Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 50(2): 287-301, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36271158

RESUMO

BACKGROUND: ZED8 is a novel monovalent antibody labeled with zirconium-89 for the molecular imaging of CD8. This work describes nonclinical studies performed in part to provide rationale for and to inform expectations in the early clinical development of ZED8, such as in the studies outlined in clinical trial registry NCT04029181 [1]. METHODS: Surface plasmon resonance, X-ray crystallography, and flow cytometry were used to characterize the ZED8-CD8 binding interaction, its specificity, and its impact on T cell function. Immuno-PET with ZED8 was assessed in huCD8+ tumor-bearing mice and in non-human primates. Plasma antibody levels were measured by ELISA to determine pharmacokinetic parameters, and OLINDA 1.0 was used to estimate radiation dosimetry from image-derived biodistribution data. RESULTS: ZED8 selectively binds to human CD8α at a binding site approximately 9 Å from that of MHCI making mutual interference unlikely. The equilibrium dissociation constant (KD) is 5 nM. ZED8 binds to cynomolgus CD8 with reduced affinity (66 nM) but it has no measurable affinity for rat or mouse CD8. In a series of lymphoma xenografts, ZED8 imaging was able to identify different CD8 levels concordant with flow cytometry. In cynomolgus monkeys with tool compound 89Zr-aCD8v17, lymph nodes were conspicuous by imaging 24 h post-injection, and the pharmacokinetics suggested a flat-fixed first-in-human dose of 4 mg per subject. The whole-body effective dose for an adult human was estimated to be 0.48 mSv/MBq, comparable to existing 89Zr immuno-PET reagents. CONCLUSION: 89Zr immuno-PET with ZED8 appears to be a promising biomarker of tissue CD8 levels suitable for clinical evaluation in cancer patients eligible for immunotherapy.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons , Adulto , Humanos , Camundongos , Ratos , Animais , Tomografia por Emissão de Pósitrons/métodos , Indicadores e Reagentes/uso terapêutico , Distribuição Tecidual , Neoplasias/terapia , Neoplasias/tratamento farmacológico , Imunoterapia/métodos , Zircônio/química , Linfócitos T CD8-Positivos/metabolismo , Linhagem Celular Tumoral
3.
Alzheimers Dement (Amst) ; 15(3): e12454, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37424964

RESUMO

INTRODUCTION: Recently, an increasing number of tau tracers have become available. There is a need to standardize quantitative tau measures across tracers, supporting a universal scale. We developed several cortical tau masks and applied them to generate a tau imaging universal scale. METHOD: One thousand forty-five participants underwent tau scans with either 18F-flortaucipir, 18F-MK6240, 18F-PI2620, 18F-PM-PBB3, 18F-GTP1, or 18F-RO948. The universal mask was generated from cognitively unimpaired amyloid beta (Aß)- subjects and Alzheimer's disease (AD) patients with Aß+. Four additional regional cortical masks were defined within the constraints of the universal mask. A universal scale, the CenTauRz, was constructed. RESULTS: None of the regions known to display off-target signal were included in the masks. The CenTauRz allows robust discrimination between low and high levels of tau deposits. DISCUSSION: We constructed several tau-specific cortical masks for the AD continuum and a universal standard scale designed to capture the location and degree of abnormality that can be applied across tracers and across centers. The masks are freely available at https://www.gaain.org/centaur-project.

4.
J Nucl Med Technol ; 48(1): 54-57, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31604892

RESUMO

Our objective was to harmonize multicenter 89Zr PET imaging for oncology trials and to evaluate lesion detection. Methods: Seven PET scanners were evaluated using a custom chest oncology phantom with 9 spheric lesions 7-20 mm in diameter. A 4:1 signal-to-background ratio simulated a patient dose of 92.5 MBq. Various image reconstructions were evaluated. Images were assessed for lesion detection, and recovery coefficients and background signal variance were measured. Results: Two scanners failed to provide acceptable images and data. Optimal reconstruction algorithms enabling adequate lesion detection and reliable quantification across the other 5 scanners were determined without compromising the data quality. On average, 95% of the 10-mm lesions were detected, and the 7-mm lesion was visualized by only 1 scanner. Background variance was 8.6%-16%. Conclusion: We established multicenter harmonization procedures for 89Zr PET imaging in oncology, optimizing small-lesion (≥10 mm) detectability and accurate quantification.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Estudos Multicêntricos como Assunto , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Zircônio , Humanos , Imagens de Fantasmas , Radioisótopos
5.
Nat Med ; 24(12): 1852-1858, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30478423

RESUMO

Programmed cell death protein-1/ligand-1 (PD-1/PD-L1) blockade is effective in a subset of patients with several tumor types, but predicting patient benefit using approved diagnostics is inexact, as some patients with PD-L1-negative tumors also show clinical benefit1,2. Moreover, all biopsy-based tests are subject to the errors and limitations of invasive tissue collection3-11. Preclinical studies of positron-emission tomography (PET) imaging with antibodies to PD-L1 suggested that this imaging method might be an approach to selecting patients12,13. Such a technique, however, requires substantial clinical development and validation. Here we present the initial results from a first-in-human study to assess the feasibility of imaging with zirconium-89-labeled atezolizumab (anti-PD-L1), including biodistribution, and secondly test its potential to predict response to PD-L1 blockade (ClinicalTrials.gov identifiers NCT02453984 and NCT02478099). We imaged 22 patients across three tumor types before the start of atezolizumab therapy. The PET signal, a function of tracer exposure and target expression, was high in lymphoid tissues and at sites of inflammation. In tumors, uptake was generally high but heterogeneous, varying within and among lesions, patients, and tumor types. Intriguingly, clinical responses in our patients were better correlated with pretreatment PET signal than with immunohistochemistry- or RNA-sequencing-based predictive biomarkers, encouraging further development of molecular PET imaging for assessment of PD-L1 status and clinical response prediction.


Assuntos
Anticorpos Monoclonais/administração & dosagem , Antígeno B7-H1/administração & dosagem , Tomografia por Emissão de Pósitrons , Radioisótopos/administração & dosagem , Zircônio/administração & dosagem , Adulto , Idoso , Anticorpos Monoclonais/química , Anticorpos Monoclonais Humanizados , Antígeno B7-H1/química , Biópsia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Linhagem Celular Tumoral , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Radioisótopos/química , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/química , Distribuição Tecidual/efeitos dos fármacos , Neoplasias de Mama Triplo Negativas/diagnóstico por imagem , Neoplasias de Mama Triplo Negativas/patologia , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Zircônio/química
6.
Clin Cancer Res ; 21(11): 2462-70, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26034219

RESUMO

PURPOSE: The novel dual-action humanized IgG1 antibody MEHD7945A targeting HER3 and EGFR inhibits ligand-dependent HER dimer signaling. This phase I study evaluated the safety, pharmacokinetics, pharmacodynamics, and antitumor activity of MEHD7945A. EXPERIMENTAL DESIGN: Patients with locally advanced or metastatic epithelial tumors received escalating doses of MEHD7945A (1-30 mg/kg) every 2 weeks (q2w) until disease progression or intolerable toxicity. An expansion cohort was enrolled at the recommended phase II dose (14 mg/kg, q2w). Plasma samples, tumor biopsies, FDG-PET were obtained for assessment of pharmacokinetics, and pharmacodynamic modulation downstream of EGFR and HER3. RESULTS: No dose-limiting toxicities or MEHD7945A-related grade ≥ 4 adverse events (AE) were reported in dose-escalation (n = 30) or expansion (n = 36) cohorts. Related grade 3 AEs were limited to diarrhea and nausea in the same patient (30 mg/kg). Related AEs in ≥20% of patients ≤24 hours after the first infusion included grade 1/2 headache, fever, and chills, which were managed with premedication and/or symptomatic treatment. Pharmacodynamic data indicated target inhibition in 25% of evaluable patients. Best response by RECIST included 2 confirmed partial responses in squamous cell carcinomas of head and neck (SCCHN) patients with high tumor tissue levels of the HER3 ligand heregulin; 14 patients had stable disease ≥8 weeks, including SCCHN (n = 3), colorectal cancer (n = 6), and non-small cell lung cancer (n = 3). CONCLUSIONS: MEHD7945A was well-tolerated as single agent with evidence of tumor pharmacodynamic modulation and antitumor activity in SCCHN. Phase II studies were initiated with flat (nonweight-based) dosing at 1,100 mg q2w in SCCHN and colorectal cancer.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma de Células Escamosas/tratamento farmacológico , Receptores ErbB/imunologia , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Imunoglobulina G/administração & dosagem , Receptor ErbB-3/imunologia , Adulto , Idoso , Anticorpos Monoclonais/administração & dosagem , Anticorpos Monoclonais Humanizados/administração & dosagem , Anticorpos Monoclonais Humanizados/efeitos adversos , Anticorpos Monoclonais Humanizados/farmacocinética , Protocolos de Quimioterapia Combinada Antineoplásica , Carcinoma Pulmonar de Células não Pequenas/imunologia , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma de Células Escamosas/imunologia , Carcinoma de Células Escamosas/patologia , Cetuximab/administração & dosagem , Relação Dose-Resposta a Droga , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/classificação , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/patologia , Receptores ErbB/antagonistas & inibidores , Cloridrato de Erlotinib/administração & dosagem , Feminino , Neoplasias de Cabeça e Pescoço/imunologia , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Imunoglobulina G/efeitos adversos , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , Panitumumabe , Receptor ErbB-3/antagonistas & inibidores , Carcinoma de Células Escamosas de Cabeça e Pescoço
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA