Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Int J Radiat Oncol Biol Phys ; 68(1): 273-81, 2007 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-17448880

RESUMO

PURPOSE: To demonstrate the feasibility of registering hyperpolarized helium-3 magnetic resonance images ((3)He-MRI) to X-ray computed tomography (CT) for functionally weighted intensity-modulated radiotherapy (IMRT) planning. METHODS AND MATERIALS: Six patients with non-small-cell lung cancer underwent (3)He ventilation MRI, which was fused with radiotherapy planning CT using rigid registration. Registration accuracy was assessed using an overlap coefficient, calculated as the proportion of the segmented (3)He-MR volume (V(MRI)) that intersects the segmented CT lung volume expressed as a percentage of V(MRI). For each patient, an IMRT plan that minimized the volume of total lung receiving a dose > or = 20 Gy (V(20)) was compared with a plan that minimized the V(20) to well-ventilated lung defined by the registered (3)He-MRI. RESULTS: The (3)He-MRI and CT were registered with sufficient accuracy to enable functionally guided IMRT planning (median overlap, 89%; range, 72-97%). In comparison with the total lung IMRT plans, IMRT constrained with (3)He-MRI reduced the V(20) not only for the well-ventilated lung (median reduction, 3.1%; range, 0.4-5.1%; p = 0.028) but also for the total lung volume (median reduction, 1.6%; range, 0.2-3.7%; p = 0.028). CONCLUSIONS: Statistically significant improvements to IMRT plans are possible using functional information provided by (3)He-MRI that has been registered to radiotherapy planning CT.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X/métodos , Obstrução das Vias Respiratórias/diagnóstico , Obstrução das Vias Respiratórias/etiologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Hélio , Humanos , Isótopos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino
2.
Phys Med Biol ; 62(17): 7114-7130, 2017 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-28800298

RESUMO

To investigate the effect of beam angles and field number on functionally-guided intensity modulated radiotherapy (IMRT) normal lung avoidance treatment plans that incorporate hyperpolarised helium-3 magnetic resonance imaging (3He MRI) ventilation data. Eight non-small cell lung cancer patients had pre-treatment 3He MRI that was registered to inspiration breath-hold radiotherapy planning computed tomography. IMRT plans that minimised the volume of total lung receiving ⩾20 Gy (V20) were compared with plans that minimised 3He MRI defined functional lung receiving ⩾20 Gy (fV20). Coplanar IMRT plans using 5-field manually optimised beam angles and 9-field equidistant plans were also evaluated. For each pair of plans, the Wilcoxon signed ranks test was used to compare fV20 and the percentage of planning target volume (PTV) receiving 90% of the prescription dose (PTV90). Incorporation of 3He MRI led to median reductions in fV20 of 1.3% (range: 0.2-9.3%; p = 0.04) and 0.2% (range: 0 to 4.1%; p = 0.012) for 5- and 9-field arrangements, respectively. There was no clinically significant difference in target coverage. Functionally-guided IMRT plans incorporating hyperpolarised 3He MRI information can reduce the dose received by ventilated lung without comprising PTV coverage. The effect was greater for optimised beam angles rather than uniformly spaced fields.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Neoplasias Pulmonares/radioterapia , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Feminino , Hélio/metabolismo , Humanos , Isótopos/metabolismo , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA