Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Magn Reson Imaging ; 55(3): 698-719, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33314349

RESUMO

Arterial spin labeling (ASL) is a powerful noncontrast magnetic resonance imaging (MRI) technique that enables quantitative evaluation of brain perfusion. To optimize the clinical and research utilization of ASL, radiologists and physicists must understand the technical considerations and age-related variations in normal and disease states. We discuss advanced applications of ASL across the lifespan, with example cases from children and adults covering a wide variety of pathologies. Through literature review and illustrated clinical cases, we highlight the subtleties as well as pitfalls of ASL interpretation. First, we review basic physical principles, techniques, and artifacts. This is followed by a discussion of normal perfusion variants based on age and physiology. The three major categories of perfusion abnormalities-hypoperfusion, hyperperfusion, and mixed patterns-are covered with an emphasis on clinical interpretation and relationship to the disease process. Major etiologies of hypoperfusion include large artery, small artery, and venous disease; other vascular conditions; global hypoxic-ischemic injury; and neurodegeneration. Hyperperfusion is characteristic of vascular malformations and tumors. Mixed perfusion patterns can be seen with epilepsy, migraine, trauma, infection/inflammation, and toxic-metabolic encephalopathy. LEVEL OF EVIDENCE: 4 TECHNICAL EFFICACY STAGE: 3.


Assuntos
Encefalopatias , Circulação Cerebrovascular , Adulto , Artérias , Encefalopatias/diagnóstico por imagem , Circulação Cerebrovascular/fisiologia , Criança , Humanos , Angiografia por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/métodos , Marcadores de Spin
2.
J Magn Reson Imaging ; 55(1): 166-175, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34184362

RESUMO

BACKGROUND: A low-cryogen, compact 3T (C3T) MRI scanner with high-performance gradients capable of simultaneously achieving 80 mT/m gradient amplitude and 700 T/m/second slew rate has been in use to study research patients since March 2016 but has not been implemented in the clinical practice. PURPOSE: To compare head MRI examinations obtained with the C3T system and a conventional whole-body 3T (WB3T) scanner in seven parameters across five commonly used brain imaging sequences. STUDY TYPE: Prospective. SUBJECTS: Thirty patients with a clinically indicated head MRI. SEQUENCE: 3T; T1 FLAIR, T1 MP-RAGE, 3D T2 FLAIR, T2 FSE, and DWI. ASSESSMENT: All patients tolerated the scans well. Three board-certified neuroradiologists scored the comparative quality of C3T and WB3T images in blinded fashion using a five-point Likert scale in terms of: signal-to-noise ratio, lesion conspicuity, motion artifact, gray/white matter contrast, cerebellar folia, susceptibility artifact, and overall quality. STATISTICAL TEST: Left-sided, right-sided, and two-sided Wilcoxon signed rank test; Fisher's method. A P value <0.05 was considered statistically significant. RESULTS: The C3T system performed better than the WB3T in virtually all comparisons, except for motion artifacts for the T1 FLAIR and T1 MP-RAGE sequences, where the WB3T system was deemed better. When combining all sequences together, the C3T system outperformed the WB3T system in all image quality parameters evaluated, except for motion artifact (P = 0.13). DATA CONCLUSION: The C3T scanner provided better overall image quality for all sequences, and performed better in all individual categories, except for motion artifact on the T1 FLAIR and T1 MP-RAGE. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Encéfalo , Imageamento por Ressonância Magnética , Artefatos , Encéfalo/diagnóstico por imagem , Substância Cinzenta , Humanos , Estudos Prospectivos
3.
AJR Am J Roentgenol ; 216(2): 552-559, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33236945

RESUMO

OBJECTIVE. The Adaptive Image Receive (AIR) radiofrequency coil is an emergent technology that is lightweight and flexible and exhibits electrical characteristics that overcome many of the limitations of traditional rigid coil designs. The purpose of this study was to apply the AIR coil for whole-brain imaging and compare the performance of a prototype AIR coil array with the performance of conventional head coils. SUBJECTS AND METHODS. A phantom and 15 healthy adult participants were imaged. A prototype 16-channel head AIR coil was compared with conventional 8-and 32-channel head coils using clinically available MRI sequences. During consensus review, two board-certified neuroradiologists graded the AIR coil compared with an 8-channel coil and a 32-channel coil on a 5-point ordinal scale in multiple categories. One- and two-sided Wilcoxon signed rank tests were performed. Noise covariance matrices and geometry factor (g-factor) maps were calculated. RESULTS. The signal-to-noise ratio, structural sharpness, and overall image quality scores of the prototype 16-channel AIR coil were better than those of the 8-channel coil but were not as good as those of the 32-channel coil. Noise covariance matrices showed stable performance of the AIR coil across participants. The median g-factors for the 16-channel AIR coil were, overall, less than those of the 8-channel coil but were greater than those of the 32-channel coil. CONCLUSION. On average, the prototype 16-channel head AIR coil outperformed a conventional 8-channel head coil but did not perform as well as a conventional 32-channel head coil. This study shows the feasibility of the novel AIR coil technology for imaging the brain and provides insight for future coil design improvements.


Assuntos
Artefatos , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Neuroimagem , Adulto , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Razão Sinal-Ruído , Adulto Jovem
4.
MAGMA ; 34(5): 697-706, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33945050

RESUMO

PURPOSE: MR fingerprinting (MRF) is a MR technique that allows assessment of tissue relaxation times. The purpose of this study is to evaluate the clinical application of this technique in patients with meningioma. MATERIALS AND METHODS: A whole-brain 3D isotropic 1mm3 acquisition under a 3.0T field strength was used to obtain MRF T1 and T2-based relaxometry values in 4:38 s. The accuracy of values was quantified by scanning a quantitative MR relaxometry phantom. In vivo evaluation was performed by applying the sequence to 20 subjects with 25 meningiomas. Regions of interest included the meningioma, caudate head, centrum semiovale, contralateral white matter and thalamus. For both phantom and subjects, mean values of both T1 and T2 estimates were obtained. Statistical significance of differences in mean values between the meningioma and other brain structures was tested using a Friedman's ANOVA test. RESULTS: MR fingerprinting phantom data demonstrated a linear relationship between measured and reference relaxometry estimates for both T1 (r2 = 0.99) and T2 (r2 = 0.97). MRF T1 relaxation times were longer in meningioma (mean ± SD 1429 ± 202 ms) compared to thalamus (mean ± SD 1054 ± 58 ms; p = 0.004), centrum semiovale (mean ± SD 825 ± 42 ms; p < 0.001) and contralateral white matter (mean ± SD 799 ± 40 ms; p < 0.001). MRF T2 relaxation times were longer for meningioma (mean ± SD 69 ± 27 ms) as compared to thalamus (mean ± SD 27 ± 3 ms; p < 0.001), caudate head (mean ± SD 39 ± 5 ms; p < 0.001) and contralateral white matter (mean ± SD 35 ± 4 ms; p < 0.001) CONCLUSIONS: Phantom measurements indicate that the proposed 3D-MRF sequence relaxometry estimations are valid and reproducible. For in vivo, entire brain coverage was obtained in clinically feasible time and allows quantitative assessment of meningioma in clinical practice.


Assuntos
Neoplasias Meníngeas , Meningioma , Encéfalo/diagnóstico por imagem , Estudos de Viabilidade , Humanos , Imageamento por Ressonância Magnética , Neoplasias Meníngeas/diagnóstico por imagem , Meningioma/diagnóstico por imagem , Imagens de Fantasmas
5.
BMC Med Imaging ; 21(1): 88, 2021 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-34022832

RESUMO

BACKGROUND: MR fingerprinting (MRF) is a novel imaging method proposed for the diagnosis of Multiple Sclerosis (MS). This study aims to determine if MR Fingerprinting (MRF) relaxometry can differentiate frontal normal appearing white matter (F-NAWM) and splenium in patients diagnosed with MS as compared to controls and to characterize the relaxometry of demyelinating plaques relative to the time of diagnosis. METHODS: Three-dimensional (3D) MRF data were acquired on a 3.0T MRI system resulting in isotropic voxels (1 × 1 × 1 mm3) and a total acquisition time of 4 min 38 s. Data were collected on 18 subjects paired with 18 controls. Regions of interest were drawn over MRF-derived T1 relaxometry maps encompassing selected MS lesions, F-NAWM and splenium. T1 and T2 relaxometry features from those segmented areas were used to classify MS lesions from F-NAWM and splenium with T-distributed stochastic neighbor embedding algorithms. Partial least squares discriminant analysis was performed to discriminate NAWM and Splenium in MS compared with controls. RESULTS: Mean out-of-fold machine learning prediction accuracy for discriminant results between MS patients and controls for F-NAWM was 65 % (p = 0.21) and approached 90 % (p < 0.01) for the splenium. There was significant positive correlation between time since diagnosis and MS lesions mean T2 (p = 0.015), minimum T1 (p = 0.03) and negative correlation with splenium uniformity (p = 0.04). Perfect discrimination (AUC = 1) was achieved between selected features from MS lesions and F-NAWM. CONCLUSIONS: 3D-MRF has the ability to differentiate between MS and controls based on relaxometry properties from the F-NAWM and splenium. Whole brain coverage allows the assessment of quantitative properties within lesions that provide chronological assessment of the time from MS diagnosis.


Assuntos
Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Área Sob a Curva , Estudos de Casos e Controles , Corpo Caloso/diagnóstico por imagem , Feminino , Humanos , Análise dos Mínimos Quadrados , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Substância Branca/diagnóstico por imagem
6.
Lancet ; 392(10162): 2388-2396, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30318264

RESUMO

BACKGROUND: Non-contrast head CT scan is the current standard for initial imaging of patients with head trauma or stroke symptoms. We aimed to develop and validate a set of deep learning algorithms for automated detection of the following key findings from these scans: intracranial haemorrhage and its types (ie, intraparenchymal, intraventricular, subdural, extradural, and subarachnoid); calvarial fractures; midline shift; and mass effect. METHODS: We retrospectively collected a dataset containing 313 318 head CT scans together with their clinical reports from around 20 centres in India between Jan 1, 2011, and June 1, 2017. A randomly selected part of this dataset (Qure25k dataset) was used for validation and the rest was used to develop algorithms. An additional validation dataset (CQ500 dataset) was collected in two batches from centres that were different from those used for the development and Qure25k datasets. We excluded postoperative scans and scans of patients younger than 7 years. The original clinical radiology report and consensus of three independent radiologists were considered as gold standard for the Qure25k and CQ500 datasets, respectively. Areas under the receiver operating characteristic curves (AUCs) were primarily used to assess the algorithms. FINDINGS: The Qure25k dataset contained 21 095 scans (mean age 43 years; 9030 [43%] female patients), and the CQ500 dataset consisted of 214 scans in the first batch (mean age 43 years; 94 [44%] female patients) and 277 scans in the second batch (mean age 52 years; 84 [30%] female patients). On the Qure25k dataset, the algorithms achieved an AUC of 0·92 (95% CI 0·91-0·93) for detecting intracranial haemorrhage (0·90 [0·89-0·91] for intraparenchymal, 0·96 [0·94-0·97] for intraventricular, 0·92 [0·90-0·93] for subdural, 0·93 [0·91-0·95] for extradural, and 0·90 [0·89-0·92] for subarachnoid). On the CQ500 dataset, AUC was 0·94 (0·92-0·97) for intracranial haemorrhage (0·95 [0·93-0·98], 0·93 [0·87-1·00], 0·95 [0·91-0·99], 0·97 [0·91-1·00], and 0·96 [0·92-0·99], respectively). AUCs on the Qure25k dataset were 0·92 (0·91-0·94) for calvarial fractures, 0·93 (0·91-0·94) for midline shift, and 0·86 (0·85-0·87) for mass effect, while AUCs on the CQ500 dataset were 0·96 (0·92-1·00), 0·97 (0·94-1·00), and 0·92 (0·89-0·95), respectively. INTERPRETATION: Our results show that deep learning algorithms can accurately identify head CT scan abnormalities requiring urgent attention, opening up the possibility to use these algorithms to automate the triage process. FUNDING: Qure.ai.


Assuntos
Algoritmos , Lesões Encefálicas/diagnóstico por imagem , Aprendizado Profundo , Hemorragias Intracranianas/diagnóstico por imagem , Fraturas Cranianas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Triagem/métodos , Conjuntos de Dados como Assunto , Cabeça/diagnóstico por imagem , Humanos , Estudos Retrospectivos , Índices de Gravidade do Trauma
7.
Radiographics ; 39(3): 729-743, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31059394

RESUMO

Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.


Assuntos
Fótons , Tomografia Computadorizada por Raios X/métodos , Animais , Meios de Contraste , Desenho de Equipamento , Humanos , Compostos de Iodo , Doses de Radiação , Razão Sinal-Ruído , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/tendências
9.
Magn Reson Med ; 80(4): 1556-1567, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29488251

RESUMO

PURPOSE: Dixon-based fat suppression has recently gained interest for dynamic contrast-enhanced MRI, but multi-echo techniques require longer scan times and reduce temporal resolution compared to single-echo alternatives without fat suppression. The purpose of this work is to demonstrate accelerated single-echo Dixon imaging with high spatial and temporal resolution. THEORY AND METHODS: Real-valued water and fat images can be obtained from a single measurement if the shared initial phase and that due to ΔB0 are assumed known a priori. An expression for simultaneous sensitivity encoding (SENSE) unfolding and fat-water separation is derived for the general undersampling case, and simplified under the special case of uniform Cartesian undersampling. In vivo experiments were performed in extremities and brain with SENSE acceleration factors of up to R = 8. RESULTS: Single-echo Dixon reconstruction of highly undersampled data was successfully demonstrated. Dynamic contrast-enhanced water and fat images provided high spatial and temporal resolution dynamic images with image update times shorter than previous single-echo Dixon work. CONCLUSION: Time-resolved contrast-enhanced MRI with single-echo Dixon fat suppression shows high image quality, improved vessel delineation, and reduced sensitivity to motion when compared to time-subtraction methods.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Tecido Adiposo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Meios de Contraste , Mãos/irrigação sanguínea , Mãos/diagnóstico por imagem , Humanos , Processamento de Sinais Assistido por Computador , Água/química
10.
Magn Reson Med ; 80(5): 2232-2245, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29536587

RESUMO

PURPOSE: To build and evaluate a small-footprint, lightweight, high-performance 3T MRI scanner for advanced brain imaging with image quality that is equal to or better than conventional whole-body clinical 3T MRI scanners, while achieving substantial reductions in installation costs. METHODS: A conduction-cooled magnet was developed that uses less than 12 liters of liquid helium in a gas-charged sealed system, and standard NbTi wire, and weighs approximately 2000 kg. A 42-cm inner-diameter gradient coil with asymmetric transverse axes was developed to provide patient access for head and extremity exams, while minimizing magnet-gradient interactions that adversely affect image quality. The gradient coil was designed to achieve simultaneous operation of 80-mT/m peak gradient amplitude at a slew rate of 700 T/m/s on each gradient axis using readily available 1-MVA gradient drivers. RESULTS: In a comparison of anatomical imaging in 16 patients using T2 -weighted 3D fluid-attenuated inversion recovery (FLAIR) between the compact 3T and whole-body 3T, image quality was assessed as equivalent to or better across several metrics. The ability to fully use a high slew rate of 700 T/m/s simultaneously with 80-mT/m maximum gradient amplitude resulted in improvements in image quality across EPI, DWI, and anatomical imaging of the brain. CONCLUSIONS: The compact 3T MRI system has been in continuous operation at the Mayo Clinic since March 2016. To date, over 200 patient studies have been completed, including 96 comparison studies with a clinical 3T whole-body MRI. The increased gradient performance has reliably resulted in consistently improved image quality.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Imagem Corporal Total/instrumentação , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Feminino , Humanos , Imageamento Tridimensional , Imãs , Masculino , Imagens de Fantasmas , Razão Sinal-Ruído
11.
Pediatr Radiol ; 47(5): 544-555, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28409252

RESUMO

Pediatric neuroimaging is a complex and specialized field that uses magnetic resonance (MR) imaging as the workhorse for diagnosis. MR protocols should be tailored to the specific indication and reviewed by the supervising radiologist in real time. Targeted advanced imaging sequences can be added to provide information regarding tissue microstructure, perfusion, metabolism and function. In part 2 of this review, we highlight the utility of advanced imaging techniques for superior evaluation of pediatric neurologic disease. We focus on the following techniques, with clinical examples: phase-contrast imaging, perfusion-weighted imaging, vessel wall imaging, diffusion tensor imaging, task-based functional MRI and MR spectroscopy.


Assuntos
Encefalopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Encéfalo/diagnóstico por imagem , Criança , Humanos
12.
Pediatr Radiol ; 47(5): 534-543, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28409254

RESUMO

Pediatric neuroimaging is a complex and specialized field that uses magnetic resonance (MR) imaging as the workhorse for diagnosis. Standard MR techniques used in adult neuroimaging are suboptimal for imaging in pediatrics because there are significant differences in the child's developing brain. These differences include size, myelination and sulcation. MR protocols need to be tailored to the specific indication and reviewed by the supervising radiologist in real time, and the specialized needs of this population require careful consideration of issues such as scan timing, sequence order, sedation, anesthesia and gadolinium administration. In part 1 of this review, we focus on basic protocol development and anatomical characterization. We provide multiple imaging examples optimized for evaluation of supratentorial and infratentorial brain, midline structures, head and neck, and intracranial vasculature.


Assuntos
Encefalopatias/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Neuroimagem/métodos , Encéfalo/diagnóstico por imagem , Criança , Humanos
13.
Neuroradiology ; 58(11): 1087-1091, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27704163

RESUMO

INTRODUCTION: Ferumoxytol (Feraheme) is a parenteral therapy approved for treatment of iron deficiency anemia. The product insert for ferumoxytol states that it may affect the diagnostic ability of MRI for up to 3 months. However, the expected effects may not be commonly recognized among clinical neuroradiologists. Our purpose is to describe the artifacts we have seen at our institution during routine clinical practice. METHODS: We reviewed the patients at our institution that had brain MRI performed within 90 days of receiving intravenous ferumoxytol. The imaging was reviewed for specific findings, including diffusion-weighted imaging vascular susceptibility artifact, gradient-echo echo-planar T2*-weighted vascular susceptibility artifact, SWI/SWAN vascular susceptibility artifact, hypointense vascular signal on T2-weighted images, pre-gadolinium contrast vascular enhancement on magnetization-prepared rapid acquisition gradient echo (MPRAGE) imaging, and effects on post-gadolinium contrast T1 imaging. RESULTS: Multiple artifacts were observed in patients having a brain MRI within 3 days of receiving intravenous ferumoxytol. These included susceptibility artifact on DWI, GRE, and SWAN/SWI imaging, pre-gadolinium contrast increased vascular signal on MPRAGE imaging, and decreased expected enhancement on post-gadolinium contrast T1-weighted imaging. CONCLUSION: Ferumoxytol can create imaging artifacts which complicate clinical interpretation when brain MRI is performed within 3 days of administration. Recognition of the constellation of artifacts produced by ferumoxytol is important in order to obviate additional unnecessary examinations and mitigate errors in interpretation.


Assuntos
Artefatos , Encéfalo/efeitos dos fármacos , Encéfalo/diagnóstico por imagem , Óxido Ferroso-Férrico/administração & dosagem , Achados Incidentais , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Meios de Contraste/administração & dosagem , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
J Comput Assist Tomogr ; 39(3): 317-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25783798

RESUMO

BACKGROUND AND PURPOSE: The purpose of this study was to determine if magnetic resonance (MR) susceptibility-weighted imaging (SWI) can increase the conspicuity of corticomedullary veins within the white matter lesions of multiple sclerosis (MS) and, thus, aid in distinguishing plaques from leukoaraiosis. METHODS: We retrospectively reviewed MR examinations in 21 patients with a clinical diagnosis of MS and 18 patients with a clinical diagnosis of dementia. Examinations included fluid-attenuated inversion recovery (FLAIR) and SWI sequences obtained in the axial plane. Lesions greater than 5 mm in diameter on the axial FLAIR sequence were identified as periventricular or subcortical. Three neuroradiologists evaluated SWI images, compared with FLAIR, for a centrally located signal void in each lesion that was scored as present, absent, or indeterminate. RESULTS: In patients with MS, central veins were present in both periventricular lesions (75%, P < 0.001) and subcortical lesions (52%, P < 0.005). In patients with dementia, central veins were seen much less frequently in subcortical lesions (14%, P < 0.001); their association with periventricular lesions was not significant. CONCLUSIONS: Central veins were detected in MS lesions with a significantly greater frequency than that in patients with dementia. Susceptibility-weighted imaging increases the conspicuity of corticomedullary veins and may improve the specificity of MR findings in MS.


Assuntos
Veias Cerebrais/patologia , Transtornos Cerebrovasculares/patologia , Demência/patologia , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/patologia , Placa Aterosclerótica/patologia , Substância Branca/patologia , Idoso , Diagnóstico Diferencial , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
16.
Radiol Case Rep ; 19(4): 1254-1257, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38292796

RESUMO

Dorsal arachnoid webs are uncommon, and of uncertain etiology. We present a case in which imaging findings of a dorsal arachnoid web were identified at the level of a known prior gunshot injury where a retained bullet was lodged adjacent to the spine, without associated penetrating injury to the spine, suggesting blunt post-traumatic etiology.

17.
Artigo em Inglês | MEDLINE | ID: mdl-38964861

RESUMO

Photon-counting detectors (PCDs) represent a major milestone in the evolution of CT imaging. CT scanners using PCD systems have already been shown to generate images with substantially greater spatial resolution, superior iodine contrast-to-noise ratio, and reduced artifact compared with conventional energy-integrating detector-based systems. These benefits can be achieved with considerably decreased radiation dose. Recent studies have focused on the advantages of PCD-CT scanners in numerous anatomic regions, particularly the coronary and cerebral vasculature, pulmonary structures, and musculoskeletal imaging. However, PCD-CT imaging is also anticipated to be a major advantage for head and neck imaging. In this paper, we review current clinical applications of PCD-CT in head and neck imaging, with a focus on the temporal bone, facial bones, and paranasal sinuses; minor arterial vasculature; and the spectral capabilities of PCD systems.

18.
Magn Reson Imaging ; 109: 189-202, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38490504

RESUMO

BACKGROUND: Echo planar imaging (EPI) is a fast measurement technique commonly used in magnetic resonance imaging (MRI), but is highly sensitive to measurement non-idealities in reconstruction. Point spread function (PSF)-encoded EPI is a multi-shot strategy which alleviates distortion, but acquisition of encodings suitable for direct distortion-free imaging prolongs scan time. In this work, a model-based iterative reconstruction (MBIR) framework is introduced for direct imaging with PSF-EPI to improve image quality and acceleration potential. METHODS: An MBIR platform was developed for accelerated PSF-EPI. The reconstruction utilizes a subspace representation, is regularized to promote local low-rankedness (LLR), and uses variable splitting for efficient iteration. Comparisons were made against standard reconstructions from prospectively accelerated PSF-EPI data and with retrospective subsampling. Exploring aggressive partial Fourier acceleration of the PSF-encoding dimension, additional comparisons were made against an extension of Homodyne to direct PSF-EPI in numerical experiments. A neuroradiologists' assessment was completed comparing images reconstructed with MBIR from retrospectively truncated data directly against images obtained with standard reconstructions from non-truncated datasets. RESULTS: Image quality results were consistently superior for MBIR relative to standard and Homodyne reconstructions. As the MBIR signal model and reconstruction allow for arbitrary sampling of the PSF space, random sampling of the PSF-encoding dimension was also demonstrated, with quantitative assessments indicating best performance achieved through nonuniform PSF sampling combined with partial Fourier. With retrospective subsampling, MBIR reconstructs high-quality images from sub-minute scan datasets. MBIR was shown to be superior in a neuroradiologists' assessment with respect to three of five performance criteria, with equivalence for the remaining two. CONCLUSIONS: A novel image reconstruction framework is introduced for direct imaging with PSF-EPI, enabling arbitrary PSF space sampling and reconstruction of diagnostic-quality images from highly accelerated PSF-encoded EPI data.


Assuntos
Encéfalo , Imagem Ecoplanar , Estudos Retrospectivos , Imagem Ecoplanar/métodos , Encéfalo/diagnóstico por imagem , Algoritmos , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos
19.
Artigo em Inglês | MEDLINE | ID: mdl-38906672

RESUMO

Giant cell arteritis (GCA) is the most common primary large vessel systemic vasculitis in the western world. Even though the involvement of scalp and intracranial vessels has received much attention in the neuroradiology literature, GCA, being a systemic vasculitis can involve multiple other larger vessels including aorta and its major head and neck branches. Herein, the authors present a pictorial review of the various cranial, extracranial and orbital manifestations of GCA. An increased awareness of this entity may help with timely and accurate diagnosis, helping expedite therapy and preventing serious complications.ABBREVIATIONS: ACR= American College of Rheumatology, AION= Anterior Ischemic Optic Neuropathy, EULAR= European League Against Rheumatism, GCA= Giant Cell Arteritis, LV-GCA= Large vessel GCA, PMR= Polymyalgia Rheumatica, US= Ultrasound, VWI= Vessel Wall Imaging.

20.
AJR Am J Roentgenol ; 200(1): 50-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23255741

RESUMO

OBJECTIVE: The tumefactive variant of cerebral amyloid angiopathy (CAA) is rare. In this article we describe imaging findings associated with this entity and evaluate the role of susceptibility MRI sequences in its diagnosis. CONCLUSION: Our findings suggest that in elderly patients, susceptibility sequences should be part of prebiopsy MRI for tumefactive lesions. Identification of characteristic diffuse microhemorrhages should prompt inclusion of CAA in the differential diagnosis, targeted biopsy of the cortex and leptomeninges, and pathologic staining for CAA.


Assuntos
Neoplasias Encefálicas/diagnóstico , Encéfalo/patologia , Angiopatia Amiloide Cerebral/diagnóstico , Imageamento por Ressonância Magnética , Idoso , Biópsia , Angiopatia Amiloide Cerebral/patologia , Hemorragia Cerebral/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA