Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Vet Res Commun ; 47(2): 987-997, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36445603

RESUMO

Bovine brucellosis is a disease that significantly impacts animal production and human health. Although many sensitive diagnostic tests are used, there is still no ideal fast serological test for all epidemiological situations. In this context, we developed peptides that mimic regions of antigenic proteins of Brucella abortus and can be used in serological diagnosis. RESULTS: From phage display technology, we randomly selected nine clones of phage displaying peptide binders to B. abortus. These clones were sequenced and translated. After molecular docking analysis, two peptides (Ba4 and Ba9) were selected, chemically synthesized, and verified for their potential diagnostic value. By enzyme-linked immunoassay (ELISA), Ba9 showed a sensitivity of up to 97.5% to detect antibodies circulating in animals with brucellosis. We incorporated the peptide Ba9 onto a bioelectrode (graphite modified with poly-3-hydroxyphenylacetic acid). Then, direct serum detection was demonstrated by differential pulse voltammetry, micrographs, and topographic analyses in addition to the average roughness coefficient (Ra) and the value of the mean squared deviation of the roughness (Rms). CONCLUSION: This work shows that the mimetic epitope of B. abortus can be useful for developing new platforms for diagnosing brucellosis. In addition, we propose a fast test based on an electrochemical sensor using graphite modified with poly-3-hydroxyphenylacetic acid.


Assuntos
Brucelose , Doenças dos Bovinos , Grafite , Humanos , Animais , Bovinos , Brucella abortus , Epitopos , Simulação de Acoplamento Molecular , Ensaio de Imunoadsorção Enzimática/veterinária , Brucelose/veterinária , Anticorpos Antibacterianos , Doenças dos Bovinos/diagnóstico
2.
Appl Biochem Biotechnol ; 194(6): 2604-2619, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35182331

RESUMO

In this work, we report the construction of a novel electrochemical device for molecular diagnosis of hepatitis B virus in the blood plasma of infected patients, using graphite electrodes functionalized with poly(4-aminophenol) and sensitized with a specific DNA probe. The recognition of genomic DNA was evaluated by electrochemical techniques (DPV and EIS) and scanning electron microscopy. The genosensor was efficient in detecting genomic DNA with a linear range from 1.176 to 4.825 µg mL-1 and detection limit of 35.69 ng mL-1 (4.63 IU ml-1 or 25.93 copies.ml-1), which is better than the 10.00 IU ml-1 limit of reference method, real-time PCR, used in point of care. EIS analysis shows that the genosensor resistance increased exponentially with the concentration of the genomic DNA target. This novel platform has advantages to its applicability in real samples, such as good sensitivity, selectivity, low sample volume, and fast assay time (36 min), thus interesting for application in the diagnosis of hepatitis B virus in blood plasma. Also, the ease of synthesis of the low-cost polymer by electrosynthesis directly on the electrode surface allows the translation of the platform to portable devices.


Assuntos
Técnicas Biossensoriais , Grafite , Hepatite B , Técnicas Biossensoriais/métodos , DNA/química , Técnicas Eletroquímicas/métodos , Eletrodos , Grafite/química , Hepatite B/diagnóstico , Vírus da Hepatite B/genética , Humanos , Limite de Detecção , Plasma
3.
Crit Rev Immunol ; 30(2): 201-22, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20370630

RESUMO

Nanotechnological tools and biomarkers for diagnosis and prognosis, as well as strategies for disease control and monitoring populations at higher risk, are continuous worldwide challenges for infectious diseases. Phage display and monoclonal antibody combinatorial libraries are important sources for biomarker discovery and for improved diagnostic strategies. Mimetic peptides were selected against polyclonal antibodies from patients with dengue fever, leprosy, and leishmaniasis as model diseases, and from immunized chickens with total antigens from all three pathogens. Selected single or combined multi-epitope peptide biomarkers were further associated with four different sensor platforms, classified as affinity biosensors, that may be suitable as general protocols for field diagnosis. We have also developed two methods for nanoparticle agglutination assays (a particle gel agglutination test and a magnetic microparticle [MMP]-enzyme-linked immunosorbent assay [ELISA]) and two electrochemical biosensors (impedimetric and amperometric) for DNA and antibody detection. For the agglutination tests, micro- and nanoparticles were coupled with filamentous bacteriophages displaying the selected mimotopes on their surfaces, which has favored the formation of the antigen-antibody or peptide-protein complexes, amplifying the optical detection in ELISA assays or after the chromatographic separation of the microagglutinates. We have also demonstrated a proof-of-concept for the electrochemical biosensors by using electrodes modified with novel functionalized polymers. These electrochemical biosensors have proven to be fast, very sensitive, and specific for the detection of pathogen DNA and circulating antibodies of patients, which may become important in a wide range of diagnostic devices for many infectious agents.


Assuntos
Técnicas Biossensoriais/métodos , Doenças Transmissíveis/sangue , Doenças Transmissíveis/diagnóstico , Nanotecnologia/métodos , Biomarcadores/sangue , Técnicas Biossensoriais/tendências , Doenças Transmissíveis/imunologia , Ensaio de Imunoadsorção Enzimática , Humanos , Nanopartículas , Nanotecnologia/tendências
4.
Front Microbiol ; 11: 429, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32256479

RESUMO

Phenolic glycolipid I (PGL-I) is an abundant antigen on the Mycobacterium leprae cell wall, commonly used for operational classification of leprosy patients. Our aim was to develop PGL-I mimotopes with similar characteristics and functions of the native antigen. We have used a random peptide phage display (PD) library for selections against the monoclonal antibody anti-PGL-I. After three selection cycles, six peptides were identified. All sequences were interspersed by a spacer generating a chimeric peptide (PGLI-M3) that was artificially synthesized. The highly reactive peptide was submitted to a reverse PD selection with a single-chain Fv (scFv) antibody fragment combinatorial library. The most reactive scFv was then validated by enzyme-linked immunosorbent assay (ELISA) against both native PGL-I and two derived synthetic (NDO and ND-O-HSA). We have further proved the scFv specificity by detecting M. leprae bacilli in leprosy lesions through immunohistochemistry. We then described its applicability in ELISA for all clinical forms and household contacts (HC). Afterward, we showed differential binding affinities of PGLI-M3 to sera (anti-PGL-I IgM) from all leprosy clinical forms through surface plasmon resonance (SPR). ELISA IgM detection showed 89.1% sensitivity and 100% specificity, considering all clinical forms. Positivity for anti-PGL-I IgM was twofold higher in both HC and patients with paucibacillary forms in hyperendemic regions than in endemic ones. The SPR immunosensor was able to differentiate clinical forms with 100% accuracy. This is the first time that a PGL-I mimotope has efficiently mimicked the carbohydrate group of the M. leprae antigen with successful immunoassay applications and may become a substitute for the native antigen.

5.
Braz. arch. biol. technol ; 64: e21210030, 2021. graf
Artigo em Inglês | LILACS | ID: biblio-1339317

RESUMO

Abstract Nowadays, a prompt and reliable diagnosis is one of the most critical measures for leprosy control. The current diagnostic is based on clinical exams by a health care professional, and it may not recognize early signs of the disease. Therefore, other leprosy diagnosis methods are needed that are sensitive, disease-specific, and easy to deliver to the end-user. This study describes the construction of an electrochemical DNA biosensor to detect PCR products of Mycobacterium leprae using methylene blue as an indicator of the hybridization. The capture probe was immobilized on the graphite electrode modified with poly(4-aminophenol). The electrode surface was morphologically characterized by atomic force microscopy. Linear voltammetry was used to monitor the concentration of methylene blue on the DNA biosensor, which indicated a limit detection of 1 x 10-10 mol/L. The biosensor showed selective when placed to hybridize with a non-complementary sequence. This study suggests that the electrochemical DNA biosensor developed is promising for detecting DNA of Mycobacterium leprae.


Assuntos
Técnicas Biossensoriais , Aminofenóis , Azul de Metileno , Mycobacterium leprae
8.
Braz. arch. biol. technol ; 54(6): 1217-1222, Nov.-Dec. 2011. ilus, tab
Artigo em Inglês | LILACS | ID: lil-608444

RESUMO

The properties of poly(4-aminophenol) modified graphite electrode as material for the immobilization of acetylcholinesterase were investigated by the Cyclic Voltammetry, Electrochemical Impedance Spectroscopy and Atomic Force Microscopy. The polymer was deposited on graphite electrode surface by the oxidation of 4-aminophenol and then acetylcholinesterase was immobilized on the surface of the electrode. The biosensor coupled in the continuous flow system was employed for the detection of dichlorvos. The detection and quantification limits were 0.8 and 2.4 μmol L-1 dichlorvos, respectively. Graphite electrodes modified with the poly(4-aminophenol) showed to be an efficient and promising material for immobilization of acetylcholinesterase enzyme. The proposed method requires simple parts which are easy to build, involves only one biosensor and the potentiometric detection is simple.

9.
Virology ; 325(1): 82-95, 2004 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-15231388

RESUMO

The central genomic regions of Oenococcus oeni phages fOg30 and fOgPSU1 have been compared with the equivalent regions of oenophages fOg44 and phi 10MC. In all cases, an almost identical endolysin gene was followed by one of two orfs, encoding putative holins (orf117 and orf163). The fOg44 endolysin was established as a secretory protein when expressed in Lactococcus lactis. Orf117 (from fOg44) promoted lysis of Escherichia coli cultures upon induction of a defective lambda Sam7 prophage, but Orf163 (from fOg30) failed to elicit a lysis response in this system. fOg44 and fOgPSU1 were shown to integrate at the 3' end of a tRNA(Glu) and a tRNA(Lys), respectively. Searching the available sequence of the O. oeni MCW genome for attP-like elements, two other tRNA targets could be proposed for prophage establishment. Between the lysis and integration elements, a diverse cluster of genes (absent in phi 10MC) was observed. One common gene in this "lysogenic conversion cluster" was experimentally confirmed as a transcriptional repressor, affecting the expression of a putative permease gene.


Assuntos
Bacteriófagos/genética , Genoma Viral , Cocos Gram-Positivos/virologia , RNA de Transferência/genética , Integração Viral , Sequência de Aminoácidos , Sequência de Bases , Endopeptidases/metabolismo , Leuconostoc/virologia , Lisogenia , Dados de Sequência Molecular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA