Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Neuroimage ; 233: 117950, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33716159

RESUMO

In present study we aimed to validate the use of image-derived input functions (IDIF) in the kinetic modeling of cerebral blood flow (CBF) measured by [15O]H2O PET by comparing with the accepted reference standard arterial input function (AIF). Additional comparisons were made to mean cohort AIF and CBF values acquired by methodologically independent phase-contrast mapping (PCM) MRI. Using hybrid PET/MRI an IDIF was generated by measuring the radiotracer concentration in the internal carotid arteries and correcting for partial volume effects using the intravascular volume measured from MRI-angiograms. Seven patients with carotid steno-occlusive disease and twelve healthy controls were examined at rest, after administration of acetazolamide, and, in the control group, during hyperventilation. Agreement between the techniques was examined by linear regression and Bland-Altman analysis. Global CBF values modeled using IDIF correlated with values from AIF across perfusion states in both patients (p<10-6, R2=0.82, 95% limits of agreement (LoA)=[-11.3-9.9] ml/100 g/min) and controls (p<10-6, R2=0.87, 95% LoA=[-17.1-13.7] ml/100 g/min). The reproducibility of gCBF using IDIF was identical to AIF (15.8%). Values from IDIF and AIF had equally good correlation to measurements by PCM MRI, R2=0.86 and R2=0.84, (p<10-6), respectively. Mean cohort AIF performed substantially worse than individual IDIFs (p<10-6, R2=0.63, LoA=[-12.8-25.3] ml/100 g/min). In the patient group, use of IDIF provided similar reactivity maps compared to AIF. In conclusion, global CBF values modeled using IDIF correlated with values modeled by AIF and similar perfusion deficits could be established in a patient group.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Processamento de Imagem Assistida por Computador/normas , Imageamento por Ressonância Magnética/normas , Modelos Neurológicos , Tomografia por Emissão de Pósitrons/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Encéfalo/irrigação sanguínea , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/metabolismo , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Radioisótopos de Oxigênio/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , Água/metabolismo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA