Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 445-453, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38270291

RESUMO

PURPOSE: This study aimed to compare long-term clinical and radiographic outcomes and survival rates between navigation-assisted (NAV) total knee arthroplasty (TKA) and conventional (CON) TKA using a mobile-bearing insert. METHODS: From May 2008 to December 2009, 45 and 63 mobile-bearing TKA patients were enroled in the CON- and NAV-TKA groups with 146.8 months follow-up, respectively. Clinical outcomes (Western Ontario and McMaster University Osteoarthritis Index and Knee Society Scores), radiographic outcomes (hip-knee-ankle [HKA], lateral distal femoral, medial proximal tibial, γ, and δ angles), and survivorship were compared between both groups. RESULTS: The number of HKA angle outliers (more than 3 degrees or less than -3 degree) was significantly lower in the NAV-TKA group (24.4% vs. 9.5%, p = 0.036) than in the CON-TKA group. However, long-term clinical outcomes were similar between both groups. The cumulative survival rate (best-case scenario) was 98.3% in the CON-TKA group and 97.5% in the NAV-TKA group, with no significant difference between the groups (p = 0.883). CONCLUSION: Long-term clinical outcomes and survival rates were similar between the two groups despite fewer outliers of postoperative lower-limb alignment in the NAV-TKA group. Excellent survival rates were observed in both groups using mobile-bearing inserts. LEVEL OF EVIDENCE: Level IV, case series.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Cirurgia Assistida por Computador , Humanos , Taxa de Sobrevida , Seguimentos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos
2.
Medicina (Kaunas) ; 60(5)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38792971

RESUMO

Background and Objectives: Patella baja is a common complication after operative treatment for patellar fracture. This study aimed to investigate (1) the serial changes in patellar height and (2) the potential predictive factors for patellar height changes after tension band wiring (TBW) for patellar fractures. Materials and Methods: Forty-one patients who underwent TBW for patellar fracture between March 2019 and September 2022 were enrolled. To identify serial changes in patellar height, modified Blackburne-Peel index (mBPI) was assessed at just after surgery, at 3 months, at 6 months, at 1 year and at the final follow-up. Multiple regression analysis was conducted to identify factors correlated with mBPI difference between the contralateral side (considered as preoperative status) and injured side. Results: The postoperative mBPI exhibited a decline over time (mean mBPI immediately post operation/3 months/6 months/1 year/final follow-up: 0.69/0.63/0.63/0.62/0.61) Specifically, mBPI showed a significant reduction immediately post operation to 3 months (p < 0.001), although comparisons at other time points did not reveal significant differences. A lower position of the fracture was associated with a decrease in patellar height after surgery. Conclusions: Patellar height was mainly decreased from immediately post operation to 3 months. A fracture in a lower position of associated with decreased patellar height after the TBW of the transverse patellar fracture.


Assuntos
Fraturas Ósseas , Patela , Humanos , Patela/lesões , Masculino , Feminino , Adulto , Fraturas Ósseas/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Fios Ortopédicos/efeitos adversos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/efeitos adversos
3.
J Hand Surg Am ; 48(1): 85.e1-85.e10, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-34839963

RESUMO

PURPOSE: Local steroid injection is an effective treatment modality for carpal tunnel syndrome. This study aimed to investigate the success rate of ultrasonography-guided local steroid injection and determine the prognostic value of the cross-sectional area (CSA) of the median nerve for steroid injection. METHODS: We retrospectively evaluated 40 patients with carpal tunnel syndrome whose median nerve CSA was >15 mm2 (large-CSA group; n = 16) or ≤15 mm2 (small-CSA group; n = 24). The CSA was measured using ultrasonography, and all the patients were treated with ultrasonography-guided corticosteroid injection. Demographic characteristics, symptoms, initial QuickDASH score, Boston Carpal Tunnel Questionnaires, and results of the nerve conduction study were assessed at baseline. Treatment success was defined in this study as the absence of symptom recurrence within the entire follow-up period. RESULTS: The treatment success rate was 45% (n = 18) after an average follow-up of 16 months. Overall, 11 patients (28%) underwent carpal tunnel release on an average of 11 months after steroid injection. The large-CSA group showed a significantly worse grade of electrodiagnostic testing at baseline than did the small-CSA group; however, there was no significant difference in final Boston Carpal Tunnel Questionnaires symptom score (1.7 vs 1.8, respectively) and the rate of continued treatment success at the last follow-up (42% vs 50%, respectively). The proportions of patients who required carpal tunnel decompression were 29% and 25% in the small-CSA and large-CSA groups, respectively. CONCLUSIONS: Local steroid injection for carpal tunnel syndrome has an overall success rate of 45% after a mean follow-up of 16 months. Preinjection CSA was not associated with whether the steroid injection was considered successful. This indicates that increased median nerve CSA does not preclude the possibility of symptomatic relief after a local steroid injection. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.


Assuntos
Síndrome do Túnel Carpal , Nervo Mediano , Humanos , Nervo Mediano/diagnóstico por imagem , Nervo Mediano/cirurgia , Síndrome do Túnel Carpal/diagnóstico por imagem , Síndrome do Túnel Carpal/tratamento farmacológico , Síndrome do Túnel Carpal/cirurgia , Prognóstico , Estudos Retrospectivos , Ultrassonografia , Esteroides/uso terapêutico
4.
J Hand Ther ; 35(4): 641-644, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34253401

RESUMO

INTRODUCTION: Lateral epicondylitis is a common tendinopathy of the elbow. An adequately validated questionnaire is essential to compare the various treatment options, because there is still controversy regarding the best treatment for lateral epicondylitis. PURPOSE OF THE STUDY: The patient-rated tennis elbow evaluation (PRTEE) was introduced to measure the degree of symptoms and the limitation of function in these patients. This English questionnaire was previously translated into several languages and validated; however, it has not been translated into Korean. The aim of this study was to translate and cross-culturally adapt the PRTEE questionnaire into Korean, and to assess the reliability and validity of the translated questionnaire. METHODS: Eighty-three patients were asked to complete the Korean version of the PRTEE and other questionnaires related to the upper extremity or to the general health condition (the Disabilities of Arm, Shoulder, and Hand questionnaire, Short Form-12, and EQ-5D). The PRTEE responses were recorded twice to evaluate test-retest reliability. Internal consistency, test-retest reliability, concurrent validity, and ceiling and flooring effects were evaluated. RESULTS: The Korean version of the PRTEE showed high internal consistency (Cronbach's alpha = 0.968). The overall test-retest reliability was good (intra-class correlation score = 0.94). High correlation efficiencies between the PRTEE and other questionnaires were observed, supporting high concurrent validity (Spearman's correlation = 0.83 for the Disabilities of Arm, Shoulder, and Hand questionnaire; -0.73 for Short Form-12; and -0.57 for EQ-5D). Ceiling and floor effects were not observed on this test. CONCLUSION: We successfully translated the PRTEE into the Korean language; this version of the PRTEE showed good reliability and construct validity in Korean-speaking patients with lateral epicondylitis.


Assuntos
Cotovelo de Tenista , Humanos , Cotovelo de Tenista/terapia , Reprodutibilidade dos Testes , Avaliação da Deficiência , Inquéritos e Questionários , Idioma , República da Coreia , Psicometria
5.
Medicina (Kaunas) ; 58(9)2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36143888

RESUMO

Background and Objectives: The tibial component alignment is an important issue for the longevity of total knee arthroplasty (TKA). The purpose of our study was to investigate the usefulness of proximal tibial references determined by pre-operative radiography and intraoperative C-arm-guided hip and ankle center marking for the extramedullary guided tibial cut in mild (<10°) and severe (≥10°) varus knee TKA. Materials and Methods: A total of 150 consecutive patients (220 cases) who underwent total knee arthroplasty who were recruited from July 2011 to April 2017 were reviewed retrospectively. Before surgery, the proximal tibial reference point and medio-lateral cut thickness difference were identified. Then, hip and ankle centers were checked using a C-arm intensifier intraoperatively. The hip−knee−ankle (HKA) alignment and medial proximal tibial angle (MPTA) were assessed pre-operatively and post-operatively. More than 3° varus or valgus of HKA alignment or tibial component angle was defined as an outlier. Results: Mean follow-up duration was 26.9 months. Among 220 cases, 111 cases are classified as mild varus group and 109 cases are classified as severe varus group. The HKA alignment is significantly improved (p < 0.001). The average tibial component angle after surgery is 90.1°. A total of 21 cases (9.5%) and 3 cases (1.4%) are classified as outliers of HKA alignment and MPTA, respectively. Among MPTA outliers, one case is in the mild varus group and two cases are in the in severe varus group (p = 0.62). Conclusion: Measurement of proximal tibial radiographic references and checking the C-arm-guided intraoperative hip and ankle center could be helpful to obtain the favorable coronal position of the tibial component in the extramedullary guided tibial cut.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Humanos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/cirurgia , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
6.
Medicina (Kaunas) ; 58(12)2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36556989

RESUMO

Background and Objectives: A reduction forced toward the posterior side during graft fixation may help to lessen anterior tibial translation after ACL reconstruction. The purpose was to compare the clinical and radiological outcomes of graft fixation when a posterior draw was used and when it was not used during anterior cruciate ligament (ACL) reconstruction surgery. Materials and Methods: Of 110 patients who had undergone primary arthroscopic ACL reconstruction between January 2017 and August 2020, in all, 76 patients had been operated on without a posterior draw (non-draw group), and 34 patients had received surgery with a posterior draw (draw group). The results of the Lachman test and the pivot-shift test, the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) indexes, the Lysholm scores, the International Knee Documentation Committee (IKDC) subjective scores, and side-to-side difference (STSD) on stress radiography were compared between the two groups. Results: The postoperative WOMAC indexes, Lysholm scores, and IKDC subjective scores were similar across both groups. Postoperative STSD (2.4 ± 2.2 for the non-draw group vs. 2.0 ± 2.2 for the draw group; p = 0.319) and change in STSD (3.5 ± 3.5 for preoperative STSD vs. 4.3 ± 4.4 for postoperative STSD; p = 0.295) were not superior in the draw group. Conclusions: The take-home message is that graft fixation with a posterior draw during ACL reconstruction did not result in significantly better postoperative stability. The postoperative clinical outcomes were similar between both groups.


Assuntos
Lesões do Ligamento Cruzado Anterior , Reconstrução do Ligamento Cruzado Anterior , Humanos , Resultado do Tratamento , Lesões do Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Reconstrução do Ligamento Cruzado Anterior/métodos , Tíbia/cirurgia
7.
Sensors (Basel) ; 21(8)2021 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-33923716

RESUMO

In this study, we developed a new type of wireless transmission system for use in partially implantable hearing aids. This system was designed for miniaturization and low distortion, and features direct digital modulation. The sigma-delta output, which has a high SNR due to oversampling and noise shaping technology, is used as the data signal and is transmitted using a wireless transmission system to the implant unit through OOK without restoration as an audio signal, thus eliminating the need for additional circuits (i.e., LPF and a reference voltage supply circuit) and improving the ease of implantation and reliability of the circuit. We selected a carrier frequency of 27 MHz after analysis of carrier attenuation by human tissue, and designed the communication coil with reference to both the geometry and required communication distance. Circuit design and simulation for wireless transmission were performed using Multisim 13.0. The system was fabricated based on the circuit design; the size of the device board was 13 mm × 13 mm, the size of the implanted part was 9 mm × 9 mm, the diameter of the transmitting/receiving coil was 26 mm, and the thicknesses of these coils were 0.5 and 0.3 mm, respectively. The difference (error) between the detected and simulation waveforms was about 5%, and was thought to be due to the tolerances of the fabricated communication coil and elements (resistors, capacitors, etc.) used in the circuit configuration of the system. The number of windings was reduced more than 9-fold compared to the communication coil described by Taghavi et al. The measured THD was <1% in the frequency band from 100 Hz to 10 kHz, thus easily meeting the standard specification for hearing aids.


Assuntos
Auxiliares de Audição , Desenho de Equipamento , Humanos , Miniaturização , Próteses e Implantes , Reprodutibilidade dos Testes , Tecnologia sem Fio
8.
Int Orthop ; 45(12): 3101-3110, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34379159

RESUMO

PURPOSE: To correct hallux valgus deformities in patients with a greater pronation of the first metatarsal, we designed a novel proximal triple derotational metatarsal osteotomy (PTDMO), which could be used to achieve three-dimensional correction of hallux valgus deformities at the proximal metatarsal level. METHODS: We prospectively evaluated the radiographic and clinical outcomes of 13 consecutive cases underwent PTDMO between November 2018 and May 2020. The minimum follow-up for inclusion was 12 months. The hallux valgus angle (HVA), first-to-second intermetatarsal angle (IMA), distal metatarsal articular angle (DMAA), relative length of the second metatarsal, and medial sesamoid position on the weight bearing foot anteroposterior radiographs, and the degree of the first metatarsal pronation on forefoot axial radiographs were measured pre-operatively, at six weeks post-operatively, and at the final follow-up. The American Orthopaedic Foot and Ankle Society (AOFAS) score and Foot Ankle Outcome Scores (FAOS) were measured. RESULTS: In the comparison of pre-operative and final follow-up parameters, HVA, IMA, and DMAA were significantly improved post-operatively (all, P < 0.001). The relative length of the second metatarsal did not differ significantly post-operatively (P = 0.724). The medial sesamoid was significantly reduced (P = 0.01), and the first metatarsal pronation decreased by 10.16° (P = 0.034). Regarding clinical parameters, the AOFAS score and FAOS in all categories significantly improved post-operatively (all, P < 0.001). CONCLUSION: PTDMO resulted in satisfactory radiographic and clinical outcomes with respect to deformity correction and pain relief, with significant post-operative reduced pronation of the first metatarsal.


Assuntos
Hallux Valgus , Ossos do Metatarso , Articulação Metatarsofalângica , Hallux Valgus/diagnóstico por imagem , Hallux Valgus/cirurgia , Humanos , Ossos do Metatarso/diagnóstico por imagem , Ossos do Metatarso/cirurgia , Articulação Metatarsofalângica/diagnóstico por imagem , Articulação Metatarsofalângica/cirurgia , Osteotomia , Resultado do Tratamento
9.
Molecules ; 26(4)2021 Feb 04.
Artigo em Inglês | MEDLINE | ID: mdl-33557189

RESUMO

The physical and mechanical properties of nitrile-butadiene rubber (NBR) composites with N-cetylpyridinium bromide-carbon black (CPB-CB) were investigated. Addition of 5 parts per hundred rubber (phr) of CPB-CB into NBR improved the tensile strength by 124%, vulcanization rate by 41%, shore hardness by 15%, and decreased the volumetric wear by 7% compared to those of the base rubber-CB composite.


Assuntos
Butadienos/química , Cetilpiridínio/química , Fenômenos Mecânicos , Nitrilas/química , Fenômenos Físicos , Borracha/química , Fuligem/química
10.
Sensors (Basel) ; 19(5)2019 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-30841613

RESUMO

To develop totally implantable middle ear and cochlear implants, a miniature microphone that is surgically easy to implant and has a high sensitivity in a sufficient range of audio frequencies is needed. Of the various implantable acoustic sensors under development, only micro electro-mechanical system-type acoustic sensors, which attach to the umbo of the tympanic membrane, meet these requirements. We describe a new vibro-acoustic hybrid implantable microphone (VAHIM) that combines acceleration and sound pressure sensors. Each sensor can collect the vibration of the umbo and sound pressure of the middle ear cavity. The fabricated sensor was implanted into a human temporal bone and the noise level and sensitivity were measured. From the experimental results, it is shown that the proposed method is able to provide a wider-frequency band than conventional implantable acoustic sensors.


Assuntos
Técnicas Biossensoriais , Implantes Cocleares , Auxiliares de Audição , Humanos , Desenho de Prótese
11.
Molecules ; 24(2)2019 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-30634465

RESUMO

Mixtures of layered silicates (vermiculite and kaolinite) and carbon fibers were investigated as filler materials for polytetrafluoroethylene. The supramolecular structure and the tribological and mechanical properties of the resulting polymer composite materials were evaluated. The yield strength and compressive strength of the polymer increased by 55% and 60%, respectively, when a mixed filler was used, which was attributed to supramolecular reinforcement of the composites. In addition, the wear resistance increased by 850 times when using vermiculite/kaolinite fillers, which was due to protection of the surface by the formation of hard tribofilms.


Assuntos
Fibra de Carbono/química , Politetrafluoretileno/química , Silicatos/química , Silicatos de Alumínio/química , Força Compressiva , Dureza , Caulim/química , Teste de Materiais
12.
Trop Anim Health Prod ; 51(2): 443-448, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30238226

RESUMO

The effects of corn particle size on nutrient digestibility and energy utilization in pigs were determined under optimal (experiment 1, 25 ± 1 °C) or heat stress (experiment 2, 37 ± 1 °C) conditions. In Exp. 1 and 2, five experimental diets were tested using a 5 × 5 Latin square design involving five barrows (Landrace × Yorkshire × Duroc, average initial body weight of 30 ± 1 kg and 45.0 ± 1.8 kg, respectively, in individual metabolic cages). Dietary treatments were as follows: 200-, 300-, 400-, 600-, 800-µm corn particle sizes obtained by mesh screens. Under optimal thermal conditions, digestibility of dry matter (DM) and crude fiber (CF) from 200-µm diet was higher (P < 0.05) compared to that from the 300-µm and 400-µm diets. The digestibility of crude protein (CP) and ether extract (EE) was the highest (P < 0.05) at the 200-µm particle size. The apparent total tract digestibility of energy was significantly higher (P < 0.05) on the 200-µm diet. Under heat stress, digestibility of CF when corn was ground to 600 µm was higher (P < 0.05) compared to 300 and 400 µm. Digestibility of NDF and ADF was the highest (P < 0.05) at 600-µm corn particle size. In conclusion, grinding corn to 200-µm corn particles had a positive effect on DM, CP, EE, and CF under optimal thermal condition, while the 600-µm corn particle size had positive effects on digestibility of CF, NDF, and ADF than 200-µm corn particle size under heat stress.


Assuntos
Ração Animal , Digestão , Tamanho da Partícula , Suínos , Zea mays , Fenômenos Fisiológicos da Nutrição Animal , Animais , Dieta/veterinária , Resposta ao Choque Térmico , Nutrientes
13.
Sensors (Basel) ; 18(6)2018 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-29795018

RESUMO

The design and implementation of a novel piezoelectric-based actuator for an implantable middle-ear hearing aid is described in this paper. The proposed actuator has excellent low-frequency output characteristics, and can generate high output in a specific frequency band by adjusting the mechanical resonance. The actuator consists of a piezoelectric element, a miniature bellows, a cantilever membrane, a metal ring support, a ceramic tip, and titanium housing. The optimal structure of the cantilever-membrane design, which determines the frequency characteristics of the piezoelectric actuator, was derived through finite element analysis. Based on the results, the piezoelectric actuator was implemented, and its performance was verified through a cadaveric experiment. It was confirmed that the proposed actuator provides better performance than currently used actuators, in terms of frequency characteristics.


Assuntos
Auxiliares de Audição , Prótese Ossicular , Cadáver , Análise de Elementos Finitos , Humanos , Osso Temporal/fisiopatologia , Titânio/química , Titânio/uso terapêutico , Vibração
14.
Molecules ; 23(9)2018 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-30150557

RESUMO

Sealing rubbers employed in cold climates such as the Siberian Arctic must be able to withstand temperatures as low as -50 °C while still exhibiting specific relaxation, strength, tribological characteristics, and a resistance to aggressive media. Previous investigations of propylene oxide rubber (SKPO, Tg = -73 °C) modified with polytetrafluoroethylene (PTFE) have revealed that, while the rubber composite materials exhibit double the wear resistance compared to unmodified polypropylene oxide rubber, they have poor frost resistance. In the present study, we developed materials based on SKPO and ultrafine PTFE (UPTFE), which can be characterized by its smaller particle size, low molecular weight, high tribo-technical characteristics, and resistance to aggressive media. The properties of the rubber composites were evaluated using the standard methods. The structures of the materials were investigated by electron microscopy and XRD analysis. It was shown that the materials have excellent wear resistance, resistance to aggressive media, compression set, and low-temperature resistance. The addition of UPTFE is preferable to the addition of PTFE because the desired positive effects can be attained with only 0.5⁻1 parts per hundred parts of rubber (phr) UPTFE while 20 phr PTFE would be necessary.


Assuntos
Compostos de Epóxi/química , Compostos de Epóxi/isolamento & purificação , Borracha/química , Teste de Materiais , Fenômenos Mecânicos , Difração de Raios X
15.
Molecules ; 22(12)2017 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-29206140

RESUMO

In this study, the reinforcement of ultrahigh-molecular-weight polyethylene (UHMWPE) with biotite was investigated. The biotite filler was mechanically activated with different dry surfactants to improve its compatibility with UHMWPE and decrease agglomeration among biotite particles. Alkyldimethylbenzylammonium chloride (ADBAC) and cetyltrimethylammonium bromide (CTAB) were selected as cationic surfactants. The tensile strength of composites containing 1 wt % of CTAB-treated biotite was increased by 30% relative to those with untreated biotite, but was unchanged with ADBAC treatment of the same biotite content. The stereochemistry of the surfactant may be critical to the composite structure and mechanical properties of the material. The stereochemistry of CTAB was preferable to that of ADBAC in enhancing mechanical properties because the stereochemistry of ADBAC impedes favorable interactions with the biotite surface during mechanical activation.


Assuntos
Silicatos de Alumínio/química , Compostos de Benzalcônio/química , Compostos de Cetrimônio/química , Compostos Ferrosos/química , Polietilenos/química , Tensoativos/química , Cetrimônio , Temperatura Baixa , Materiais de Construção , Humanos , Teste de Materiais , Resistência à Tração
16.
Opt Express ; 23(9): 11783-9, 2015 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-25969269

RESUMO

We theoretically demonstrate spontaneous PT-symmetry breaking behavior of surface-plasmon polaritons (SPP) in coupled double-slab (DS) waveguides. By virtue of a flat-top field at critical wavelength, the imaginary index of a DS-SPP mode can be controlled via changing the core thickness, while the real index is kept constant. Therefore, a waveguide coupler that consists of a pair of DS-SPP waveguides with different core thicknesses can represent a passive PT-symmetric system, which always maintains symmetry under a real potential. This set-up also represents a good opportunity to investigate the underlying physics of PT-symmetry breaking in non-Hermitian Hamiltonian systems.

17.
Opt Express ; 23(13): 17443-9, 2015 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-26191753

RESUMO

Exploiting moiré interference, we make a new type of reconfigurable metamaterials and study their transmission tunability for incident electromagnetic waves. The moiré pattern is formed by overlapping two transparent layers, each of which has a periodic metallic pattern, and the cluster size of the resulting moiré pattern can be varied by changing the relative superposition angle of the two layers. In our reconfigurable metamaterials, both the size and structural shape of the unit cell can be varied simultaneously through moiré interference. We show that the transmission of electromagnetic waves can be controlled from 90% to 10% at 11 GHz by experiments and numerical simulation. The reconfigurable metamaterial proposed here can be applied in bandpass filters and tunable modulation devices.

18.
Sensors (Basel) ; 15(9): 22798-810, 2015 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-26371007

RESUMO

Fully implantable hearing devices (FIHDs) have been developed as a new technology to overcome the disadvantages of conventional acoustic hearing aids. The implantable microphones currently used in FIHDs, however, have difficulty achieving high sensitivity to environmental sounds, low sensitivity to body noise, and ease of implantation. In general, implantable microphones may be placed under the skin in the temporal bone region of the skull. In this situation, body noise picked up during mastication and touching can be significant, and the layer of skin and hair can both attenuate and distort sounds. The new approach presently proposed is a microphone implanted at the tympanic membrane. This method increases the microphone's sensitivity by utilizing the pinna's directionally dependent sound collection capabilities and the natural resonances of the ear canal. The sensitivity and insertion loss of this microphone were measured in human cadaveric specimens in the 0.1 to 16 kHz frequency range. In addition, the maximum stable gain due to feedback between the trans-tympanic microphone and a round-window-drive transducer, was measured. The results confirmed in situ high-performance capabilities of the proposed trans-tympanic microphone.


Assuntos
Implantes Cocleares , Auxiliares de Audição , Membrana Timpânica/cirurgia , Humanos , Desenho de Prótese , Osso Temporal/cirurgia
19.
Neuroimage ; 100: 642-9, 2014 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-24983712

RESUMO

Animal models of salicylate-induced tinnitus have demonstrated that salicylate modulates neuronal activity in several brain structures leading to neuronal hyperactivity in auditory and non-auditory brain areas. In addition, these animal tinnitus models indicate that tinnitus can be a perceptual consequence of altered spontaneous neural activity along the auditory pathway. Peripheral and/or central effects of salicylate can account for neuronal activity changes in salicylate-induced tinnitus. Because of this ambiguity, an in vivo imaging study would be able to address the peripheral and/or central involvement of salicylate-induced tinnitus. Therefore, in the present study, we developed a novel manganese-enhanced magnetic resonance imaging (MEMRI) method to map the in vivo functional auditory tract in a salicylate-induced tinnitus animal model by administrating manganese through the round window. We found that acute salicylate-induced tinnitus resulted in higher manganese uptake in the cochlea and in the central auditory structures. Furthermore, serial MRI scans demonstrated that the manganese signal increased in an anterograde fashion from the cochlea to the cochlear nucleus. Therefore, our in vivo MEMRI data suggest that acute salicylate-induced tinnitus is associated with higher spontaneous neural activity both in peripheral and central auditory pathways.


Assuntos
Cóclea/fisiopatologia , Nervo Coclear/fisiopatologia , Núcleo Coclear/fisiopatologia , Imageamento por Ressonância Magnética/métodos , Zumbido/fisiopatologia , Animais , Vias Auditivas/fisiopatologia , Modelos Animais de Doenças , Aumento da Imagem , Manganês , Ratos , Ratos Sprague-Dawley
20.
Animals (Basel) ; 14(7)2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38612315

RESUMO

As high temperature and relative humidity (RH) are the main environmental factors causing heat stress, the temperature-humidity index (THI) serves as an indicator of heat stress in livestock animals. This study aimed to determine the effects of heat stress on the laying performance, physiological responses, egg quality, and blood profile of laying hens by subjecting them to environmental conditions with varying THI levels (68-85) for 28 days. The indicators of laying performance, such as feed intake (-30%) and egg production rate (-11%), significantly decreased in the hens exposed to severe heat stress (33 °C, 66% RH) compared to those exposed to thermoneutral conditions (21 °C, 68% RH). Moreover, severe heat stress reduced the egg yolk color, eggshell thickness and strength, and Haugh units of the eggs produced by the laying hens. Furthermore, a significant increase in serum K+ and a decrease in Na+ levels were observed in the hens subjected to severe heat stress compared with those under thermoneutral conditions. Our results indicate that heat stress alters the physiological responses and metabolism of laying hens, resulting in a lower egg quality and production rate.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA