Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Catheter Cardiovasc Interv ; 101(1): 13-21, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378691

RESUMO

OBJECTIVES: To compare the efficacy and safety of the dual-therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (O-SES) in patients with and without acute coronary syndrome (ACS) included in the SORT OUT X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with ACS when compared to patients without ACS. Whether the results from the SORT OUT X study apply to patients with and without ACS remains unknown. METHODS: In total, 3146 patients were randomized to stent implantation with DTS (n = 1578; ACS: n = 856) or O-SES (n = 1568; ACS: n = 854). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was higher in the DTS group compared to the O-SES group, both among patients with ACS (6.7% vs. 4.1%; incidence rate ratio: 1.65 [95% confidence interval, CI: 1.08-2.52]) and without ACS (6.0% vs. 3.2%; incidence rate ratio: 1.88 [95% CI: 1.13-3.14]). The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without ACS CONCLUSION: Compared to the O-SES, the DTS was associated with a higher risk of TLF at 12 months in patients with and without ACS. The differences were mainly explained by higher rates of TLR.


Assuntos
Síndrome Coronariana Aguda , Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Sirolimo/efeitos adversos , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/terapia , Síndrome Coronariana Aguda/complicações , Doença da Artéria Coronariana/terapia , Fatores de Risco , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Implantes Absorvíveis , Fármacos Cardiovasculares/efeitos adversos , Fatores de Tempo , Desenho de Prótese , Infarto do Miocárdio/etiologia , Stents Farmacológicos/efeitos adversos
2.
Circulation ; 143(22): 2155-2165, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33823606

RESUMO

BACKGROUND: Target lesion failure remains an issue with contemporary drug-eluting stents. Thus, the dual-therapy sirolimus-eluting and CD34+ antibody-coated Combo stent (DTS) was designed to further improve early healing. This study aimed to investigate whether the DTS is noninferior to the sirolimus-eluting Orsiro stent (SES) in an all-comers patient population. METHODS: The SORT OUT X (Combo Stent Versus Orsiro Stent) trial, was a large-scale, randomized, multicenter, single-blind, 2-arm, noninferiority trial with registry-based follow-up. The primary end point target lesion failure was a composite of cardiac death, myocardial infarction, or target lesion revascularization within 12 months, analyzed using intention-to-treat. The trial was powered for assessing target lesion failure noninferiority of the DTS compared with the SES with a predetermined noninferiority margin of 0.021. RESULTS: A total of 3146 patients were randomized to treatment with the DTS (1578 patients; 2008 lesions) or SES (1568 patients; 1982 lesions). At 12 months, intention-to-treat analysis showed that 100 patients (6.3%) assigned the DTS and 58 patients (3.7%) assigned the SES met the primary end point (absolute risk difference, 2.6% [upper limit of 1-sided 95% CI, 4.1%]; P (noninferiority)=0.76). The SES was superior to the DTS (incidence rate ratios for target lesion failure, 1.74 [95% CI, 1.26-2.41]; P=0.00086). The difference was explained mainly by a higher incidence of target lesion revascularization in the DTS group compared with the SES group (53 [3.4%] vs. 24 [1.5%]; incidence rate ratio, 2.22 [95% CI, 1.37-3.61]; P=0.0012). CONCLUSIONS: The DTS did not confirm noninferiority to the SES for target lesion failure at 12 months in an all-comer population. The SES was superior to the DTS mainly because the DTS was associated with an increased risk of target lesion revascularization. However, rates of death, cardiac death, and myocardial infarction at 12 months did not differ significantly between the 2 stent groups. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03216733.


Assuntos
Antibacterianos/uso terapêutico , Antígenos CD34/metabolismo , Stents Farmacológicos/normas , Intervenção Coronária Percutânea/métodos , Sirolimo/uso terapêutico , Idoso , Antibacterianos/farmacologia , Feminino , Humanos , Masculino , Sirolimo/farmacologia , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 99(7): 1965-1975, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35384254

RESUMO

OBJECTIVES: To compare the efficacy and safety of the dual therapy CD34 antibody-covered sirolimus-eluting Combo stent (DTS) and the sirolimus-eluting Orsiro stent (SES) in patients with and without diabetes mellitus (DM) included in the Scandinavian Organization for Randomized Trials with Clinical Outcome (SORT OUT) X study. BACKGROUND: The incidence of target lesion failure (TLF) after treatment with modern drug-eluting stents has been reported to be significantly higher in patients with DM when compared to patients without DM. Thus, whether the results from the SORT OUT X study apply to patients with and without DM remains unknown. METHODS: In total 3146 patients were randomized to stent implantation with DTS (n = 1578; DM: n = 279) or SES (n = 1568; DM: n = 271). The primary end point, TLF, was a composite of cardiac death, target-lesion myocardial infarction (MI), or target lesion revascularization (TLR) within 1 year. RESULTS: At 1 year, the rate of TLF was increased in the DTS group compared to the SES group, both among patients with DM (9.3% vs. 4.8%; risk difference: 4.5%; incidence rate ratio: 1.99, 95% confidence interval [CI]: 1.02-3.90) and without DM (5.7% vs. 3.5%; incidence rate ratio: 1.67, 95% CI: 1.15-2.42). The differences were mainly explained by higher rates of TLR. CONCLUSION: Compared to the SES, the DTS was associated with an increased risk of TLF at 12 months in patients with and without DM. The differences were mainly explained by higher rates of TLR, whereas rates of cardiac death and target lesion MI did not differ significantly between the two stent groups in patients with or without DM.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Infarto do Miocárdio , Intervenção Coronária Percutânea , Implantes Absorvíveis , Antígenos CD34/imunologia , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/terapia , Morte , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Humanos , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sirolimo/efeitos adversos , Stents , Resultado do Tratamento
4.
Am Heart J ; 202: 49-53, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29807307

RESUMO

BACKGROUND: The Combo stent (OrbusNeich, Hoevelaken, the Netherlands) combining an abluminal, bioabsorbable polymer eluting sirolimus with a luminal CD34+ antibody to capture endothelial progenitor cells has been developed to further improve safety and efficacy of coronary interventions. We have designed a large-scale registry-based randomized clinical trial to compare the Combo stent to the Orsiro stent (Biotronik, Bülach, Switzerland) in patients undergoing percutaneous coronary intervention. METHODS: The SORT OUT X study will randomly assign 3,140 patients to treatment with Combo or Orsiro stents at 3 sites in Western Denmark. Patients are eligible if they are ≥18 years old, have chronic stable coronary artery disease or acute coronary syndromes, and have ≥1 coronary lesion with >50% diameter stenosis requiring treatment with a drug-eluting stent. The primary end point target lesion failure is a composite of cardiac death, myocardial infarction (not related to other than index lesion), or target lesion revascularization within 12 months. Clinically driven event detection will be derived from validated Danish registries. An event rate of 4.2% is assumed in each stent group. With a sample size of 1,570 patients in each treatment arm, a 2-group large-sample normal approximation test of proportions with a 1-sided 5% significance level will have 90% power to detect noninferiority of the Combo stent compared with the Orsiro stent with a predetermined noninferiority margin of 2.1%. CONCLUSION: The SORT OUT X trial will determine whether the dual-therapy Combo stent is noninferior to the Orsiro stent with respect to clinically driven events (ClinicalTrials.govNCT03216733).


Assuntos
Síndrome Coronariana Aguda/terapia , Antígenos CD34/imunologia , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea , Sirolimo/administração & dosagem , Adulto , Anticorpos , Materiais Revestidos Biocompatíveis , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Projetos de Pesquisa , Método Simples-Cego
5.
EuroIntervention ; 19(8): 676-683, 2023 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-37584207

RESUMO

BACKGROUND: Target lesion failure (TLF) remains an issue with contemporary drug-eluting stents. The dual-therapy sirolimus-eluting and CD34 antibody-coated COMBO stent (DTS) was designed to improve early healing. AIMS: We aimed to compare the 3-year outcomes of the DTS and the sirolimus-eluting Orsiro stent (SES) in all-comer patients treated with percutaneous coronary intervention. METHODS: The SORT OUT X trial is a prospective multicentre randomised clinical trial with a registry-based follow-up comparing DTS and SES. The primary endpoint, TLF, is a composite of cardiac death, myocardial infarction or target lesion revascularisation (TLR). RESULTS: A total of 3,146 patients were randomised to treatment with the DTS (1,578 patients) or the SES (1,568 patients). At 3 years, an intention-to-treat analysis showed that 155 patients (9.8%) who were assigned the DTS and 118 patients (7.5%) who were assigned the SES met the primary endpoint (incidence rate ratio for TLF=1.33, 95% confidence interval: 1.04-1.70; p=0.02). This difference was caused by a significantly higher TLF rate in the DTS group compared to the SES group within the first year, which was mainly explained by a higher incidence of TLR in the DTS group compared to the SES group. Of note, the TLF rates were almost identical from 1 year to 3 years in both stent groups. CONCLUSIONS: At 3 years, the SES was superior to the DTS, mainly because the DTS was associated with an increased risk of TLF within the first year but not from 1 to 3 years. CLINICALTRIALS: gov: NCT03216733.

6.
J Invasive Cardiol ; 33(4): E318-E319, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33794484

RESUMO

A 46-year-old man with type 1 diabetes underwent percutaneous coronary intervention with bioresorbable scaffold implantation for a long segment of physiologically significant left anterior descending coronary artery disease. The procedure was complicated by longitudinal stent deformation (LSD). The images carry several important educational messages for clinicians. First, as with all stents, LSD is possible in extreme circumstances. Second, as the device is not seen angiographically, it is imperative that optical coherence tomography be performed to confirm LSD. When recognized and treated, the procedural and long-term outcomes are good for this complication.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Stents Farmacológicos/efeitos adversos , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Tomografia de Coerência Óptica , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA