Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 49(7): 2436-2444, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35067735

RESUMO

AIM: Despite increasing use for the detection of biochemically recurrent prostate cancer (rPC), the diagnostic accuracy of positron emission tomography/computed tomography (PET/CT) with [18F]PSMA-1007 remains only partially investigated. The aim of this study was to determine the sensitivity (SE), specificity (SP), positive predictive value (PPV), and negative predictive value (NPV) for PC-local recurrence and metastases on a per region basis. MATERIALS AND METHODS: One hundred seventy-seven consecutive patients undergoing [18F]PSMA-1007 PET/CT for rPC were retrospectively analysed. Six body regions were defined: prostate fossa, pelvic lymph nodes (LN), retroperitoneal LN, supradiaphragmatic LN, bones, and soft tissue. A region was counted positive if at least one PSMA-positive lesion suspicious for PC was observed. Confirmation of a true-positive PSMA-avid lesion was defined as positive by histopathology, fall in serum prostate-specific antigen (PSA) (> 50%) after targeted therapy or confirmatory further CT, MRI, PET/CT, or bone scan imaging. Regions where additional imaging was able to confirm the absence of suspicious PC lesions or regions outside exclusively targeted RT with serum PSA decline (> 50%) were counted as true-negative regions. SE, SP, PPV, and NPV were calculated for all six regions. RESULTS: The overall PET-positivity rate was 91%. Conclusive follow-up for affirmation or refutation of a PSMA-positive lesion was available for 81/152 patients on a per region basis. In this subgroup, overall sensitivity, specificity, PPV, and NPV were 95% (CI: 0.90-0.98), 89% (CI: 0.83-0.93), 86% (0.80-0.90), and 96% (CI: 0.92-0.98), respectively. On a per region basis, PPV was 97% (CI: 0.83-0.99) for local recurrence, 93% (CI: 0.78-0.98) for pelvic LN, 87% (CI: 0.62-0.96) for retroperitoneal LN, 82% (CI: 0.52-0.95) for supradiaphragmatic LN, and 79% (0.65-0.89) for bone lesions. The number of solid organ metastases (n = 6) was too small for an accurate statistical analysis. CONCLUSION: The known high PET-positivity rate of [18F]PSMA-1007 PET/CT in rPC was confirmed, with corresponding high (> 90%) sensitivity and NPV on a per region basis. However, overall PPV was limited (86%), particularly for bone lesions (79%), which are a potential diagnostic weaknesses when using this tracer.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Radioisótopos de Gálio , Humanos , Masculino , Niacinamida/análogos & derivados , Oligopeptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Antígeno Prostático Específico , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
2.
Eur J Nucl Med Mol Imaging ; 49(6): 1843-1856, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34950968

RESUMO

PURPOSE: A critical bottleneck for the credibility of artificial intelligence (AI) is replicating the results in the diversity of clinical practice. We aimed to develop an AI that can be independently applied to recover high-quality imaging from low-dose scans on different scanners and tracers. METHODS: Brain [18F]FDG PET imaging of 237 patients scanned with one scanner was used for the development of AI technology. The developed algorithm was then tested on [18F]FDG PET images of 45 patients scanned with three different scanners, [18F]FET PET images of 18 patients scanned with two different scanners, as well as [18F]Florbetapir images of 10 patients. A conditional generative adversarial network (GAN) was customized for cross-scanner and cross-tracer optimization. Three nuclear medicine physicians independently assessed the utility of the results in a clinical setting. RESULTS: The improvement achieved by AI recovery significantly correlated with the baseline image quality indicated by structural similarity index measurement (SSIM) (r = -0.71, p < 0.05) and normalized dose acquisition (r = -0.60, p < 0.05). Our cross-scanner and cross-tracer AI methodology showed utility based on both physical and clinical image assessment (p < 0.05). CONCLUSION: The deep learning development for extensible application on unknown scanners and tracers may improve the trustworthiness and clinical acceptability of AI-based dose reduction.


Assuntos
Aprendizado Profundo , Fluordesoxiglucose F18 , Inteligência Artificial , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons/métodos
3.
Eur J Nucl Med Mol Imaging ; 48(13): 4456-4462, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34155538

RESUMO

PURPOSE: While acquisition of images in [68 Ga]Ga-PSMA-11 following longer uptake times can improve lesion uptake and contrast, resultant imaging quality and count statistics are limited by the isotope's half-life (68 min). Here, we present a series of cases demonstrating that when performed using a long axial field-of-view (LAFOV) PET/CT system, late imaging is feasible and can even provide improved image quality compared to regular acquisitions. METHODS: In this retrospective case series, we report our initial experiences with 10 patients who underwent standard imaging at 1 h p.i. following administration of 192 ± 36 MBq [68 Ga]Ga-PSMA-11 with additional late imaging performed at 4 h p.i. Images were acquired in a single bed position for 6 min at 1 h p.i. and 16 min p.i. at 4 h p.i. using a LAFOV scanner (106 cm axial FOV). Two experienced nuclear medicine physicians reviewed all scans in consensus and evaluated overall image quality (5-point Likert scale), lesion uptake in terms of standardised uptake values (SUV), tumour to background ratio (TBR) and target-lesion signal to background noise (SNR). RESULTS: Subjective image quality as rated on a 5-point Likert scale was only modestly lower for late acquisitions (4.2/5 at 4 h p.i.; 5/5 1 h p.i.), TBR was significantly improved (4 h: 3.41 vs 1 h: 1.93, p < 0.001) and SNR was improved with borderline significance (4 h: 33.02 vs 1 h: 24.80, p = 0.062) at later imaging. Images were obtained with total acquisition times comparable to routine examinations on standard axial FOV scanners. CONCLUSION: Late acquisition in tandem with a LAFOV PET/CT resulted in improvements in TBR and SNR and was associated with only modest impairment in subjective visual imaging quality. These data show that later acquisition times for [68 Ga]Ga-PSMA-11 may be preferable when performed on LAFOV systems.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Ácido Edético , Estudos de Viabilidade , Humanos , Masculino , Recidiva Local de Neoplasia , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos
4.
Eur J Nucl Med Mol Imaging ; 48(9): 2978-2989, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33550425

RESUMO

PURPOSE: Many radiotracers are currently available for the detection of recurrent prostate cancer (rPC), yet many have not been compared head-to-head in comparative imaging studies. There is therefore an unmet need for evidence synthesis to guide evidence-based decisions in the selection of radiotracers. The objective of this study was therefore to assess the detection rate of various radiotracers for the rPC. METHODS: The PUBMED, EMBASE, and the EU and NIH trials databases were searched without date or language restriction for comparative imaging tracers for 13 radiotracers of principal interest. Key search terms included 18F-PSMA-1007, 18F-DCPFyl, 68Ga-PSMA-11, 18F-PSMA-11, 68Ga-PSMA-I&T, 68Ga-THP-PSMA, 64Cu-PSMA-617, 18F-JK-PSMA-7, 18F-Fluciclovine, 18F-FABC, 18F-Choline, 11C-Choline, and 68Ga-RM2. Studies reporting comparative imaging data in humans in rPC were selected. Single armed studies and matched pair analyses were excluded. Twelve studies with eight radiotracers were eligible for inclusion. Two independent reviewers screened all studies (using the PRISMA-NMA statement) for inclusion criteria, extracted data, and assessed risk of bias (using the QUADAS-2 tool). A network meta-analysis was performed using Markov-Chain Monte Carlo Bayesian analysis to obtain estimated detection rate odds ratios for each tracer combination. RESULTS: A majority of studies were judged to be at risk of publication bias. With the exception of 18F-PSMA-1007, little difference in terms of detection rate was revealed between the three most commonly used PSMA-radiotracers (68Ga-PSMA-11, 18F-PSMA-1007, 18F-DCFPyl), which in turn showed clear superiority to choline and fluciclovine using the derived network. CONCLUSION: Differences in patient-level detection rates were observed between PSMA- and choline-radiotracers. However, there is currently insufficient evidence to favour one of the four routinely used PSMA-radioligands (PSMA-11, PSMA-1007, PSMA-I&T, and DCFPyl) over another owing to the limited evidence base and risk of publication bias revealed by our systematic review. A further limitation was lack of reporting on diagnostic accuracy, which might favour radiotracers with low specificity in an analysis restricted only to detection rate. The NMA derived can be used to inform the design of future clinical trials and highlight areas where current evidence is weak.


Assuntos
Radioisótopos de Cobre , Neoplasias da Próstata , Teorema de Bayes , Glutaratos , Humanos , Masculino , Recidiva Local de Neoplasia , Metanálise em Rede , Ácidos Fosfínicos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata/diagnóstico por imagem , Piridinas
5.
Eur J Nucl Med Mol Imaging ; 48(8): 2395-2404, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33797596

RESUMO

PURPOSE: To investigate the performance of the new long axial field-of-view (LAFOV) Biograph Vision Quadra PET/CT and a standard axial field-of-view (SAFOV) Biograph Vision 600 PET/CT (both: Siemens Healthineers) system using an intra-patient comparison. METHODS: Forty-four patients undergoing routine oncological PET/CT were prospectively included and underwent a same-day dual-scanning protocol following a single administration of either 18F-FDG (n = 20), 18F-PSMA-1007 (n = 16) or 68Ga-DOTA-TOC (n = 8). Half the patients first received a clinically routine examination on the SAFOV (FOVaxial 26.3 cm) in continuous bed motion and then immediately afterwards on the LAFOV system (10-min acquisition in list mode, FOVaxial 106 cm); the second half underwent scanning in the reverse order. Comparisons between the LAFOV at different emulated scan times (by rebinning list mode data) and the SAFOV were made for target lesion integral activity, signal to noise (SNR), target lesion to background ratio (TBR) and visual image quality. RESULTS: Equivalent target lesion integral activity to the SAFOV acquisitions (16-min duration for a 106 cm FOV) were obtained on the LAFOV in 1.63 ± 0.19 min (mean ± standard error). Equivalent SNR was obtained by 1.82 ± 1.00 min LAFOV acquisitions. No statistically significant differences (p > 0.05) in TBR were observed even for 0.5 min LAFOV examinations. Subjective image quality rated by two physicians confirmed the 10 min LAFOV to be of the highest quality, with equivalence between the LAFOV and the SAFOV at 1.8 ± 0.85 min. By analogy, if the LAFOV scans were maintained at 10 min, proportional reductions in applied radiopharmaceutical could obtain equivalent lesion integral activity for activities under 40 MBq and equivalent doses for the PET component of <1 mSv. CONCLUSION: Improved image quality, lesion quantification and SNR resulting from higher sensitivity were demonstrated for an LAFOV system in a head-to-head comparison under clinical conditions. The LAFOV system could deliver images of comparable quality and lesion quantification in under 2 min, compared to routine SAFOV acquisition (16 min for equivalent FOV coverage). Alternatively, the LAFOV system could allow for low-dose examination protocols. Shorter LAFOV acquisitions (0.5 min), while of lower visual quality and SNR, were of adequate quality with respect to target lesion identification, suggesting that ultra-fast or low-dose acquisitions can be acceptable in selected settings.


Assuntos
Fluordesoxiglucose F18 , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Oncologia , Movimento (Física) , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos
6.
Eur J Nucl Med Mol Imaging ; 48(8): 2500-2524, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33932183

RESUMO

Medical imaging methods are assuming a greater role in the workup of patients with COVID-19, mainly in relation to the primary manifestation of pulmonary disease and the tissue distribution of the angiotensin-converting-enzyme 2 (ACE 2) receptor. However, the field is so new that no consensus view has emerged guiding clinical decisions to employ imaging procedures such as radiography, computer tomography (CT), positron emission tomography (PET), and magnetic resonance imaging, and in what measure the risk of exposure of staff to possible infection could be justified by the knowledge gained. The insensitivity of current RT-PCR methods for positive diagnosis is part of the rationale for resorting to imaging procedures. While CT is more sensitive than genetic testing in hospitalized patients, positive findings of ground glass opacities depend on the disease stage. There is sparse reporting on PET/CT with [18F]-FDG in COVID-19, but available results are congruent with the earlier literature on viral pneumonias. There is a high incidence of cerebral findings in COVID-19, and likewise evidence of gastrointestinal involvement. Artificial intelligence, notably machine learning is emerging as an effective method for diagnostic image analysis, with performance in the discriminative diagnosis of diagnosis of COVID-19 pneumonia comparable to that of human practitioners.


Assuntos
COVID-19 , Pneumonia Viral , Inteligência Artificial , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , SARS-CoV-2
7.
Eur Radiol ; 31(10): 8030-8039, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33856522

RESUMO

OBJECTIVE: To investigate the impact of digital PET/CT on diagnostic certainty, patient-based sensitivity and interrater reliability. METHODS: Four physicians retrospectively evaluated two matched cohorts of patients undergoing [68Ga]Ga-PSMA-11 PET/CT on a digital (dPET/CT n = 65) or an analogue scanner (aPET/CT n = 65) for recurrent prostate cancer between 11/2018 and 03/2019. The number of equivocal and pathological lesions as well as the frequency of discrepant findings and the interrater reliability for the two scanners were compared. RESULTS: dPET/CT detected more lesions than aPET/CT (p < 0.001). A higher number of pathological scans were observed for dPET/CT (83% vs. 57%, p < 0.001). The true-positive rate at follow-up was 100% for dPET/CT compared to 84% for aPET/CT (p < 0.001). The proportion of lesions rated as non-pathological as a total of all PSMA-avid lesions detected for dPET/CT was comparable to aPET/CT (61.8% vs. 57.0%, p = 0.99). Neither a higher rate of diagnostically uncertain lesions (11.5% dPET/CT vs. 13.7% aPET/CT, p = 0.95) nor discrepant scans (where one or more readers differed in opinion as to whether the scan is pathological) were observed (18% dPET/CT vs. 17% aPET/CT, p = 0.76). Interrater reliability for pathological lesions was excellent for both scanner types (Cronbach's α = 0.923 dPET/CT; α = 0.948 aPET/CT) and interrater agreement was substantial for dPET/CT (Krippendorf's α = 0.701) and almost perfect in aPET/CT (α = 0.802). CONCLUSIONS: A higher detection rate for pathological lesions for dPET/CT compared with aPET/CT in multiple readers was observed. This improved sensitivity was coupled with an improved true-positive rate and was not associated with increased diagnostic uncertainty, rate of non-specific lesions, or reduced interrater reliability. KEY POINTS: • New generation digital scanners detect more cancer lesions in men with prostate cancer. • When using digital scanners, the doctors are able to diagnose prostate cancer lesions with better certainty • When using digital scanners, the doctors do not disagree with each other more than with other scanner types.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Próstata , Ácido Edético , Radioisótopos de Gálio , Humanos , Masculino , Recidiva Local de Neoplasia/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
8.
Radiology ; 288(1): 198-206, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29762090

RESUMO

Purpose To compare PET/MR hypoperfusion and hypometabolism in patients with Alzheimer disease (AD) and mild cognitive impairment (MCI) compared with healthy control (HC) participants. Materials and Methods Maps of cerebral blood flow (CBF; pulsed arterial spin-labeling [ASL] MRI), glucose metabolism (fluorine 18 [18F] fluorodeoxyglucose [FDG] PET), and gray matter (GM) volume (structural T1-weighted MRI) were calculated from integrated PET/MR data in 45 patients with AD (mean age, 69 years ± 9 [standard deviation]; age range, 51-89 years), 20 patients with MCI (mean age, 64 years ± 10; age range, 45-82 years), and 11 HC participants (mean age, 65 years ± 8; age range, 54-80 years) between 2011 and 2014. After preprocessing, voxel-wise analyses of variance, volume of interest, and independent component analyses were performed for comparisons of CBF and glucose metabolism. Results Analyses revealed high overlap between components, regional and quantitative hypoperfusion, and hypometabolism in patients with AD compared with HC participants in precuneus, parietal, temporal, and occipital cortex. In patients with MCI compared with HC participants, FDG PET exclusively demonstrated quantitative hypometabolism and a component in the precuneus. Volume-of-interest analysis in global GM in patients with AD compared with HC participants showed lower CBF (42 mL/100 g per minute ± 8 vs 49 mL/100 g per minute ± 7, respectively; P = .035) and lower FDG uptake (0.8 ± 0.1 vs 1 ± 0.1, respectively; P < .001). Conclusion In patients with AD, pulsed ASL MRI revealed regional and quantitative abnormalities and components similar to 18F-FDG PET with a reduced extent. In patients with MCI, 18F-FDG PET exclusively demonstrated quantitative hypometabolism and a component in the precuneus, indicating higher sensitivity to detect preclinical AD compared with the currently used pulsed ASL MRI sequence.


Assuntos
Doença de Alzheimer/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Fluordesoxiglucose F18 , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/fisiopatologia , Encéfalo/fisiopatologia , Circulação Cerebrovascular/fisiologia , Disfunção Cognitiva/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Compostos Radiofarmacêuticos , Marcadores de Spin
11.
Clin Nucl Med ; 46(12): e598-e599, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34735414

RESUMO

ABSTRACT: PSMA PET/CT is routinely used for the detection of prostate cancer (PC). However, increased PSMA-ligand uptake has been described in a variety of benign and malignant tissues. A 71-year-old man with biochemical recurrence of PC initially treated with radical prostatectomy was referred for PSMA-ligand PET/CT. Apart from 1 lymph node with intense PSMA-ligand uptake, suspicious for metastasis, disseminated PSMA-ligand-avid subcutaneous lesions were seen. Histopathology of 1 of these lesions revealed an epidermoid cyst. Physicians should remain cognizant of non-PC-related causes of increased PSMA-ligand uptake, of which this case represent yet another example.


Assuntos
Cisto Epidérmico , Neoplasias da Próstata , Idoso , Ácido Edético , Humanos , Ligantes , Masculino , Recidiva Local de Neoplasia/diagnóstico por imagem , Oligopeptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
12.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 4120-4122, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34892133

RESUMO

INTRODUCTION: The possibility of low-dose positron emission tomography (PET) imaging using high sensitivity long axial field of view (FOV) PET/computed tomography (CT) scanners makes CT a critical radiation burden in clinical applications. Artificial intelligence has shown the potential to generate PET images from non-corrected PET images. Our aim in this work is to develop a CT-free correction for a long axial FOV PET scanner. METHODS: Whole body PET images of 165 patients scanned with a digital regular FOV PET scanner (Biograph Vision 600 (Siemens Healthineers) in Shanghai and Bern) was included for the development and testing of the deep learning methods. Furthermore, the developed algorithm was tested on data of 7 patients scanned with a long axial FOV scanner (Biograph Vision Quadra, Siemens Healthineers). A 2D generative adversarial network (GAN) was developed featuring a residual dense block, which enables the model to fully exploit hierarchical features from all network layers. The normalized root mean squared error (NRMSE) and peak signal-to-noise ratio (PSNR), were calculated to evaluate the results generated by deep learning. RESULTS: The preliminary results showed that, the developed deep learning method achieved an average NRMSE of 0.4±0.3% and PSNR of 51.4±6.4 for the test on Biograph Vision, and an average NRMSE of 0.5±0.4% and PSNR of 47.9±9.4 for the validation on Biograph Vision Quadra, after applied transfer learning. CONCLUSION: The developed deep learning method shows the potential for CT-free AI-correction for a long axial FOV PET scanner. Work in progress includes clinical assessment of PET images by independent nuclear medicine physicians. Training and fine-tuning with more datasets will be performed to further consolidate the development.


Assuntos
Aprendizado Profundo , Inteligência Artificial , China , Humanos , Processamento de Imagem Assistida por Computador , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X
13.
Ann Nucl Med ; 35(4): 485-492, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33550515

RESUMO

PURPOSE: To establish the feasibility of shorter acquisition times (and by analogy, applied activity) on tumour detection and lesion contrast in digital PET/CT. METHODS: Twenty-one randomly selected patients who underwent oncological [18F]-FDG PET/CT on a digital PET/CT were retrospectively evaluated. Scan data were anonymously obtained and reconstructed in list-mode acquisition for a standard 2 min/bed position (bp), 1 min/bp and 30 s/bp (100%, 50% and 25% time or applied activity, respectively). Scans were randomized and read by two nuclear medicine physicians in a consensus read. Readers were blind to clinical details. Scans were evaluated for the number of pathological lesions detected. Measured uptake for lesions was evaluated by maximum and mean standardized uptake value (SUVmax and SUVmean, respectively) and tumour-to-backround ratio (TBR) were compared. Agreement between the three acquisitions was compared by Krippendorf's alpha. RESULTS: Overall n = 100 lesions were identified in the 2 min and 1 min/bp acquisitions and n = 98 lesions in the 30 s/bp acquisitions. Agreement between the three acquisitions with respect to lesion number and tumour-to-background ratio showed almost perfect agreement (K's α = 0.999). SUVmax, SUVmean and TBR likewise showed > 98% agreement, with longer acquisitions being associated with slightly higher mean TBR (2 min/bp 7.94 ± 4.41 versus 30 s/bp 7.84 ± 4.22, p < 0.05). CONCLUSION: Shorter acquisition times have traditionally been associated with reduced lesion detectability or the requirement for larger amounts of radiotracer activity. These data confirm that this is not the case for new-generation digital PET scanners, where the known higher sensitivity results in clinically adequate images for shorter acquisitions. Only a small variation in the semi-quantitative parameters SUVmax, SUVmean and TBR was seen, confirming that either reduction of acquisition time or (by analogy) applied activity can be reduced as much as 75% in digital PET/CT without apparent clinical detriment.


Assuntos
Fluordesoxiglucose F18/química , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Compostos Radiofarmacêuticos/química , Peso Corporal , Humanos , Processamento de Imagem Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
14.
J Nucl Med ; 62(9): 1252-1257, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-33547214

RESUMO

Renal excretion of some prostate-specific membrane antigen (PSMA) ligands and consequently increased bladder activity can obscure locally relapsing prostate cancer lesions in PSMA PET/CT. Furthermore, additional late imaging in PSMA PET/CT provides a useful method to clarify uncertain findings. The aim of this retrospective study was to investigate a modified imaging protocol combining late additional imaging with hydration and forced diuresis in individuals undergoing additional late scanning for uncertain lesions or low prostate-specific antigen. Methods: We compared an older protocol with a newer one. In the old protocol, patients undergoing 68Ga-PSMA-11 PET/CT were examined at 90 min after injection, with 1 L of oral hydration beginning at 30 min after injection and 20 mg of furosemide given intravenously at 1 h after injection, followed by additional late imaging at 2.5 h after injection without further preparation. In the new protocol, a second group received the same procedure as before, with an additional 0.5 L of oral hydration and 10 mg of furosemide intravenously 30 min before the late imaging. We examined 132 patients (76 with the old protocol and 56 with the new one) with respect to urinary bladder activity (SUVmean), prostate cancer lesion uptake (SUVmax), and lesion contrast (ratio of tumor SUVmax to bladder SUVmean for local relapses and ratio of tumor SUVmax to gluteal-muscle SUVmean for nonlocal prostate cancer lesions). Results: Bladder activity was significantly greater for the old protocol in the late scans than for the new protocol (ratio of bladder activity at 2.5 h to bladder activity at 1.5 h, 2.33 ± 1.17 vs. 1.37 ± 0.50, P < 0.0001). Increased tumor SUVmax and contrast were seen at 2.5 h compared with 1.5 h (P < 0.0001 for old protocol; P = 0.02 for new protocol). Increased bladder activity for the old protocol resulted in decreased lesion-to-bladder contrast, which was not the case for the new protocol. Tumor-to-background ratios increased at late imaging for both protocols, but the increase was significantly lower for the new protocol. For the old protocol, comparing the 1.5-h to the 2.5-h acquisitions, 4 lesions in 4 patients (4/76 = 5.2% of the cohort) were visible at the postdiuresis 1.5-h acquisition but not at 2.5 h, having been obscured as a result of the higher bladder activity. In the new protocol, 2 of 56 (3.6%) patients had lesions visible only at late imaging, and 2 patients had lesions that could be better discriminated at late imaging. Conclusion: Although the combination of diuretics and hydration can be a useful method to increase the visualization and detectability of locally recurrent prostate cancer in standard 68Ga-PSMA-11 PET/CT, their effects do not sufficiently continue into additional late imaging. Additional diuresis and hydration are recommended to improve the visibility, detection, and diagnostic certainty of local recurrences.


Assuntos
Isótopos de Gálio , Radioisótopos de Gálio , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Idoso , Humanos , Pessoa de Meia-Idade , Antígeno Prostático Específico , Estudos Retrospectivos
15.
Brain Sci ; 9(9)2019 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-31480355

RESUMO

Recent approaches have suggested that deep brain stimulation (DBS) for obsessive-compulsive disorder relies on distributed networks rather than local brain modulation. However, there is insufficient data on how DBS affects brain metabolism both locally and globally. We enrolled three patients with treatment-refractory obsessive-compulsive disorder with ongoing DBS of the bilateral ventral capsule/ventral striatum. Patients underwent resting-state 18F-fluorodeoxyglucose and positron emission tomography in both stimulation ON and OFF conditions. All subjects showed relative hypometabolism in prefronto-basal ganglia-thalamic networks compared to a healthy control cohort when stimulation was switched OFF. Switching the stimulation ON resulted in differential changes in brain metabolism. Locally, volumes of activated tissue at stimulation sites (n = 6) showed a significant increase in metabolism during DBS ON compared to DBS OFF (Mean difference 4.5 % ± SD 2.8; p = 0.012). Globally, differential changes were observed across patients encompassing prefrontal increase in metabolism in ON vs. OFF condition. Bearing in mind limitations of the small sample size, we conclude that DBS of the ventral capsule/ventral striatum for obsessive-compulsive disorder increases brain metabolism locally. Across distributed global networks, DBS appears to exert differential effects, possibly depending on localization of stimulation sites and response to the intervention.

16.
J Cereb Blood Flow Metab ; 39(7): 1314-1325, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-29431005

RESUMO

Functional connectivity of blood oxygenation level dependent signal fluctuations (BOLD-FC) is decreased in Alzheimer's disease (AD), and suggested to reflect reduced coherence in neural population activity; however, as both neuronal and vascular-hemodynamic processes underlie BOLD signals, impaired perfusion might also contribute to reduced BOLD-FC; 42 AD patients and 27 controls underwent simultaneous PET/MR imaging. Resting-state functional MRI assessed BOLD co-activity to quantify BOLD-FC, pulsed arterial spin labeling (pASL) assessed cerebral blood flow (CBF) as proxy for vascular hemodynamics, and 18F-fluorodeoxyglucose PET assessed glucose metabolism (GluMet) to index neuronal activity. Patients' BOLD-FC, CBF, and GluMet were reduced within the same precuneal parietal regions. BOLD-FC was positively associated with mean CBF, specifically in patients and controlled for GluMet levels, suggesting that BOLD-FC reductions correlate with pASL-derived hypoperfusion in AD, independently from 18F-fluorodeoxyglucose PET-derived hypometabolism. Data indicate that impaired vascular hemodynamic processes contribute to reduced BOLD connectivity in AD.


Assuntos
Doença de Alzheimer/fisiopatologia , Circulação Cerebrovascular/fisiologia , Oxigênio/sangue , Transdução de Sinais/fisiologia , Idoso , Idoso de 80 Anos ou mais , Encéfalo/irrigação sanguínea , Encéfalo/fisiopatologia , Feminino , Fluordesoxiglucose F18 , Hemodinâmica/fisiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neurônios/fisiologia , Tomografia por Emissão de Pósitrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA