Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 189
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 402(10412): 1529-1540, 2023 10 28.
Artigo em Inglês | MEDLINE | ID: mdl-37660719

RESUMO

BACKGROUND: With increasing numbers of patients undergoing transcatheter aortic valve replacement (TAVR), data on management of failed TAVR, including repeat TAVR procedure, are needed. The aim of this study was to assess the safety and efficacy of redo-TAVR in a national registry. METHODS: This study included all consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry from Nov 9, 2011, to Dec 30, 2022 who underwent TAVR with balloon-expandable valves in failed transcatheter heart valves (redo-TAVR) or native aortic valves (native-TAVR). Procedural, echocardiographic, and clinical outcomes were compared between redo-TAVR and native-TAVR cohorts using propensity score matching. FINDINGS: Among 350 591 patients (1320 redo-TAVR; 349 271 native-TAVR), 1320 propensity-matched pairs of patients undergoing redo-TAVR and native-TAVR were analysed (redo-TAVR cohort: mean age 78 years [SD 9]; 559 [42·3%] of 1320 female, 761 [57·7%] male; mean predicted surgical risk of 30-day mortality 8·1%). The rates of procedural complications of redo-TAVR were low (coronary compression or obstruction: four [0·3%] of 1320; intraprocedural death: eight [0·6%] of 1320; conversion to open heart surgery: six [0·5%] of 1319) and similar to native-TAVR. There was no significant difference between redo-TAVR and native-TAVR populations in death at 30 days (4·7% vs 4·0%, p=0·36) or 1 year (17·5% vs 19·0%, p=0·57), and stroke at 30 days (2·0% vs 1·9%, p=0·84) or 1 year (3·2% vs 3·5%, p=0·80). Redo-TAVR reduced aortic valve gradients at 1 year, although they were higher in the redo-TAVR group compared with the native-TAVR group (15 mm Hg vs 12 mm Hg; p<0·0001). Moderate or severe aortic regurgitation rates were similar between redo-TAVR and native-TAVR groups at 1 year (1·8% vs 3·3%, p=0·18). Death or stroke after redo-TAVR were not significantly affected by the timing of redo-TAVR (before or after 1 year of index TAVR), or by index transcatheter valve type (balloon-expandable or non-balloon-expandable). INTERPRETATION: Redo-TAVR with balloon-expandable valves effectively treated dysfunction of the index TAVR procedure with low procedural complication rates, and death and stroke rates similar to those in patients with a similar clinical profile and predicted risk undergoing TAVR for native aortic valve stenosis. Redo-TAVR with balloon-expandable valves might be a reasonable treatment for failed TAVR in selected patients. FUNDING: Edwards Lifesciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Substituição da Valva Aórtica Transcateter/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Acidente Vascular Cerebral/etiologia , Sistema de Registros , Fatores de Risco , Desenho de Prótese
2.
Am Heart J ; 264: 59-71, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37276912

RESUMO

BACKGROUND: There is scarce data on transcatheter edge-to-edge repair (TEER) for chronic functional mitral regurgitation (FMR) in the setting of very severe left ventricular dysfunction (LVD), defined by a left ventricular ejection fraction (LVEF) of <20%. METHODS: We retrospectively explored periprocedural characteristics and one-year clinical and echocardiographic outcomes of consecutive patients with chronic FMR and very severe LVD who underwent an isolated, first-time TEER. The composite of all-cause mortality or heart failure hospitalizations constituted the primary outcome. RESULTS: Ninety-six patients (median age 69 [IQR, 55-76] years, 64 (66.7%) males, median LVEF 15 [IQR, 12-17] %) were included. In 47 (49.0%), TEER was performed urgently or in the setting of hemodynamic instability. Almost all procedures (98.0%) were technically successful, leading to ≤moderate MR in 94.7% and 90.7% of cases by 1-month and 1-year, respectively. New York Heart Association class ≤II was maintained in 60.0% of patients. One-year survival and freedom from the primary outcome were 74.0% and 50.0%, respectively. Functional and echocardiographic improvement compared to baseline was independent of procedural urgency, hemodynamic stability, and downstream left ventricular assist device implantation / heart transplantation (n = 12). Mortality was not predicted by COAPT exclusion criteria, nor was the primary outcome discriminated by published risk models. CONCLUSION: TEER for chronic FMR is feasible, safe, and efficacious in selected patients with very severe LVD. Preprocedural risk stratification in this population may be optimized.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Disfunção Ventricular Esquerda , Masculino , Humanos , Idoso , Feminino , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Função Ventricular Esquerda , Volume Sistólico , Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Implante de Prótese de Valva Cardíaca/métodos
3.
Catheter Cardiovasc Interv ; 101(3): 596-604, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36740240

RESUMO

BACKGROUND: Limited data exist regarding the performance of the Society of Thoracic Surgeons (STS) risk score among transcatheter mitral edge-to-edge repair (TEER) patients. OBJECTIVE: Evaluate STS score accuracy, and the incremental value of post-procedural left atrial pressure (LAP). METHODS: A retrospective analysis of TEER patients between 2013 and 2020. Patients were allocated into 3 groups: high (≥8% [n = 298, 31%]), intermediate (4%-8% [n = 318, 33%]), and low (<4% [n = 344, 36%]). Primary outcomes included 1-year mortality or cardiovascular hospitalizations. Cox proportional hazards regression modeling was used to determine the hazard ratio of the primary outcome, and STS score accuracy was assessed by receiver operating characteristic. A spline curve was used to display the relationship between LAP and the primary endpoint. Continuous net reclassification improvement (NRI) was used to determine the incremental value of LAP. RESULTS: We included 960 patients, primarily elderly (79 [70-85]), with a median STS risk of 5.6 (3-9). High-risk patients were older (83 [75-89], 81 [74-87], 72 [64-79], p < 0.001), and had more comorbidities compared to intermediate and low-risk groups. Upon Cox regression, STS score (high vs. low: HR 2.5 [1.7-3.8]; Intermediate vs. low: HR 1.8 [1.2-2.7] and LAP HR 1.03 [1.01-1.06], p = 0.007) were associated with the outcome. C statistics analysis revealed low accuracy of the STS score (AUC-0.61 [0.58-0.65, p < 0.001]). Continuous NRI analysis indicated an improvement in risk prediction of 17% (6.9-26.2), p < 0.001. CONCLUSION: STS risk score has low accuracy in predicting clinical outcomes after TEER. Adding LAP measurements can improve reclassification and identify those prone to adverse outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cirurgiões , Humanos , Idoso , Implante de Prótese de Valva Cardíaca/efeitos adversos , Pressão Atrial , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Risco
4.
Int J Clin Pract ; 2023: 1977911, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36923520

RESUMO

Background: Limited data exist regarding the association between the quality of life (QoL) and clinical outcomes following transcatheter mitral valve repair (TMVr). We aimed to evaluate the prognostic significance of QoL assessment following TMVr and to characterize those who had procedural success, yet reported a low Kansas City Cardiomyopathy Questionnaire (KCCQ-12) score. Methods: We reported the experience of Cedars-Sinai Medical Center patients between 2013 and 2020. Patients were allocated into four groups according to the 30-day KCCQ: <25, 25-49, 50-74, and ≥75. Primary outcome included 1-year all-cause death or heart failure (HF) hospitalizations. We also examined the association between QoL and the primary outcome in those with procedural success. Results: A total of 555 patients were included in our analysis, median follow-up of 650 days (IQR 243-1113). The lower KCCQ groups had a higher prevalence of functional mitral regurgitation (65%, 60%, 56%, and 43%, p = 0.001), as well as a higher Society of Thoracic Surgeon (STS) score. These groups had a significantly higher occurrence of 1-year all-cause death or HF hospitalizations in a stepwise fashion (40%, 22%, 16%, and 10%, p < 0.001). Multivariable Cox regression analysis revealed 30-day KCCQ as the strongest predictor of the 1-year primary outcome (HR 0.98, 95%CI (0.97-0.99), p = 0.006). Approximately a quarter of patients with procedural success had a low KCCQ score. These patients had a higher rate of the combined 1-year outcome regardless of procedural success or failure. Conclusion: QoL following TMVr is a powerful prognostic factor. KCCQ assessment is an important indicator for identifying patients prone to adverse outcomes even after procedural success.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Qualidade de Vida , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Cateterismo Cardíaco/efeitos adversos
5.
JAMA ; 329(20): 1778-1788, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-37219553

RESUMO

Importance: There are limited data on the outcomes of transcatheter edge-to-edge mitral valve repair for degenerative mitral regurgitation (MR) in a real-world setting. Objective: To evaluate the outcomes of transcatheter mitral valve repair for degenerative MR. Design, Setting, and Participants: Cohort study of consecutive patients in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry who underwent nonemergent transcatheter mitral valve repair for degenerative MR in the US from 2014 through 2022. Exposure: Transcatheter edge-to-edge mitral valve repair with the MitraClip device (Abbott). Main Outcomes and Measures: The primary end point was MR success, defined as moderate or less residual MR and a mean mitral gradient of less than 10 mm Hg. Clinical outcomes were evaluated based on the degree of residual MR (mild or less MR or moderate MR) and mitral valve gradients (≤5 mm Hg or >5 to <10 mm Hg). Results: A total of 19 088 patients with isolated moderate to severe or severe degenerative MR who underwent transcatheter mitral valve repair were analyzed (median age, 82 years; 48% women; median Society of Thoracic Surgeons predicted risk of mortality with surgical mitral valve repair, 4.6%). MR success was achieved in 88.9% of patients. At 30 days, the incidence of death was 2.7%; stroke, 1.2%; and mitral valve reintervention, 0.97%. MR success compared with an unsuccessful procedure was associated with significantly lower mortality (14.0% vs 26.7%; adjusted hazard ratio, 0.49; 95% CI, 0.42-0.56; P < .001) and heart failure readmission (8.4% vs 16.9%; adjusted hazard ratio, 0.47; 95% CI, 0.41-0.54; P < .001) at 1 year. Among patients with MR success, the lowest mortality was observed in patients who had both mild or less residual MR and mean mitral gradients of 5 mm Hg or less compared with those with an unsuccessful procedure (11.4% vs 26.7%; adjusted hazard ratio, 0.40; 95% CI, 0.34-0.47; P < .001). Conclusions and Relevance: In this registry-based study of patients with degenerative MR undergoing transcatheter mitral valve repair, the procedure was safe and resulted in successful repair in 88.9% of patients. The lowest mortality was observed in patients with mild or less residual MR and low mitral gradients.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Mitral , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Procedimentos Cirúrgicos Cardíacos/métodos , Estudos de Coortes , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/cirurgia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Cateterismo Cardíaco , Sistema de Registros
6.
Circulation ; 143(23): 2229-2240, 2021 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-33619968

RESUMO

BACKGROUND: Stroke remains a devastating complication of transcatheter aortic valve replacement (TAVR), which has persisted despite refinements in technique and increased operator experience. While cerebral embolic protection devices (EPDs) have been developed to mitigate this risk, data regarding their impact on stroke and other outcomes after TAVR are limited. METHODS: We performed an observational study using data from the Society for Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Patients were included if they underwent elective or urgent transfemoral TAVR between January 2018 and December 2019. The primary outcome was in-hospital stroke. To adjust for confounding, the association between EPD use and clinical outcomes was evaluated using instrumental variable analysis, a technique designed to support causal inference from observational data, with site-level preference for EPD use within the same quarter of the procedure as the instrument. We also performed a propensity score-based secondary analysis using overlap weights. RESULTS: Our analytic sample included 123 186 patients from 599 sites. The use of EPD during TAVR increased over time, reaching 28% of sites and 13% of TAVR procedures by December 2019. There was wide variation in EPD use across hospitals, with 8% of sites performing >50% of TAVR procedures with an EPD and 72% performing no procedures with an EPD in the last quarter of 2019. In our primary analysis using the instrumental variable model, there was no association between EPD use and in-hospital stroke (adjusted relative risk, 0.90 [95% CI, 0.68-1.13]; absolute risk difference, -0.15% [95% CI, -0.49 to 0.20]). However, in our secondary analysis using the propensity score-based model, EPD use was associated with 18% lower odds of in-hospital stroke (adjusted odds ratio, 0.82 [95% CI, 0.69-0.97]; absolute risk difference, -0.28% [95% CI, -0.52 to -0.03]). Results were generally consistent across the secondary end points, as well as subgroup analyses. CONCLUSIONS: In this nationally representative observational study, we did not find an association between EPD use for TAVR and in-hospital stroke in our primary instrumental variable analysis, and found only a modestly lower risk of in-hospital stroke in our secondary propensity-weighted analysis. These findings provide a strong basis for large-scale randomized, controlled trials to test whether EPDs provide meaningful clinical benefit for patients undergoing TAVR.


Assuntos
Estenose da Valva Aórtica/cirurgia , Dispositivos de Proteção Embólica/efeitos adversos , Acidente Vascular Cerebral/patologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Razão de Chances , Pontuação de Propensão , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento
7.
Clin Infect Dis ; 75(4): 638-646, 2022 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34894124

RESUMO

BACKGROUND: Infective endocarditis (IE) following transcatheter aortic valve replacement (TAVR) has been associated with a dismal prognosis. However, scarce data exist on IE perivalvular extension (PEE) in such patients. METHODS: This multicenter study included 579 patients who had the diagnosis of definite IE at a median of 171 (53-421) days following TAVR. PEE was defined as the presence of an intracardiac abscess, pseudoaneurysm, or fistula. RESULTS: A total of 105 patients (18.1%) were diagnosed with PEE (perivalvular abscess, pseudoaneurysm, fistula, or a combination in 87, 7, 7, and 4 patients, respectively). A history of chronic kidney disease (adjusted odds ratio [ORadj], 2.08; 95% confidence interval [CI]: 1.27-3.41; P = .003) and IE secondary to coagulase-negative staphylococci (ORadj, 2.71; 95% CI: 1.57-4.69; P < .001) were associated with an increased risk of PEE. Surgery was performed at index IE episode in 34 patients (32.4%) with PEE (vs 15.2% in patients without PEE, P < .001). In-hospital and 2-year mortality rates among PEE-IE patients were 36.5% and 69.4%, respectively. Factors independently associated with an increased mortality were the occurrence of other complications (stroke post-TAVR, acute renal failure, septic shock) and the lack of surgery at index IE hospitalization (padj < 0.05 for all). CONCLUSIONS: PEE occurred in about one-fifth of IE post-TAVR patients, with the presence of coagulase-negative staphylococci and chronic kidney disease determining an increased risk. Patients with PEE-IE exhibited high early and late mortality rates, and surgery during IE hospitalization seemed to be associated with better outcomes.


Assuntos
Falso Aneurisma , Endocardite Bacteriana , Endocardite , Insuficiência Renal Crônica , Substituição da Valva Aórtica Transcateter , Abscesso , Falso Aneurisma/complicações , Falso Aneurisma/cirurgia , Coagulase , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Insuficiência Renal Crônica/complicações , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos
8.
Catheter Cardiovasc Interv ; 99(5): 1647-1658, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35019204

RESUMO

OBJECTIVES: To assess the impact of pulmonary hypertension (PH) on outcomes of patients with severe mitral annular calcification (MAC) undergoing transcatheter mitral valve replacement (TMVR). BACKGROUND: PH is associated with poor outcomes after mitral valve surgery. Whether the presence of PH in patients with MAC undergoing (TMVR) is associated with poor outcomes, is unknown. METHODS: Retrospective evaluation of 116 patients from 51 centers in 11 countries who underwent TMVR with valve in mitral annular calcification (ViMAC) using balloon-expandable aortic transcatheter valves (THVs) from September 2012 to March 2017. Pulmonary artery systolic blood pressure (PASP) by echocardiogram was available in 90 patients. The subjects were stratified based on PASP: No PH = PASP ≤35 mmHg (n = 11); mild to moderate PH = PASP 36-49 mmHg (n = 21) and severe PH = PASP ≥50 mmHg (n = 58). Clinical, procedural, and echocardiographic outcomes were assessed. RESULTS: Mean age was 72.7 (±12.8) years, 59 (65.6%) were female, Society of Thoracic Surgeons score was 15.8 + 11.8% and 90.0% where in New York Heart Association (NYHA) class III-IV. There was no significant difference in all-cause mortality at 30 days (no PH = 27.3%, mild-moderate PH = 19.0%, severe PH = 31.6%; p = 0.55) or at 1 year (no PH = 54.5%, mild-moderate PH = 38.1%, severe PH = 56.1%; p = 0.36). No difference in adverse events, NYHA class or amount of residual mitral regurgitation at 1 year were observed between the groups. CONCLUSION: This study suggests that the presence of PH in patients with predominantly mitral stenosis with MAC undergoing TMVR does not impact mortality or adverse events. Further studies are needed to fully understand the effect of PH in this group of patients.


Assuntos
Calcinose , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hipertensão Pulmonar , Insuficiência da Valva Mitral , Idoso , Calcinose/complicações , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Cateterismo Cardíaco/efeitos adversos , Feminino , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/cirurgia , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
9.
Clin Infect Dis ; 73(11): e3750-e3758, 2021 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-33733675

RESUMO

BACKGROUND: Procedural improvements combined with the contemporary clinical profile of patients undergoing transcatheter aortic valve replacement (TAVR) may have influenced the incidence and outcomes of infective endocarditis (IE) following TAVR. We aimed to determine the temporal trends, characteristics, and outcomes of IE post-TAVR. METHODS: Observational study including 552 patients presenting definite IE post-TAVR. Patients were divided in 2 groups according to the timing of TAVR (historical cohort [HC]: before 2014; contemporary cohort [CC]: after 2014). RESULTS: Overall incidence rates of IE were similar in both cohorts (CC vs HC: 5.45 vs 6.52 per 1000 person-years; P = .12), but the rate of early IE was lower in the CC (2.29‰ vs 4.89‰, P < .001). Enterococci were the most frequent microorganism. Most patients presented complicated IE ( CC: 67.7%; HC: 69.6%; P = .66), but the rate of surgical treatment remained low (CC: 20.7%; HC: 17.3%; P = .32). The CC exhibited lower rates of in-hospital acute kidney injury (35.1% vs 44.6%; P = .036) and in-hospital (26.6% vs 36.4%; P = .016) and 1-year (37.8% vs 53.5%; P < .001) mortality. Higher logistic EuroScore, Staphylococcus aureus etiology, and complications (stroke, heart failure, and acute renal failure) were associated with in-hospital mortality in multivariable analyses (P < .05 for all). CONCLUSIONS: Although overall IE incidence has remained stable, the incidence of early IE has declined in recent years. The microorganism, high rate of complications, and very low rate of surgical treatment remained similar. In-hospital and 1-year mortality rates were high but progressively decreased over time.


Assuntos
Endocardite Bacteriana , Endocardite , Substituição da Valva Aórtica Transcateter , Endocardite/epidemiologia , Endocardite/etiologia , Endocardite/cirurgia , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Humanos , Incidência , Complicações Pós-Operatórias/epidemiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
10.
Lancet ; 396(10252): 669-683, 2020 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-32593323

RESUMO

BACKGROUND: Randomised trial data assessing the safety and efficacy of the self-expanding intra-annular Portico transcatheter aortic valve system (Abbott Structural Heart, St Paul, MN, USA) compared with any commercially available valves are needed to compare performance among designs. METHODS: In this prospective, multicentre, non-inferiority, randomised controlled trial (the Portico Re-sheathable Transcatheter Aortic Valve System US Investigational Device Exemption trial [PORTICO IDE]), high and extreme risk patients with severe symptomatic aortic stenosis were recruited from 52 medical centres experienced in performing transcatheter aortic valve replacement in the USA and Australia. Patients were eligible if they were aged 21 years or older, in New York Heart Association functional class II or higher, and had severe native aortic stenosis. Eligible patients were randomly assigned (1:1) using permuted block randomisation (block sizes of 2 and 4) and stratified by clinical investigational site, surgical risk cohort, and vascular access method, to transcatheter aortic valve replacement with the first generation Portico valve and delivery system or a commercially available valve (either an intra-annular balloon-expandable Edwards-SAPIEN, SAPIEN XT, or SAPIEN 3 valve [Edwards LifeSciences, Irvine, CA, USA]; or a supra-annular self-expanding CoreValve, Evolut-R, or Evolut-PRO valve [Medtronic, Minneapolis, MN, USA]). Investigational site staff, implanting physician, and study participant were unmasked to treatment assignment. Core laboratories and clinical event assessors were masked to treatment allocation. The primary safety endpoint was a composite of all-cause mortality, disabling stroke, life-threatening bleeding requiring transfusion, acute kidney injury requiring dialysis, or major vascular complication at 30 days. The primary efficacy endpoint was all-cause mortality or disabling stroke at 1 year. Clinical outcomes and valve performance were assessed up to 2 years after the procedure. Primary analyses were by intention to treat and the Kaplan-Meier method to estimate event rates. The non-inferiority margin was 8·5% for primary safety and 8·0% for primary efficacy endpoints. This study is registered with ClinicalTrials.gov, NCT02000115, and is ongoing. FINDINGS: Between May 30 and Sept 12, 2014, and between Aug 21, 2015, and Oct 10, 2017, with recruitment paused for 11 months by the funder, we recruited 1034 patients, of whom 750 were eligible and randomly assigned to the Portico valve group (n=381) or commercially available valve group (n=369). Mean age was 83 years (SD 7) and 395 (52·7%) patients were female. For the primary safety endpoint at 30 days, the event rate was higher in the Portico valve group than in the commercial valve group (52 [13·8%] vs 35 [9·6%]; absolute difference 4·2, 95% CI -0·4 to 8·8 [upper confidence bound {UCB} 8·1%]; pnon-inferiority=0·034, psuperiority=0·071). At 1 year, the rates of the primary efficacy endpoint were similar between the groups (55 [14·8%] in the Portico group vs 48 [13·4%] in the commercial valve group; difference 1·5%, 95% CI -3·6 to 6·5 [UCB 5·7%]; pnon-inferiority=0·0058, psuperiority=0·50). At 2 years, rates of death (80 [22·3%] vs 70 [20·2%]; p=0·40) or disabling stroke (10 [3·1%] vs 16 [5·0%]; p=0·23) were similar between groups. INTERPRETATION: The Portico valve was associated with similar rates of death or disabling stroke at 2 years compared with commercial valves, but was associated with higher rates of the primary composite safety endpoint including death at 30 days. The first-generation Portico valve and delivery system did not offer advantages over other commercially available valves. FUNDING: Abbott.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Mortalidade , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Austrália , Transfusão de Sangue , Causas de Morte , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/terapia , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/terapia , Diálise Renal , Índice de Gravidade de Doença , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA