RESUMO
Exogenous polyamines, including putrescine (PUT), spermidine (SPD), and spermine (SPM), and the irreversible inhibitor of the rate-limiting enzyme ornithine decarboxylase (ODC) of polyamine biosynthesis, α-difluoromethylornithine (DFMO), are implicated as stimulants for bone formation. We demonstrate in this study the osteogenic potential of exogenous polyamines and DFMO in human osteoblasts (hOBs), murine monocyte cell line RAW 264.7, and an ovariectomized rat model. The effect of polyamines and DFMO on hOBs and RAW 264.7 cells was studied by analyzing gene expression, alkaline phosphatase (ALP) activity, tartrate-resistant acid phosphatase (TRAP) activity, and matrix mineralization. Ovariectomized rats were treated with polyamines and DFMO and analyzed by micro computed tomography (micro CT). The mRNA level of the early onset genes of osteogenic differentiation, Runt-related transcription factor 2 (Runx2) and ALP, was significantly elevated in hOBs under osteogenic conditions, while both ALP activity and matrix mineralization were enhanced by exogenous polyamines and DFMO. Under osteoclastogenic conditions, the gene expression of both receptor activator of nuclear factor-κB (RANK) and nuclear factor of activated T-cells, cytoplasmic 1 (NFATc1) was reduced, and TRAP activity was suppressed by exogenous polyamines and DFMO in RAW 264.7 cells. In an osteoporotic animal model of ovariectomized rats, SPM and DFMO were found to improve bone volume in rat femurs, while trabecular thickness was increased in all treatment groups. Results from this study provide in vitro and in vivo evidence indicating that polyamines and DFMO act as stimulants for bone formation, and their osteogenic effect may be associated with the suppression of osteoclastogenesis.
Assuntos
Diferenciação Celular , Eflornitina , Osteoblastos , Osteoclastos , Osteogênese , Poliaminas , Animais , Camundongos , Osteoclastos/efeitos dos fármacos , Osteoclastos/metabolismo , Osteogênese/efeitos dos fármacos , Ratos , Humanos , Diferenciação Celular/efeitos dos fármacos , Eflornitina/farmacologia , Feminino , Poliaminas/metabolismo , Osteoblastos/efeitos dos fármacos , Osteoblastos/metabolismo , Células RAW 264.7 , Ovariectomia , Ratos Sprague-Dawley , Espermidina/farmacologiaRESUMO
Amyotrophic lateral sclerosis (ALS) causes people to have difficulty communicating with others or devices. In this paper, multi-task learning with denoising and classification tasks is used to develop a robust steady-state visual evoked potential-based brain-computer interface (SSVEP-based BCI), which can help people communicate with others. To ease the operation of the input interface, a single channel-based SSVEP-based BCI is selected. To increase the practicality of SSVEP-based BCI, multi-task learning is adopted to develop the neural network-based intelligent system, which can suppress the noise components and obtain a high level of accuracy of classification. Thus, denoising and classification tasks are selected in multi-task learning. The experimental results show that the proposed multi-task learning can effectively integrate the advantages of denoising and discriminative characteristics and outperform other approaches. Therefore, multi-task learning with denoising and classification tasks is very suitable for developing an SSVEP-based BCI for practical applications. In the future, an augmentative and alternative communication interface can be implemented and examined for helping people with ALS communicate with others in their daily lives.
Assuntos
Esclerose Lateral Amiotrófica , Interfaces Cérebro-Computador , Humanos , Potenciais Evocados Visuais , Redes Neurais de Computação , Eletroencefalografia/métodos , Estimulação Luminosa , AlgoritmosRESUMO
The traditional needle cricothyroidotomy procedure is performed blindly without any medical equipment. Complications including posterior tracheal wall perforation, accidental vessel puncture, and missed tracheal puncture are reported. Therefore, we proposed a dual-wavelength fiber-optic technique based on the technique of near-infrared spectroscopy to assist operators performing needle cricothyroidotomy in a swine model. We embedded optical fibers in a 16-gauge intravenous needle catheter. Real-time data were displayed on an oscilloscope, and we used the program to analyze the data immediately. The change of optical density corresponding to 690-nm and 850-nm wavelengths and hemoglobin parameters (HbO2 and Hb concentrations) was analyzed immediately using the program in the laptop. Unique and significant optical differences were presented in this experiment. We could easily identify every different tissue by the change of optical density corresponding to 690-nm and 850-nm wavelengths and hemoglobin parameters (HbO2 and Hb concentrations). Statistical method (Kruskal-Wallis H test) was used to compare differences in tissues at each time-point, respectively. The p values in every tissue in optical density change corresponding to 690 nm and 850 nm were all < 0.001. Furthermore, the p values in every tissue in Hb and HbO2 were also all < 0.001. The results were statistically significant. This is the first and novel study to introduce a dual-wavelength embedded fibers into a standard cricothyroidotomy needle. This proposed system might be helpful to provide us real-time information of the advanced needle tip to decrease possible complications.
Assuntos
Tecnologia de Fibra Óptica , Músculos Laríngeos/patologia , Agulhas , Animais , Músculos Laríngeos/diagnóstico por imagem , Oxiemoglobinas/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho , Suínos , Traqueia/diagnóstico por imagem , Traqueia/fisiologia , UltrassonografiaRESUMO
In clinical practice, the catheter has to be placed at an accurate position during anesthesia administration. However, effectively guiding the catheter to the accurate position in deeper tissues can be difficult for an inexperienced practitioner. We aimed to address the current issues associated with catheter placement using a novel smart assistance system for blood vessel catheter placement. We used a hollow introducer needle embedded with dual wavelength (690 and 850 nm) optical fibers to advance the tip into the subclavian vessels in anesthetized piglets. The results showed average optical density changes, and the difference between the absorption spectra and hemoglobin concentrations of different tissue components effectively identified different tissues (p < 0.05). The radial basis function neural network (RBFNN) technique was applied to distinguish tissue components (the F-measure value and accuracy were 93.02% and 94%, respectively). Finally, animal experiments were designed to validate the performance of the proposed system. Using this system based on oximetry, we easily navigated the needle tip to the target vessel. Based on the experimental results, the proposed system could effectively distinguish different tissue layers of the animals.
Assuntos
Técnicas Biossensoriais/métodos , Vasos Sanguíneos/anatomia & histologia , Oximetria/métodos , Artéria Subclávia/diagnóstico por imagem , Anestesia/tendências , Vasos Sanguíneos/diagnóstico por imagem , Catéteres/tendências , Humanos , Agulhas , Fibras Ópticas/tendências , Artéria Subclávia/fisiologiaRESUMO
Cardiovascular disease (CVD) is one of the leading causes of death globally. Currently, clinical diagnosis of CVD primarily relies on electrocardiograms (ECG), which are relatively easier to identify compared to other diagnostic methods. However, ensuring the accuracy of ECG readings requires specialized training for healthcare professionals. Therefore, developing a CVD diagnostic system based on ECGs can provide preliminary diagnostic results, effectively reducing the workload of healthcare staff and enhancing the accuracy of CVD diagnosis. In this study, a deep neural network with a cross-stage partial network and a cross-attention-based transformer is used to develop an ECG-based CVD decision system. To accurately represent the characteristics of ECG, the cross-stage partial network is employed to extract embedding features. This network can effectively capture and leverage partial information from different stages, enhancing the feature extraction process. To effectively distill the embedding features, a cross-attention-based transformer model, known for its robust scalability that enables it to process data sequences with different lengths and complexities, is employed to extract meaningful embedding features, resulting in more accurate outcomes. The experimental results showed that the challenge scoring metric of the proposed approach is 0.6112, which outperforms others. Therefore, the proposed ECG-based CVD decision system is useful for clinical diagnosis.
RESUMO
In thoracic surgery, the double lumen endotracheal tube (DLT) is used for differential ventilation of the lung. DLT allows lung collapse on the surgical side that requires access to the thoracic and mediastinal areas. DLT placement for a given patient depends on two settings: a tube of the correct size (or 'size') and to the correct insertion depth (or 'depth'). Incorrect DLT placements cause oxygen desaturation or carbon dioxide retention in the patient, with possible surgical failure. No guideline on these settings is currently available for anesthesiologists, except for the aid by bronchoscopy. In this study, we aimed to predict DLT 'depths' and 'sizes' applied earlier on a group of patients (n = 231) using a computer modeling approach. First, for these patients we retrospectively determined the correlation coefficient (r) of each of the 17 body parameters against 'depth' and 'size'. Those parameters having r > 0.5 and that could be easily obtained or measured were selected. They were, for both DLT settings: (a) sex, (b) height, (c) tracheal diameter (measured from X-ray), and (d) weight. For 'size', a fifth parameter, (e) chest circumference was added. Based on these four or five parameters, we modeled the clinical DLT settings using a Support Vector Machine (SVM). After excluding statistical outliers (±2 SD), 83.5% of the subjects were left for 'depth' in the modeling, and similarly 85.3% for 'size'. SVM predicted 'depths' matched with their clinical values at a r of 0.91, and for 'sizes', at an r of 0.82. The less satisfactory result on 'size' prediction was likely due to the small target choices (n = 4) and the uneven data distribution. Furthermore, SVM outperformed other common models, such as linear regression. In conclusion, this first model for predicting the two DLT key settings gave satisfactory results. Findings would help anesthesiologists in applying DLT procedures more confidently in an evidence-based way.
RESUMO
BACKGROUND: In previous animal studies, preemptive treatments with N-methyl-d-aspartate (NMDA) antagonists were ineffective at preventing incision-induced allodynia. It is very likely that the model was not clinically relevant for testing treatment effects on postoperative pain. The beneficial effects of preemptive treatment can be verified only by treatments with a pharmacologically proven effect in a specific pain type or animal model. We previously showed that NMDA receptor antagonists effectively alleviate enhanced mechanical hyperalgesia after plantar incision in adult rats that had been given an intraplantar injection of carrageenan as neonates. Here, using this modified model, we tested the efficacy of preemptive treatment with the NMDA antagonist MK-801. METHODS: We injected rat pups subcutaneously with 0.25% carrageenan or saline in the plantar surface of one hindpaw on postnatal day 1. On postnatal day 50, rats were killed and the ipsilateral side of the lumbar spinal cords were harvested for biochemical analysis of the expression of NR2A and NR2B at baseline, 2 hours, 4 hours, 8 hours, and 24 hours after plantar incision (n = 5 per group for each time point). For pharmacological study, rats were allocated into one of the following groups: 1 intrathecal injection of 40 nmol MK-801 15 minutes before plantar incision, 1 intrathecal injection 30 minutes after plantar incision, or 2 injections of 20 nmol or 40 nmol given at 15 minutes and 60 minutes after plantar incision (n = 10 per group for neonatally saline-treated and 12 for carrageenan-treated rats). Paw withdrawal thresholds were measured with von Frey filaments, and weight-bearing percentages were measured hourly after plantar incision. RESULTS: Expressions of NMDA receptor subunits NR2A and NR2B were increased maximally 4 hours postoperatively and were significantly greater in carrageenan-treated rats than in saline-treated rats. Tests of pain sensitivity showed that MK-801 significantly alleviated the incision-induced mechanical hyperalgesia and increased weight-bearing percentage on the injured paw in carrageenan-treated rats. However, preincisional treatment was not superior to postincisional treatment as assessed during the 6-hour postoperative observation period. Groups with 2 successive postoperative injections exhibited prolonged analgesic effects. Only the group that received 2 postoperative injections and increased total dosage had improved analgesic indices. CONCLUSIONS: Under conditions of proven analgesic action of an NMDA antagonist, we demonstrated that preincisional treatment is not more beneficial than postincisional treatment for postoperative pain relief in the modified animal model. Increasing the duration of administration and/or total dosage had an incremental analgesic effect in comparison with a single injection.
Assuntos
Modelos Animais de Doenças , Maleato de Dizocilpina/administração & dosagem , Medição da Dor/efeitos dos fármacos , Dor Pós-Operatória/prevenção & controle , Receptores de N-Metil-D-Aspartato/antagonistas & inibidores , Analgesia/métodos , Animais , Animais Recém-Nascidos , Antagonistas de Aminoácidos Excitatórios/administração & dosagem , Feminino , Masculino , Medição da Dor/métodos , Dor Pós-Operatória/fisiopatologia , Gravidez , Cuidados Pré-Operatórios/métodos , Ratos , Ratos Sprague-Dawley , Receptores de N-Metil-D-Aspartato/biossínteseRESUMO
The sensitivity of pneumothorax diagnosis via handheld ultrasound is low, and there is no equipment suitable for use with life-threatening tension pneumothorax in a prehospital setting. This study proposes a novel technology involving optical fibers and near-infrared spectroscopy to assist in needle thoracostomy decompression. The proposed system via the optical fibers emitted dual wavelengths of 690 and 850 nm, allowing distinction among different layers of tissue in vivo. The fundamental principle is the modified Beer-Lambert law (MBLL) which is the basis of near-infrared tissue spectroscopy. Changes in optical density corresponding to different wavelengths (690 and 850 nm) and hemoglobin parameters (levels of Hb and HbO2) were examined. The Kruskal-Wallis H test was used to compare the differences in parameter estimates among tissue layers; all p-values were < 0.001 relevant to 690 nm and 850 nm. In comparisons of Hb and HbO2 levels relative to those observed in the vein and artery, all p-values were also < 0.001. This study proposes a new optical probe to assist needle thoracostomy in a swine model. Different types of tissue can be identified by changes in optical density and hemoglobin parameters. The aid of the proposed system may yield fewer complications and a higher success rate in needle thoracostomy procedures.
RESUMO
Tracheobronchomegaly (also called Mounier-Kuhn syndrome) is a rare disease characterized by flaccid and markedly dilated trachea and main bronchi on inspiration with narrowing or collapse on expiration or cough. It is associated with recurrent lower respiratory tract infection. A 75-year-old man with unexpected giant tracheomegaly had a significant peritubal air leak which impeded an operation. Lumbar epidural anesthesia was performed for a subsequent operation without any sequela. Careful evaluation with chest radiography is basic to exclude a large airway. Chest computed tomography and fiber-optic bronchoscopy provided the diagnosis of a large airway. If a large airway is suspected, these examinations help to evaluate and manage the airway.
RESUMO
PURPOSE: This study aimed to evaluate whether a nonpharmacological approach through implementation of a communication improvement program (named CICARE for Connect, Introduce, Communicate, Ask, Respond and Exit) into standard operating procedure (SOP) in acute pain service (APS) improved satisfaction in patients receiving intravenous patient-controlled analgesia (IV-PCA). PATIENTS AND METHODS: This was a nonrandomized before-after study. Adult patients (aged between 20 and 80 years) who received IV-PCA after major surgery were included. Implementing CICARE into SOP was conducted in APS. Anonymous questionnaires were used to measure outcomes in this prospective two-part survey. The first part completed by APS nurses contained patients' characteristics, morphine dosage, delivery/demand ratios, IV-PCA side effects and pain at rest measured with an 11-point numeric rating scale (NRS, 0-10). A score of NRS ≥4 was defined as inadequately treated pain. The ten-question second part was completed by patients voluntarily after IV-PCA was discontinued. Each question was assessed with a 5-point Likert scale (1: extremely poor; 5: excellent). Patients were separated into "before" and "after" CICARE groups. Primary outcomes were patient global impression of improvement in pain (PGI-Improvement) and patient satisfaction. Secondary outcomes included quality of communication skills, instrument proficiency and accessibility/availability of IV-PCA. RESULTS: The response rate was 55.3%, with 187 usable questionnaires. CICARE effectively improved patient global impression of improvement in pain, patient satisfaction, communication skills and accessibility/availability of IV-PCA. No significant differences were noted in instrument proficiency, morphine dosage, delivery/demand ratios, rates of inadequately treated pain at rest and side effects of IV-PCA between groups. Paradoxical findings were noted between the rates of inadequately treated pain/side effects and PGI-Improvement in pain/patient satisfaction, which were affected by psychological factors. CONCLUSION: Nonpharmacological interventions carried out by implementing CICARE into SOP for APS effectively improved patient satisfaction and postoperative pain management quality, but this did not affect actual pain.
RESUMO
The left ventricular assist device (LVAD) is a battery-operated, mechanical pump-type device that helps in maintaining the pumping ability of a failing heart. Thromboembolism poses a significant risk during and after LVAD implantation. It occurs in up to 35% of patients with adverse sequelae. We present the case of a 75-year-old man who underwent coronary artery bypass graft surgery and LVAD implantation for acute myocardial ischemia and severe left ventricular dysfunction. However, subsequent transthoracic echocardiographic examination revealed an LVAD thrombus, and LVAD removal was suggested following the failure of thrombolytic therapy. After the LVAD cannula was removed, transesophageal echocardiography (TEE) revealed a residual thrombus in the left atrium. Thrombectomy was successfully performed by opening the left atrium with cardiopulmonary bypass. We believe that TEE monitoring aided the implantation and removal of the LVAD device. In this case, we found that TEE not only helped in monitoring the ventricular function but also in detecting other problems such as the residual thrombus. We strongly recommend TEE monitoring during the entire LVAD-removal procedure, particularly for patients who need to undergo LVAD removal because of thrombosis formation.
Assuntos
Remoção de Dispositivo/métodos , Ecocardiografia Transesofagiana , Cardiopatias/terapia , Coração Auxiliar/efeitos adversos , Trombose/terapia , Idoso , Átrios do Coração , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Trombose/diagnóstico por imagemRESUMO
We describe the successful management of extravasation injury to the left hand by contrast medium with stellate ganglion block and intra-arterial nitroglycerin in a patient which befell during contrast-enhanced imaging. The incidence of contrast-medium extravasation injury is increasing because of the convenience and availability of contrast-enhanced imaging and ease of injection access. Extravasation of contrast medium may results in severe pain, erythema, cyanosis, and edema or even skin necrosis, which is largely related to the ionization, osmolarity, and volume of the contrast medium. The conservative treatment is often adequate in small amount extravasation, but if the extravasation is overwhelming further energetic management is mandatory. A 29-year-old man was brought to our emergency because of diffuse abdominal pain and he was arranged to receive intravenous contrast media enhanced abdominal computed tomography for diagnosis. Ruptured appendicitis with abscess formation was suspected; then the patient underwent emergent appendectomy and drainage of the abscess. However, severe swelling and cyanotic change that radiated from the intravenous catheter insertion site in every direction over the entire dorsum of the left hand were noted after the surgery. Contrast-medium extravasation injury was highly contemplated and a left stellate ganglion block was performed immediately for relief of symptoms. The consulting surgeon ruled out compartment syndrome, but advised emergent left upper limb arteriography, which revealed signs of vasospasm with high intravascular pressure of the left distal ulnar and radial arteries; thus nitroglycerin was injected into left distal ulnar and radial arteries for relief of vasospasm. The clinical symptoms were improved after the above managements and the patient was discharged 7 days later without any sequela.