RESUMO
Many environmental and industrial processes depend on how fluids displace each other in porous materials. However, the flow dynamics that govern this process are still poorly understood, hampered by the lack of methods to measure flows in optically opaque, microscopic geometries. We introduce a 4D microvelocimetry method based on high-resolution X-ray computed tomography with fast imaging rates (up to 4 Hz). We use this to measure flow fields during unsteady-state drainage, injecting a viscous fluid into rock and filter samples. This provides experimental insight into the nonequilibrium energy dynamics of this process. We show that fluid displacements convert surface energy into kinetic energy. The latter corresponds to velocity perturbations in the pore-scale flow field behind the invading fluid front, reaching local velocities more than 40 times faster than the constant pump rate. The characteristic length scale of these perturbations exceeds the characteristic pore size by more than an order of magnitude. These flow field observations suggest that nonlocal dynamic effects may be long-ranged even at low capillary numbers, impacting the local viscous-capillary force balance and the representative elementary volume. Furthermore, the velocity perturbations can enhance unsaturated dispersive mixing and colloid transport and yet, are not accounted for in current models. Overall, this work shows that 4D X-ray velocimetry opens the way to solve long-standing fundamental questions regarding flow and transport in porous materials, underlying models of, e.g., groundwater pollution remediation and subsurface storage of CO2 and hydrogen.
RESUMO
X-ray dual-phase grating interferometry provides quantitative micro-structural information beyond the optical resolution through its tunable correlation length. Ensuring optimal performance of the set-up requires accurate correlation length estimation and precise alignment of the gratings. This paper presents an automated procedure for determining the complete geometrical parameters of the interferometer set-up with a high degree of precision. The algorithm's effectiveness is then evaluated through a series of experimental tests, illustrating its accuracy and robustness.
RESUMO
Background Interstitial lung abnormalities (ILAs) reflect imaging features on lung CT scans that are compatible with (early) interstitial lung disease. Despite accumulating evidence regarding the incidence, risk factors, and prognosis of ILAs, the histopathologic correlates of ILAs remain elusive. Purpose To determine the correlation between radiologic and histopathologic findings in CT-defined ILAs in human lung explants. Materials and Methods Explanted lungs or lobes from participants with radiologically documented ILAs were prospectively collected from 2010 to 2021. These specimens were air-inflated, frozen, and scanned with CT and micro-CT (spatial resolution of 0.7 mm and 90 µm, respectively). Subsequently, the lungs were cut and sampled with core biopsies. At least five samples per lung underwent micro-CT and subsequent histopathologic assessment with semiquantitative remodeling scorings. Based on area-specific radiologic scoring, the association between radiologic and histopathologic findings was assessed. Results Eight lung explants from six donors (median age at explantation, 71 years [range, 60-83 years]; four men) were included (unused donor lungs, n = 4; pre-emptive lobectomy for oncologic indications, n = 2). Ex vivo CT demonstrated ground-glass opacification, reticulation, and bronchiectasis. Micro-CT and histopathologic examination demonstrated that lung abnormalities were frequently paraseptal and associated with fibrosis and lymphocytic inflammation. The histopathologic results showed varying degrees of fibrosis in areas that appeared normal on CT scans. Regions of reticulation on CT scans generally had greater fibrosis at histopathologic analysis. Vasculopathy and bronchiectasis were also often present at histopathologic examination of lungs with ILAs. Fully developed fibroblastic foci were rarely observed. Conclusion This study demonstrated direct histologic correlates of CT-defined interstitial lung abnormalities. © RSNA, 2022 Supplemental material is available for this article. See also the editorial by Jeudy in this issue.
Assuntos
Bronquiectasia , Doenças Pulmonares Intersticiais , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Pulmão/diagnóstico por imagem , Pulmão/patologia , Doenças Pulmonares Intersticiais/diagnóstico por imagem , Fibrose , Microtomografia por Raio-XRESUMO
The dark-field signal provided by X-ray grating interferometry is an invaluable tool for providing structural information beyond the direct spatial resolution and their variations on a macroscopic scale. However, when using a polychromatic source, the beam-hardening effect in the dark-field signal makes the quantitative sub-resolution structural information inaccessible. Especially, the beam-hardening effect in dual-phase grating interferometry varies with spatial location, inter-grating distance, and diffraction order. In this work, we propose a beam-hardening correction algorithm, taking into account all these factors. The accuracy and robustness of the algorithm are then validated by experimental results. This work contributes a necessary step toward accessing small-angle scattering structural information in dual-phase grating interferometry.
RESUMO
In this work, we analyze the interference patterns measured in lab-based dual-phase grating interferometry and for the first time explain the spatial dependencies of the measured interference patterns and the large visibility deviations between the theoretical prediction and the experimental results. To achieve this, a simulator based on wave propagation is developed. This work proves that the experimental results can be simulated with high accuracy by including the effective grating thickness profile induced by the cone-beam geometry, the measured detector response function and a non-ideal grating shape. With the comprehensive understanding of dual-phase grating interferometry, this provides the foundations for a more efficient and accurate algorithm to retrieve sample's structure information, and the realistic simulator is a useful tool for optimizing the set-up.
RESUMO
Fifth generation networks (5G) will be associated with a partial shift to higher carrier frequencies, including wavelengths comparable in size to insects. This may lead to higher absorption of radio frequency (RF) electromagnetic fields (EMF) by insects and could cause dielectric heating. The yellow fever mosquito (Aedes aegypti), a vector for diseases such as yellow and dengue fever, favors warm climates. Being exposed to higher frequency RF EMFs causing possible dielectric heating, could have an influence on behavior, physiology and morphology, and could be a possible factor for introduction of the species in regions where the yellow fever mosquito normally does not appear. In this study, the influence of far field RF exposure on A. aegypti was examined between 2 and 240 GHz. Using Finite Difference Time Domain (FDTD) simulations, the distribution of the electric field in and around the insect and the absorbed RF power were found for six different mosquito models (three male, three female). The 3D models were created from micro-CT scans of real mosquitoes. The dielectric properties used in the simulation were measured from a mixture of homogenized A. aegypti. For a given incident RF power, the absorption increases with increasing frequency between 2 and 90 GHz with a maximum between 90 and 240 GHz. The absorption was maximal in the region where the wavelength matches the size of the mosquito. For a same incident field strength, the power absorption by the mosquito is 16 times higher at 60 GHz than at 6 GHz. The higher absorption of RF power by future technologies can result in dielectric heating and potentially influence the biology of this mosquito.
Assuntos
Aedes , Mosquitos Vetores , Ondas de Rádio , Aedes/fisiologia , Aedes/efeitos da radiação , Animais , Feminino , Temperatura Alta , Masculino , Mosquitos Vetores/fisiologia , Mosquitos Vetores/efeitos da radiação , Febre Amarela/transmissãoRESUMO
BACKGROUND AND AIMS: Foliar water uptake has recently been suggested as a possible mechanism for the restoration of hydraulically dysfunctional xylem vessels. In this paper we used a combination of ecophysiological measurements, X-ray microcomputed tomography and cryo-scanning electron microscopy during a drought treatment to fully evaluate this hypothesis. KEY RESULTS: Based on an assessment of these methods in beech (Fagus sylvatica L.) seedlings we were able to (1) confirm an increase in the amount of hydraulically redistributed water absorbed by leaves when the soil water potential decreased, and (2) locate this redistributed water in hydraulically active vessels in the stem. However, (3) no embolism repair was observed irrespective of the organ under investigation (i.e. stem, petiole or leaf) or the intensity of drought. CONCLUSIONS: Our data provide evidence for a hydraulic pathway from the leaf surface to the stem xylem following a water potential gradient, but this pathway exists only in functional vessels and does not play a role in embolism repair for beech.
Assuntos
Embolia , Fagus , Secas , Embolia/metabolismo , Folhas de Planta/fisiologia , Água/metabolismo , Microtomografia por Raio-X , Xilema/fisiologiaRESUMO
BACKGROUND: Scientific knowledge regarding alpaca dentistry is relatively limited despite its clinical implications. The present gap in available supportive data leads to limited treatment options for dental pathology in alpacas in comparison to other species. The main goal of this study was to gain novel insights into the general and pulp morphology of maxillary cheek teeth to allow development of more advanced treatment strategies in the future. Also, the risk of causing pulp exposure when floating maxillary cheek teeth was of particular interest. Concurent research focusing on the anatomy of mandibular cheek teeth has been performed accordingly. The results obtained in mandibular teeth are expected to be non-extrapolatable because of the structural differences between mandibular and maxillary teeth. RESULTS: Pulp morphology of maxillary cheek teeth showed great variation. A common pulp chamber was identified in 46/83 (55.4%) teeth with a mean dental age of 2 years and 7 months (± 2 years and 5 months). Pulpal segmentation was more commonly observed in teeth of increasing age. Full columnar segmentation was seen in 33/69 teeth (47.8%), whereas within-column segmentation was observed in 36/83 teeth (43.4%). Age and degree of segmentation of the pulpal tissue varied greatly according to Triadan position. Physical contact between roots of adjacent teeth was found in the majority of examined molars (range 82-94%) which resulted in morphological adaptations at the level of the root tips. The measured sub-occlusal dentinal thickness was as low as 0.46 mm above pulp horn 2 in a 14 years and 11 months old Triadan 09, emphasizing the risk of pulp exposure attributed to dental floating. CONCLUSION: This study offers an objective description of age-dependent maxillary cheek teeth pulp morphology in alpacas. Current findings are of great value to provide a basis for the development of tooth-saving techniques as a treatment for dental disease in this species. Observed physical contact between the roots of different examined molars may be a facilitating factor in the spread of apical infection in chronically diseased cases. Finally, a conservative approach regarding dental floating is recommended in order to avoid iatrogenic damage to pulp tissue.
Assuntos
Camelídeos Americanos , Dente , Animais , Bochecha , Maxila , Dente/anatomia & histologia , Microtomografia por Raio-XRESUMO
Through measuring the intensity of the fluorescence X-rays emitted by the elements of interest, X-ray fluorescence computed tomography (XFCT) is capable of mapping the elemental distribution inside an object without destructively sectioning it. With the recent advances in XFCT utilizing polychromatic microfocus X-ray sources, it is expected that the popularity of such imaging modality will rise further. However, XFCT suffers from self-absorption effects, which make it challenging to reconstruct the elemental distribution inside the sample accurately. For this reason, polychromatic XFCT is mainly used to retrieve the distribution of elements with a relatively high atomic number (Z) when compared to the matrix of the sample. To enable the quantitative reconstruction of trace and low Z elements with polychromatic XFCT, a novel reconstruction method has been proposed in this manuscript. Through examining the proposed method on both simulation data and experimental data, its capacity on retrieving the density distribution of relatively low Z elements has been confirmed.
RESUMO
X-ray ptychography has revolutionized nanoscale phase contrast imaging at large-scale synchrotron sources in recent years. We present here the first successful demonstration of the technique in a small-scale laboratory setting. An experiment was conducted with a liquid metal-jet x-ray source and a single photon-counting detector with a high spectral resolution. The experiment used a spot size of 5 µm to produce a ptychographic phase image of a Siemens star test pattern with a submicron spatial resolution. The result and methodology presented show how high-resolution phase contrast imaging can now be performed at small-scale laboratory sources worldwide.
RESUMO
BACKGROUND: Despite dental disease being a common health concern in alpacas, important dental pathology including apical infection, remains poorly understood. Treatment options are limited compared to veterinary dentistry techniques in other species. The primary goal of this study was to increase understanding of the external and internal anatomy of mandibular cheek teeth to enable the development of tooth sparing techniques in this species. Also, an objective evaluation of the sub-occlusal dentinal thickness in normal mandibular cheek teeth is warranted to understand the risks associated with reduction of overgrown teeth. RESULTS: Overall pulp anatomy was variably characterized by the presence of a common pulp chamber in younger teeth, and segmentation of pulp cavities into multiple separate pulp entities within the same tooth with increasing age. A common pulp chamber was identified in 55.3% (26/47) of teeth with a mean dental age of 1 year and 11 months (± 1 year and 8 months). Columnar segmentation was recorded in the remaining teeth with a mean dental age of 6 years and 5 months (± 3 years and 11 months). Age of segmentation of the common pulp chamber into multiple separate pulp entities shows wide variation and is dependent of the specific Triadan position. The present study illustrates the presence of disto-mesial root contacts between adjacent tooth roots, often leading to morphological adaptations, most frequently observed between Triadan 09-10s (80%) and 10-11s (67%). The measured sub-occlusal dentinal thickness was as low as 1.11 mm over some pulp horns. The sub-occlusal dentinal thickness was lower than 2, 3, and 4 mm in 13.1, 38.1 and 61.4% of performed measurements, respectively. CONCLUSION: This study provides detailed information on age-dependent mandibular cheek teeth anatomy in alpacas, which may support the use and development of advanced dental treatments in this species such as endodontics and tooth sectioning techniques. Apical morphological adaptations caused by disto-mesial root contact between adjacent mandibular cheek teeth are clearly illustrated. The limited amount of sub-occlusal secondary dentin warrants a cautious approach with regards to dental floating in alpacas.
Assuntos
Camelídeos Americanos/anatomia & histologia , Mandíbula/diagnóstico por imagem , Dente/diagnóstico por imagem , Envelhecimento , Animais , Estudos Transversais , Feminino , Masculino , Mandíbula/anatomia & histologia , Microtomografia por Raio-X/veterináriaRESUMO
Photon counting X-ray imagers have found their way into the mainstream scientific community in recent years, and have become important components in many scientific setups. These camera systems are in active development, with output data rates increasing significantly with every new generation of devices. A different class of PCD (Photon Counting Detector) devices has become generally available, where camera data output is no longer a matrix of photon counts but instead direct measurements of the deposited charge per pixel in every frame, which requires significant off-camera processing. This type of PCD, called a hyperspectral X-ray camera due to its fully spectroscopic output, yet again increases the demands put on the acquisition and processing backend. Not only are bandwidth requirements increased, but the need to do extensive data processing is also introduced with these hyperspectral PCD devices. To cope with these new developments the Spectral X-ray Imaging Data Acquisition framework (SpeXIDAQ) has been developed. All aspects of the imaging pipeline are handled by the SpeXIDAQ framework: from detector control and frame grabbing, to processing, storage and live visualisation during experiments.
RESUMO
Multilayer monochromator devices are commonly used at (imaging) beamlines of synchrotron facilities to shape the X-ray beam to relatively small bandwidth and high intensity. However, stripe artefacts are often observed and can deteriorate the image quality. Although the intensity distribution of these artefacts has been described in the literature, their spectral distribution is currently unknown. To assess the spatio-spectral properties of the monochromated X-ray beam, the direct beam has been measured for the first time using a hyperspectral X-ray detector. The results show a large number of spectral features with different spatial distributions for a [Ru,â B4C] strip monochromator, associated primarily with the higher-order harmonics of the undulator and monochromator. It is found that their relative contributions are sufficiently low to avoid an influence on the imaging data. The [V,â B4C] strip suppresses these high-order harmonics even more than the former, yet at the cost of reduced efficiency.
RESUMO
Pulmonary graft vs. host disease is a diverse and underestimated complication following allogenic hematopoietic stem cell transplantation. We aimed to compare the airway architecture with chronic lung allograft dysfunction post lung transplantation. Inflated explant lungs from graft vs. host disease patients were compared with lungs with chronic lung allograft dysfunction following lung transplantation, and control lungs using a combination of CT, microCT, and histology (n = 6 per group) and pathology in the (small) airways was further quantified and analyzed. Following allogenic hematopoietic stem cell transplantation, three patients presented as bronchiolitis obliterans syndrome and three patients showed interstitial changes and restriction. The CT analysis demonstrated a strong similarity between bronchiolitis obliterans syndrome after lung transplantation and post allogenic hematopoietic stem cell transplantation, evidenced by severe ( > 50%) airway obstruction from generation 9, with 70.8% of the airways ending in obstruction. Further analysis indicated that the airways either collapsed or accumulated matrix along a segment of the airway. In patients with restriction and interstitial changes following allogenic hematopoietic stem cell transplantation, the degree of airway obstruction was lower compared with bronchiolitis obliterans syndrome post allogenic hematopoietic stem cell transplantation, but similar to restrictive allograft syndrome post lung transplantation, showing a lower proportion of airway obstruction (20-35%), decreased number of terminal bronchioles per lung (p < 0.01), and parenchymal fibrosis. We observed similarities in the airway and parenchymal morphometric changes in lung graft vs. host disease and with chronic lung allograft dysfunction following lung transplantation, suggesting similar pathophysiological mechanisms.
Assuntos
Doença Enxerto-Hospedeiro/patologia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Pulmão/patologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
BACKGROUND AND AIMS: Tree rings, as archives of the past and biosensors of the present, offer unique opportunities to study influences of the fluctuating environment over decades to centuries. As such, tree-ring-based wood traits are capital input for global vegetation models. To contribute to earth system sciences, however, sufficient spatial coverage is required of detailed individual-based measurements, necessitating large amounts of data. X-ray computed tomography (CT) scanning is one of the few techniques that can deliver such data sets. METHODS: Increment cores of four different temperate tree species were scanned with a state-of-the-art X-ray CT system at resolutions ranging from 60 µm down to 4.5 µm, with an additional scan at a resolution of 0.8 µm of a splinter-sized sample using a second X-ray CT system to highlight the potential of cell-level scanning. Calibration-free densitometry, based on full scanner simulation of a third X-ray CT system, is illustrated on increment cores of a tropical tree species. KEY RESULTS: We show how multiscale scanning offers unprecedented potential for mapping tree rings and wood traits without sample manipulation and with limited operator intervention. Custom-designed sample holders enable simultaneous scanning of multiple increment cores at resolutions sufficient for tree ring analysis and densitometry as well as single core scanning enabling quantitative wood anatomy, thereby approaching the conventional thin section approach. Standardized X-ray CT volumes are, furthermore, ideal input imagery for automated pipelines with neural-based learning for tree ring detection and measurements of wood traits. CONCLUSIONS: Advanced X-ray CT scanning for high-throughput processing of increment cores is within reach, generating pith-to-bark ring width series, density profiles and wood trait data. This would allow contribution to large-scale monitoring and modelling efforts with sufficient global coverage.
Assuntos
Tomografia Computadorizada por Raios X , Madeira , Densitometria , Raios XRESUMO
A novel 3D elemental and morphological analysis approach is presented combining X-ray computed tomography (µCT), X-ray fluorescence (XRF) tomography, and confocal XRF analysis in a single laboratory instrument (Herakles). Each end station of Herakles (µCT, XRF-CT, and confocal XRF) represents the state-of-the-art of currently available laboratory techniques. The integration of these techniques enables linking the (quantitative) spatial distribution of chemical elements within the investigated materials to their three-dimensional (3D) internal morphology/structure down to 1-10 µm resolution level, which has not been achieved so-far using laboratory X-ray techniques. The concept of Herakles relies strongly on its high precision (around 100 nm) air-bearing motor system that connects the different end-stations, allowing combined measurements based on the above X-ray techniques while retaining the coordinate system. In-house developed control and analysis software further ensures a smooth integration of the techniques. Case studies on a Cu test pattern, a Daphnia magna model organism and a perlite biocatalyst support material demonstrate the attainable resolution, elemental sensitivity of the instrument, and the strength of combining these three complementary methodologies.
RESUMO
In this work, the three-dimensional elemental distribution profile within the freshwater crustacean Ceriodaphnia dubia was constructed at a spatial resolution down to 5 µm via a data fusion approach employing state-of-the-art laser ablation-inductively coupled plasma-time-of-flight mass spectrometry (LA-ICP-TOFMS) and laboratory-based absorption microcomputed tomography (µ-CT). C. dubia was exposed to elevated Cu, Ni, and Zn concentrations, chemically fixed, dehydrated, stained, and embedded, prior to µ-CT analysis. Subsequently, the sample was cut into 5 µm thin sections that were subjected to LA-ICP-TOFMS imaging. Multimodal image registration was performed to spatially align the 2D LA-ICP-TOFMS images relative to the corresponding slices of the 3D µ-CT reconstruction. Mass channels corresponding to the isotopes of a single element were merged to improve the signal-to-noise ratios within the elemental images. In order to aid the visual interpretation of the data, LA-ICP-TOFMS data were projected onto the µ-CT voxels representing tissue. Additionally, the image resolution and elemental sensitivity were compared to those obtained with synchrotron radiation based 3D confocal µ-X-ray fluorescence imaging upon a chemically fixed and air-dried C. dubia specimen.
Assuntos
Imageamento Tridimensional , Imagem Multimodal , Animais , Cladocera , Cobre/análise , Terapia a Laser , Espectrometria de Massas , Níquel/análise , Distribuição Tecidual , Microtomografia por Raio-X , Zinco/análiseRESUMO
Incubation of Norway spruce with Physisporinus vitreus and sycamore with Xylaria longipes results in reduction in density of these wood species that are traditionally used for the top and bottom plate of a violin, which follows by enhanced acoustic properties. We used Synchrotron X-ray micro-tomography, to study the three-dimensional structure of wood at the micro-scale level and the alterations of the density distribution after incubation with two white-rot fungi. Micro-tomography data from wood treated at different incubation periods are analyzed and compared with untreated (control) specimens to determine the wood density map and changes at the cell-wall level. Differences between the density of early- and latewood, xylem ray and around bordered pits in both Norway spruce and sycamore are studied. Three-dimensional hyphal networks of the P.vitreus and Xylaria longipes hyphae are visualized inside the cell lumina and their significance on the density of the early- and latewood cells after different incubation periods are discussed. The study illustrates the utility of X-ray micro-tomography for both qualitative and quantitative studies of a wide variety of biological systems and due to its high sensitivity, small structural changes can be quantified.
Assuntos
Parede Celular/ultraestrutura , Picea/química , Madeira/ultraestrutura , Parede Celular/química , Parede Celular/microbiologia , Picea/microbiologia , Picea/ultraestrutura , Polyporaceae/química , Polyporaceae/patogenicidade , Síncrotrons , Madeira/química , Madeira/microbiologia , Microtomografia por Raio-X , Xylariales/química , Xylariales/patogenicidadeRESUMO
Steel production is one of the largest contributors to industrial CO2 emissions. This industry also generates large amounts of solid byproducts, such as slag and sludge. In this study, fine grained stainless-steel slag (SSS) is valorized to produce compacts with high compressive strength without the use of a hydraulic binder. This carbonation process is investigated on a pore-scale level to identify how the mineral phases in the SSS react with CO2, where carbonates are formed, and what the impact of these changes is on the pore network of the carbonated SSS compact. In addition to conventional research techniques, high-resolution X-ray computed tomography (HRXCT) is applied to visualize and quantify the changes in situ during the carbonation process. The results show that carbonates mainly precipitate at grain contacts and in capillary pores and this precipitation has little effect on the connectivity of the pore space. This paper also demonstrates the use of a custom-designed polymer reaction cell that allows in situ HRXCT analysis of the carbonation process. This shows the distribution and influence of water and CO2 in the pore network on the carbonate precipitation and, thus, the influence on the compressive strength development of the waste material.
Assuntos
Resíduos Industriais/análise , Aço Inoxidável/química , Tomografia Computadorizada por Raios X/métodos , Carbonatos/química , Cristalização , Microscopia Eletrônica de Varredura , Minerais , PorosidadeRESUMO
The multi-scale characterization of building materials is necessary to understand complex mechanical processes, with the goal of developing new more sustainable materials. To that end, imaging methods are often used in materials science to characterize the microscale. However, these methods compromise the volume of interest to achieve a higher resolution. Dark-field (DF) contrast imaging is being investigated to characterize building materials in length scales smaller than the resolution of the imaging system, allowing a direct comparison of features in the nano-scale range and overcoming the scale limitations of the established characterization methods. This work extends the implementation of a dual-phase X-ray grating interferometer (DP-XGI) for DF imaging in a lab-based setup. The interferometer was developed to operate at two different design energies of 22.0 keV and 40.8 keV and was designed to characterize nanoscale-size features in millimeter-sized material samples. The good performance of the interferometer in the low energy range (LER) is demonstrated by the DF retrieval of natural wood samples. In addition, a high energy range (HER) configuration is proposed, resulting in higher mean visibility and good sensitivity over a wider range of correlation lengths in the nanoscale range. Its potential for the characterization of mineral building materials is illustrated by the DF imaging of a Ketton limestone. Additionally, the capability of the DP-XGI to differentiate features in the nanoscale range is proven with the dark-field of Silica nanoparticles at different correlation lengths of calibrated sizes of 106 nm, 261 nm, and 507 nm.