Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Bioengineering (Basel) ; 9(12)2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36551026

RESUMO

The removal of filling material is important for successful root canal retreatment. The aim of the study was to compare the efficiency of two activated irrigation techniques, the shock wave-enhanced emission photoacoustic streaming (SWEEPS) mode of the Er:YAG laser and ultrasonically activated irrigation (UAI) and a conventional syringe-needle technique (SNI), in the removal of bioceramic sealer/gutta-percha during conventional retreatment in oval root canals. The study sample consisted of distal root canals of 42 extracted human mandibular molars, which were prepared using a ProTaper Next system up to size 40/0.06 and filled with bioceramic sealer using a single-cone obturation technique. The teeth were then re-treated with a Reciproc Blue RB40 file and 3% sodium hypochlorite solution. The prepared teeth were randomly divided into three groups (n = 14 per group) and subjected to one of the three irrigation methods. Micro-CT scans were performed at different stages to assess the amount of filling material after each retreatment phase. The results of the study showed that all the tested irrigation techniques reduced a statistically significant amount of the remnant filling material at retreatment (p < 0.05), and there were no statistically significant differences in efficacy between the three methods. All tested techniques had similar efficacy in the removal of the remaining filling remnants.

2.
Acta Stomatol Croat ; 55(2): 129-136, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34248146

RESUMO

OBJECTIVES: To determine the accuracy of visual damage evaluation of rotating and reciprocal endodontic instruments with the naked eye and optical devices. MATERIAL AND METHODS: Four examiners were involved, divided into two age groups: I. 20-30 years, n = 2, II. 40-50 years, n = 2. They visually assessed the existence of damage to rotating or reciprocal endodontic instruments by their naked eye and with two types of optical aids. A total of 239 instruments from different manufacturers were evaluated by each examiner. Before damage estimation, each examiner calibrated the eye on a new instrument. Sensitivity of the detection method was calculated as by the naked eye. When an instrument was detected as damaged by the naked eye, the damage assessment was stopped and the instrument was considered to be damaged by the other two methods, as well. RESULTS: Damage was found in 178 instruments. Sensitivity of the naked eye was calculated to be 49.7%, for the loupe 66.2% and for the operating microscope 76.5%. The three methods of damage assessment had significant differences (p < 0.05) in sensitivity. CONCLUSION: It was concluded that there is a significant difference between age groups in estimating instrument damage. Also, it was noted that the damage assessment with the naked eye and optical aids were different. Finally, in terms of ease of damage recognition, significant differences between the types of engine-driven endodontic instruments were found. However, no type of instrument was more prone to damage than any other type of instrument.

3.
Dent J (Basel) ; 9(2)2021 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-33670254

RESUMO

The aim of the study is to compare the frequency and the distribution of molar incisor hypomineralization (MIH) in children with intellectual disabilities. METHODS: Seventy-two children with intellectual disabilities and 72 healthy children were included in the study. They ranged in age from 5 to 18 years with the same distribution by age and sex. Standard clinical examination was performed, at a dental clinic or in the institution where the children lived, by using a dental mirror and a probe, according the European Academy of Paediatric Dentistry judgment criteria for MIH. RESULTS: Among the 72 children with intellectual disabilities, eight children (11.1%) presented MIH with 19 affected teeth. In the control group, one child (1.4%) presented MIH with two affected teeth. The difference was statistically significant (p = 0.033). There were no statistically significant differences between boys and girls. The molars, especially the first right molars were the most affected tooth. Brown defects were less common than white defects. CONCLUSION: Children with MIH should be identified because this condition is a common problem in children with intellectual disabilities.

4.
Acta Stomatol Croat ; 54(2): 168-174, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32801376

RESUMO

OBJECTIVE: The aim of this study was to evaluate the usage of caries risk assessment (CRA) by Croatian general practitioners and evaluate their knowledge and attitudes towards CRA. MATERIAL AND METHODS: A link to an online questionnaire was sent via e-mail to a sample of 1,500 general dentists in Croatia. The obtained data were analyzed using descriptive statistics, logistic regression analyses and chi-square tests. RESULTS: Of 257 respondents, 47% performed CRA routinely, but only 4.5% of them used a specific CRA form. The significance of different factors in the development of a treatment plan varied considerably among respondents. Furthermore, in 77% of the respondents CRA was a basis for planning individual caries prevention (ICP). The association between CRA and ICP, and between CRA and treatment planning was statistically significant (p=0.001). The practitioners doing CRA more often plan their treatment and ICP according to CRA. The use of CRA was not influenced by specialty and dentists' experience. CONCLUSIONS: In a considerable percentage (53%) of Croatian general dentists, CRA is not part of their routine practice, and there is a strong association between the use of CRA and treatment plans and ICP. There is a need to promote the use of CRA in daily dental practice in Croatia.

5.
Acta Stomatol Croat ; 53(2): 125-131, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31341320

RESUMO

OBJECTIVES: to determine the mechanical properties of hybrid and high-viscosity glass ionomer cements. Compressive strength and hardness of three glass ionomer cements (GIC) were measured: Ketac ™ Universal Aplicap ™, EQUIA Fil® and EQUIA FORTE Fil®, and the SEM sample analysis were performed. MATERIALS AND METHODS: The samples for measuring the compressive strength were prepared using silicone molds with standard dimensions of 6 mm x 4 mm and stored in deionized water for five days, while the samples for hardness measurement were prepared using Teflon molds with a cylindrical opening in the middle, dimensions 2 mm in height and 5 mm in width. For each material, one sample was made (n = 1) and stored in deionized water at 37ºC for 25 days. A representative sample of each material was analyzed using SEM. For the comparison of obtained values, the ANOVA test was used, while Tukey test was used for the multiple comparison. RESULTS: There were no significant differences between the compressive strength of the three tested materials (p <0.05). The hardness values were: 157 HV0,2 for Ketac ™ Universal Aplicap ™, 47 HV0,2 for EQUIA Fil® and 39 HV0,2 for EQUIA FORTE Fil®, respectively, and were significantly different, implying that Ketac ™ Universal Aplicap ™ has much higher hardness values than the other materials tested. SEM sample analysis revealed similar fracture modes of the tested materials. CONCLUSION: It was concluded that there were no statistically significant differences in compressive strength and fracture modes between the tested materials, while Ketac ™ Universal Aplicap ™ hardness results were significantly higher than the ones measured for EQUIA Fil® and EQUIA FORTE Fil®.

6.
Acta Stomatol Croat ; 53(4): 318-325, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32099257

RESUMO

OBJECTIVE: The objective of the study was to compare compressive strengths of two glass ionomer-based materials, with and without a light-cured, nano-filled coating, after cyclic loading and thermocycling. MATERIALS AND METHODS: To determine compressive strength of new restorative materials over a longer period of time, materials were analysed under simulated conditions where cyclic loading replicated masticatory loading and thermocycling simulated thermal oscillations in the oral cavity. Four groups of samples (n=7)-(1) Equia Fil (GC, Tokyo, Japan) uncoated; (2) Equia Fil coated with Equia Coat (GC, Tokyo, Japan); (3) Equia Forte Fil (GC, Tokyo, Japan) uncoated; and (4) Equia Forte Fil coated with Equia Forte coat (GC, Tokyo, Japan)-were subjected to cyclic loading (240,000 cycles) using a chewing simulator (MOD, Esetron Smart Robotechnologies, Ankara, Turkey). RESULTS: Compressive strength measurements were performed according to ISO 9917-1:2007, using the universal mechanical testing machine (Instron, Lloyd, UK). Scanning electron microscope (SEM) analysis was performed after thermocycling. There were no statistically significant differences between Equia Fil and Equia Forte Fil irrespective of the coating (p<0.05), but a trend of increasing compressive strength in the coated samples was observed. CONCLUSIONS: Coating increases the compressive strength of Equia Fil and Equia Forte Fil, but not significantly.

7.
Acta Clin Croat ; 57(2): 278-285, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30431720

RESUMO

The aim of this in vitro study was to evaluate cytotoxicity and genotoxicity of six different dental nanocomposite materials, three conventional ones and three flowable composite resin materials, in human lymphocytes. The following materials were tested: Tetric EvoCeram, Tetric EvoFlow, Filtek Ultimate, Filtek Ultimate Flow, G-aenial and G-aenial Flo. Cytotoxicity was evaluated for two mass concentrations (0.007 g/mL and 0.013 g/mL) of each material, non-cured and cured, after 4 hours and 24 hours. Genotoxicity was evaluated using micronucleus assay under the same conditions as applied during the investigation of cytotoxicity. Uncured forms of Tetric EvoCeram, Tetric EvoFlow and Filtek Ultimate Flow in higher mass concentration caused genotoxic effect. Uncured G-aenial Flo in higher mass concentration induced apoptosis and necrosis. Uncured Tetric EvoFlow and uncured Filtek Ultimate Flow in higher mass concentration induced early apoptosis after both test periods. None of the conventional composite resin materials tested showed cytotoxicity except for uncured G-aenial, which induced apoptosis in higher mass concentration in both test periods. In conclusion, under the conditions of this in vitro study, cured conventional composites did not show cytotoxic or genotoxic effect, which is important for clinical application of these materials, whereas uncured forms exhibited certain level of cytotoxicity and genotoxicity, mainly because of monomers in their composition.


Assuntos
Resinas Compostas , Materiais Dentários , Linfócitos , Resinas Compostas/toxicidade , Materiais Dentários/toxicidade , Humanos , Teste de Materiais
8.
Acta Stomatol Croat ; 52(4): 307-313, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30666061

RESUMO

OBJECTIVE: This in vitro study compares the fluoride release from microlaminated glass ionomer based on glass hybrid technology coated with two different surface coating agents. MATERIALS AND METHODS: A total of 18 samples were divided into three groups of six samples each: (1) glass ionomer Equia Forte Fil coated with Equia Forte Coat (Equia+EC), (2) glass ionomer Equia Forte Fil coated with GC Fuji Varnish (Equia+VC) and (3) uncoated glass ionomer Equia Forte (EQUIA cont). Fluoride release was measured using an ion-selective electrode (ORION EA 940) after 24 hours, 4 days, 30 days and 64 days. Repeated measures ANOVA, multiple comparisons, Tukey's test and paired t-test were used to test the differences between the groups. RESULTS: The differences between the groups and four time points were statistically significant (ANOVA, p<0.0001). Cumulative fluoride ion release after 64 days was 66.01 mg/l, 123.54mg/l and 203.22 mg/l for EQUIA+EC, EQUIA+VC and EQUIA cont, respectively. All the differences were statistically significant except the difference between EQUIA+VC and EQUIA cont after 24 hours. CONCLUSIONS: The amount of released fluoride was significantly lower in the samples coated with nanofilled surface coating agent compared to the samples coated with varnish and uncoated samples.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA