Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 94(16): 6191-6199, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35421308

RESUMO

Isomeric peptide analyses are an analytical challenge of great importance to therapeutic monoclonal antibody and other biotherapeutic product development workflows. Aspartic acid (Asp, D) to isoaspartic acid (isoAsp, isoD) isomerization is a critical quality attribute (CQA) that requires careful control, monitoring, and quantitation during the drug discovery and production processes. While the formation of isoAsp has been implicated in a variety of disease states such as autoimmune diseases and several types of cancer, it is also understood that the formation of isoAsp results in a structural change impacting efficacy, potency, and immunogenic properties, all of which are undesirable. Currently, lengthy ultrahigh-performance liquid chromatography (UPLC) separations are coupled with MS for CQA analyses; however, these measurements often take over an hour and drastically limit analysis throughput. In this manuscript, drift tube ion mobility spectrometry-mass spectrometry (DTIMS-MS) and both a standard and high-resolution demultiplexing approach were utilized to study eight isomeric Asp and isoAsp peptide pairs. While the limited resolving power associated with the standard DTIMS analysis only separated three of the eight pairs, the application of HRdm distinguished seven of the eight and was only unable to separate DL and isoDL. The rapid high-throughput HRdm DTIMS-MS method was also interfaced with both flow injection and an automated solid phase extraction system to present the first application of HRdm for isoAsp and Asp assessment and demonstrate screening capabilities for isomeric peptides in complex samples, resulting in a workflow highly suitable for biopharmaceutical research needs.


Assuntos
Espectrometria de Mobilidade Iônica , Ácido Isoaspártico , Cromatografia Líquida , Espectrometria de Mobilidade Iônica/métodos , Ácido Isoaspártico/análise , Espectrometria de Massas/métodos , Peptídeos
2.
Anal Bioanal Chem ; 414(1): 623-637, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34347113

RESUMO

Glycosylation is a ubiquitous co- and post-translational modification involved in the sorting, folding, and trafficking of proteins in biological systems; in humans, >50% of gene products are glycosylated with the cellular machinery of glycosylation compromising ~2% of the genome. Perturbations in glycosylation have been implicated in a variety of diseases including neurodegenerative diseases and certain types of cancer. However, understanding the relationship between a glycan and its biological role is often difficult due to the numerous glycan isomers that exist. To address this challenge, nanoflow liquid chromatography, ion mobility spectrometry, and mass spectrometry (nLC-IMS-MS) were combined with the Individuality Normalization when Labeling with the Isotopic Glycan Hydrazide Tags (INLIGHT™) strategy to study a series of glycan standards and those enzymatically released from the glycoproteins horseradish peroxidase, fetuin, and pooled human plasma. The combination of IMS and the natural (NAT) and stable-isotope label (SIL) in the INLIGHT™ strategy provided additional confidence for each glycan identification due to the mobility aligned NAT- and SIL-labeled glycans and further capabilities for isomer examinations. Additionally, molecular trend lines based on the IMS and MS dimensions were investigated for the INLIGHT™ derivatized glycans, facilitating rapid identification of putative glycans in complex biological samples.


Assuntos
Espectrometria de Mobilidade Iônica , Polissacarídeos , Cromatografia Líquida , Glicômica/métodos , Glicosilação , Humanos , Espectrometria de Massas/métodos , Polissacarídeos/análise
3.
Anal Bioanal Chem ; 412(27): 7569-7579, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32844281

RESUMO

The analysis of N-linked glycans using liquid chromatography and mass spectrometry (LC-MS) presents significant challenges, particularly owing to their hydrophilic nature. To address these difficulties, a variety of derivatization methods have been developed to facilitate improved ionization and detection sensitivity. One such method, the Individuality Normalization when Labeling with Isotopic Glycan Hydrazide Tags (INLIGHT)™ strategy for labeling glycans, has previously been utilized in the analysis of N- and O-linked glycans in biological samples. To assess the maximum sensitivity and separability of the INLIGHT™ preparation and analysis pipeline, several critical steps were investigated. First, recombinant and nonrecombinant sources of PNGase F were compared to assess variations in the released glycans. Second, modifications in the INLIGHT™ derivatization step were evaluated including temperature optimization, solvent composition changes, reaction condition length and tag concentration. Optimization of the modified method resulted in 20-100 times greater peak areas for the detected N-linked glycans in fetuin and horseradish peroxidase compared with the standard method. Furthermore, the identification of low-abundance glycans, such as (Fuc)1(Gal)2(GlcNAc)4(Man)3(NeuAc)1 and (Gal)3(GlcNAc)5(Man)3(NeuAc)3, was possible. Finally, the optimal LC setup for the INLIGHT™ derivatized N-linked glycan analyses was found to be a C18 reverse-phase (RP) column with mobile phases typical of RPLC.


Assuntos
Glicômica/métodos , Polissacarídeos/análise , Cromatografia de Fase Reversa/métodos , Feminino , Fetuínas/química , Glicosilação , Humanos , Masculino , Peptídeo-N4-(N-acetil-beta-glucosaminil) Asparagina Amidase/química , Espectrometria de Massas em Tandem/métodos
4.
J Am Soc Mass Spectrom ; 33(10): 1904-1913, 2022 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-36136315

RESUMO

In 2017, the United States Department of Health and Human Services declared the widespread misuse and abuse of prescription and illicit opioids an epidemic. However, this epidemic dates back to the 1990s when opioids were extensively prescribed for pain management. Currently, opioids are still recommended for pain management, and given their abuse potential, rapid screening is imperative for patient treatment. Of particular importance is assessing pain management patient compliance, where evaluating drug use is crucial for preventing opioid abuse and potential overdoses. In this work, we utilized drift tube ion mobility spectrometry coupled with mass spectrometry (DTIMS-MS) to develop a rapid screening method for 33 target opioids and opioid urinary metabolites. Collision cross section values were determined for all target molecules using a flow-injection DTIMS-MS method, and clear differentiation of 27 out of the 33 opioids without prior chromatographic separation was observed when utilizing a high resolution demultiplexing screening approach. An automated solid phase extraction (SPE) platform was then coupled to DTIMS-MS for 10 s sample-to-sample analyses. This SPE-IMS-MS approach enabled the rapid screening of urine samples for opioids and presents a major improvement in sample throughput compared to traditional chromatographic analyses coupled with MS, which routinely take several minutes per sample. Overall, this vast reduction in analysis time facilitates a faster turn-around for patient samples, providing great benefits to clinical applications.


Assuntos
Analgésicos Opioides , Espectrometria de Mobilidade Iônica , Ensaios de Triagem em Larga Escala , Humanos , Espectrometria de Mobilidade Iônica/métodos , Espectrometria de Massas/métodos , Extração em Fase Sólida
5.
Front Chem ; 9: 614595, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33634076

RESUMO

Native mass spectrometry has emerged as a powerful tool for structural biology as it enables the evaluation of molecules as they occur in their physiological conditions. Ion mobility spectrometry-mass spectrometry (IMS-MS) has shown essential in these analyses as it allows the measurement of the shape of a molecule, denoted as its collision cross section (CCS), and mass. The structural information garnered from native IMS-MS provides insight into the tertiary and quaternary structure of proteins and can be used to validate NMR or crystallographic X-ray structures. Additionally, due to the rapid nature (millisecond measurements) and ability of IMS-MS to analyze heterogeneous solutions, it can be used to address structural questions not possible with traditional structural approaches. Herein, we applied multiple solution conditions to systematically denature bovine Cu/Zn-superoxide dismutase (SOD1) and assess its unfolding pathway from the holo-dimer to the holo-monomer, single-metal monomer, and apo-monomer. Additionally, we compared and noted 1-2% agreement between CCS values from both drift tube IMS and trapped IMS for the SOD1 holo-monomer and holo-dimer. The observed CCS values were in excellent agreement with computational CCS values predicted from the homo-dimer crystal structure, showcasing the ability to use both IMS-MS platforms to provide valuable structural information for molecular modeling of protein interactions and structural assessments.

6.
J Anal Toxicol ; 42(8): 537-543, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30371842

RESUMO

Electronic cigarettes (e-cigs) deliver nicotine in an aerosol to the user that simulates the smoke of traditional cigarettes purportedly without the pathology of inhaling tobacco smoke due to the absence of combustion. Advanced versions of e-cigs enable the user to potentially moderate the concentration of drug in the aerosol by selecting from a range of voltages on the power supply. A method was developed to trap the aerosol produced by a KangerTech AeroTank, 1.8 Ω preassembled atomizer in order to analyze the concentration of nicotine and to evaluate the constituents of the aerosol at various voltages on the power supply. A 12-mg/mL formulation of nicotine in 50:50 propylene glycol (PG):vegetable glycerin (VG) was used to produce aerosol at 3.9, 4.3 and 4.7 V. The aerosol was trapped in a simple glass assemblage and analyzed by a 3200 Q Trap HPLC-MS-MS. The dose of nicotine delivered in the aerosol at 3.9, 4.3 and 4.7 V was determined to be 88 ± 12 µg, 91 ± 15 µg and 125 ± 22 µg. The average recovery of nicotine in the trap across the voltages was 99.8%. The glass trap system was an effective device for collecting the aerosol for analysis and an increase in drug yield was observed with increasing voltage from the power supply on the e-cig. The glass trap system was also used in combination with a 100-µm solid-phase microextraction fiber to capture the aerosol and analyze it via DART-MS and GC-MS. Four commercial e-liquids labeled to contain nicotine were aerosolized at 4.3 V. The pharmacologically active ingredient, nicotine, as well as PG, VG and a number of flavoring agents found in these formulations were identified.


Assuntos
Aerossóis/química , Sistemas Eletrônicos de Liberação de Nicotina/normas , Nicotina/análise , Cromatografia Gasosa-Espectrometria de Massas , Microextração em Fase Sólida
7.
Front Pharmacol ; 7: 279, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27621706

RESUMO

Since 24 states and the District of Columbia have legalized marijuana in some form, suppliers of legal marijuana have developed Cannabis sativa products for use in electronic cigarettes (e-cigarettes). Personal battery powered vaporizers, or e-cigarettes, were developed to deliver a nicotine vapor such that smokers could simulate smoking tobacco without the inherent pathology of inhaled tobacco smoke. The liquid formulations used in these devices are comprised of an active ingredient such as nicotine mixed with vegetable glycerin (VG) and/or propylene glycol (PG) and flavorings. A significant active ingredient of C. sativa, cannabidiol (CBD), has been purported to have anti-convulsant, anti-nociceptive, and anti-psychotic properties. These properties have potential medical therapies such as intervention of addictive behaviors, treatments for epilepsy, management of pain for cancer patients, and treatments for schizophrenia. However, CBD extracted from C. sativa remains a DEA Schedule I drug since it has not been approved by the FDA for medical purposes. Two commercially available e-cigarette liquid formulations reported to contain 3.3 mg/mL of CBD as the active ingredient were evaluated. These products are not regulated by the FDA in manufacturing or in labeling of the products and were found to contain 6.5 and 7.6 mg/mL of CBD in VG and PG with a variety of flavoring agents. Presently, while labeled as to content, the quality control of manufacturers and the relative safety of these products is uncertain.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA