1.
J Magn Reson Imaging ; 56(6): 1863-1871, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35396789

RESUMO

BACKGROUND: Recently, a data-driven regression analysis method was developed to utilize the resting-state (rs) blood oxygenation level-dependent signal for cerebrovascular reactivity (CVR) mapping (rs-CVR), which was previously optimized by comparing with the CO2 inhalation-based method in health subjects and patients with neurovascular diseases. PURPOSE: To investigate the agreement of rs-CVR and the CVR mapping with breath-hold MRI (bh-CVR) in patients with gliomas. STUDY TYPE: Retrospective. POPULATION: Twenty-five patients (12 males, 13 females; mean age ± SD, 48 ± 13 years) with gliomas. FIELD STRENGTH/SEQUENCE: Dynamic T2*-weighted gradient-echo echo-planar imaging during a breath-hold paradigm and during the rs on a 3-T scanner. ASSESSMENT: rs-CVR with various frequency ranges and resting-state fluctuation amplitude (RSFA) were assessed. The agreement between each rs-based CVR measurement and bh-CVR was determined by voxel-wise correlation and Dice coefficient in the whole brain, gray matter, and the lesion region of interest (ROI). STATISTICAL TESTS: Voxel-wise Pearson correlation, Dice coefficient, Fisher Z-transformation, repeated-measure analysis of variance and post hoc test with Bonferroni correction, and nonparametric repeated-measure Friedman test and post hoc test with Bonferroni correction were used. Significance was set at P < 0.05. RESULTS: Compared with bh-CVR, the highest correlations were found at the frequency bands of 0.04-0.08 Hz and 0.02-0.04 Hz for rs-CVR in both whole brain and the lesion ROI. RSFA had significantly lower correlations than did rs-CVR of 0.02-0.04 Hz and a wider frequency range (0-0.1164 Hz). Significantly higher correlations and Dice coefficient were found in normal tissues than in the lesion ROI for all three methods. DATA CONCLUSION: The optimal frequency ranges for rs-CVR are determined by comparing with bh-CVR in patients with gliomas. The rs-CVR method outperformed the RSFA. Significantly higher correlation and Dice coefficient between rs- and bh-CVR were found in normal tissue than in the lesion. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Mapeamento Encefálico , Glioma , Masculino , Feminino , Humanos , Mapeamento Encefálico/métodos , Circulação Cerebrovascular , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Encéfalo/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Glioma/diagnóstico por imagem
2.
Magn Reson Med ; 71(3): 1166-71, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23776079

RESUMO

PURPOSE: Myelin content is a marker for nervous system pathology and is quantifiable by myelin water imaging using multi-echo CPMG sequence, which is inherently slow. One way to accelerate the scan is to utilize compressed sensing. However, reconstructing the images piecemeal by standard compressed sensing methods is not the optimal solution, because it only exploits intraimage spatial redundancy. It does not recognize that the different T2 weighted images are scans of the same anatomical volume and hence correlated. The purpose of this work is to test the feasibility of compressed sensed CPMG with group-sparsity promoting optimization for myelin water imaging. METHODS: Group-sparse reconstruction was performed at various simulated and actual undersampling factors for an electronic phantom, ex vivo rat spinal cord, and in vivo rat spinal cord. Normalized mean square error was used as the metric for comparison. RESULTS: For both simulated undersampling and the actual undersampling, the method was found to minimally impact myelin water fraction map quality (normalized mean square error < 0.25) when acceleration factor was below two. CONCLUSION: Compressed sensed CPMG with group-sparse reconstruction is useful for achieving a shorter scan time than traditionally possible.


Assuntos
Água Corporal/química , Compressão de Dados/métodos , Espectroscopia de Ressonância Magnética/métodos , Imagem Molecular/métodos , Bainha de Mielina/química , Medula Espinal/química , Algoritmos , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Acta Ophthalmol ; 102(5): e762-e773, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38279584

RESUMO

PURPOSE: To evaluate the structural, microvascular, and functional progression of normal tension glaucoma (NTG) with or without high myopia by examining longitudinal changes in optical coherence tomography angiography (OCTA) and visual field (VF) parameters. METHODS: We evaluated 61 NTG eyes and classified 25 of the eyes with axial lengths (ALs) of ≥26 mm as highly myopic. We assessed the rate of change in OCTA parameters, namely radial peripapillary capillary (RPC) vessel density (VD), parafovea VD, deep parafovea VD, retinal nerve fibre layer (RNFL) thickness, and ganglion cell complex thickness. We evaluated the correlation of the rate of change in OCTA parameters with VF loss and AL. RESULTS: Among the 61 NTG eyes, rates of loss of RPC VD, parafovea VD, deep parafovea VD, and RNFL thickness were significantly different from zero despite the nonsignificant rate of change in VF mean deviation (MD). Changes in these OCTA parameters did not differ significantly in highly myopic NTG eyes. The rate of change in VF MD was significantly correlated with the rate of change in parafovea VD in highly myopic and non-highly myopic NTG eyes. In highly myopic NTG eyes, AL was negatively correlated with the rates of loss of RNFL thickness, VF MD, and VF PSD. CONCLUSION: NTG eyes with a relatively stable VF exhibited loss of VD and RNFL thickness. VF progression in NTG was correlated with decreasing parafovea VD, indicating a structure-function correlation. Greater AL may indicate faster VF loss and RNFL thinning in highly myopic NTG eyes.


Assuntos
Angiofluoresceinografia , Pressão Intraocular , Glaucoma de Baixa Tensão , Fibras Nervosas , Disco Óptico , Células Ganglionares da Retina , Tomografia de Coerência Óptica , Campos Visuais , Humanos , Tomografia de Coerência Óptica/métodos , Glaucoma de Baixa Tensão/fisiopatologia , Glaucoma de Baixa Tensão/diagnóstico , Masculino , Feminino , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Angiofluoresceinografia/métodos , Células Ganglionares da Retina/patologia , Fibras Nervosas/patologia , Pressão Intraocular/fisiologia , Disco Óptico/irrigação sanguínea , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/patologia , Idoso , Seguimentos , Progressão da Doença , Miopia Degenerativa/fisiopatologia , Miopia Degenerativa/diagnóstico , Miopia Degenerativa/complicações , Estudos Retrospectivos , Fundo de Olho
4.
J Ophthalmol ; 2022: 1937431, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35378886

RESUMO

This retrospective cross-sectional study, which enrolled 124 normal tension glaucoma (NTG) eyes and 68 healthy eyes as the control, determined the association between central corneal thickness (CCT) and ocular parameters in NTG. CCT was measured using the Pentacam® system, optical coherence tomography angiography (OCT-A) was adopted to measure the peripapillary and macular area VDs, and spatial data were based on the Garway-Heath map as illustrated in OCT-A. Univariate and multivariate linear regressions were used to statistically analyze for associations between CCT and other factors. In this study, the mean age was similar for both the NTG and control groups. The mean CCT of the NTG group was significantly thinner than that of the control group (533.97 ± 33.11 µm vs. 546.78 ± 38.21 µm; p = .022). Considering all the factors, CCT negatively correlated with visual field (VF) pattern standard deviation (univariate, p = .045). To analyze structural and functional factors separately, we found a significant positive correlation between CCT and whole disc radial peripapillary capillary VD (VDRPC; multivariate, p = .019). To analyze the relationship between all factors and sectoral changes in VDRPC, a significant positive correlation was observed between CCT and inferior temporal VDRPC (univariate, p = .039) and inferior nasal VDRPC (VDRPC IN; univariate, p = .048). In conclusion, this novel study shows that among NTG participants, a thinner cornea correlated with weaker biomechanical properties susceptible to optic nerve tissue displacement, especially in response to mild transient elevation of IOP, leads to compromised ocular microcirculation.

5.
Diagnostics (Basel) ; 12(9)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36140574

RESUMO

This prospective study aimed to explore the effect of medical intraocular pressure (IOP) reduction on structural and capillary vessel density (VD) change by optical coherence tomography (OCT) angiography in early glaucoma. Patients with newly diagnosed glaucoma and a follow-up of ≥6 months were enrolled. An ocular examination that included slit-lamp bio-microscopy, pneumatic tonometry, gonioscopy, standard automated perimetry, and OCT angiography was performed. Quantitative OCT angiography parameters were assessed using a linear mixed model that was adjusted for inter-eye correlation. The correlations between IOP changes and OCT angiography parameter changes were analyzed using Spearman's correlation test. In total, 52 eyes of 36 participants, including 33 glaucoma eyes of 17 participants and 19 healthy eyes of 19 participants served as the case and control groups, respectively. The IOP of the case group decreased from a baseline mean of 20.4 ± 0.8 mmHg to 15.7 ± 0.5 mmHg at 3 months (p < 0.001) and to 16.1 ± 0.5 mmHg at 6 months (p < 0.001). For the subgroup with an IOP reduction of >20%, the deep macula VD was negatively correlated with baseline IOP and significantly decreased at 3 months follow-up. Additionally, change in retinal nerve fiber layer (RNFL) was positively correlated with a change in IOP at 6 months. In conclusion, the deep-layer macula VD was correlated with baseline IOP and influenced by the reduction in IOP in the short term. The changes in VD revealed the vulnerability of the deep vascular complex. The OCTA parameters provide in vivo monitoring information during medical treatment for early glaucoma.

6.
J Clin Sleep Med ; 18(1): 47-56, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34170230

RESUMO

STUDY OBJECTIVES: This study aimed to identify prospectively the correlation between obstructive sleep apnea (OSA) severity, ocular microcirculation changes, and visual function changes in patients with glaucoma. METHODS: We prospectively enrolled patients with glaucoma who were willing to undergo overnight polysomnography. The enrolled patients were further divided into normal tension glaucoma, high-tension glaucoma, and control. Visual field progression was analyzed using sequential standard automated perimetry. Peripapillary and macular vessel density were assessed through optical coherence tomography angiography (OCT-angiography). The associations between polysomnography parameters, OCT-angiography parameters, and visual field progression were analyzed. RESULTS: A total of 22 patients with normal tension glaucoma, 30 patients with high-tension glaucoma, and 24 control patients were enrolled. Through regression analysis, glaucoma was found to be an independent predictor of moderate-to-severe OSA (P = .035); furthermore, moderate-to-severe OSA was significantly associated with visual field progression (P = .008 in the high-tension glaucoma subgroup and P = .008 in the overall glaucoma). Additionally, OSA severity was negatively correlated with the ganglion cell complex thinning rate in the normal tension glaucoma subgroup. CONCLUSIONS: Presence of glaucoma increased the risk of moderate-to-severe OSA compared with the control group. OSA severity was related to visual field deterioration in patients with glaucoma and further associated with structural progression in the normal tension glaucoma subgroup. Careful monitoring of the comorbid OSA status of patients with glaucoma is essential to prevent disease progression. CITATION: Chan Y-H, Chuang L-H, Yu C-C, et al. Prospective evaluation of the comorbidity of obstructive sleep apnea in patients with glaucoma. J Clin Sleep Med. 2022;18(1):47-56.


Assuntos
Glaucoma , Glaucoma de Baixa Tensão , Apneia Obstrutiva do Sono , Comorbidade , Humanos , Glaucoma de Baixa Tensão/complicações , Glaucoma de Baixa Tensão/epidemiologia , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Testes de Campo Visual
7.
Med Phys ; 48(2): 640-647, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33283284

RESUMO

PURPOSE: Assessment of image quality directly in clinical image data is an important quality control objective as phantom-based testing does not fully represent image quality across patient variation. Computer algorithms for automatically measuring noise in clinical computed tomography (CT) images have been introduced, but the accuracy of these algorithms is unclear. This work benchmarks the accuracy of the global noise (GN) algorithm for automatic noise measurement in contrast-enhanced abdomen CT exams in comparison to precise reference noise measurements. The GN algorithm was further optimized compared to the previous report in the literature. METHODS: Reference values of noise were established in a public image dataset of 82 contrast-enhanced abdomen CT exams. The reference noise values were obtained by manual regions-of-interest measurements of pixel standard deviation in the liver parenchyma according to an instruction protocol. Noise measurements taken by six observers were averaged together to improve reference noise statistical precision. The GN algorithm was used to automatically measure noise in each image set. The accuracy of the GN algorithm was determined in terms of RMS error compared to reference noise. The GN algorithm was optimized by conducting 1000 trials with random algorithm parameter values. The trial with the lowest RMS error was used to select optimum algorithm parameters. RESULTS: The range of noise across CT image sets was 8.8-28.8 HU. Reference noise measurements were made with a precision of ±0.78 HU (95% confidence interval). The RMS error of automatic noise measurement was 0.93 HU (0.77-1.19 HU 95% confidence interval). The automatic noise measurements were equally accurate across image sets of varying noise magnitude. Optimum GN algorithm parameter values were: a kernel size of 7 pixels, and soft tissue lower and upper thresholds of 0 and 170 HU, respectively. CONCLUSIONS: The performance of automatic noise measurement was benchmarked in a large clinical CT dataset. The study provides a framework for thorough validation of automatic clinical image quality measurement methods. The GN algorithm was optimized and validated for automatic measurement of soft-tissue noise in abdomen CT exams.


Assuntos
Benchmarking , Processamento de Imagem Assistida por Computador , Algoritmos , Humanos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
8.
Neurosurgery ; 88(3): 544-551, 2021 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-33080024

RESUMO

BACKGROUND: Decline in neurocognitive functioning (NCF) often occurs following brain tumor resection. Functional connectomics have shown how neurologic insults disrupt cerebral networks underlying NCF, though studies involving patients with brain tumors are lacking. OBJECTIVE: To investigate the impact of brain tumor resection upon the connectome and relationships with NCF outcome in the early postoperative period. METHODS: A total of 15 right-handed adults with left perisylvian glioma underwent resting-state functional magnetic resonance imaging (rs-fMRI) and neuropsychological assessment before and after awake tumor resection. Graph theoretical analysis was applied to rs-fMRI connectivity matrices to calculate network properties. Network properties and NCF measures were compared across the pre- to postoperative periods with matched pairs Wilcoxon signed-rank tests. Associations between pre- to postoperative change in network and NCF measures were determined with Spearman rank-order correlations (ρ). RESULTS: A majority of the sample showed postoperative decline on 1 or more NCF measures. Significant postoperative NCF decline was found across measures of verbal memory, processing speed, executive functioning, receptive language, and a composite index. Regarding connectomic properties, betweenness centrality and assortativity were significantly smaller postoperatively, and reductions in these measures were associated with better NCF outcomes. Significant inverse associations (ρ = -.51 to -.78, all P < .05) were observed between change in language, executive functioning, and learning and memory, and alterations in segregation, centrality, and resilience network properties. CONCLUSION: Decline in NCF was common shortly following resection of glioma involving eloquent brain regions, most frequently in verbal learning/memory and executive functioning. Better postoperative outcomes accompanied reductions in centrality and resilience connectomic measures.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Cognição/fisiologia , Conectoma/tendências , Glioma/diagnóstico por imagem , Testes de Estado Mental e Demência , Adulto , Neoplasias Encefálicas/psicologia , Neoplasias Encefálicas/cirurgia , Craniotomia/psicologia , Craniotomia/tendências , Função Executiva/fisiologia , Feminino , Glioma/psicologia , Glioma/cirurgia , Humanos , Imageamento por Ressonância Magnética/tendências , Masculino , Memória/fisiologia , Pessoa de Meia-Idade , Rede Nervosa/diagnóstico por imagem , Rede Nervosa/fisiologia , Estudos Prospectivos
9.
Magn Reson Med ; 63(2): 473-83, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20099327

RESUMO

Passive MRI is a promising approach to visualize catheters in guiding and monitoring endovascular intervention and may offer several clinical advantages over the current x-ray fluoroscopy "gold standard." Endovascular MRI has limitations, however, such as difficulty in visualizing catheters and insufficient temporal resolution. The multicycle projection dephaser method is a background signal suppression technique that improves the conspicuity of passive catheters by generating a sparse (i.e., catheter only) image. One approach to improve the temporal resolution is to undersample the k-space and then apply nonlinear methods, such as compressed sensing, to reconstruct the MR images. This feasibility study investigates the potential synergies between multicycle projection dephaser and compressed sensing reconstruction for real-time passive catheter tracking. The multicycle projection dephaser method efficiently suppressed the background signal, and compressed sensing allowed MR images to be reconstructed with superior catheter conspicuity and spatial resolution when compared to the more conventional zero-filling reconstruction approach. Moreover, compressed sensing allowed the shortening of total acquisition time (by up to 32 times) by vastly undersampling the k-space while simultaneously preserving spatial resolution and catheter conspicuity.


Assuntos
Artérias/anatomia & histologia , Cateterismo Periférico/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Animais , Simulação por Computador , Cães , Estudos de Viabilidade
10.
PLoS One ; 15(8): e0237796, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32804983

RESUMO

PURPOSE: To characterize changes in the retinal nerve fiber layer (RNFL) and peripapillary vessel density (VD) at the site of disc hemorrhage (DH) in nonglaucomatous eyes. MATERIALS AND METHODS: This retrospective cross-sectional study included nonglaucomatous eyes diagnosed with unilateral DH. The change of DH was recorded using disc photography. Both anatomical data and functional visual field (VF) data were collected using optical coherence tomography angiography and Humphrey VF examination. RESULTS: Sixteen patients were included with average follow-up duration of 95 months. Almost half of DH episodes was initially presented at the inferotemporal area of the optic disc. Pigment formation at the previous DH site after resolution was noted in 12.5% of eyes. Sectoral radial peripapillary VD at the DH site was significantly lower in DH eyes than in the control group; however, the sectoral RNFL thickness at the DH site was not significantly decreased. Progression of the VF defect corresponding to the DH site was found in 81.3% of eyes despite regular use of antiglaucoma agents. The mean change in the VF mean deviation was -0.64 dB/year in DH eyes. CONCLUSION: During long follow-up periods, decreased peripapillary VD at the DH site and progression of the VF defect corresponding to the DH site were detected in nonglaucomatous eyes. Retinal pigmentation with an RNFL defect is a clue for DH, although RNFL showed no significant change. Antiglaucoma treatment may not prevent the deterioration of visual function.


Assuntos
Doenças do Nervo Óptico/complicações , Hemorragia Retiniana/complicações , Vasos Retinianos/patologia , Transtornos da Visão/etiologia , Idoso , Estudos Transversais , Progressão da Doença , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Disco Óptico/diagnóstico por imagem , Disco Óptico/fisiopatologia , Doenças do Nervo Óptico/diagnóstico , Doenças do Nervo Óptico/fisiopatologia , Retina/diagnóstico por imagem , Retina/patologia , Hemorragia Retiniana/diagnóstico , Hemorragia Retiniana/fisiopatologia , Vasos Retinianos/diagnóstico por imagem , Estudos Retrospectivos , Tomografia de Coerência Óptica , Transtornos da Visão/diagnóstico , Transtornos da Visão/fisiopatologia , Testes de Campo Visual/estatística & dados numéricos , Campos Visuais/fisiologia
11.
Medicine (Baltimore) ; 99(13): e19468, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32221069

RESUMO

This study characterized and evaluated normal tension glaucoma (NTG) in obstructive sleep apnea syndrome (OSAS).In this retrospective, cross-sectional study, all participants were examined with polysomnography (PSG). Functional parameters of standard automated perimetry (SAP) were recorded. Structural parameters in optical coherence tomography angiography (OCTA) included peripapillary superficial vessel density (VD RPC), peripapillary whole-layer (VD NH), and superficial and deep macular area VD. Participants were categorized into perimetric and nonperimetric groups by SAP result. Low reliability of SAP and signal strength index <50 in OCTA were excluded.Severity of OSAS was graded by apnea-hypopnea index (AHI) in PSG. Those with moderate/severe OSAS (AHI ≥ 15, n = 39) had longer neck circumference and shorter ocular axial length than mild OSAS (AHI < 15, n = 14). Furthermore, there was significantly higher AHI and larger neck circumference in the NTG perimetric group (n = 27) than in the control group (n = 26; p < 0.001 and p = 0.047, respectively). Superficial and deep-layer peripapillary and macular area VD significantly decreased in the perimetric group. Overall, structural and functional parameters show that VF PSD was negatively correlated with VD NH and VD RPC (p = 0.007, p = 0.015); and VF MD was positively correlated with VD NH (p = 0.029), but not significantly to VD RPC (p = 0.106).OSAS is a risk factor of NTG. With aid of OCTA, whole-layer retinal capillary dropout supports that the vascular dysregulation of OSAS leads to NTG.


Assuntos
Glaucoma de Baixa Tensão/epidemiologia , Apneia Obstrutiva do Sono/epidemiologia , Adulto , Idoso , Pesos e Medidas Corporais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores Socioeconômicos , Tomografia de Coerência Óptica , Testes de Campo Visual
12.
Ophthalmic Surg Lasers Imaging ; 34(4): 291-8, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12875457

RESUMO

BACKGROUND AND OBJECTIVE: To assess the long-term results of Nd:YAG laser iridotomy in the treatment of patients with primary angle-closure glaucoma and occludable angles to evaluate the risk-benefit ratio and the role of gonioscopy in predicting the outcome after Nd:YAG laser iridotomy. PATIENTS AND METHODS: The records of 138 consecutive patients (231 eyes) who underwent Nd:YAG laser iridotomy in one hospital during 3 years (from 1989 to 1991) were reviewed. The mean follow-up period was 51 months. RESULTS: Of all eyes, 25.1% were treated for chronic angle-closure glaucoma and 10.8% were treated for acute angle-closure glaucoma; most eyes (64.1%) underwent prophylactic iridotomy for occludable angles. Decreased intraocular pressure (IOP) was noted in most eyes after Nd:YAG laser iridotomy; only 10 eyes required further filtration surgery. Visual acuity was unchanged or improved in 97.9% of all eyes at the 6-month visit. Cataract progression was primarily responsible for those eyes with decreased acuity. Ninety-seven percent of eyes had quantitatively wider angles after laser treatment; 8 of 14 eyes with peripheral anterior synechiae of more than 270 degrees underwent further surgery to control IOP. Transient elevated IOP and iris bleeding occurred in 23.5% and 12.2% of the eyes, respectively; other complications were rare. CONCLUSION: Nd:YAG laser iridotomy is a safe and effective procedure for the treatment and prevention of angle-closure glaucoma. Gonioscopy is useful to predict the outcome after Nd:YAG laser iridotomy.


Assuntos
Povo Asiático , Glaucoma de Ângulo Fechado/cirurgia , Iris/cirurgia , Terapia a Laser , Adulto , Idoso , Idoso de 80 Anos ou mais , Etnicidade , Feminino , Cirurgia Filtrante , Seguimentos , Glaucoma de Ângulo Fechado/patologia , Glaucoma de Ângulo Fechado/fisiopatologia , Glaucoma de Ângulo Fechado/prevenção & controle , Gonioscopia , Humanos , Pressão Intraocular , Terapia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Período Pós-Operatório , Medicina Preventiva/métodos , Prognóstico , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual
13.
J Magn Reson Imaging ; 29(6): 1262-70, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19472379

RESUMO

PURPOSE: To develop an appropriate method to evaluate the time-course of diffusion and perfusion changes in a clinically relevant animal model of ischemic stroke and to examine lesion progression on MR images. An exploration of acute stroke infarct expansion was performed in this study by using a new methodology for developing time-to-infarct maps based on the time at which each voxel becomes infarcted. This enabled definition of homogeneous regions from the heterogeneous stroke infarct. MATERIALS AND METHODS: Time-to-infarct maps were developed based on apparent diffusion coefficient (ADC) changes. These maps were validated and then applied to blood flow and time-to-peak maps to examine perfusion changes. RESULTS: ADC stroke infarct showed different evolution patterns depending on the time at which that region of tissue infarcted. Applying the time-to-infarct maps to the perfusion maps showed localized perfusion evolution characteristics. In some regions, perfusion was immediately affected and showed little change over the experiment; however, in some regions perfusion changes were more dynamic. CONCLUSION: Results were consistent with the diffusion-perfusion mismatch hypothesis. In addition, characteristics of collateral recruitment were identified, which has interesting stroke pathophysiology and treatment implications.


Assuntos
Mapeamento Encefálico/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Acidente Vascular Cerebral/patologia , Animais , Circulação Cerebrovascular , Meios de Contraste , Modelos Animais de Doenças , Progressão da Doença , Cães , Gadolínio DTPA , Processamento de Imagem Assistida por Computador , Fatores de Tempo