion alpha particles at the location of their birth in the plasma core, in deuterium-tritium burning devices such as ITER and DEMO.

9.
Khirurgiia (Mosk) ; (3): 44-8, 2007.
Artigo em Russo | MEDLINE | ID: mdl-17495842

RESUMO

One hundred and four patients with atherosclerotic lesion of femoro-popliteal segment and III-IV stage of ischemia underwent vascular surgical procedures. Results of these operations were analyzed depending on state of distal arterial bed. Autovenous femoro-popliteal bypass (FPB) with reversed autovein was performed at 49 (47.1%) patients, femoro-tibial bypass (FTB) with autovein in situ - at 55 (52.9%). Clinical and angiographic variants of favorable and unfavorable prognosis of FBP and FTB are described. It is demonstrated that severe lesion of outflow distal arteries is the main cause of bypasses thrombosis. Protective arteriovenous fistula in the region of FTB distal anastomosis improves significantly short-term results of operation.


Assuntos
Arteriopatias Oclusivas , Aterosclerose , Isquemia , Extremidade Inferior/irrigação sanguínea , Extremidade Inferior/fisiopatologia , Procedimentos de Cirurgia Plástica/métodos , Arteriopatias Oclusivas/etiologia , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/cirurgia , Aterosclerose/complicações , Aterosclerose/fisiopatologia , Aterosclerose/cirurgia , Humanos , Isquemia/etiologia , Isquemia/fisiopatologia , Isquemia/cirurgia , Índice de Gravidade de Doença
10.
Vestn Khir Im I I Grek ; 166(4): 16-9, 2007.
Artigo em Russo | MEDLINE | ID: mdl-17966648

RESUMO

Causes of early shunt thromboses were studied retrospectively in 35 patients with occlusion of the femoro-popliteal segment and critical ischemia, in whom the operation of distal femoro-tibial shunt with the autovein had been performed by the method in situ without an application of the arteio-venous fistula (AVF). Early thromboses of the shunts took place in 8 patients (22.9%). The main cause of the early thromboses of the femorotibial shunts was shown to be a critical occlusive-stenotic lesion of the main arteries of the shin and foot with dysfunction of the plantar arch as well as decompensation of the microcirculation system. Objective criteria of the formation of AVF were worked out. The application of the criteria in operative treatment of 25 patients allowed the number of early thromboses to be reduced to 4%.


Assuntos
Fístula Arteriovenosa , Aterosclerose/complicações , Aterosclerose/cirurgia , Artéria Femoral/cirurgia , Isquemia/cirurgia , Artéria Poplítea/cirurgia , Artérias da Tíbia/cirurgia , Procedimentos Cirúrgicos Vasculares/métodos , Arteriopatias Oclusivas/patologia , Arteriopatias Oclusivas/cirurgia , Aterosclerose/patologia , Artéria Femoral/patologia , Humanos , Isquemia/patologia , Masculino , Pessoa de Meia-Idade , Artéria Poplítea/patologia , Cuidados Pré-Operatórios , Artérias da Tíbia/patologia
11.
Rev Sci Instrum ; 87(11): 11D301, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910344

RESUMO

A new array of B-dot probes was installed on ASDEX Upgrade. The purpose of the new diagnostic is to study Ion Cyclotron Range-off Frequencies (ICRF) wave field distributions in the evanescent scrape-off layer (SOL) plasma region on the low field side of ASDEX Upgrade. The vacuum measurements (no gas, BT = 0 T) reveal ICRF wave field measurements consistent with the profiles expected from the newly installed 3-strap ICRF antennas outside the antenna box: the shape of the toroidal distribution of both the amplitude and the phase is the same for the case of only the central straps being active, as for the case of only the side straps being active. These profiles become strongly modified during plasma operations. The modifications can be separated into two types: "Inter-edge localized mode (ELM)" and "During-ELM" periods. The phase distribution of the ICRF wave fields remains well-defined during the Inter-ELM period; however, it becomes more spread out over the entire 360° range during ELMs. The observed modulations cannot be explained by the observed changes in the ICRF power, as monitored in the transmission line. However, they are consistent with ICRF coupling changes introduced by plasma filaments: the plasma density perturbations due to the filaments are high enough to change the nature of the fast ICRF wave field from evanescent to propagating. The coverage of the present diagnostic is being expanded to include both the low field side and the high field side probes. Additionally, a manipulator probe head is being developed to measure ICRF wave field radial profiles across the SOL region.

12.
Rev Sci Instrum ; 87(11): 11E722, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910673

RESUMO

A new multichannel frequency modulated continuous-wave reflectometry diagnostic has been successfully installed and commissioned on ASDEX Upgrade to measure the plasma edge electron density profile evolution in front of the Ion Cyclotron Range of Frequencies (ICRF) antenna. The design of the new three-strap ICRF antenna integrates ten pairs (sending and receiving) of microwave reflectometry antennas. The multichannel reflectometer can use three of these to measure the edge electron density profiles up to 2 × 1019 m-3, at different poloidal locations, allowing the direct study of the local plasma layers in front of the ICRF antenna. ICRF power coupling, operational effects, and poloidal variations of the plasma density profile can be consistently studied for the first time. In this work the diagnostic hardware architecture is described and the obtained density profile measurements were used to track outer radial plasma position and plasma shape.

13.
Rev Sci Instrum ; 86(11): 115112, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26628177

RESUMO

A new B-dot probe-based diagnostic has been installed on an ASDEX Upgrade tokamak to characterize ion cyclotron range-of frequency (ICRF) wave generation and interaction with magnetized plasma. The diagnostic consists of a field-aligned array of B-dot probes, oriented to measure fast and slow ICRF wave fields and their field-aligned wavenumber (k(//)) spectrum on the low field side of ASDEX Upgrade. A thorough description of the diagnostic and the supporting electronics is provided. In order to compare the measured dominant wavenumber of the local ICRF fields with the expected spectrum of the launched ICRF waves, in-air near-field measurements were performed on the newly installed 3-strap ICRF antenna to reconstruct the dominant launched toroidal wavenumbers (k(tor)). Measurements during a strap current phasing scan in tokamak discharges reveal an upshift in k(//) as strap phasing is moved away from the dipole configuration. This result is the opposite of the k(tor) trend expected from in-air near-field measurements; however, the near-field based reconstruction routine does not account for the effect of induced radiofrequency (RF) currents in the passive antenna structures. The measured exponential increase in the local ICRF wave field amplitude is in agreement with the upshifted k(//), as strap phasing moves away from the dipole configuration. An examination of discharges heated with two ICRF antennas simultaneously reveals the existence of beat waves at 1 kHz, as expected from the difference of the two antennas' operating frequencies. Beats are observed on both the fast and the slow wave probes suggesting that the two waves are coupled outside the active antennas. Although the new diagnostic shows consistent trends between the amplitude and the phase measurements in response to changes applied by the ICRF antennas, the disagreement with the in-air near-field measurements remains. An electromagnetic model is currently under development to address this issue.

15.
Kardiologiia ; 23(6): 99-102, 1983 Jun.
Artigo em Russo | MEDLINE | ID: mdl-6887691

RESUMO

Possibilities of two-dimensional echocardiography using a number of additional cross-sections (right chambers sectioned longitudinally, four-chamber epigastric view, longitudinal cross-section of aortal arc) have been investigated. Heart structures were identified on the basis of comparisons with anatomical cross-sections of the heart in the preset planes. The study is based on sections from 34 hearts and findings of 46 echocardiographic investigations in normal subjects. Some methodological procedures for obtaining such echocardiograms are specified.


Assuntos
Ecocardiografia/métodos , Coração/anatomia & histologia , Adolescente , Adulto , Aorta Torácica/anatomia & histologia , Aneurisma Aórtico/diagnóstico , Coartação Aórtica/diagnóstico , Humanos , Pessoa de Meia-Idade
16.
Arkh Patol ; 55(6): 48-54, 1993.
Artigo em Russo | MEDLINE | ID: mdl-8122977

RESUMO

96 placentas from mothers with genital mycoplasmosis diagnosed during the pregnancy (main group), and without mycoplasmosis (group for comparison) were studied. Histological study was performed in parallel with electron microscopy of the amnion and use of fluorescent antibodies. Progression of the involutive-degenerative changes in the placenta with the development of lipophanerosis and destruction of the extra-placental amnion epithelium were observed in the main group in parallel with the increase of the immunoglobulins studied (A, M, G), fibrinogen, C3-component of the complement with fixation of pathogenic immune complexes (IC). IC are observed in the placenta of 51 +/- 6.35% and in the extra-placental coats in 100% of mothers with mycoplasmosis versus 9 +/- 4.91% and 40%, respectively, in the comparison group. The presence of IC in the placenta and extra-placental coats correlates with the neurological symptoms in newborns and the increase of infectious-allergic diseases in children of the 1st year of life.


Assuntos
Doenças dos Genitais Femininos/patologia , Infecções por Mycoplasma/patologia , Placenta/patologia , Complicações Infecciosas na Gravidez/patologia , Complexo Antígeno-Anticorpo/análise , Feminino , Humanos , Imunoglobulinas/análise , Gravidez
17.
Kardiologiia ; 20(10): 93-5, 1980 Oct.
Artigo em Russo | MEDLINE | ID: mdl-7441968

RESUMO

The object of the work was to disclose the possibilities of bimetric echocardiography in appraising the mobility of the mitral valve cusps in patients with mitral stenosis. The shape of the mitral cusp movement was studied in the longitudinal and transverse planes of the heart section. The results of the ultrasonic examinations were compared with the operative findings in 68 patients operated on for mitral stenosis. In satisfactory mobility of the valve, "sail-shaping" of the cusps is recorded in the longitudinal plane of the heart section and a concavity in the transverse plane in the period of diastole. In coarse fibrosis of the cusps, the diastolic movement of the surface of the anterior cusp is recorded as a displacement of a straight line which moves parallel to its initial position in the period of systole. Bimetric echocardiography makes it possible to determine exactly the character of the mitral valve lesion and determine the degree of mobility of the cusps in patients with mitral stenosis. This information may be decisive in choosing the method of surgical correction of the disease.


Assuntos
Ecocardiografia/métodos , Estenose da Valva Mitral/diagnóstico , Valva Mitral/fisiopatologia , Adolescente , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia
18.
Kardiologiia ; 20(3): 32-5, 1980 Mar.
Artigo em Russo | MEDLINE | ID: mdl-7373986

RESUMO

Contrast echocardiography was applied in the examination of 38 patients with various congenital and acquired heart diseases. The dye cardiogreen and physiological saline solution were used as the contrast medium. The technique of contrast echocardiography is described. It is shown that the method of contrast echocardiography allows one to visualize the direction in which the intracardiac streams of blood move, which makes it possible to use the method in the diagnosis of septal defects and cardiac valve insufficiency.


Assuntos
Meios de Contraste/administração & dosagem , Ecocardiografia/métodos , Verde de Indocianina/administração & dosagem , Adolescente , Adulto , Cateterismo Cardíaco , Criança , Avaliação de Medicamentos , Cardiopatias Congênitas/diagnóstico , Cardiopatias/diagnóstico , Humanos , Pessoa de Meia-Idade , Fatores de Tempo
19.
Kardiologiia ; 25(3): 68-70, 1985 Mar.
Artigo em Russo | MEDLINE | ID: mdl-3999532

RESUMO

Echocardiographic signs of subvalvular fusions are discussed, as they frequently complicate the course of mitral stenosis. The diagnostic value of two-dimensional echo-cardiography is established for this abnormality. Subvalvular fusions of the chordal apparatus are shown to be associated with certain signs on the two-dimensional echocardiogram, such as additional echoes under mitral valve cusps in short-axis heart section (sensitivity 67.2%, specificity 90.7%), and mitral orifice drawn towards the interventricular septum (sensitivity 35.7%, specificity 93.5%), thickened subvalvular structures in the long-axis section of the heart's left compartments (sensitivity 40.7%, specificity 82.9%), and fissural or "coma-like" shape of the mitral orifice.


Assuntos
Ecocardiografia , Estenose da Valva Mitral/diagnóstico , Valva Mitral/patologia , Adulto , Feminino , Humanos , Masculino , Estenose da Valva Mitral/complicações , Aderências Teciduais/diagnóstico
20.
Kardiologiia ; 25(4): 28-32, 1985 Apr.
Artigo em Russo | MEDLINE | ID: mdl-4021270

RESUMO

A study of the clinical pattern and findings of auxiliary investigation in 27 patients with dissecting aneurysms of the thoracic aorta showed that early diagnosis was necessary to improve the results of the treatment. A new non-invasive diagnostic method, computerized tomography, was employed for the first time in domestic clinical practice. The diagnostic value of various instrumental investigation techniques was demonstrated with respect to research and clinical work.


Assuntos
Aneurisma Aórtico/diagnóstico , Dissecção Aórtica/diagnóstico , Adulto , Idoso , Aorta , Aorta Torácica/diagnóstico por imagem , Ruptura Aórtica/diagnóstico , Aortografia/métodos , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA