Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Eur Respir J ; 58(5)2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34049948

RESUMO

BACKGROUND: Bringing reliable and accurate tuberculosis (TB) diagnosis closer to patients is a key priority for global TB control. Molbio Diagnostics have developed the Truenat point-of-care molecular assays for detection of TB and rifampicin (RIF) resistance. METHODS: We conducted a prospective multicentre diagnostic accuracy study at 19 primary healthcare centres and seven reference laboratories in Peru, India, Ethiopia and Papua New Guinea to estimate the diagnostic accuracy of the point-of-care Truenat MTB, MTB Plus and MTB-RIF Dx assays for pulmonary TB using culture and phenotypic drug susceptibility testing as the reference standard, compared with Xpert MTB/RIF or Ultra. RESULTS: Of 1807 enrolled participants with TB signs/symptoms, 24% were culture-positive for Mycobacterium tuberculosis, of which 15% were RIF-resistant. In microscopy centres, the pooled sensitivity of Truenat MTB and Truenat MTB Plus was 73% (95% CI 67-78%) and 80% (95% CI 75-84%), respectively. Among smear-negative specimens, sensitivities were 36% (95% CI 27-47%) and 47% (95% CI 37-58%), respectively. Sensitivity of Truenat MTB-RIF was 84% (95% CI 62-95%). Truenat assays showed high specificity. Head-to-head comparison in the central reference laboratories suggested that the Truenat assays have similar performance to Xpert MTB/RIF. CONCLUSION: We found the performance of Molbio's Truenat MTB, MTB Plus and MTB-RIF Dx assays to be comparable to that of the Xpert MTB/RIF assay. Performing the Truenat tests in primary healthcare centres with very limited infrastructure was feasible. These data supported the development of a World Health Organization policy recommendation of the Molbio assays.


Assuntos
Antibióticos Antituberculose , Mycobacterium tuberculosis , Tuberculose , Antibióticos Antituberculose/uso terapêutico , Farmacorresistência Bacteriana , Humanos , Testes de Sensibilidade Microbiana , Estudos Prospectivos , Sensibilidade e Especificidade , Escarro , Tuberculose/diagnóstico , Tuberculose/tratamento farmacológico
2.
Lancet ; 390(10108): 2211-2214, 2017 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-28577861

RESUMO

Diagnostics are crucial in mitigating the effect of disease outbreaks. Because diagnostic development and validation are time consuming, they should be carried out in anticipation of epidemics rather than in response to them. The diagnostic response to the 2014-15 Ebola epidemic, although ultimately effective, was slow and expensive. If a focused mechanism had existed with the technical and financial resources to drive its development ahead of the outbreak, point-of-care Ebola tests supporting a less costly and more mobile response could have been available early on in the diagnosis process. A new partnering model could drive rapid development of tests and surveillance strategies for novel pathogens that emerge in future outbreaks. We look at lessons learned from the Ebola outbreak and propose specific solutions to improve the speed of new assay development and ensure their effective deployment.


Assuntos
Defesa Civil/organização & administração , Controle de Doenças Transmissíveis/métodos , Surtos de Doenças , Ebolavirus/isolamento & purificação , Doença pelo Vírus Ebola/diagnóstico , Doença pelo Vírus Ebola/epidemiologia , Erradicação de Doenças/métodos , Feminino , Saúde Global , Doença pelo Vírus Ebola/terapia , Humanos , Masculino , Testes Imediatos , Desenvolvimento de Programas , Avaliação de Programas e Projetos de Saúde , Organização Mundial da Saúde
3.
Eur Respir J ; 52(4)2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30139776

RESUMO

Novel accurate tests are needed that identify individuals infected with Mycobacterium tuberculosis who have incipient disease and are likely to develop clinical tuberculosis (TB) in the near future to allow for targeted preventive treatment beyond the current risk groups. Recently, a target product profile was developed that outlines the minimal and optimal characteristics for such an incipient TB test. We describe an evaluation framework for generating evidence to inform the development of policy guidance for the use of such a new test by the World Health Organization. Two research objectives are addressed. 1) The predictive ability of an incipient TB test should be assessed in clinical evaluation studies that include the intended target population and follow-up of sufficient duration to observe whether individuals do or do not progress to clinical TB disease. 2) Studies are needed to evaluate the test under routine programmatic conditions and measure its impact on patient- or health-system-important outcomes. For both research objectives, study designs, methods and analysis are described, with the intent to inform the clinical development plans of test manufacturers, researchers and funders.


Assuntos
Progressão da Doença , Estudos de Avaliação como Assunto , Valor Preditivo dos Testes , Tuberculose/diagnóstico , Guias como Assunto , Humanos , Tuberculose Latente/diagnóstico , Mycobacterium tuberculosis , Tuberculose/prevenção & controle , Organização Mundial da Saúde
5.
Eur Respir J ; 48(2): 516-25, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27418550

RESUMO

The global roll-out of Xpert MTB/RIF (Cepheid Inc., Sunnyvale, CA, USA) has changed the diagnostic landscape of tuberculosis (TB). More than 16 million tests have been performed in 122 countries since 2011, and detection of multidrug-resistant TB has increased three- to eight-fold compared to conventional testing. The roll-out has galvanised stakeholders, from donors to civil society, and paved the way for universal drug susceptibility testing. It has attracted new product developers to TB, resulting in a robust molecular diagnostics pipeline. However, the roll-out has also highlighted gaps that have constrained scale-up and limited impact on patient outcomes. The roll-out has been hampered by high costs for under-funded programmes, unavailability of a complete solution package (notably comprehensive training, quality assurance, implementation plans, inadequate service and maintenance support) and lack of impact assessment. Insufficient focus has been afforded to effective linkage to care of diagnosed patients, and clinical impact has been blunted by weak health systems. In many countries the private sector plays a dominant role in TB control, yet this sector has limited access to subsidised pricing. In light of these lessons, we advocate for a comprehensive diagnostics implementation approach, including increased engagement of in-country stakeholders for product launch and roll-out, broader systems strengthening in preparation for new technologies, as well as quality impact data from programmatic settings.


Assuntos
Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Tuberculose Pulmonar/diagnóstico , Antibióticos Antituberculose/uso terapêutico , Controle de Doenças Transmissíveis , Farmacorresistência Bacteriana , Saúde Global , Custos de Cuidados de Saúde , Política de Saúde , Humanos , Mycobacterium tuberculosis/efeitos dos fármacos , Testes Imediatos , Setor Privado , Garantia da Qualidade dos Cuidados de Saúde , Rifampina/uso terapêutico , Escarro/efeitos dos fármacos , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico , Tuberculose Resistente a Múltiplos Medicamentos/prevenção & controle , Tuberculose Pulmonar/tratamento farmacológico , Tuberculose Pulmonar/prevenção & controle
6.
J Clin Microbiol ; 54(6): 1624-1630, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27076658

RESUMO

Less than 30% of multidrug-resistant tuberculosis (MDR-TB) patients are currently diagnosed, due to laboratory constraints. Molecular diagnostics enable rapid and simplified diagnosis. Newer-version line probe assays have not been evaluated against the WHO-endorsed Hain GenoType MTBDRplus (referred to as Hain version 1 [V1]) for the rapid detection of rifampin (RIF) and isoniazid (INH) resistance. A two-phase noninferiority study was conducted in two supranational reference laboratories to allow head-to-head comparisons of two new tests, Hain Genotype MTBDRplus version 2 (referred to as Hain version 2 [V2]) and Nipro NTM+MDRTB detection kit 2 (referred to as Nipro), to Hain V1. In phase 1, the results for 379 test strains were compared to a composite reference standard that used phenotypic drug susceptibility testing (DST) and targeted sequencing. In phase 2, the results for 644 sputum samples were compared to a phenotypic DST reference standard alone. Using a challenging set of strains in phase 1, the values for sensitivity and specificity for Hain V1, Hain V2, and Nipro, respectively, were 90.3%/98.5%, 90.3%/98.5%, and 92.0%/98.5% for RIF resistance detection and 89.1%/99.4%, 89.1%/99.4%, and 89.6%/100.0% for INH resistance detection. Testing of sputa in phase 2 yielded values for sensitivity and specificity of 97.1%/97.1%, 98.2%/97.8%, and 96.5%/97.5% for RIF and 94.4%/96.4%, 95.4%/98.8%, and 94.9%/97.6% for INH. Overall, the rates of indeterminate results were low, but there was a higher rate of indeterminate results with Nipro than with Hain V1 and V2 in samples with low smear grades. Noninferiority of Hain V2 and Nipro to Hain V1 was demonstrated for RIF and INH resistance detection in isolates and sputum specimens. These results serve as evidence for WHO policy recommendations on the use of line probe assays, including the Hain V2 and Nipro assays, for MDR-TB detection.


Assuntos
Farmacorresistência Bacteriana , Técnicas de Genotipagem/métodos , Testes de Sensibilidade Microbiana/métodos , Mycobacterium tuberculosis/genética , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Antituberculosos/farmacologia , Estudos Transversais , Humanos , Isoniazida/farmacologia , Mycobacterium tuberculosis/efeitos dos fármacos , Rifampina/farmacologia , Sensibilidade e Especificidade
7.
J Clin Microbiol ; 54(8): 1984-91, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27194691

RESUMO

Currently available nucleic acid amplification platforms for tuberculosis (TB) detection are not designed to be simple or inexpensive enough to implement in decentralized settings in countries with a high burden of disease. The loop-mediated isothermal amplification platform (LAMP) may change this. We conducted a study in adults with symptoms suggestive of TB in India, Uganda, and Peru to establish the feasibility of using TB-LAMP (Eiken Chemical Co.) in microscopy laboratories compared with using smear microscopy against a reference standard of solid and liquid cultures. Operational characteristics were evaluated as well. A total of 1,777 participants met the eligibility criteria and were included for analysis. Overall, TB-LAMP sensitivities among culture-positive samples were 97.2% (243/250; 95% confidence interval [CI], 94.3% to 98.2%) and 62.0% (88/142; 95% CI, 53.5% to 70.0%) for smear-positive and smear-negative TB, respectively, but varied widely by country and operator. Specificities ranged from 94.5% (446/472; 95% CI, 92.0% to 96.4%) to 98.0% (350/357; 95% CI, 96.0% to 99.2%) by country. A root cause analysis identified high temperatures, high humidity, and/or low reaction volumes as possible causes for false-positive results, as they may result in nonspecific amplification. The study was repeated in India with training focused on vulnerable steps and an updated protocol; 580 participants were included for analysis. Specificity in the repeat trial was 96.6% (515/533; 95% CI, 94.7% to 97.9%). To achieve acceptable performance of LAMP at the microscopy center level, significant training and infrastructure requirements are necessary.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Tuberculose/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Índia , Masculino , Pessoa de Meia-Idade , Peru , Sensibilidade e Especificidade , Uganda , Adulto Jovem
8.
J Clin Microbiol ; 54(4): 1051-7, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26865685

RESUMO

The Epistem Genedrive assay rapidly detects the Mycobacterium tuberculosis omplex from sputum and is currently available for clinical use. However, the analytical and clinical performance of this test has not been fully evaluated. The analytical limit of detection (LOD) of the Genedrive PCR amplification was tested with genomic DNA; the performance of the complete (sample processing plus amplification) system was tested by spiking M. tuberculosismc(2)6030 cells into distilled water andM. tuberculosis-negative sputum. Specificity was tested using common respiratory pathogens and nontuberculosis mycobacteria. A clinical evaluation enrolled adults with suspected pulmonary tuberculosis, obtained three sputum samples from each participant, and compared the accuracy of the Gene drive to that of the Xpert MTB/RIF assay using M. tuberculosiscultures as the reference standard. The Genedrive assay had an LOD of 1 pg/µl (100 genomic DNA copies/reaction). The LODs of the system were 2.5 × 10(4)CFU/ml and 2.5 × 10(5)CFU/ml for cells spiked into water and sputum, respectively. False-positiverpoBprobe signals were observed in 3/32 (9.4%) of the negative controls and also in few samples containing Mycobacterium abscessus,Mycobacterium gordonae, o rMycobacterium thermoresistibile In the clinical study, among 336 analyzed participants, the overall sensitivities for the tuberculosis case detection of Gene drive, Xpert, and smear microscopy were 45.4% (95% confidence interval [CI], 35.2% to 55.8%), 91.8% (95% CI, 84.4% to 96.4%), and 77.3% (95% CI, 67.7% to 85.2%), respectively. The sensitivities of Gene drive and Xpert for the detection of smear-microscopy-negative tuberculosis were 0% (95% CI, 0% to 15.4%) and 68.2% (95% CI, 45.1% to 86.1%), respectively. The Genedrive assay did not meet performance standards recommended by the World Health Organization for a smear microscopy replacement tuberculosis test. Epistem is working on modifications to improve the assay.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/diagnóstico , Adulto , Estudos Transversais , Reações Falso-Positivas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/genética , Sensibilidade e Especificidade , Escarro/microbiologia
9.
J Infect Dis ; 211 Suppl 2: S29-38, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25765104

RESUMO

To accelerate the fight against tuberculosis, major diagnostic challenges need to be addressed urgently. Post-2015 targets are unlikely to be met without the use of novel diagnostics that are more accurate and can be used closer to where patients first seek care in affordable diagnostic algorithms. This article describes the efforts by the stakeholder community that led to the identification of the high-priority diagnostic needs in tuberculosis. Subsequently target product profiles for the high-priority diagnostic needs were developed and reviewed in a World Health Organization (WHO)-led consensus meeting. The high-priority diagnostic needs included (1) a sputum-based replacement test for smear-microscopy; (2) a non-sputum-based biomarker test for all forms of tuberculosis, ideally suitable for use at levels below microscopy centers; (3) a simple, low cost triage test for use by first-contact care providers as a rule-out test, ideally suitable for use by community health workers; and (4) a rapid drug susceptibility test for use at the microscopy center level. The developed target product profiles, along with complimentary work presented in this supplement, will help to facilitate the interaction between the tuberculosis community and the diagnostics industry with the goal to lead the way toward the post-2015 global tuberculosis targets.


Assuntos
Testes Diagnósticos de Rotina/métodos , Prioridades em Saúde , Técnicas de Diagnóstico Molecular/métodos , Tuberculose/diagnóstico , Biomarcadores/análise , Pesquisa Biomédica/economia , Pesquisa Biomédica/tendências , Testes Diagnósticos de Rotina/tendências , Humanos , Testes de Sensibilidade Microbiana/métodos , Técnicas de Diagnóstico Molecular/tendências , Escarro/microbiologia
10.
J Infect Dis ; 211 Suppl 2: S39-49, 2015 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-25765105

RESUMO

BACKGROUND: Current phenotypic testing for drug resistance in patients with tuberculosis is inadequate primarily with respect to turnaround time. Molecular tests hold the promise of an improved time to diagnosis. METHODS: A target product profile for a molecular drug-susceptibility test (DST) was developed on the basis of a collaborative effort that included opinions gathered from researchers, clinicians, policy makers, and test developers on optimal clinical and operational characteristics in settings of intended use. In addition, the current diagnostic ecosystem and the diagnostic development landscape were mapped. RESULTS: Molecular DSTs for detecting tuberculosis in microscopy centers should ideally evaluate for resistance to rifampin, fluoroquinolones, isoniazid, and pyrazinamide and enable the selection of the most appropriate treatment regimen. Performance characteristics of DSTs need to be optimized, but compromises can be made that depend on the trade-off between a false-positive result and a false-negative result. The operational requirements of a test will vary depending on the site of implementation. However, the most-important considerations pertain to quality control, maintenance and calibration, and the ability to export data. CONCLUSION: This target product profile defines the needs as perceived by the tuberculosis stakeholder community and attempts to provide a means of communication with test developers to ensure that fit-for-purpose DSTs are being developed.


Assuntos
Antituberculosos/farmacologia , Testes Diagnósticos de Rotina/métodos , Testes de Sensibilidade Microbiana/métodos , Técnicas de Diagnóstico Molecular/métodos , Tuberculose/diagnóstico , Antituberculosos/uso terapêutico , Testes Diagnósticos de Rotina/normas , Humanos , Testes de Sensibilidade Microbiana/normas , Técnicas de Diagnóstico Molecular/normas , Controle de Qualidade , Fatores de Tempo , Tuberculose/tratamento farmacológico
11.
Lancet ; 393(10178): 1331-1384, 2019 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-30904263
12.
PLoS Med ; 11(11): e1001760, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25423041

RESUMO

BACKGROUND: Xpert MTB/RIF is approved for use in tuberculosis (TB) and rifampicin-resistance diagnosis. However, data are limited on the impact of Xpert under routine conditions in settings with high TB burden. METHODS AND FINDINGS: A pragmatic prospective cluster-randomised trial of Xpert for all individuals with presumptive (symptomatic) TB compared to the routine diagnostic algorithm of sputum microscopy and limited use of culture was conducted in a large TB/HIV primary care clinic. The primary outcome was the proportion of bacteriologically confirmed TB cases not initiating TB treatment by 3 mo after presentation. Secondary outcomes included time to TB treatment and mortality. Unblinded randomisation occurred on a weekly basis. Xpert and smear microscopy were performed on site. Analysis was both by intention to treat (ITT) and per protocol. Between 7 September 2010 and 28 October 2011, 1,985 participants were assigned to the Xpert (n = 982) and routine (n = 1,003) diagnostic algorithms (ITT analysis); 882 received Xpert and 1,063 routine (per protocol analysis). 13% (32/257) of individuals with bacteriologically confirmed TB (smear, culture, or Xpert) did not initiate treatment by 3 mo after presentation in the Xpert arm, compared to 25% (41/167) in the routine arm (ITT analysis, risk ratio 0.51, 95% CI 0.33-0.77, p = 0.0052). The yield of bacteriologically confirmed TB cases among patients with presumptive TB was 17% (167/1,003) with routine diagnosis and 26% (257/982) with Xpert diagnosis (ITT analysis, risk ratio 1.57, 95% CI 1.32-1.87, p<0.001). This difference in diagnosis rates resulted in a higher rate of treatment initiation in the Xpert arm: 23% (229/1,003) and 28% (277/982) in the routine and Xpert arms, respectively (ITT analysis, risk ratio 1.24, 95% CI 1.06-1.44, p = 0.013). Time to treatment initiation was improved overall (ITT analysis, hazard ratio 0.76, 95% CI 0.63-0.92, p = 0.005) and among HIV-infected participants (ITT analysis, hazard ratio 0.67, 95% CI 0.53-0.85, p = 0.001). There was no difference in 6-mo mortality with Xpert versus routine diagnosis. Study limitations included incorrect intervention allocation for a high proportion of participants and that the study was conducted in a single clinic. CONCLUSIONS: These data suggest that in this routine primary care setting, use of Xpert to diagnose TB increased the number of individuals with bacteriologically confirmed TB who were treated by 3 mo and reduced time to treatment initiation, particularly among HIV-infected participants. TRIAL REGISTRATION: Pan African Clinical Trials Registry PACTR201010000255244. Please see later in the article for the Editors' Summary.


Assuntos
Farmacorresistência Bacteriana , Infecções por HIV/complicações , Mycobacterium tuberculosis/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Tempo para o Tratamento , Tuberculose/diagnóstico , Adolescente , Adulto , Idoso , Instituições de Assistência Ambulatorial , Antibióticos Antituberculose/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Atenção Primária à Saúde , Estudos Prospectivos , Rifampina/uso terapêutico , África do Sul , Tuberculose/complicações , Tuberculose/tratamento farmacológico , Tuberculose/microbiologia , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Tuberculose Resistente a Múltiplos Medicamentos/tratamento farmacológico , Tuberculose Resistente a Múltiplos Medicamentos/microbiologia , Adulto Jovem
13.
Eur Respir J ; 44(2): 435-46, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24696113

RESUMO

Xpert MTB/RIF (Cepheid, Sunnyvale, CA, USA) is endorsed for the detection of pulmonary tuberculosis (TB). We performed a systematic review and meta-analysis to assess the accuracy of Xpert for the detection of extrapulmonary TB. We searched multiple databases to October 15, 2013. We determined the accuracy of Xpert compared with culture and a composite reference standard (CRS). We grouped data by sample type and performed meta-analyses using a bivariate random-effects model. We assessed sources of heterogeneity using meta-regression for predefined covariates. We identified 18 studies involving 4461 samples. Sample processing varied greatly among the studies. Xpert sensitivity differed substantially between sample types. In lymph node tissues or aspirates, Xpert pooled sensitivity was 83.1% (95% CI 71.4-90.7%) versus culture and 81.2% (95% CI 72.4-87.7%) versus CRS. In cerebrospinal fluid, Xpert pooled sensitivity was 80.5% (95% CI 59.0-92.2%) against culture and 62.8% (95% CI 47.7-75.8%) against CRS. In pleural fluid, pooled sensitivity was 46.4% (95% CI 26.3-67.8%) against culture and 21.4% (95% CI 8.8-33.9%) against CRS. Xpert pooled specificity was consistently >98.7% against CRS across different sample types. Based on this systematic review, the World Health Organization now recommends Xpert over conventional tests for diagnosis of TB in lymph nodes and other tissues, and as the preferred initial test for diagnosis of TB meningitis.


Assuntos
Tuberculose/diagnóstico , Tuberculose/terapia , Antibióticos Antituberculose/uso terapêutico , Bases de Dados Factuais , Farmacorresistência Bacteriana , Infecções por HIV/complicações , Humanos , Técnicas de Diagnóstico Molecular , Mycobacterium tuberculosis/genética , Prevalência , Padrões de Referência , Análise de Regressão , Reprodutibilidade dos Testes , Rifampina/uso terapêutico , Sensibilidade e Especificidade , Organização Mundial da Saúde
14.
Cochrane Database Syst Rev ; (1): CD009593, 2014 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-24448973

RESUMO

BACKGROUND: Accurate, rapid detection of tuberculosis (TB) and TB drug resistance is critical for improving patient care and decreasing TB transmission. Xpert® MTB/RIF assay is an automated test that can detect both TB and rifampicin resistance, generally within two hours after starting the test, with minimal hands-on technical time. The World Health Organization (WHO) issued initial recommendations on Xpert® MTB/RIF in early 2011. A Cochrane Review on the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB and rifampicin resistance was published January 2013. We performed this updated Cochrane Review as part of a WHO process to develop updated guidelines on the use of the test. OBJECTIVES: To assess the diagnostic accuracy of Xpert® MTB/RIF for pulmonary TB (TB detection), where Xpert® MTB/RIF was used as both an initial test replacing microscopy and an add-on test following a negative smear microscopy result.To assess the diagnostic accuracy of Xpert® MTB/RIF for rifampicin resistance detection, where Xpert® MTB/RIF was used as the initial test replacing culture-based drug susceptibility testing (DST).The populations of interest were adults presumed to have pulmonary, rifampicin-resistant or multidrug-resistant TB (MDR-TB), with or without HIV infection. The settings of interest were intermediate- and peripheral-level laboratories. The latter may be associated with primary health care facilities. SEARCH METHODS: We searched for publications in any language up to 7 February 2013 in the following databases: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; ISI Web of Knowledge; MEDION; LILACS; BIOSIS; and SCOPUS. We also searched the metaRegister of Controlled Trials (mRCT) and the search portal of the WHO International Clinical Trials Registry Platform to identify ongoing trials. SELECTION CRITERIA: We included randomized controlled trials, cross-sectional studies, and cohort studies using respiratory specimens that allowed for extraction of data evaluating Xpert® MTB/RIF against the reference standard. We excluded gastric fluid specimens. The reference standard for TB was culture and for rifampicin resistance was phenotypic culture-based DST. DATA COLLECTION AND ANALYSIS: For each study, two review authors independently extracted data using a standardized form. When possible, we extracted data for subgroups by smear and HIV status. We assessed the quality of studies using QUADAS-2 and carried out meta-analyses to estimate pooled sensitivity and specificity of Xpert® MTB/RIF separately for TB detection and rifampicin resistance detection. For TB detection, we performed the majority of analyses using a bivariate random-effects model and compared the sensitivity of Xpert® MTB/RIF and smear microscopy against culture as reference standard. For rifampicin resistance detection, we undertook univariate meta-analyses for sensitivity and specificity separately to include studies in which no rifampicin resistance was detected. MAIN RESULTS: We included 27 unique studies (integrating nine new studies) involving 9557 participants. Sixteen studies (59%) were performed in low- or middle-income countries. For all QUADAS-2 domains, most studies were at low risk of bias and low concern regarding applicability.As an initial test replacing smear microscopy, Xpert® MTB/RIF pooled sensitivity was 89% [95% Credible Interval (CrI) 85% to 92%] and pooled specificity 99% (95% CrI 98% to 99%), (22 studies, 8998 participants: 2953 confirmed TB, 6045 non-TB).As an add-on test following a negative smear microscopy result, Xpert®MTB/RIF pooled sensitivity was 67% (95% CrI 60% to 74%) and pooled specificity 99% (95% CrI 98% to 99%; 21 studies, 6950 participants).For smear-positive, culture-positive TB, Xpert® MTB/RIF pooled sensitivity was 98% (95% CrI 97% to 99%; 21 studies, 1936 participants).For people with HIV infection, Xpert® MTB/RIF pooled sensitivity was 79% (95% CrI 70% to 86%; 7 studies, 1789 participants), and for people without HIV infection, it was 86% (95% CrI 76% to 92%; 7 studies, 1470 participants). Comparison with smear microscopy In comparison with smear microscopy, Xpert® MTB/RIF increased TB detection among culture-confirmed cases by 23% (95% CrI 15% to 32%; 21 studies, 8880 participants).For TB detection, if pooled sensitivity estimates for Xpert® MTB/RIF and smear microscopy are applied to a hypothetical cohort of 1000 patients where 10% of those with symptoms have TB, Xpert® MTB/RIF will diagnose 88 cases and miss 12 cases, whereas sputum microscopy will diagnose 65 cases and miss 35 cases. Rifampicin resistance For rifampicin resistance detection, Xpert® MTB/RIF pooled sensitivity was 95% (95% CrI 90% to 97%; 17 studies, 555 rifampicin resistance positives) and pooled specificity was 98% (95% CrI 97% to 99%; 24 studies, 2411 rifampicin resistance negatives). Among 180 specimens with nontuberculous mycobacteria (NTM), Xpert® MTB/RIF was positive in only one specimen that grew NTM (14 studies, 2626 participants).For rifampicin resistance detection, if the pooled accuracy estimates for Xpert® MTB/RIF are applied to a hypothetical cohort of 1000 individuals where 15% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 143 individuals as rifampicin resistant and miss eight cases, and correctly identify 833 individuals as rifampicin susceptible and misclassify 17 individuals as resistant. Where 5% of those with symptoms are rifampicin resistant, Xpert® MTB/RIF would correctly identify 48 individuals as rifampicin resistant and miss three cases and correctly identify 931 individuals as rifampicin susceptible and misclassify 19 individuals as resistant. AUTHORS' CONCLUSIONS: In adults thought to have TB, with or without HIV infection, Xpert® MTB/RIF is sensitive and specific. Compared with smear microscopy, Xpert® MTB/RIF substantially increases TB detection among culture-confirmed cases. Xpert® MTB/RIF has higher sensitivity for TB detection in smear-positive than smear-negative patients. Nonetheless, this test may be valuable as an add-on test following smear microscopy in patients previously found to be smear-negative. For rifampicin resistance detection, Xpert® MTB/RIF provides accurate results and can allow rapid initiation of MDR-TB treatment, pending results from conventional culture and DST. The tests are expensive, so current research evaluating the use of Xpert® MTB/RIF in TB programmes in high TB burden settings will help evaluate how this investment may help start treatment promptly and improve outcomes.


Assuntos
Antibióticos Antituberculose/uso terapêutico , Farmacorresistência Bacteriana , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Rifampina/uso terapêutico , Tuberculose Pulmonar/tratamento farmacológico , Adulto , Humanos , Mycobacterium tuberculosis/genética , Sensibilidade e Especificidade , Análise de Sequência de DNA/métodos , Tuberculose Pulmonar/diagnóstico
15.
N Engl J Med ; 363(11): 1005-15, 2010 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-20825313

RESUMO

BACKGROUND: Global control of tuberculosis is hampered by slow, insensitive diagnostic methods, particularly for the detection of drug-resistant forms and in patients with human immunodeficiency virus infection. Early detection is essential to reduce the death rate and interrupt transmission, but the complexity and infrastructure needs of sensitive methods limit their accessibility and effect. METHODS: We assessed the performance of Xpert MTB/RIF, an automated molecular test for Mycobacterium tuberculosis (MTB) and resistance to rifampin (RIF), with fully integrated sample processing in 1730 patients with suspected drug-sensitive or multidrug-resistant pulmonary tuberculosis. Eligible patients in Peru, Azerbaijan, South Africa, and India provided three sputum specimens each. Two specimens were processed with N-acetyl-L-cysteine and sodium hydroxide before microscopy, solid and liquid culture, and the MTB/RIF test, and one specimen was used for direct testing with microscopy and the MTB/RIF test. RESULTS: Among culture-positive patients, a single, direct MTB/RIF test identified 551 of 561 patients with smear-positive tuberculosis (98.2%) and 124 of 171 with smear-negative tuberculosis (72.5%). The test was specific in 604 of 609 patients without tuberculosis (99.2%). Among patients with smear-negative, culture-positive tuberculosis, the addition of a second MTB/RIF test increased sensitivity by 12.6 percentage points and a third by 5.1 percentage points, to a total of 90.2%. As compared with phenotypic drug-susceptibility testing, MTB/RIF testing correctly identified 200 of 205 patients (97.6%) with rifampin-resistant bacteria and 504 of 514 (98.1%) with rifampin-sensitive bacteria. Sequencing resolved all but two cases in favor of the MTB/RIF assay. CONCLUSIONS: The MTB/RIF test provided sensitive detection of tuberculosis and rifampin resistance directly from untreated sputum in less than 2 hours with minimal hands-on time. (Funded by the Foundation for Innovative New Diagnostics.)


Assuntos
Antituberculosos/farmacologia , Farmacorresistência Bacteriana , Mycobacterium tuberculosis/efeitos dos fármacos , Reação em Cadeia da Polimerase/métodos , Rifampina/farmacologia , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Tuberculose/microbiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Proteínas de Bactérias/genética , RNA Polimerases Dirigidas por DNA , Feminino , Humanos , Masculino , Testes de Sensibilidade Microbiana/métodos , Pessoa de Meia-Idade , Mycobacterium tuberculosis/genética , Reação em Cadeia da Polimerase/instrumentação , Estudos Prospectivos , Padrões de Referência , Sensibilidade e Especificidade , Escarro/microbiologia , Tuberculose/diagnóstico , Tuberculose Resistente a Múltiplos Medicamentos/microbiologia , Adulto Jovem
16.
J Clin Microbiol ; 51(7): 2311-6, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23678061

RESUMO

Tuberculosis (TB) remains a leading cause of death among HIV-infected adults, in part because of delayed diagnosis and therefore delayed initiation of treatment. Recently, the Gene-Xpert platform, a rapid, PCR-based diagnostic platform, has been validated for the diagnosis of TB with sputum. We have evaluated the Xpert MTB/RIF assay for the diagnosis of Mycobacterium tuberculosis bacteremia and investigated its impact on clinical outcomes. Consecutive HIV-infected adults with fever and cough presenting to Queen Elizabeth Central Hospital, Blantyre, Malawi, were recruited and followed up for 2 months. At presentation, three sputum samples were examined by smear, culture, and Xpert MTB/RIF assay for the presence of M. tuberculosis and blood was drawn for PCR with Xpert, for mycobacterial culture (Myco/F Lytic), and for aerobic culture. One hundred four patients were recruited, and 44 (43%) were sputum culture positive for M. tuberculosis. Ten were Xpert blood positive, for a sensitivity of 21% and a specificity of 100%. The 2-week mortality rate was significantly higher among patients who were Xpert blood positive than among those who were negative (40% versus 3%; multivariate odds ratio [OR] for death if positive, 44; 95% confidence interval [CI], 3 to 662). This effect persisted on assessment of the mortality rate at 2 months (40% versus 11%; OR, 5.6; 95% CI, 1.3 to 24.6). When screening uncomplicated patients presenting with a productive cough for pulmonary TB, Xpert blood offers no diagnostic advantage over sputum testing. Despite this, Xpert blood positivity is highly predictive of early death and this test rapidly identifies a group of patients in urgent need of initiation of treatment.


Assuntos
Bacteriemia/diagnóstico , Técnicas Bacteriológicas/métodos , Infecções por HIV/complicações , Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/diagnóstico , Adulto , Estudos de Coortes , Feminino , Humanos , Malaui , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/genética , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Sensibilidade e Especificidade , Análise de Sobrevida
17.
BMC Infect Dis ; 13: 407, 2013 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-24004840

RESUMO

Detection of the Mycobacterium tuberculosis cell wall antigen lipoarabinomannan (LAM) in urine permits diagnoses of tuberculosis (TB) to be made in HIV-infected patients with advanced immunodeficiency. This can be achieved at the point-of-care within just 30 minutes using the Determine TB-LAM, which is a commercially available, lateral-flow urine 'strip test' assay. The assay has been shown to have useful diagnostic accuracy in patients enrolling in antiretroviral treatment services or in HIV-infected patients requiring admission to hospital medical wards in sub-Saharan Africa. Such patients have high mortality risk and have most to gain from rapid diagnosis of TB and immediate initiation of treatment. However, few studies using this assay have yet been reported and many questions remain concerning the correct use of the assay, interpretation of results, the role of the assay as an add-on test within existing diagnostic algorithms and the types of further studies needed. In this paper we address a series of questions with the aim of informing the design, conduct and interpretation of future studies. Specifically, we clarify which clinical populations are most likely to derive benefit from use of this assay and how patients enrolled in such studies might best be characterised. We describe the importance of employing a rigorous microbiological diagnostic reference standard in studies of diagnostic accuracy and discuss issues surrounding the specificity of the assay in different geographical areas and potential cross-reactivity with non-tuberculous mycobacteria and other organisms. We highlight the importance of careful procedures for urine collection and storage and the critical issue of how to read and interpret the test strips. Finally, we consider how the assay could be used in combination with other assays and outline the types of studies that are required to build the evidence base concerning its use.


Assuntos
Infecções Oportunistas Relacionadas com a AIDS/diagnóstico , Antígenos de Bactérias/urina , Técnicas e Procedimentos Diagnósticos , Lipopolissacarídeos/urina , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/diagnóstico , Infecções Oportunistas Relacionadas com a AIDS/microbiologia , Infecções Oportunistas Relacionadas com a AIDS/urina , Antígenos de Bactérias/metabolismo , Parede Celular/metabolismo , Humanos , Lipopolissacarídeos/metabolismo , Mycobacterium tuberculosis/metabolismo , Tuberculose/microbiologia , Tuberculose/urina
18.
Semin Respir Crit Care Med ; 34(1): 17-31, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23460003

RESUMO

During the last decade there has been a dramatic change in the laboratory approach to tuberculosis (TB) diagnosis in the developing world. This change began with the realization that acid-fast bacillus smear microscopy alone was totally inadequate to deal with the dual problems of human immunodeficiency virus (HIV)-associated TB and drug-resistant TB that threaten to undermine global progress in TB control. Subsequently, increased financial resources for TB laboratory services and the establishment of a systematic process for endorsement of new TB diagnostic tools and approaches by the World Health Organization (WHO) have led to rapid expansion of TB laboratory services and the availability of several new diagnostic tests that have been introduced. These include both commercial automated and noncommercial systems for phenotypic mycobacterial liquid culture and drug susceptibility testing, a simple and inexpensive test for mycobacterial species identification in culture isolates, light-emitting diode fluorescence microscopy, and rapid molecular methods for TB case detection and the diagnosis of drug-resistant TB. The latter methodologies that include line probe assays and an automated cartridge-based real-time polymerase chain reaction (PCR)-based test are being scaled up at an unprecedented pace and are truly revolutionizing the diagnosis of drug-resistant TB. On the other hand, little progress has been made in the quest for a true point-of-care test for TB. Fortunately, this is being addressed in several discovery initiatives that hopefully will provide impetus for the development of rapid, accurate TB diagnostics for the lowest level of the health system.


Assuntos
Técnicas Bacteriológicas/métodos , Mycobacterium tuberculosis/isolamento & purificação , Tuberculose/diagnóstico , Países em Desenvolvimento , Saúde Global , Infecções por HIV/complicações , Humanos , Técnicas de Diagnóstico Molecular/métodos , Tuberculose/microbiologia , Tuberculose Resistente a Múltiplos Medicamentos/diagnóstico , Tuberculose Resistente a Múltiplos Medicamentos/microbiologia , Organização Mundial da Saúde
19.
Cochrane Database Syst Rev ; (1): CD009593, 2013 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-23440842

RESUMO

BACKGROUND: Accurate and rapid detection of tuberculosis (TB) and drug resistance are critical for improving patient care and decreasing the spread of TB. Xpert® MTB/RIF assay (Xpert) is a rapid, automated test that can detect both TB and rifampicin resistance, within two hours after starting the test, with minimal hands-on technical time, but is more expensive than conventional sputum microscopy. OBJECTIVES: To assess the diagnostic accuracy of Xpert for pulmonary TB (TB detection), both where Xpert was used as an initial test replacing microscopy, and where Xpert was used as an add-on test following a negative smear microscopy result.To assess the diagnostic accuracy of Xpert for rifampicin resistance detection where Xpert was used as the initial test, replacing conventional culture-based drug susceptibility testing.The population of interest was adults suspected of having pulmonary TB or multidrug-resistant TB (MDR-TB), with or without HIV infection. SEARCH METHODS: We performed a comprehensive search of the following databases: Cochrane Infectious Diseases Group Specialized Register; MEDLINE; EMBASE; ISI Web of Knowledge; MEDION; LILACS; BIOSIS; and SCOPUS. We also searched the metaRegister of Controlled Trials (mRCT) and the search portal of the WHO International Clinical Trials Registry Platform to identify ongoing trials. We performed searches on 25 September 2011 and we repeated them on 15 December 2011, without language restriction. SELECTION CRITERIA: We included randomized controlled trials, cross-sectional, and cohort studies that used respiratory specimens to compare Xpert with culture for detecting TB and Xpert with conventional phenotypic drug susceptibility testing for detecting rifampicin resistance. DATA COLLECTION AND ANALYSIS: For each study, two review authors independently extracted a set of data using a standardized data extraction form. When possible, we extracted data for subgroups by smear and HIV status. We assessed the quality of studies using the QUADAS-2 tool. We carried out meta-analyses to estimate the pooled sensitivity and specificity of Xpert separately for TB detection and rifampicin resistance detection using a bivariate random-effects model. We estimated the median pooled sensitivity and specificity and their 95% credible intervals (CrI). MAIN RESULTS: We identified 18 unique studies as eligible for this review, including two multicentre international studies, one with five and the other with six distinct study centres. The majority of studies (55.6%) were performed in low-income and middle-income countries. In 17 of the 18 studies, Xpert was performed by trained technicians in reference laboratories.When used as an initial test replacing smear microscopy (15 studies, 7517 participants), Xpert achieved a pooled sensitivity of 88% (95% CrI 83% to 92%) and pooled specificity of 98% (95% CrI 97% to 99%). As an add-on test following a negative smear microscopy result (14 studies, 5719 participants), Xpert yielded a pooled sensitivity of 67% (95% CrI 58% to 74%) and pooled specificity of 98% (95% CrI 97% to 99%). In clinical subgroups, we found the following accuracy estimates: the pooled sensitivity was 98% (95% CrI 97% to 99%) for smear-positive, culture-positive TB and 68% (95% CrI 59% to 75%) for smear-negative, culture-positive TB (15 studies); the pooled sensitivity was 80% (95% CrI 67% to 88%) in people living with HIV and 89% (95% CrI 81% to 94%) in people without HIV infection (four studies). For rifampicin resistance detection (11 studies, 2340 participants), Xpert achieved a pooled sensitivity of 94% (95% CrI 87% to 97%) and pooled specificity of 98% (95% CrI 97% to 99%). In a separate analysis, Xpert could distinguish between TB and nontuberculous mycobacteria (NTM) in clinical samples with high accuracy: among 139 specimens with NTM, Xpert was positive in only one specimen that grew NTM.In a hypothetical cohort of 1000 individuals suspected of having rifampicin resistance (a proxy for MDR-TB), where the prevalence of rifampicin resistance is 30%, we estimated that on average Xpert would wrongly identify 14 patients as being rifampicin resistant. In comparison, where the prevalence of rifampicin resistance is only 2%, we estimated that the number of individuals wrongly identified as rifampicin resistant would increase to 20, an increase of 43%. AUTHORS' CONCLUSIONS: This review shows that Xpert used as an initial diagnostic test for TB detection and rifampicin resistance detection in patients suspected of having TB, MDR-TB, or HIV-associated TB is sensitive and specific. Xpert may also be valuable as an add-on test following microscopy for patients who have previously been found to be smear-negative. An Xpert result that is positive for rifampicin resistance should be carefully interpreted and take into consideration the risk of MDR-TB in a given patient and the expected prevalence of MDR-TB in a given setting.Studies in this review mainly assessed sensitivity and specificity of the test when used in reference laboratories in research investigations. Most studies were performed in high TB burden countries. Ongoing use of Xpert in high TB burden countries will contribute to the evidence base on the diagnostic accuracy and clinical impact of Xpert in routine programmatic and peripheral health care settings, including settings where the test is performed at the point of care.


Assuntos
Antibióticos Antituberculose/uso terapêutico , Farmacorresistência Bacteriana , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/isolamento & purificação , Rifampina/uso terapêutico , Tuberculose Pulmonar/tratamento farmacológico , Adulto , Humanos , Mycobacterium tuberculosis/genética , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Análise de Sequência de DNA/métodos
20.
Clin Infect Dis ; 55(8): 1088-95, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22752518

RESUMO

BACKGROUND: A rapid diagnosis of pediatric pulmonary tuberculosis (PTB) using Xpert MTB/RIF (Mycobacterium tuberculosis/rifampicin) automated testing on induced sputum (IS) is possible, but the capacity for performing IS is limited. The diagnosis using a nasopharyngeal aspirate (NPA), which can be non-invasively obtained, is desirable. METHODS: Paired specimens (NPA and IS) were tested using smear, liquid culture and Xpert. The diagnostic accuracy of Xpert and smear was compared with culture for different specimens in children with suspected PTB. RESULTS: There were 535 children [median age 19 months, 117 (21·9%) HIV-infected] who had one IS and one NPA specimen; 396 had two paired specimens. A positive smear, Xpert test or culture occurred in 30 (5.6%), 81 (15.1%) and 87 children (16.3%), respectively. The culture yield was higher from IS (84/87, 96.6%) vs NPA (61/87, 70.1%, P < .001). Amongst children with two paired specimens, 63 culture-confirmed cases occurred [60 (95.2%) IS vs 48 (76.2%) NPA, P = .002]. The sensitivity of two Xpert tests was similar for IS and NPAs [(45/63) 71% vs (41/63) 65%, P = .444)]; the sensitivity of smear was lower for IS (21/63, 33%) and NPA (16/63, 25%). The incremental yield from a second IS was 9 cases (17.6%) by culture and 9 (25%) by Xpert testing; a second NPA increased the culture yield by 10 (26.3%) and Xpert by 11 (36.7%). Xpert specificity was 99.1% (98.1-100) for IS and 98.2% (96.8-99.6) for NPAs. Xpert testing provided faster results than culture (median 0 vs 15 days, P < .001). CONCLUSIONS: Xpert testing on 2 NPAs is useful in children with suspected PTB, particularly in settings where IS and culture are not feasible.


Assuntos
Técnicas Bacteriológicas/métodos , Técnicas de Diagnóstico Molecular/métodos , Nasofaringe/microbiologia , Tuberculose Pulmonar/diagnóstico , Tuberculose Pulmonar/microbiologia , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Mycobacterium tuberculosis/isolamento & purificação , Sensibilidade e Especificidade , Escarro/microbiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA