Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 130
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Nucl Med Mol Imaging ; 51(4): 1050-1059, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37975887

RESUMO

PURPOSE: Accurate preoperative localization is imperative to guide surgery in primary hyperparathyroidism (pHPT). It remains unclear which second-line imaging technique is most effective after negative first-line imaging. In this study, we compare the diagnostic effectiveness of [11C]methionine PET/CT, [11C]choline PET/CT, and four dimensional (4D)-CT head-to-head in patients with pHPT, to explore which of these imaging techniques to use as a second-line scan. METHODS: We conducted a powered, prospective, blinded cohort study in patients with biochemically proven pHPT and prior negative or discordant first-line imaging consisting of ultrasonography and 99mTc-sestamibi. All patients underwent [11C]methionine PET/CT, [11C]choline PET/CT, and 4D-CT. At first, all scans were interpreted by a nuclear medicine physician, and a radiologist who were blinded from patient data and all imaging results. Next, a non-blinded scan reading was performed. The scan results were correlated with surgical and histopathological findings. Serum calcium values at least 6 months after surgery were used as gold standard for curation of HPT. RESULTS: A total of 32 patients were included in the study. With blinded evaluation, [11C]choline PET/CT was positive in 28 patients (88%), [11C]methionine PET/CT in 23 (72%), and 4D-CT in 15 patients (47%), respectively. In total, 30 patients have undergone surgery and 32 parathyroid lesions were histologically confirmed as parathyroid adenomas. Based on the blinded evaluation, lesion-based sensitivity of [11C]choline PET/CT, [11C]methionine PET/CT, and 4D-CT was respectively 85%, 67%, and 39%. The sensitivity of [11C]choline PET/CT differed significantly from that of [11C]methionine PET/CT and 4D-CT (p = 0.031 and p < 0.0005, respectively). CONCLUSION: In the setting of pHPT with negative first-line imaging, [11C]choline PET/CT is superior to [11C]methionine PET/CT and 4D-CT in localizing parathyroid adenomas, allowing correct localization in 85% of adenomas. Further studies are needed to determine cost-benefit and efficacy of these scans, including the timing of these scans as first- or second-line imaging techniques.


Assuntos
Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Humanos , Neoplasias das Paratireoides/complicações , Neoplasias das Paratireoides/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/cirurgia , Metionina , Colina , Estudos de Coortes , Estudos Prospectivos , Glândulas Paratireoides , Tecnécio Tc 99m Sestamibi , Racemetionina
2.
Eur J Nucl Med Mol Imaging ; 50(8): 2258-2270, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-36947185

RESUMO

PURPOSE: Monoclonal antibody (mAb)-based PET (immunoPET) imaging can characterise tumour lesions non-invasively. It may be a valuable tool to determine which patients may benefit from treatment with a specific monoclonal antibody (mAb) and evaluate treatment response. For 89Zr immunoPET imaging, higher sensitivity of state-of-the art PET/CT systems equipped with silicon photomultiplier (SiPM)-based detector elements may be beneficial as the low positron abundance of 89Zr causes a low signal-to-noise level. Moreover, the long physical half-life limits the amount of activity that can be administered to the patients leading to poor image quality even when using long scan durations. Here, we investigated the difference in semiquantitative performance between the PMT-based Biograph mCT, our clinical reference system, and the SiPM-based Biograph Vision PET/CT in 89Zr immunoPET imaging. Furthermore, the effects of scan duration reduction using the Vision on semiquantitative imaging parameters and its influence on image quality assessment were evaluated. METHODS: Data were acquired on day 4 post 37 MBq 89Zr-labelled mAb injection. Five patients underwent a double scan protocol on both systems. Ten patients were scanned only on the Vision. For PET image reconstruction, three protocols were used, i.e. one camera-dependent protocol and European Association of Nuclear Medicine Research Limited (EARL) standards 1 and 2 compliant protocols. Vision data were acquired in listmode and were reprocessed to obtain images at shorter scan durations. Semiquantitative PET image parameters were derived from tumour lesions and healthy tissues to assess differences between systems and scan durations. Differently reconstructed images obtained using the Vision were visually scored regarding image quality by two nuclear medicine physicians. RESULTS: When images were reconstructed using 100% acquisition time on both systems following EARL standard 1 compliant reconstruction protocols, results regarding semiquantification were comparable. For Vision data, reconstructed images that conform to EARL1 standards still resulted in comparable semiquantification at shorter scan durations (75% and 50%) regarding 100% acquisition time. CONCLUSION: Scan duration of 89Zr immunoPET imaging using the Vision can be decreased up to 50% compared with using the mCT while maintaining image quality using the EARL1 compliant reconstruction protocol.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Neoplasias/diagnóstico por imagem , Padrões de Referência , Anticorpos Monoclonais , Tomografia por Emissão de Pósitrons/métodos , Processamento de Imagem Assistida por Computador
3.
Eur J Nucl Med Mol Imaging ; 50(9): 2736-2750, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37039901

RESUMO

PURPOSE: Patient-tailored management of thyroid nodules requires improved risk of malignancy stratification by accurate preoperative nodule assessment, aiming to personalize decisions concerning diagnostics and treatment. Here, we perform an exploratory pilot study to identify possible patterns on multispectral optoacoustic tomography (MSOT) for thyroid malignancy stratification. For the first time, we directly correlate MSOT images with histopathology data on a detailed level. METHODS: We use recently enhanced data processing and image reconstruction methods for MSOT to provide next-level image quality by means of improved spatial resolution and spectral contrast. We examine optoacoustic features in thyroid nodules associated with vascular patterns and correlate these directly with reference histopathology. RESULTS: Our methods show the ability to resolve blood vessels with diameters of 250 µm at depths of up to 2 cm. The vessel diameters derived on MSOT showed an excellent correlation (R2-score of 0.9426) with the vessel diameters on histopathology. Subsequently, we identify features of malignancy observable in MSOT, such as intranodular microvascularity and extrathyroidal extension verified by histopathology. Despite these promising features in selected patients, we could not determine statistically relevant differences between benign and malignant thyroid nodules based on mean oxygen saturation in thyroid nodules. Thus, we illustrate general imaging artifacts of the whole field of optoacoustic imaging that reduce image fidelity and distort spectral contrast, which impedes quantification of chromophore presence based on mean concentrations. CONCLUSION: We recommend examining optoacoustic features in addition to chromophore quantification to rank malignancy risk. We present optoacoustic images of thyroid nodules with the highest spatial resolution and spectral contrast to date, directly correlated to histopathology, pushing the clinical translation of MSOT.


Assuntos
Técnicas Fotoacústicas , Nódulo da Glândula Tireoide , Humanos , Nódulo da Glândula Tireoide/diagnóstico por imagem , Projetos Piloto , Técnicas Fotoacústicas/métodos , Tomografia/métodos , Tomografia Computadorizada por Raios X
4.
Eur J Nucl Med Mol Imaging ; 49(6): 1970-1984, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34981165

RESUMO

PURPOSE: To assess the impact of an [18F]FDG-PET/CT-driven diagnostic workup to rule out malignancy, avoid futile diagnostic surgeries, and improve patient outcomes in thyroid nodules with indeterminate cytology. METHODS: In this double-blinded, randomised controlled multicentre trial, 132 adult euthyroid patients with scheduled diagnostic surgery for a Bethesda III or IV thyroid nodule underwent [18F]FDG-PET/CT and were randomised to an [18F]FDG-PET/CT-driven or diagnostic surgery group. In the [18F]FDG-PET/CT-driven group, management was based on the [18F]FDG-PET/CT result: when the index nodule was visually [18F]FDG-positive, diagnostic surgery was advised; when [18F]FDG-negative, active surveillance was recommended. The nodule was presumed benign when it remained unchanged on ultrasound surveillance. In the diagnostic surgery group, all patients were advised to proceed to the scheduled surgery, according to current guidelines. The primary outcome was the fraction of unbeneficial patient management in one year, i.e., diagnostic surgery for benign nodules and active surveillance for malignant/borderline nodules. Intention-to-treat analysis was performed. Subgroup analyses were performed for non-Hürthle cell and Hürthle cell nodules. RESULTS: Patient management was unbeneficial in 42% (38/91 [95% confidence interval [CI], 32-53%]) of patients in the [18F]FDG-PET/CT-driven group, as compared to 83% (34/41 [95% CI, 68-93%]) in the diagnostic surgery group (p < 0.001). [18F]FDG-PET/CT-driven management avoided 40% (25/63 [95% CI, 28-53%]) diagnostic surgeries for benign nodules: 48% (23/48 [95% CI, 33-63%]) in non-Hürthle cell and 13% (2/15 [95% CI, 2-40%]) in Hürthle cell nodules (p = 0.02). No malignant or borderline tumours were observed in patients under surveillance. Sensitivity, specificity, negative and positive predictive value, and benign call rate (95% CI) of [18F]FDG-PET/CT were 94.1% (80.3-99.3%), 39.8% (30.0-50.2%), 95.1% (83.5-99.4%), 35.2% (25.4-45.9%), and 31.1% (23.3-39.7%), respectively. CONCLUSION: An [18F]FDG-PET/CT-driven diagnostic workup of indeterminate thyroid nodules leads to practice changing management, accurately and oncologically safely reducing futile surgeries by 40%. For optimal therapeutic yield, application should be limited to non-Hürthle cell nodules. TRIAL REGISTRATION NUMBER: This trial is registered with ClinicalTrials.gov: NCT02208544 (5 August 2014), https://clinicaltrials.gov/ct2/show/NCT02208544 .


Assuntos
Neoplasias da Glândula Tireoide , Nódulo da Glândula Tireoide , Adulto , Fluordesoxiglucose F18 , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Tomografia Computadorizada por Raios X
5.
Eur J Nucl Med Mol Imaging ; 49(13): 4652-4660, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35876867

RESUMO

PURPOSE: Current European Association of Nuclear Medicine (EANM) Research Ltd. (EARL) guidelines for the standardisation of PET imaging developed for conventional systems have not yet been adjusted for long axial field-of-view (LAFOV) systems. In order to use the LAFOV Siemens Biograph Vision Quadra PET/CT (Siemens Healthineers, Knoxville, TN, USA) in multicentre research and harmonised clinical use, compliance to EARL specifications for 18F-FDG tumour imaging was explored in the current study. Additional tests at various locations throughout the LAFOV and the use of shorter scan durations were included. Furthermore, clinical data were collected to further explore and validate the effects of reducing scan duration on semi-quantitative PET image biomarker accuracy and precision when using EARL-compliant reconstruction settings. METHODS: EARL compliance phantom measurements were performed using the NEMA image quality phantom both in the centre and at various locations throughout the LAFOV. PET data (maximum ring difference (MRD) = 85) were reconstructed using various reconstruction parameters and reprocessed to obtain images at shorter scan durations. Maximum, mean and peak activity concentration recovery coefficients (RC) were obtained for each sphere and compared to EARL standards specifications. Additionally, PET data (MRD = 85) of 10 oncological patients were acquired and reconstructed using various reconstruction settings and reprocessed from 10 min listmode acquisition into shorter scan durations. Per dataset, SUVs were derived from tumour lesions and healthy tissues. ANOVA repeated measures were performed to explore differences in lesion SUVmax and SUVpeak. Wilcoxon signed-rank tests were performed to evaluate differences in background SUVpeak and SUVmean between scan durations. The coefficient of variation (COV) was calculated to characterise noise. RESULTS: Phantom measurements showed EARL compliance for all positions throughout the LAFOV for all scan durations. Regarding patient data, EARL-compliant images showed no clinically meaningful significant differences in lesion SUVmax and SUVpeak or background SUVmean and SUVpeak between scan durations. Here, COV only varied slightly. CONCLUSION: Images obtained using the Vision Quadra PET/CT comply with EARL specifications. Scan duration and/or activity administration can be reduced up to a factor tenfold without the interference of increased noise.


Assuntos
Neoplasias , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Fluordesoxiglucose F18 , Imagens de Fantasmas , Biomarcadores
6.
Ann Surg ; 274(6): e659-e663, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34145192

RESUMO

OBJECTIVE: This study aims to generate a reproducible and generalizable Workflow model of ICG-angiography integrating Standardization and Quantification (WISQ) that can be applied uniformly within the surgical innovation realm independent of the user. SUMMARY BACKGROUND DATA: Tissue perfusion based on indocyanine green (ICG)-angiography is a rapidly growing application in surgical innovation. Interpretation of results has been subjective and error-prone due to the lack of a standardized and quantitative ICG-workflow and analytical methodology. There is a clinical need for a more generic, reproducible, and quantitative ICG perfusion model for objective assessment of tissue perfusion. METHODS: In this multicenter, proof-of-concept study, we present a generic and reproducible ICG-workflow integrating standardization and quantification for perfusion assessment. To evaluate our model's clinical feasibility and reproducibility, we assessed the viability of parathyroid glands after performing thyroidectomy. Biochemical hypoparathyroidism was used as the postoperative endpoint and its correlation with ICG quantification intraoperatively. Parathyroid gland is an ideal model as parathyroid function post-surgery is only affected by perfusion. RESULTS: We show that visual subjective interpretation of ICG-angiography by experienced surgeons on parathyroid perfusion cannot reliably predict organ function impairment postoperatively, emphasizing the importance of an ICG quantification model. WISQ was able to standardize and quantify ICG-angiography and provided a robust and reproducible perfusion curve analysis. A low ingress slope of the perfusion curve combined with a compromised egress slope was indicative for parathyroid organ dysfunction in 100% of the cases. CONCLUSION: WISQ needs prospective validation in larger series and may eventually support clinical decision-making to predict and prevent postoperative organ function impairment in a large and varied surgical population.


Assuntos
Angiografia/normas , Verde de Indocianina , Glândulas Paratireoides/irrigação sanguínea , Glândulas Paratireoides/diagnóstico por imagem , Tireoidectomia/normas , Fluxo de Trabalho , Estudos de Viabilidade , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/prevenção & controle , Estudo de Prova de Conceito , Estudos Prospectivos , Reprodutibilidade dos Testes
7.
Eur J Nucl Med Mol Imaging ; 48(5): 1498-1510, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33099667

RESUMO

PURPOSE: Metabolically active tumour volume (MATV) is a potential quantitative positron emission tomography (PET) imaging biomarker in melanoma. Accumulating data indicate that low MATV may predict increased chance of response to immunotherapy and overall survival. However, metastatic melanoma can present with numerous (small) tumour lesions, making manual tumour segmentation time-consuming. The aim of this study was to evaluate multiple semi-automatic segmentation workflows to determine reliability and reproducibility of MATV measurements in patients with metastatic melanoma. METHODS: An existing cohort of 64 adult patients with histologically proven metastatic melanoma was used in this study. 18F-FDG PET/CT diagnostic baseline images were acquired using a European Association of Nuclear Medicine (EANM) Research Limited-accredited Siemens Biograph mCT PET/CT system (Siemens Healthineers, Knoxville, USA). PET data were analysed using manual, gradient-based segmentation and five different semi-automatic methods: three direct PET image-derived delineations (41MAX, A50P and SUV40) and two based on a majority-vote approach (MV2 and MV3), without and with (suffix '+') manual lesion addition. Correlation between the different segmentation methods and their respective associations with overall survival was assessed. RESULTS: Correlation between the MATVs derived by the manual segmentation and semi-automated tumour segmentations ranged from R2 = 0.41 for A50P to R2 = 0.85 for SUV40+ and MV2+, respectively. Manual MATV segmentation did not differ significantly from the semi-automatic methods SUV40 (∆MATV mean ± SD 0.08 ± 0.60 mL, P = 0.303), SUV40+ (∆MATV - 0.10 ± 0.51 mL, P = 0.126), MV2+ (∆MATV - 0.09 ± 0.62 mL, P = 0.252) and MV3+ (∆MATV - 0.03 ± 0.55 mL, P = 0.615). Log-rank tests showed statistically significant overall survival differences between above and below median MATV patients for all segmentation methods with areas under the ROC curves of 0.806 for manual segmentation and between 0.756 [41MAX] and 0.807 [MV3+] for semi-automatic segmentations. CONCLUSIONS: Simple and fast semi-automated FDG PET segmentation workflows yield accurate and reproducible MATV measurements that correlate well with manual segmentation in metastatic melanoma. The most readily applicable and user-friendly SUV40 method allows feasible MATV measurement in prospective multicentre studies required for validation of this potential PET imaging biomarker for clinical use.


Assuntos
Melanoma , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Fluordesoxiglucose F18 , Humanos , Melanoma/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Carga Tumoral , Fluxo de Trabalho
8.
Am J Transplant ; 19(7): 2116-2121, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30868732

RESUMO

Secondary protein-losing enteropathy (PLE) is a rare complication following pediatric liver transplantation (LT), mostly related to venous outflow obstruction of the liver. Here, we discuss a thus far unknown cause of secondary PLE following pediatric LT. A 7-month-old boy underwent LT with biliary anastomosis using a Roux-en-Y jejunal loop. Eleven months later he developed PLE. Routine diagnostic workup was negative. No hepatic outflow obstruction was detected during catheterization. Although the hepatic venous pressure gradient was slightly increased (10 mm Hg), there were no clinical signs of portal hypertension. Albumin scintigraphy with specific early recordings suggested focal albumin intestinal entry in the jejunal Roux-en-Y loop. Local bacterial overgrowth or local lymphangiectasia, possibly due to (venous) congestion, was considered. Treatment with metronidazole did not improve albumin loss. Next, surgical revision of the jejunal Roux-en-Y loop was performed. The explanted loop contained a small abnormal area with a thin hyperemic mucosa, near the former anastomosis. Histopathological analysis showed changes both in the blood vessels and the lymphatic vessels with focal deeper chronic active inflammation resulting in congestion of vessels, hampering lymphatic outflow leading to lymphangiectasia and patchy distortion of lymphatic vessels. Following surgical revision, secondary PLE disappeared, up to now, 1.5 year post revision.


Assuntos
Anastomose em-Y de Roux/métodos , Encefalopatias/cirurgia , Hiperamonemia/cirurgia , Transplante de Fígado/efeitos adversos , Enteropatias Perdedoras de Proteínas/cirurgia , Encefalopatias/patologia , Humanos , Hiperamonemia/patologia , Lactente , Masculino , Prognóstico , Enteropatias Perdedoras de Proteínas/etiologia , Enteropatias Perdedoras de Proteínas/patologia , Recuperação de Função Fisiológica
9.
Eur J Nucl Med Mol Imaging ; 46(9): 1840-1849, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31209514

RESUMO

PURPOSE: In-vivo quantification of tumor uptake of 89-zirconium (89Zr)-labelled monoclonal antibodies (mAbs) with PET provides a potential tool in strategies to optimize tumor targeting and therapeutic efficacy. A specific challenge for 89Zr-immuno-PET is low tumor contrast. This is expected to result in interobserver variation in tumor delineation. Therefore, the aim of this study was to determine interobserver reproducibility of tumor uptake measures by tumor delineation on 89Zr-immuno-PET scans. METHODS: Data were obtained from previously published clinical studies performed with 89Zr-rituximab, 89Zr-cetuximab and 89Zr-trastuzumab. Tumor lesions on 89Zr-immuno-PET were identified as focal uptake exceeding local background by a nuclear medicine physician. Three observers independently manually delineated volumes of interest (VOI). Maximum, peak and mean standardized uptake values (SUVmax, SUVpeak and SUVmean) were used to quantify tumor uptake. Interobserver variability was expressed as the coefficient of variation (CoV). The performance of semi-automatic VOI delineation using 50% of background-corrected ACpeak was described. RESULTS: In total, 103 VOI were delineated (3-6 days post injection (D3-D6)). Tumor uptake (median, interquartile range) was 9.2 (5.2-12.6), 6.9 (4.0-9.6) and 5.5 (3.3-7.8) for SUVmax, SUVpeak and SUVmean. Interobserver variability was 0% (0-12), 0% (0-2) and 7% (5-14), respectively (n = 103). The success rate of the semi-automatic method was 45%. Inclusion of background was the main reason for failure of semi-automatic VOI. CONCLUSIONS: This study shows that interobserver reproducibility of tumor uptake quantification on 89Zr-immuno-PET was excellent for SUVmax and SUVpeak using a standardized manual procedure for tumor segmentation. Semi-automatic delineation was not robust due to limited tumor contrast.


Assuntos
Anticorpos Monoclonais/metabolismo , Linfoma de Células B/diagnóstico por imagem , Linfoma de Células B/metabolismo , Tomografia por Emissão de Pósitrons , Radioisótopos , Zircônio , Adulto , Idoso , Transporte Biológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Retrospectivos
10.
Eur J Nucl Med Mol Imaging ; 46(9): 1931-1939, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31172212

RESUMO

PURPOSE: The main objective of this preliminary analysis of the IMaging PAtients for Cancer drug selecTion (IMPACT)-renal cell cancer (RCC) study is to evaluate the lesion detection of baseline contrast-enhanced CT, [89Zr]Zr-DFO-girentuximab-PET/CT and [18F]FDG-PET/CT in detecting ccRCC lesions in patients with a good or intermediate prognosis metastatic clear cell renal cell carcinoma (mccRCC) according to the International Metastatic Database Consortium (IMDC) risk model. METHODS: Between February 2015 and March 2018, 42 newly diagnosed mccRCC patients with good or intermediate prognosis, eligible for watchful waiting, were included. Patients underwent CT, [89Zr]Zr-DFO-girentuximab-PET/CT and [18F]FDG-PET/CT at baseline. Scans were independently reviewed and lesions of ≥10 mm and lymph nodes of ≥15 mm at CT were analyzed. For lesions with [89Zr]Zr-DFO-girentuximab or [18F]FDG-uptake visually exceeding background uptake, maximum standardized uptake values (SUVmax) were measured. RESULTS: A total of 449 lesions were detected by ≥1 modality (median per patient: 7; ICR 4.25-12.75) of which 42% were in lung, 22% in lymph nodes and 10% in bone. Combined [89Zr]Zr-DFO-girentuximab-PET/CT and CT detected more lesions than CT alone: 91% (95%CI: 87-94) versus 56% (95%CI: 50-62, p = 0.001), respectively, and more than CT and [18F]FDG-PET/CT combined (84% (95%CI:79-88, p < 0.005). Both PET/CTs detected more bone and soft tissue lesions compared to CT alone. CONCLUSIONS: The addition of [89Zr]Zr-DFO-girentuximab-PET/CT and [18F]FDG-PET/CT to CT increases lesion detection compared to CT alone in newly diagnosed good and intermediate prognosis mccRCC patients eligible for watchful waiting.


Assuntos
Anticorpos Monoclonais/química , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/patologia , Fluordesoxiglucose F18 , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Monoclonais/metabolismo , Transporte Biológico , Carcinoma de Células Renais/metabolismo , Estudos de Coortes , Desferroxamina/química , Feminino , Fluordesoxiglucose F18/metabolismo , Humanos , Neoplasias Renais/metabolismo , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica
11.
J Surg Oncol ; 117(7): 1447-1454, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29484661

RESUMO

BACKGROUND: This feasibility study presents the results of a new intensive treatment regimen for locally advanced extremity soft tissue sarcomas (ESTS), consisting of hyperthermic isolated limb perfusion (HILP), preoperative external beam radiotherapy (EBRT), and surgical resection. METHODS: From 2011 to 2016, 11 high grade locally advanced ESTS patients underwent this treatment regimen. Preoperative EBRT (12 × 3 Gy) started <4 weeks following the HILP (TNF-α and melphalan) and the surgical resection was planned to take place <2 weeks following the end of the EBRT. RESULTS: All patients completed the treatment. After a median follow-up of 32 (23-50) months, the limb was saved in 10 patients (91%), 1 patient (9%) developed a local recurrence, 5 patients (45%) developed distant metastases, and 3 patients (27%) died of their disease. During follow-up two patients (18%) developed a pathologic fracture of the treated limb and three patients (27%) developed a major wound complication requiring surgical intervention. The median overall treatment time (OTT) was 56 (49-69) days. CONCLUSIONS: This intensive treatment regimen is feasible and safe in locally advanced ESTS, and it achieves oncological results that are comparable with conventional HILP treatment. In addition, the major wound complication risk is comparable and the OTT is reduced.


Assuntos
Quimioterapia do Câncer por Perfusão Regional , Procedimentos Cirúrgicos de Citorredução , Extremidades , Hipertermia Induzida , Recidiva Local de Neoplasia/terapia , Radioterapia , Sarcoma/terapia , Adulto , Idoso , Antineoplásicos Alquilantes/uso terapêutico , Terapia Combinada , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Melfalan/uso terapêutico , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/patologia , Cuidados Pré-Operatórios , Prognóstico , Terapia de Salvação , Sarcoma/patologia , Taxa de Sobrevida
12.
Clin Endocrinol (Oxf) ; 86(3): 419-424, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27588675

RESUMO

OBJECTIVE: Thyroglobulin (Tg) is an excellent tumour marker, as detectable or increasing Tg levels are highly indicative of persistent or recurrent differentiated thyroid carcinoma (DTC). The clinical value of a highly sensitive (hs)-Tg assay in patients with DTC has not yet been established. The aim of this study was to investigate the additional value of unstimulated hs-Tg measurements (Tg-on) compared to stimulated IRMA-Tg measurements (Tg-off) in the follow-up of patients with DTC. DESIGN, PATIENTS, MEASUREMENTS: We retrospectively studied patients treated for DTC between 2006 and 2013 and compared hs-Tg and IRMA-Tg measurements. The study group consisted of 99 DTC patients in remission; Tg-on was measured 3 months after remnant ablation and Tg-off 6 months after ablation. RESULTS: In the study group, 44 patients showed a hs-Tg-on <0·15 µg/l (functional sensitivity); of these, 43 had an IRMA-Tg-off measurement <1·0 µg/l, resulting in a negative predictive value of 97·7% and a positive predictive value of 56·4%. CONCLUSIONS: The hs-Tg-on measurement is able to predict patients with an IRMA-Tg-off <1·0 µg/l, and therefore decreases the need for Tg stimulation after ablation.


Assuntos
Tireoglobulina/sangue , Neoplasias da Glândula Tireoide/diagnóstico , Adulto , Biomarcadores Tumorais/sangue , Biomarcadores Tumorais/normas , Ablação por Cateter , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Valor Preditivo dos Testes , Indução de Remissão , Estudos Retrospectivos , Testes de Função Tireóidea/métodos , Testes de Função Tireóidea/normas
14.
Langenbecks Arch Surg ; 402(7): 1109-1117, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28091771

RESUMO

PURPOSE: Minimally invasive parathyroidectomy (MIP) is the recommended treatment in primary hyperparathyroidism (pHPT) for which accurate preoperative localization is essential. The current imaging standard consists of cervical ultrasonography (cUS) and MIBI-SPECT/CT. 11C-MET PET/CT has a higher resolution than MIBI-SPECT/CT. The aim of this study was to determine the diagnostic performance of 11C-MET PET/CT after initial inconclusive or negative localization. METHODS: We performed a retrospective single center cohort study of patients with pHPT undergoing parathyroid surgery after prior negative imaging and later localization by means of 11C-MET PET/CT between 2006 and 2014. Preoperative localization by 11C-MET PET/CT was compared with later surgical localization, intraoperative quick PTH (IOPTH), duration of surgery, histopathology, and follow-up data. Also, differences in duration of surgery between the groups with and without correct preoperative localization were analyzed. RESULTS: In 18/28 included patients a positive 11C-MET-PET/CT result corresponded to the surgical localized adenoma (64%). In 3/28 patients imaging was false positive and no adenoma was found. In 7/28 patients imaging was false negative at the side of the surgically identified adenoma. Sensitivity of 11C-MET PET/CT was 72% (18/25). Duration of surgery of correctly localized patients was significantly shorter compared to falsely negative localized patients (p = 0.045). CONCLUSION: In an intention to treat 11C-MET-PET/CT correctly localized the parathyroid adenoma in 18/28 (64%) patients, after previous negative imaging. A preoperatively correct localized adenoma leads to a more focused surgical approach (MIP) potentially reducing duration of surgery and potentially healthcare costs.


Assuntos
Adenoma/diagnóstico por imagem , Neoplasias das Paratireoides/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Adenoma/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Radioisótopos de Carbono , Feminino , Humanos , Masculino , Metionina , Pessoa de Meia-Idade , Neoplasias das Paratireoides/cirurgia , Paratireoidectomia , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
15.
Gastrointest Endosc ; 81(1): 159-167.e2, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25527055

RESUMO

BACKGROUND: In multiple endocrine neoplasia type 1 (MEN1), pancreatic neuroendocrine tumors (pNETs) are the leading MEN1-related cause of death. OBJECTIVE: To evaluate EUS and (11)C-5-hydroxytryptophan positron emission tomography ((11)C-5-HTP PET), compared with the recommended screening techniques in MEN1 patients for early detection of pNETs. DESIGN: Cross-sectional study. SETTING: Tertiary-care university medical center. PATIENTS: This study involved 41 patients with a proven MEN1 mutation or with one MEN1 manifestation and a mutation carrier as a first-degree family member, with recent screening by abdominal CT or magnetic resonance imaging (MRI) and somatostatin receptor scintigraphy (SRS). INTERVENTIONS: EUS by using a linear Pentax echoendoscope and Hitachi EUB-525 and (11)C-5-HTP PET. MAIN OUTCOME MEASUREMENTS: Patient-based and lesion-based positivity for pNET was calculated for all imaging techniques. The McNemar test was used to compare the yield of the 4 imaging techniques. RESULTS: In 35 of 41 patients, 107 pancreatic lesions were detected in total. EUS detected 101 pancreatic lesions in 34 patients, (11)C-5-HTP PET detected 35 lesions in 19 patients, and CT/MRI + SRS detected 32 lesions in 18 patients (P < .001). (11)C-5-HTP PET performed similarly to CT/MRI + SRS and better compared with SRS only (13 lesions in 12 patients), both at a patient-based and lesion-based level (P < .05). LIMITATIONS: Single-center study. CONCLUSION: EUS is superior to CT/MRI + SRS for pancreatic lesion detection in patients with MEN1. In this setting, (11)C-5-HTP PET is not useful. We recommend EUS as the first-choice pancreas imaging technique in patients with MEN1. ( CLINICAL TRIAL REGISTRATION NUMBER: NTR1668.).


Assuntos
Neoplasia Endócrina Múltipla Tipo 1/diagnóstico , Tumores Neuroendócrinos/diagnóstico , Pâncreas/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico , 5-Hidroxitriptofano , Adolescente , Adulto , Idoso , Radioisótopos de Carbono , Estudos Transversais , Detecção Precoce de Câncer , Endossonografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Neoplasia Endócrina Múltipla Tipo 1/complicações , Tumores Neuroendócrinos/etiologia , Neoplasias Pancreáticas/etiologia , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X , Adulto Jovem
16.
Mol Imaging ; 13(5)2014.
Artigo em Inglês | MEDLINE | ID: mdl-24825298

RESUMO

Human epidermal growth factor receptor (HER)2 imaging with radiolabeled trastuzumab might support HER2-targeted therapy. It is, however, frequently questioned whether HER2 imaging is also possible during trastuzumab treatment as the receptor might be saturated. We studied the effect of trastuzumab treatment on 111In-trastuzumab uptake. Patients received trastuzumab weekly and paclitaxel once every 3 weeks. 111In-trastuzumab was injected on day 1 of cycle 1 and day 15 of cycle 4. Whole-body planar scintigraphy was acquired at different time points postinjection. Tumor uptake and organ distribution between the first and repeated scan series were calculated via residence times. Twenty-five tumor lesions in 12 patients were visualized on both scintigraphy series. Tumor uptake decreased (19.6%; p  =  .03). The residence times of normal organs remained similar except for the cardiac blood pool (+ 16.3%; p  =  .014). Trastuzumab treatment decreases tumor 111In-trastuzumab uptake around 20%. HER2 imaging is feasible during trastuzumab treatment.


Assuntos
Anticorpos Monoclonais Humanizados/administração & dosagem , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Radioisótopos de Índio , Anticorpos Monoclonais Humanizados/química , Anticorpos Monoclonais Humanizados/farmacocinética , Anticorpos Monoclonais Humanizados/uso terapêutico , Antineoplásicos/administração & dosagem , Protocolos de Quimioterapia Combinada Antineoplásica , Esquema de Medicação , Feminino , Humanos , Metástase Neoplásica/diagnóstico por imagem , Metástase Neoplásica/tratamento farmacológico , Paclitaxel/administração & dosagem , Cintilografia , Receptor ErbB-2/metabolismo , Trastuzumab
17.
Med Phys ; 51(1): 139-155, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38047554

RESUMO

BACKGROUND: The use of computed tomography (CT) for attenuation correction (AC) in whole-body PET/CT can result in a significant contribution to radiation exposure. This can become a limiting factor for reducing considerably the overall radiation exposure of the patient when using the new long axial field of view (LAFOV) PET scanners. However, recent CT technology have introduced features such as the tin (Sn) filter, which can substantially reduce the CT radiation dose. PURPOSE: The purpose of this study was to investigate the ultra-low dose CT for attenuation correction using the Sn filter together with other dose reduction options such as tube current (mAs) reduction. We explore the impact of dose reduction in the context of AC-CT and how it affects PET image quality. METHODS: The study evaluated a range of ultra-low dose CT protocols using five physical phantoms that represented a broad collection of tissue electron densities. A long axial field of view (LAFOV) PET/CT scanner was used to scan all phantoms, applying various CT dose reduction parameters such as reducing tube current (mAs), increasing the pitch value, and applying the Sn filter. The effective dose resulting from the CT scans was determined using the CTDIVol reported by the scanner. Several voxel-based and volumes of interest (VOI)-based comparisons were performed to compare the ultra-low dose CT images, the generated attenuation maps, and corresponding PET images against those images acquired with the standard low dose CT protocol. Finally, two patient datasets were acquired using one of the suggested ultra-low dose CT settings. RESULTS: By incorporating the Sn filter and adjusting mAs to the lowest available value, the radiation dose in CT images of PBU-60 phantom was significantly reduced; resulting in an effective dose of nearly 2% compared to the routine low dose CT protocols currently in clinical use. The assessment of PET images using VOI and voxel-based comparisons indicated relative differences (RD%) of under 6% for mean activity concentration (AC) in the torso phantom and patient dataset and under 8% for a source point in the CIRS phantom. The maximum RD% value of AC was 14% for the point source in the CIRS phantom. Increasing the tube current from 6 mAs to 30 mAs in patients with high BMI, or with arms down, can suppress the photon starvation artifact, whilst still preserving a dose reduction of 90%. CONCLUSIONS: Introducing a Sn filter in CT imaging lowers radiation dose by more than 90%. This reduction has minimal effect on PET image quantification at least for patients without Body Mass Index (BMI) higher than 30. Notably, this study results need validation using a larger clinical PET/CT dataset in the future, including patients with higher BMI.


Assuntos
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Tomógrafos Computadorizados , Tomografia por Emissão de Pósitrons/métodos , Imagens de Fantasmas
18.
Clin Cancer Res ; 2024 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-39325013

RESUMO

Current immunotherapies have brought major progress in cancer treatments, but not all patients benefit. Therefore, insight into reasons for treatment failure and optimal biomarkers for patient selection are warranted. Current approved biomarkers for cancer immunotherapy do not provide insight into characteristics across tumor lesions in a patient or their heterogeneity. Here, whole-body positron emission tomography (PET) imaging with specific tracers may provide support. Moreover, the biodistribution of cell therapies and complex molecules, such as bispecific antibodies, can be visualized by PET imaging, and repeat PET imaging allows to study the whole-body kinetics of the immune response. In this review, we present the status of using PET imaging-derived biomarkers for patients with cancer receiving immunotherapy. Next, the hopes and scientific challenges ahead to optimize current PET imaging biomarker development and to discover novel PET-derived baseline and dynamic biomarkers to potentially guide us in drug development and more precise patient and therapy selection will be discussed.

19.
Ned Tijdschr Geneeskd ; 1682024 06 10.
Artigo em Holandês | MEDLINE | ID: mdl-38888394

RESUMO

The differential diagnosis of a rapidly enlarging neck mass consists of many different benign ((haemorrhagic) cyst) and malignant (anaplastic thyroid cancer (ATC) and lymphoma) causes. ATC is a rare disease with a median survival of 6 months. As early diagnosis and management are key for fast-growing cancers, in our centre we have implemented a dedicated short-stay in-hospital fast-track diagnostic work-up for patients with a rapid growing mass in the neck. The goal of this track is to have a fast diagnostic and therapeutic plan for this disease. Based on three clinical cases we discuss our experience with this fast-track diagnostic work-up for rapidly growing mass in the neck and illustrate the additional value in this clinical entity.


Assuntos
Neoplasias da Glândula Tireoide , Idoso , Humanos , Pessoa de Meia-Idade , Diagnóstico Diferencial , Neoplasias de Cabeça e Pescoço/diagnóstico , Neoplasias de Cabeça e Pescoço/patologia , Pescoço/patologia , Carcinoma Anaplásico da Tireoide/patologia , Carcinoma Anaplásico da Tireoide/diagnóstico , Neoplasias da Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/diagnóstico
20.
Semin Nucl Med ; 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39384519

RESUMO

[18F]-dihydroxyphenylalanine ([18F]FDOPA) is a radiopharmaceutical used in a broad spectrum of diseases, including neuroendocrine tumors (NETs), congenital hyperinsulinism, parkinsonian syndromes and neuro-oncology. Genetic analysis and disease specific biomarkers may guide the optimum selection of patients that may benefit most from [18F]FDOPA PET in different stages of several neuroendocrine neoplasms and in congenital hyperinsulinism. For clinical routine in neuro-oncology, indications for [18F]FDOPA PET include tumor delineation and distinguishing between treatment related changes and recurrent disease. New developments as the advent of large axial field of view PET/CT or integrated PET/MRI systems may provide more unique opportunities, such as those related to detection of smaller lesions in primary staging of NETs, dose reduction in children with congenital hyperinsulinism, or possibilities to obtain more extensive noninvasive quantification of cerebral uptake by using image derived input functions. Although the widespread use of [18F]FDOPA has been hampered by complex synthesis methods and high production costs in the past, significant efforts have been undertaken to provide robust GMP compliant synthesis methods with high activity yield and molar activity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA