Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Emerg Med ; 43(3): e175-9, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20456904

RESUMO

BACKGROUND: The presence of free intraperitoneal gas usually warrants emergent surgery. In rare instances, however, non-surgical conditions such as jejunal diverticulosis can cause pneumoperitoneum and do not require intervention. OBJECTIVES: The objective of this article is to provide the computed tomography (CT) scan findings of jejunal diverticulosis causing pneumoperitoneum. The article will also discuss other non-surgical causes of spontaneous pneumoperitoneum to increase awareness and avoid unnecessary surgery. CASE REPORT: We describe a case of recurrent pneumoperitoneum due to jejunal diverticulosis in which the patient remained asymptomatic and free of complications with repeated evaluations in the emergency department over the course of 18 months. CONCLUSION: Although spontaneous pneumoperitoneum due to jejunal diverticulosis is a rare finding, when it does occur, this condition must be distinguished from other forms of pneumoperitoneum to avoid unnecessary surgery. CT scan findings of multiple rounded, variably sized jejunal outpouchings filled with oral contrast are helpful in diagnosing jejunal diverticulosis and confirming the decision for conservative management of the patient.


Assuntos
Divertículo/diagnóstico por imagem , Doenças do Jejuno/diagnóstico por imagem , Pneumoperitônio/diagnóstico por imagem , Pneumoperitônio/etiologia , Idoso , Doenças Assintomáticas , Humanos , Achados Incidentais , Masculino , Recidiva , Tomografia Computadorizada por Raios X
2.
Int J Gastrointest Cancer ; 35(1): 83-8, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15722578

RESUMO

A 58-yr-old male with a history of hepatitis C virus infection, presented with a 2-mo history of intractable left upper abdominal pain. He had fallen from a ladder 2 yr previously, landing on his left side. Abdominal computed tomography identified a large cystic mass in the spleen. The patient was brought to the operating room with a presumptive diagnosis of symptomatic, post-traumatic, false cyst of the spleen. Instead, at surgery, a splenic mass with dense adhesions to the diaphragm and stomach was found. On final histological analysis, it was diagnosed to be a large B-cell lymphoma. Despite its rarity, gastroenterologists and surgeons should be aware of large B-cell lymphoma when encountering cystic lesions of the spleen, because the management of benign cystic disease is usually nonsurgical.


Assuntos
Cistos/diagnóstico , Linfoma de Células B/diagnóstico , Linfoma Difuso de Grandes Células B/diagnóstico , Esplenopatias/diagnóstico , Neoplasias Esplênicas/diagnóstico , Dor Abdominal/etiologia , Cistos/patologia , Cistos/cirurgia , Diagnóstico Diferencial , Hepatite C/complicações , Humanos , Linfoma de Células B/patologia , Linfoma de Células B/cirurgia , Linfoma Difuso de Grandes Células B/patologia , Linfoma Difuso de Grandes Células B/cirurgia , Masculino , Pessoa de Meia-Idade , Esplenopatias/patologia , Esplenopatias/cirurgia , Neoplasias Esplênicas/patologia , Neoplasias Esplênicas/cirurgia
3.
J Am Coll Surg ; 211(4): 481-4, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20822742

RESUMO

BACKGROUND: Unrecognized CT findings of a prosthetic plug used in inguinal hernia repair can lead to incorrect diagnosis or unnecessary workup of a patient. The objective of this study is to review the expected CT findings present in patients with a history of plug repair. STUDY DESIGN: Retrospective cohort study retrieving clinical and image data from a single-institution database. Patients who underwent prosthetic plug hernia repair during a 5-year period at our institution had their records queried for subsequent abdominal CT scans. These CT scans were reviewed by 2 radiologists for findings referable to the hernia repair. RESULTS: Five-hundred and sixty-four consecutive patients underwent prosthetic plug hernia repair during a 5-year period. Fifty-one patients who had had 55 surgical procedures had subsequent CT scans, none in the early postoperative period. Readers identified 100% of the plugs, 68% of which were described as round or oval in shape. All the plugs were in close proximity to the inferior epigastric artery and were of low density on CT images. Surgical scar was identifiable in 87% of patients. Thirty-two patients (63%) had a second CT scan, demonstrating no change in size and location of the plugoma. CONCLUSIONS: A prosthetic mesh plug is easily seen on CT images, typically appearing as a smooth round or oval hypodense mass close to the inferior epigastric artery, deep to a surgical scar, and stable over time. It can usually be distinguished from pathologic findings. It is important that the radiologist be familiar with the patient's surgical history when interpreting these images.


Assuntos
Hérnia Inguinal/diagnóstico por imagem , Hérnia Inguinal/cirurgia , Telas Cirúrgicas , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Implantação de Prótese , Estudos Retrospectivos
4.
Ultrasound Q ; 26(2): 83-99, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20498564

RESUMO

Doppler ultrasound is routinely used in the clinical setting to evaluate blood flow in many major vessels of the body. Spectral Doppler is used to display the normal and abnormal signature waveforms that are unique to each vessel. It is important for the sonographer and the radiologist to recognize both what is normal and what is abnormal in a spectral Doppler display. In this review, we briefly explain the physics behind Doppler ultrasound and some of the most common mathematical equations applied in a routine clinical examination. We also describe and demonstrate normal versus abnormal spectral Doppler signature waveforms of vessels in the neck, abdomen, pelvis, and fetus.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia de Intervenção/métodos , Abdome/irrigação sanguínea , Abdome/diagnóstico por imagem , Aorta Abdominal/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Artérias Carótidas/diagnóstico por imagem , Feminino , Humanos , Rim/irrigação sanguínea , Rim/diagnóstico por imagem , Masculino , Artéria Mesentérica Superior/diagnóstico por imagem , Pelve/irrigação sanguínea , Pelve/diagnóstico por imagem , Fluxo Sanguíneo Regional/fisiologia , Sensibilidade e Especificidade , Útero/irrigação sanguínea , Útero/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA