Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Hip Int ; 33(4): 752-761, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35848138

RESUMO

INTRODUCTION: Intertrochanteric fractures are predominantly treated by dynamic hip screw (DHS) fixation. However, recent evidence has found acceptable clinical results following hemiarthroplasty for these fractures. Thus, a systematic review was conducted to compare hemiarthroplasty with DHS fixation for intertrochanteric fractures. METHODS: A computerised search was performed, using the databases Medline, EMBASE, CINAHL and the Cochrane Central Register of Controlled Trials, with supplementation from Google Scholar and appropriate reference lists. Studies with comparative data comparing clinical outcomes of hemiarthroplasty versus DHS fixation were included. Data were extracted and quality assessment of the papers performed by 2 reviewers. RESULTS: 320 articles were independently reviewed by the investigators. A total of 10 studies met the inclusion criteria, comprising 2 randomised controlled trials and 8 cohort designs. 7 of the studies assessed unstable fracture patterns. There was no difference in operating time (SMD -1.169 min; 95% CI, -0.657 to 0.689) or blood transfusion volume (SMD-0.110 units; 95% CI, -0.520 to 0.891) between modalities. There was also no difference in length of stay (SMD -0.778 days; 95% CI, -0.606 to 0.336), mortality (RR 0.942; 95% CI, 0.749-1.183) or major complications. Hemiarthroplasty conferred significantly better Harris Hip Scores at 12 months (SMD 12.3; 95% CI, 0.0135-2.789) and allowed earlier weight-bearing than DHS fixation. DISCUSSION: Qualitative and quantitative compilation of the included studies demonstrates hemiarthroplasty to result in better functional scores and a quicker time to weight-bearing than DHS fixation for intertrochanteric fractures. Results are comparable for other major parameters, including operative time, length of stay and mortality. Thus, hemiarthroplasty is a suitable alternative to DHS fixation for unstable intertrochanteric fractures in elderly patients.


Assuntos
Artroplastia de Quadril , Hemiartroplastia , Fraturas do Quadril , Humanos , Idoso , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Parafusos Ósseos , Fraturas do Quadril/cirurgia
2.
Orthop J Sports Med ; 11(8): 23259671231155885, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37576458

RESUMO

Background: Diagnostic needle arthroscopy offers an alternative imaging modality to magnetic resonance imaging (MRI) for the diagnosis of intra-articular pathology. Purpose: To compare the accuracy of a needle arthroscopy device (Mi-eye2) versus MRI in identifying intra-articular anatomic abnormalities in the glenohumeral joint, with formal arthroscopy as the gold standard. Study Design: Cohort study; Level of evidence, 2. Methods: A total of 22 patients underwent diagnostic needle arthroscopy of the shoulder, of whom 20 had preoperative MRI scans. A standardized 12-point noninstrumented diagnostic arthroscopy was performed on each patient using the 0° needle arthroscope, followed by a 30°, 4 mm-diameter conventional arthroscope. Intraoperative images were randomized and reviewed by 2 independent blinded fellowship-trained shoulder surgeons for identification of key pathology and anatomic structures. The MRI scans were reviewed by a single musculoskeletal radiologist to identify pathology in the same key areas. Results: For the identification of rotator cuff pathology, needle arthroscopy (sensitivity, 0.75; specificity, 1.00) was superior to MRI (sensitivity, 0.75; specificity, 0.75) with an interobserver reliability (κ) of 0.703. For long head of the biceps pathology, needle arthroscopy (sensitivity, 0.67; specificity, 0.95) was superior to MRI (sensitivity, 0.00; specificity, 0.83). It was less accurate for labral (sensitivity, 0.33; specificity, 0.50; κ = 0.522) and articular cartilage pathology (sensitivity, 0.00; specificity, 0.94; κ = 0.353). The number of anatomic structures that could be clearly identified was 8.35 of 12 (69.58%) for needle arthroscopy versus 10.35 of 12 (86.25%) for standard arthroscopy. Conclusion: Diagnostic needle arthroscopy was found to be more accurate than MRI for the diagnosis of rotator cuff and long head of the biceps pathology but was less accurate for diagnosing labral and cartilage pathology. Although the field of view of a 0° needle arthroscope is not equivalent to a 30° conventional arthroscope, it presents an alternative with potential for use in an outpatient setting.

3.
Cureus ; 15(5): e38621, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37284354

RESUMO

Background There are a number of different techniques available for the repair of distal biceps tendon ruptures. Recent evidence has revealed satisfactory clinical outcomes for suture button techniques. Aims The aim of this study was to determine if the ToggleLocTM soft tissue fixation device (Zimmer Biomet, Warsaw, Indiana) confers satisfactory clinical outcomes in the surgical management of distal biceps ruptures. Methods Twelve consecutive patients underwent distal biceps repair using the ToggleLocTM soft tissue fixation device over a two-year period. Patient-Reported Outcome Measures (PROMs) were collected by means of validated questionnaires on two occasions. Symptoms and function were quantified using the Disabilities of the Arm, Shoulder and Hand (DASH) score and the Oxford Elbow Score (OES). Patient-reported health scores were determined using the EQ-5D-3L (European Quality of Life 5 Dimensions 3 Level Version) questionnaire. Results The mean initial follow-up time was 10.4 months and the mean final follow-up time was 34.6 months. The mean DASH score at the initial follow-up was 5.9 (se = 3.6), compared to 2.9 (se = 1.0) at the final follow-up (p = 0.30). The mean OES at the initial follow-up was 91.5 (se = 4.1); and 91.5 (se = 5.2) at the final follow-up (p = 0.23). The mean EQ-5D-3L level sum score at the initial follow-up was 5.3 (se = 0.3); and 5.8 (se = 0.5) at the final follow-up (p = 0.34). Discussion The ToggleLocTM soft tissue fixation device confers satisfactory clinical outcomes, as determined by PROMS, in the surgical management of distal biceps ruptures.

4.
Shoulder Elbow ; 11(1 Suppl): 46-51, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-31019562

RESUMO

BACKGROUND: A number of radiographic signs have been previously demonstrated to be associated with degenerative rotator cuff tears. An ability to predict the presence of a tear by radiography would permit the early commencement of appropriate treatment and the avoidance of unnecessary invasive investigations. The aim of the present study was to determine the accuracy of using radiographic signs to predict the presence of a cuff tear on arthroscopy. METHODS: Fifty consecutive patients who had undergone shoulder arthroscopy and had pre-operative plain radiographs were included. Pre-operative radiographs were reviewed by a consultant shoulder surgeon, a consultant radiologist and a senior clinical fellow for the following signs: acromial spur; subjective reduction of subacromial space; sourcil sign; acromial acetabularization; os acromiale; greater tuberosity cortical irregularity; greater tuberosity sclerosis; humeral head rounding; cyst; and reduction in acromiohumeral head distance. RESULTS: The presence of tuberosity sclerosis (p < 0.0001), tuberosity irregularities (p < 0.0001), tuberosity cyst (p = 0.004) and sourcil sign (p = 0.019) was associated with the presence of a rotator cuff tear. The combined sensitivity of prediction of tear by the observers following radiographic review was 91.7%, with a combined negative predictive value of 80%. CONCLUSIONS: The assessment of radiographs by senior clinicians is a useful tool for confirming the absence of a rotator cuff tear.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA