Anal Bioanal Chem ; 416(9): 2335-2358, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38236394

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health, Office of Dietary Supplements (NIH ODS), introduced the first Standard Reference Material® (SRM) for determining vitamin D metabolites in 2009 motivated by significant concerns about the comparability and accuracy of different assays to assess vitamin D status. After 14 years, a suite of five serum matrix SRMs and three calibration solution SRMs are available. Values were also assigned for vitamin D metabolites in five additional SRMs intended primarily to support measurements of other clinical diagnostic markers. Both the SRMs and the certification approach have evolved from significant exogenous serum content to primarily endogenous content and from value assignment by combining the results of multiple analytical methods to the use of measurements exclusively from reference measurement procedures (RMPs). The impact of the availability of these SRMs can be assessed by both the distribution information (sales) and by reports in the scientific literature describing their use for method validation, quality control, and research. In this review, we describe the development of these SRMs, the evolution in design and value assignment, the expansion of information reported, and SRM use in validating analytical methods and providing quality assurance within the vitamin D measurement community.


Assuntos
Vitamina D , Vitaminas , Controle de Qualidade , Padrões de Referência , Suplementos Nutricionais/análise
2.
Clin Chem ; 69(11): 1227-1237, 2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37725906

RESUMO

It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.


Assuntos
Serviços de Laboratório Clínico , Ensaio de Proficiência Laboratorial , Humanos , Padrões de Referência , Kit de Reagentes para Diagnóstico
3.
Clin Chem ; 69(9): 966-975, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37566391

RESUMO

A secondary higher-order calibrator is required to be commutable with clinical samples to be suitable for use in the calibration hierarchy of an end-user clinical laboratory in vitro diagnostic medical device (IVD-MD). Commutability is a property of a reference material that means results for a reference material and for clinical samples have the same numeric relationship, within specified limits, across the measurement procedures for which the reference material is intended to be used. Procedures for assessing commutability have been described in the literature. This report provides recommendations for establishing a quantitative criterion to assess the commutability of a certified reference material (CRM). The criterion is the maximum allowable noncommutability bias (MANCB) that allows a CRM to be used as a calibrator in a calibration hierarchy for an IVD-MD without exceeding the maximum allowable combined standard uncertainty for a clinical sample result (umaxCS). Consequently, the MANCB is derived as a fraction of the umaxCS for the measurand. The suitability of an MANCB for practical use in a commutability assessment is determined by estimating the number of measurements of clinical samples and CRMs required based on the precision performance and nonselectivity for the measurand of the measurement procedures in the assessment. Guidance is also provided for evaluating indeterminate commutability conclusions and how to report results of a commutability assessment.

4.
Anal Bioanal Chem ; 415(5): 809-821, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36507958

RESUMO

The US National Institute of Standards and Technology (NIST) developed a Standard Reference Material® (SRM®) 3949 Folate Vitamers in Frozen Human Serum to replace SRM 1955 Homocysteine and Folate in Human Serum. The presence of increased endogenous levels of folic acid and 5-methyltetrahydrofolate (5mTHF) in SRM 3949, enhanced folate stability via addition of ascorbic acid, and inclusion of values for additional minor folates are improvements over SRM 1955 that should better serve the clinical folate measurement community. The new SRM contains folates at three levels. To produce SRM 3949, pilot sera were collected from 15 individual donors, 5 of whom were given a 400-µg folic acid supplement 1 h prior to blood draw to increase serum levels of 5mTHF and folic acid for the high-level material. To stabilize the folates, 0.5% (mass concentration) ascorbic acid was added as soon as possible after preparation of serum. These pilot sera were screened for five folates plus the pyrazino-s-triazine derivative of 4-α-hydroxy-5-methyltetrahydrofolate (MeFox) at the US Centers for Disease Control and Prevention (CDC) by isotope dilution liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS). Based on these results, a blending protocol was specified to obtain the three desired folate concentrations for SRM 3949. ID-LC-MS/MS analysis at the CDC and NIST was utilized to assign values for folic acid and 5mTHF, as well as several minor folates.


Assuntos
Ácido Fólico , Espectrometria de Massas em Tandem , Humanos , Ácido Fólico/análise , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Padrões de Referência , Ácido Ascórbico
5.
Anal Bioanal Chem ; 414(1): 333-349, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34432104

RESUMO

An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of liquid chromatography - tandem mass spectrometry (LC-MS/MS) assays used for the determination of serum total 25-hydroxyvitamin D (25(OH)D), which is the sum of 25-hydroxyvitamin D2 (25(OH)D2) and 25-hydroxyvitamin D3 (25(OH)D3). A set of 50 single-donor samples was assigned target values for concentrations of 25(OH)D2, 25(OH)D3, 3-epi-25-hydroxyvitamin D3 (3-epi-25(OH)D3), and 24R,25-dihydroxyvitamin D3 (24R,25(OH)2D3) using isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 1 includes results from 14 laboratories using 14 custom LC-MS/MS assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 53% of the LC-MS/MS assays met the VDSP criterion of mean % bias ≤ |±5%|. For the LC-MS/MS assays not meeting the ≤ |±5%| criterion, four assays had mean % bias of between 12 and 21%. Based on multivariable regression analysis using the concentrations of the four individual vitamin D metabolites in the 50 single-donor samples, the performance of several LC-MS/MS assays was found to be influenced by the presence of 3-epi-25(OH)D3. The results of this interlaboratory study represent the most comprehensive comparison of LC-MS/MS assay performance for serum total 25(OH)D and document the significant impact of the lack of separation of 3-epi-25(OH)D3 and 25(OH)D3 on assay performance, particularly with regard to mean % bias.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 25-Hidroxivitamina D 2 , Cromatografia Líquida/métodos , Padrões de Referência , Espectrometria de Massas em Tandem/métodos , Vitamina D/análogos & derivados
6.
Anal Bioanal Chem ; 414(1): 351-366, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34435207

RESUMO

An interlaboratory comparison study was conducted by the Vitamin D Standardization Program (VDSP) to assess the performance of ligand binding assays (Part 2) for the determination of serum total 25-hydroxyvitamin D [25(OH)D]. Fifty single-donor samples were assigned target values for concentrations of 25-hydroxyvitamin D2 [25(OH)D2], 25-hydroxyvitamin D3 [25(OH)D3], 3-epi-25-hydroxyvitamin D3 [3-epi-25(OH)D3], and 24R,25-dihydroxyvitamin D3 [24R,25(OH)2D3] using isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS). VDSP Intercomparison Study 2 Part 2 includes results from 17 laboratories using 32 ligand binding assays. Assay performance was evaluated using mean % bias compared to the assigned target values and using linear regression analysis of the test assay mean results and the target values. Only 50% of the ligand binding assays achieved the VDSP criterion of mean % bias ≤ |± 5%|. For the 13 unique ligand binding assays evaluated in this study, only 4 assays were consistently within ± 5% mean bias and 4 assays were consistently outside ± 5% mean bias regardless of the laboratory performing the assay. Based on multivariable regression analysis using the concentrations of individual vitamin D metabolites in the 50 single-donor samples, most assays underestimate 25(OH)D2 and several assays (Abbott, bioMérieux, DiaSorin, IDS-EIA, and IDS-iSYS) may have cross-reactivity from 24R,25(OH)2D3. The results of this interlaboratory study represent the most comprehensive comparison of 25(OH)D ligand binding assays published to date and is the only study to assess the impact of 24R,25(OH)2D3 content using results from a reference measurement procedure.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , 25-Hidroxivitamina D 2 , Cromatografia Líquida , Ligantes , Padrões de Referência , Vitamina D/análogos & derivados
7.
Anal Bioanal Chem ; 414(2): 1015-1028, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34750644

RESUMO

The Vitamin D External Quality Assessment Scheme (DEQAS) distributes human serum samples four times per year to over 1000 participants worldwide for the determination of total serum 25-hydroxyvitamin D [25(OH)D)]. These samples are stored at -40 °C prior to distribution and the participants are instructed to store the samples frozen at -20 °C or lower after receipt; however, the samples are shipped to participants at ambient conditions (i.e., no temperature control). To address the question of whether shipment at ambient conditions is sufficient for reliable performance of various 25(OH)D assays, the equivalence of DEQAS human serum samples shipped under frozen and ambient conditions was assessed. As part of a Vitamin D Standardization Program (VDSP) commutability study, two sets of the same nine DEQAS samples were shipped to participants at ambient temperature and frozen on dry ice. Twenty-eight laboratories participated in this study and provided 34 sets of results for the measurement of 25(OH)D using 20 ligand binding assays and 14 liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods. Equivalence of the assay response for the frozen versus ambient DEQAS samples for each assay was evaluated using multi-level modeling, paired t-tests including a false discovery rate (FDR) approach, and ordinary least squares linear regression analysis of frozen versus ambient results. Using the paired t-test and confirmed by FDR testing, differences in the results for the ambient and frozen samples were found to be statistically significant at p < 0.05 for four assays (DiaSorin, DIAsource, Siemens, and SNIBE prototype). For all 14 LC-MS/MS assays, the differences in the results for the ambient- and frozen-shipped samples were not found to be significant at p < 0.05 indicating that these analytes were stable during shipment at ambient conditions. Even though assay results have been shown to vary considerably among different 25(OH)D assays in other studies, the results of this study also indicate that sample handling/transport conditions may influence 25(OH)D assay response for several assays.


Assuntos
Congelamento , Vitamina D/análogos & derivados , Vitamina D/sangue , Cromatografia Líquida/métodos , Humanos , Espectrometria de Massas em Tandem/métodos
8.
Clin Chem ; 67(12): 1590-1605, 2021 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-34633037

RESUMO

BACKGROUND: The JCTLM created a Task Force on Reference Measurement System Implementation (TF-RMSI) to provide guidance on metrological traceability implementation for the in vitro diagnostics (IVD) community. CONTENT: TF-RMSI investigated the reference measurement systems (RMS) for 13 common measurands by applying the following procedural steps: (a) extracting data from the JCTLM database of available certified reference materials (CRMs) and reference measurement procedures (RMPs); (b) describing the RMS to which each recruited CRM or RMP belongs; (c) identifying the intended use of the CRMs, and, if used as a common calibrator for IVD measuring systems and/or trueness assessment of field methods was included, checking the CRM's certificate for information about commutability with clinical samples; and (d) checking if the CRM or RMP measurement uncertainty (MU) has the potential to be small enough to avoid significantly affecting the analytical performance specifications (APS) for MU of clinical sample results when the MU from the IVD calibrator and from the end-user measuring system were combined. SUMMARY: We produced a synopsis of JCTLM-listed higher-order CRMs and RMPs for the selected measurands, including their main characteristics for implementing traceability and fulfilling (or not) the APS for suitable MU. Results showed that traceability to higher-order references can be established by IVD manufacturers within the defined APS for most of the 13 selected measurands. However, some measurands do not yet have suitable CRMs for use as common calibrators. For these measurands, splitting clinical samples with a laboratory performing the RMP may provide a practical alternative for establishing a calibration hierarchy.


Assuntos
Laboratórios , Calibragem , Bases de Dados Factuais , Humanos , Padrões de Referência , Incerteza
9.
Anal Bioanal Chem ; 413(20): 5067-5084, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34184102

RESUMO

An interlaboratory study was conducted through the Vitamin D Standardization Program (VDSP) to assess commutability of Standard Reference Materials® (SRMs) and proficiency testing/external quality assessment (PT/EQA) samples for determination of serum total 25-hydroxyvitamin D [25(OH)D] using ligand binding assays and liquid chromatography-tandem mass spectrometry (LC-MS/MS). A set of 50 single-donor serum samples were assigned target values for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3] using reference measurement procedures (RMPs). SRM and PT/EQA samples evaluated included SRM 972a (four levels), SRM 2973, six College of American Pathologists (CAP) Accuracy-Based Vitamin D (ABVD) samples, and nine Vitamin D External Quality Assessment Scheme (DEQAS) samples. Results were received from 28 different laboratories using 20 ligand binding assays and 14 LC-MS/MS methods. Using the test assay results for total serum 25(OH)D (i.e., the sum of 25(OH)D2 and 25(OH)D3) determined for the single-donor samples and the RMP target values, the linear regression and 95% prediction intervals (PIs) were calculated. Using a subset of 42 samples that had concentrations of 25(OH)D2 below 30 nmol/L, one or more of the SRM and PT/EQA samples with high concentrations of 25(OH)D2 were deemed non-commutable using 5 of 11 unique ligand binding assays. SRM 972a (level 4), which has high exogenous concentration of 3-epi-25(OH)D3, was deemed non-commutable for 50% of the LC-MS/MS assays.


Assuntos
Sociedades Médicas/normas , Vitamina D/análogos & derivados , Vitamina D/química , Humanos , Padrões de Referência , Manejo de Espécimes , Vitamina D/sangue
10.
Clin Chem ; 66(6): 769-778, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32335671

RESUMO

Establishing metrological traceability to an assigned value of a matrix-based certified reference material (CRM) that has been validated to be commutable among available end-user measurement procedures (MPs) is central to producing equivalent results for the measurand in clinical samples (CSs) irrespective of the clinical laboratory MPs used. When a CRM is not commutable with CSs, the bias due to noncommutability will be propagated to the CS results causing incorrect metrological traceability to the CRM and nonequivalent CS results among different MPs. In a commutability assessment, a conclusion that a CRM is commutable or noncommutable for use with a specific MP is made when the difference in bias between the CRM and CSs meets or does not meet a criterion for that specific MP when compared to other MPs. A conclusion regarding commutability or noncommutability requires that the magnitude of the difference in bias observed in the commutability assessment remains unchanged over time. This conclusion requires the CRM to be stable and no substantive changes in the MPs. These conditions should be periodically reverified. If an available CRM is determined to be noncommutable for a specific MP, that CRM can be used in the calibration hierarchy for that MP when an appropriately validated MP-specific correction for the noncommutability bias is included. We describe with examples how a MP-specific correction and its uncertainty can be developed and applied in a calibration hierarchy to achieve metrological traceability of results for CSs to the CRM's assigned value.


Assuntos
Viés , Guias como Assunto , Kit de Reagentes para Diagnóstico/normas , Calibragem , Humanos , Padrões de Referência
11.
Clin Chem Lab Med ; 58(3): 368-374, 2020 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-31665109

RESUMO

Manufacturers of in vitro diagnostic medical devices, clinical laboratories, research laboratories and calibration laboratories require commutable reference materials that can be used in the calibration hierarchies of medical laboratory measurement procedures used for human specimens to establish metrological traceability to higher order reference systems. Commutable materials are also useful in external quality assessment surveys. In order to achieve these goals, matrix-based reference materials with long-term stability, appropriate measurand concentrations and commutability with individual human specimens are required. The Clinical and Laboratory Standards Institute (CLSI) guideline C37-A (now archived) provided guidance to prepare commutable pooled serum reference materials for use in the calibration hierarchies of cholesterol measurement procedures. Experience using the C37-A guideline has identified a number of technical enhancements as well as applications to measurands other than cholesterol. This experience is incorporated into this updated protocol to ensure the procedure will continue to meet the needs of the medical laboratory. The updated protocol describes a procedure for preparing frozen human serum units or pools with minimal matrix alterations that are likely to be commutable with individual human serum samples. The protocol provides step-by-step guidance for the planning phase, collection of individual serum units, processing the units, qualifying the units for use in a pool and frozen storage of aliquots of pooled sera to manufacture frozen serum pools. Guidance on how to perform quality control of the final product and suggestions on documentation are also provided.


Assuntos
Análise Química do Sangue/normas , Coleta de Amostras Sanguíneas/métodos , Documentação , Soro/química , Humanos , Valores de Referência
12.
Anal Bioanal Chem ; 411(28): 7341-7355, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31667564

RESUMO

Over two decades, the Organic Analysis Working Group (OAWG) of the Consultative Committee for Amount of Substance: Metrology in Chemistry and Biology (CCQM) has organized a number of comparisons for clinically relevant small molecule organic biomarkers. The aim of the OAWG community is to be part of the coordinated international movement towards accuracy and comparability of clinical measurements that will, in turn, minimize the wastage of repeat testing and unnecessary therapy to create a sustainable healthcare industry. International and regional directives/requirements on metrological traceability of calibrators and control materials are in place. Metrology institutes worldwide maintain infrastructure for the practical realization of metrological traceability and demonstrate the equivalence of their measurement capabilities through participation in key comparisons organized under the auspices of the CCQM. These institutes provide certified reference materials, as well as other dedicated value-assignment services benefiting the in-vitro diagnostic (IVD) industry, reference (calibration) laboratories and the clinical chemistry laboratories. The roles of these services in supporting national, regional, and international activities to ensure the metrological traceability of clinical chemistry measurements are described. Graphical abstract.


Assuntos
Biomarcadores/análise , Compostos Orgânicos/análise , Bibliotecas de Moléculas Pequenas/análise , Calibragem , Testes de Química Clínica , Humanos , Técnicas In Vitro , Padrões de Referência , Reprodutibilidade dos Testes
13.
Clin Chem ; 64(3): 447-454, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29348163

RESUMO

Commutability is a property of a reference material (RM) that relates to the closeness of agreement between results for an RM and results for clinical samples (CSs) when measured by ≥2 measurement procedures (MPs). Commutability of RMs used in a calibration traceability scheme is an essential property for them to be fit for purpose. Similarly, commutability of trueness controls or external quality assessment samples is essential when those materials are used to assess trueness of results for CSs. This report is part 1 of a 3-part series describing how to assess commutability of RMs. Part 1 defines commutability and addresses critical components of the experimental design for commutability assessment, including selection of individual CSs, use of pooled CSs, qualification of MPs for inclusion, establishing criteria for the determination that an RM is commutable, generalization of commutability conclusions to future measurements made with the MPs included in the assessment, and information regarding commutability to be included in the certificate for an RM. Parts 2 and 3 in the series present 2 different statistical approaches to commutability assessment that use fixed criteria related to the medical decisions that will be made using the laboratory test results.


Assuntos
Técnicas de Laboratório Clínico/normas , Calibragem , Humanos , Padrões de Referência
14.
Clin Chem ; 64(3): 465-474, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29348164

RESUMO

A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator based on its ability to fulfill its intended use in a calibration traceability scheme to produce equivalent clinical sample (CS) results among different measurement procedures (MPs) for the same measurand. Three sources of systematic error are elucidated in the context of creating the calibration model for translating MP signals to measurand amounts: calibration fit, calibrator level trueness, and commutability. An example set of 40 CS results from 7 MPs is used to illustrate estimation of bias and variability for each MP. The candidate RM is then used to recalibrate each MP, and its effectiveness in reducing the systematic error among the MPs within an acceptable level of equivalence based on medical requirements confirms its commutability for those MPs. The RM is declared noncommutable for MPs for which, after recalibration, the CS results do not agree with those from other MPs. When a lack of agreement is found, other potential causes, including lack of calibration fit, should be investigated before concluding the RM is noncommutable. The RM is considered fit for purpose for those MPs where commutability is demonstrated.


Assuntos
Técnicas de Laboratório Clínico/normas , Padrões de Referência , Viés , Calibragem , Humanos
15.
Clin Chem ; 64(3): 455-464, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29348165

RESUMO

A process is described to assess the commutability of a reference material (RM) intended for use as a calibrator, trueness control, or external quality assessment sample based on the difference in bias between an RM and clinical samples (CSs) measured using 2 different measurement procedures (MPs). This difference in bias is compared with a criterion based on a medically relevant difference between an RM and CS results to make a conclusion regarding commutability. When more than 2 MPs are included, the commutability is assessed pairwise for all combinations of 2 MPs. This approach allows the same criterion to be used for all combinations of MPs included in the assessment. The assessment is based on an error model that allows estimation of various random and systematic sources of error, including those from sample-specific effects of interfering substances. An advantage of this approach is that the difference in bias between an RM and the average bias of CSs at the concentration (i.e., amount of substance present or quantity value) of the RM is determined and its uncertainty estimated. An RM is considered fit for purpose for those MPs for which commutability is demonstrated.


Assuntos
Técnicas de Laboratório Clínico/normas , Viés , Técnicas de Laboratório Clínico/estatística & dados numéricos , Interpretação Estatística de Dados , Humanos , Padrões de Referência , Manejo de Espécimes/normas , Incerteza
16.
Anal Bioanal Chem ; 410(9): 2321-2329, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29435636

RESUMO

Dietary fatty acids can be both beneficial and detrimental to human health depending on the degree and type of saturation. Healthcare providers and research scientists monitor the fatty acid content of human plasma and serum as an indicator of health status and diet. In addition, both the Centers for Disease Control & Prevention (CDC) and the National Institutes of Health - Office of Dietary Supplements are interested in circulating fatty acids (FAs) because they may be predictive of coronary heart disease. The National Institute of Standards and Technology (NIST) provides a wide variety of reference materials (RMs) and Standard Reference Materials® (SRM®s) including blood, serum, plasma, and urine with values assigned for analytes of clinical interest. NIST SRM 2378 Fatty Acids in Frozen Human Serum was introduced in 2015 to help validate methods used for the analysis of FAs in serum, and consists of three different pools of serum acquired from (1) healthy donors who had taken fish oil dietary supplements (at least 1000 mg per day) for at least one month (level 1 material), (2) healthy donors who had taken flaxseed oil dietary supplements (at least 1000 mg per day) for at least one month (level 2 material), and (3) healthy donors eating "normal" diets who had not taken dietary supplements containing fish or plant oils (level 3 material). The use of dietary supplements by donors provided SRMs with natural endogenous ranges of FAs at concentrations observed in human populations. Results from analyses using two methods at NIST, including one involving a novel microwave-assisted acid hydrolysis procedure, and one at the CDC are presented here. These results and their respective uncertainties were combined to yield certified values with expanded uncertainties for 12 FAs and reference values with expanded uncertainties for an additional 18 FAs.


Assuntos
Cromatografia Gasosa/métodos , Suplementos Nutricionais , Ácidos Graxos/sangue , Ionização de Chama/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Preservação de Sangue , Cromatografia Gasosa/normas , Criopreservação , Suplementos Nutricionais/análise , Ácidos Graxos/normas , Ácidos Graxos Insaturados/sangue , Ácidos Graxos Insaturados/normas , Óleos de Peixe/administração & dosagem , Óleos de Peixe/sangue , Ionização de Chama/normas , Congelamento , Cromatografia Gasosa-Espectrometria de Massas/normas , Humanos , Óleos de Plantas/administração & dosagem , Óleos de Plantas/análise , Padrões de Referência
17.
Anal Chem ; 89(9): 4907-4913, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28375002

RESUMO

The National Institute of Standards and Technology (NIST) has developed Standard Reference Material (SRM) 972a Vitamin D Metabolites in Frozen Human Serum as a replacement for SRM 972, which is no longer available. SRM 972a was developed in collaboration with the National Institutes of Health's Office of Dietary Supplements. In contrast to the previous reference material, three of the four levels of SRM 972a are composed of unmodified human serum. This SRM has certified and reference values for the following 25-hydroxyvitamin D [25(OH)D] species: 25(OH)D2, 25(OH)D3, and 3-epi-25(OH)D3. The value assignment and certification process included three isotope-dilution mass spectrometry approaches, with measurements performed at NIST and at the Centers for Disease Control and Prevention (CDC). The value assignment methods employed have been modified from those utilized for the previous SRM, and all three approaches now incorporate chromatographic resolution of the stereoisomers, 25(OH)D3 and 3-epi-25(OH)D3.


Assuntos
25-Hidroxivitamina D 2/sangue , Calcifediol/sangue , Cromatografia Líquida/normas , Espectrometria de Massas/normas , 25-Hidroxivitamina D 2/normas , Calcifediol/química , Calcifediol/normas , Humanos , Padrões de Referência , Valores de Referência , Estereoisomerismo , Estados Unidos , United States Government Agencies
18.
Anal Chem ; 85(24): 11732-8, 2013 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-24187941

RESUMO

The National Institute of Standards and Technology (NIST), in collaboration with the National Institutes of Health (NIH), has developed a Standard Reference Material (SRM) to support technology development in metabolomics research. SRM 1950 Metabolites in Human Plasma is intended to have metabolite concentrations that are representative of those found in adult human plasma. The plasma used in the preparation of SRM 1950 was collected from both male and female donors, and donor ethnicity targets were selected based upon the ethnic makeup of the U.S. population. Metabolomics research is diverse in terms of both instrumentation and scientific goals. This SRM was designed to apply broadly to the field, not toward specific applications. Therefore, concentrations of approximately 100 analytes, including amino acids, fatty acids, trace elements, vitamins, hormones, selenoproteins, clinical markers, and perfluorinated compounds (PFCs), were determined. Value assignment measurements were performed by NIST and the Centers for Disease Control and Prevention (CDC). SRM 1950 is the first reference material developed specifically for metabolomics research.


Assuntos
Análise Química do Sangue/normas , Metabolômica/normas , Adulto , Aminoácidos/sangue , Biomarcadores/sangue , Carotenoides/sangue , Ácidos Graxos/sangue , Feminino , Humanos , Masculino , National Institutes of Health (U.S.) , Padrões de Referência , Estados Unidos , Vitaminas/sangue
19.
Anal Bioanal Chem ; 405(13): 4561-8, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23354578

RESUMO

The National Institute of Standards and Technology (NIST) is developing a wide variety of Standard Reference Materials (SRMs) to support measurements of vitamins and other nutrients in foods. Previously, NIST has provided SRMs with values assigned for the folate vitamer, folic acid (pteroylglutamic acid), which is fortified in several foods due to its role in prevention of neural tube defects. In order to expand the number of food-based SRMs with values assigned for folic acid, as well as additional endogenous folates, NIST has developed methods that include trienzyme digestion and isotope-dilution liquid chromatography-tandem mass spectrometric (LC-MS/MS) analysis. Sample preparation was optimized for each individual food type, but all samples were analyzed under the same LC-MS/MS conditions. The application of these methods resulted in folic acid values for SRM 1849a Infant/Adult Nutritional Formula and SRM 3233 Fortified Breakfast Cereal of (2.33 ± 0.06) µg/g and (16.0 ± 0.7) µg/g, respectively. In addition, the endogenous folate vitamer 5-methlytetrahydrofolate (5-MTHF) was detected and quantified in SRM 1849a Infant/Adult Nutritional Formula, candidate SRM 1549a Whole Milk Powder, and candidate SRM 1845a Whole Egg Powder, resulting in values of (0.0839 ± 0.0071) µg/g, (0.211 ± 0.014) µg/g, and (0.838 ± 0.044) µg/g, respectively. SRM 1849a Infant/Adult Nutritional Formula is the first food-based NIST SRM to possess a reference value for 5-MTHF and the first certified reference material to have an assigned 5-MTHF value based on LC-MS/MS. The values obtained for folic acid and 5-MTHF by LC-MS/MS will be incorporated into the final value assignments for all these food-based SRMs.


Assuntos
Grão Comestível/química , Ácido Fólico/normas , Alimentos Formulados/normas , Tetra-Hidrofolatos/normas , Cromatografia Líquida , Ácido Fólico/análise , Análise de Alimentos , Alimentos Formulados/análise , Humanos , Lactente , Controle de Qualidade , Padrões de Referência , Valores de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Tetra-Hidrofolatos/análise
20.
J Steroid Biochem Mol Biol ; 231: 106318, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37169270

RESUMO

Ninety archived human serum samples from the Vitamin D External Quality Assessment Scheme (DEQAS) were analyzed using a reference measurement procedure (RMP) based on isotope dilution liquid chromatography - tandem mass spectrometry (ID LC-MS/MS) for the determination of 24,25-dihydroxyvitamin D3 [24,25(OH)2D3]. These 24,25(OH)2D3 results, in conjunction with concentration values assigned using RMPs for 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3], provide a valuable resource for assessing the accuracy of measurements for 24,25(OH)2D3 and for investigating the relationship between 24,25(OH)2D3 and 25(OH)D3. Results for 24,25(OH)2D3 using the RMP were compared to DEQAS consensus values demonstrating that the consensus values were not sufficient to assess the accuracy of measurements among different laboratories and methods. A multivariable regression analysis approach using historical DEQAS consensus values for various total 25(OH)D assays was used to assess the contribution of 24,25(OH)2D3 concentration on the assay response. The response of several ligand binding assays for total 25(OH)D was shown to be impacted by the presence of 24,25(OH)2D3.


Assuntos
Espectrometria de Massas em Tandem , Vitamina D , Humanos , Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Vitaminas , Calcifediol , 24,25-Di-Hidroxivitamina D 3
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA