Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Appl Opt ; 53(24): 5425-33, 2014 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-25321115

RESUMO

The far-infrared spectroscopy of the troposphere (FIRST) instrument is a Fourier-transform spectrometer developed to measure the Earth's thermal emission spectrum with a particular emphasis on the far-infrared. FIRST has observed the atmosphere from both the ground looking up and from a high-altitude balloon looking down. A recent absolute laboratory calibration of FIRST under ground-like operating conditions showed accuracy to better than 0.3 K at near-ambient temperatures (270-325 K) but reduced accuracy at lower temperatures. This paper presents calibration results for balloon-flight conditions using a cold blackbody to simulate the space view used for on-board calibration. An unusual detector nonlinearity was discovered and corrected, and stray light was measured and removed. Over most of the range of Earth scene temperatures (205-300 K), the accuracy of FIRST is 0.35-0.15 K (one sigma).

2.
Appl Opt ; 52(2): 264-73, 2013 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-23314644

RESUMO

The far-infrared spectroscopy of the troposphere (FIRST) instrument is a Fourier transform spectrometer developed to measure the Earth's thermal emission spectrum with a particular emphasis on far-infrared (far-IR) wavelengths greater than 15 µm. FIRST was developed under NASA's Instrument Incubator Program to demonstrate technology for providing measurements from 10 to 100 µm (1000 to 100 cm(-1)) on a single focal plane with a spectral resolution finer than 1 cm(-1). Presently no spectrometers in orbit are capable of directly observing the Earth's far-IR spectrum. This fact, coupled with the fundamental importance of the far-IR to Earth's climate system, provided the impetus for the development of FIRST. In this paper the FIRST instrument is described and results of a detailed absolute laboratory calibration are presented. Specific channels in FIRST are shown to be accurate in the far-IR to better than 0.3 K at 270 K scene temperature, 0.5 K at 247 K, and 1 K at 225 K.

3.
Appl Opt ; 47(33): 6277-84, 2008 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-19023394

RESUMO

The Fourier Transform Ultraviolet Spectrometer (FTUVS) instrument has recorded a long-term data record of the atmospheric column abundance of the hydroxyl radical (OH) using the technique of high resolution solar absorption spectroscopy. We report new efforts in improving the precision of the OH measurements in order to better model the diurnal, seasonal, and interannual variability of odd hydrogen (HO(x)) chemistry in the stratosphere, which, in turn, will improve our understanding of ozone chemistry and its long-term changes. Until the present, the retrieval method has used a single strong OH absorption line P(1)(1) in the near-ultraviolet at 32,341 cm(-1). We describe a new method that uses an average based on spectral fits to multiple lines weighted by line strength and fitting precision. We have also made a number of improvements in the ability to fit a model to the spectral feature, which substantially reduces the scatter in the measurements of OH abundances.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA