Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
N Engl J Med ; 380(17): 1618-1627, 2019 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-30883052

RESUMO

BACKGROUND: In two interim analyses of this trial, patients with advanced heart failure who were treated with a fully magnetically levitated centrifugal-flow left ventricular assist device were less likely to have pump thrombosis or nondisabling stroke than were patients treated with a mechanical-bearing axial-flow left ventricular assist device. METHODS: We randomly assigned patients with advanced heart failure to receive either the centrifugal-flow pump or the axial-flow pump irrespective of the intended goal of use (bridge to transplantation or destination therapy). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or remove a malfunctioning device. The principal secondary end point was pump replacement at 2 years. RESULTS: This final analysis included 1028 enrolled patients: 516 in the centrifugal-flow pump group and 512 in the axial-flow pump group. In the analysis of the primary end point, 397 patients (76.9%) in the centrifugal-flow pump group, as compared with 332 (64.8%) in the axial-flow pump group, remained alive and free of disabling stroke or reoperation to replace or remove a malfunctioning device at 2 years (relative risk, 0.84; 95% confidence interval [CI], 0.78 to 0.91; P<0.001 for superiority). Pump replacement was less common in the centrifugal-flow pump group than in the axial-flow pump group (12 patients [2.3%] vs. 57 patients [11.3%]; relative risk, 0.21; 95% CI, 0.11 to 0.38; P<0.001). The numbers of events per patient-year for stroke of any severity, major bleeding, and gastrointestinal hemorrhage were lower in the centrifugal-flow pump group than in the axial-flow pump group. CONCLUSIONS: Among patients with advanced heart failure, a fully magnetically levitated centrifugal-flow left ventricular assist device was associated with less frequent need for pump replacement than an axial-flow device and was superior with respect to survival free of disabling stroke or reoperation to replace or remove a malfunctioning device. (Funded by Abbott; MOMENTUM 3 ClinicalTrials.gov number, NCT02224755.).


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Desenho de Prótese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Coração Auxiliar/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Reoperação/estatística & dados numéricos , Acidente Vascular Cerebral/etiologia
2.
J Card Fail ; 28(7): 1158-1168, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35504508

RESUMO

BACKGROUND: As left ventricular assist device (LVAD) survival rates continue to improve, evaluating site-specific variability in outcomes can facilitate identifying targets for quality-improvement initiative opportunities in the field. METHODS: Deidentified center-specific outcomes were analyzed for HeartMate 3 (HM3) patients enrolled in the MOMENTUM 3 pivotal and continued access protocol trials. Centers < 25th percentile for HM3 volumes were excluded. Variability in risk-adjusted center mortality was assessed at 90 days and 2 years (conditional upon 90-day survival). Adverse event (AE) rates were compared across centers. RESULTS: In the 48 included centers (1958 patients), study-implant volumes ranged between 17 and 106 HM3s. Despite similar trial-inclusion criteria, patient demographics varied across sites, including age quartile ((Q)1-Q3:57-62 years), sex (73%-85% male), destination therapy intent (60%-84%), and INTERMACS profile 1-2 (16%-48%). Center mortality was highly variable, nadiring at ≤ 3.6% (≤ 25th percentile) and peaking at ≥ 10.4% (≥ 75th percentile) at 90 days and ≤ 10.2% and ≥ 18.7%, respectively, at 2 years. Centers with low mortality rates tended to have lower 2-year AE rates, but no center was a top performer for all AEs studied. CONCLUSIONS: Mortality and AEs were highly variable across MOMENTUM 3 centers. Studies are needed to improve our understanding of the drivers of outcome variability and to ascertain best practices associated with high-performing centers across the continuum of intraoperative to chronic stages of LVAD support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Feminino , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Taxa de Sobrevida , Resultado do Tratamento
3.
JAMA ; 328(12): 1233-1242, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36074476

RESUMO

Importance: Although durable left ventricular assist device (LVAD) therapy has emerged as an important treatment option for patients with advanced heart failure refractory to pharmacological support, outcomes, including survival, beyond 2 years remain poorly characterized. Objective: To report the composite end point of survival to transplant, recovery, or LVAD support free of debilitating stroke (Modified Rankin Scale score >3) or reoperation to replace the pump 5 years after the implant in participants who received the fully magnetically levitated centrifugal-flow HeartMate 3 or axial-flow HeartMate II LVAD in the MOMENTUM 3 randomized trial and were still receiving LVAD therapy at the 2-year follow-up. Design, Setting, and Participants: This observational study was a 5-year follow-up of the MOMENTUM 3 trial, conducted in 69 US centers, that demonstrated superiority of the centrifugal-flow LVAD to the axial-flow pump with respect to survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump at 2 years. A total of 295 patients were enrolled between June 2019 to April 2021 in the extended-phase study, with 5-year follow-up completed in September 2021. Exposures: Of 1020 patients in the investigational device exemption per-protocol population, 536 were still receiving LVAD support at 2 years, of whom 289 received the centrifugal-flow pump and 247 received the axial-flow pump. Main Outcomes and Measures: There were 10 end points evaluated at 5 years in the per-protocol population, including a composite of survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump between the centrifugal-flow and axial-flow pump groups and overall survival between the 2 groups. Results: A total of 477 patients (295 enrolled and 182 provided limited data) of 536 patients still receiving LVAD support at 2 years contributed to the extended-phase analysis (median age, 62 y; 86 [18%] women). The 5-year Kaplan-Meier estimate of survival to transplant, recovery, or LVAD support free of debilitating stroke or reoperation to replace the pump in the centrifugal-flow vs axial-flow group was 54.0% vs 29.7% (hazard ratio, 0.55 [95% CI, 0.45-0.67]; P < .001). Overall Kaplan-Meier survival was 58.4% in the centrifugal-flow group vs 43.7% in the axial-flow group (hazard ratio, 0.72 [95% CI, 0.58-0.89]; P = .003). Serious adverse events of stroke, bleeding, and pump thrombosis were less frequent in the centrifugal-flow pump group. Conclusions and Relevance: In this observational follow-up study of patients from the MOMENTUM 3 randomized trial, per-protocol analyses found that receipt of a fully magnetically levitated centrifugal-flow LVAD vs axial-flow LVAD was associated with a better composite outcome and higher likelihood of overall survival at 5 years. These findings support the use of the fully magnetically levitated LVAD. Trial Registration: ClinicalTrials.gov Identifier: NCT02224755 and NCT03982979.


Assuntos
Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Feminino , Seguimentos , Coração Auxiliar/efeitos adversos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
4.
Circulation ; 138(18): 1923-1934, 2018 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-29807933

RESUMO

BACKGROUND: The MOMENTUM 3 trial compares the centrifugal HeartMate 3 (HM3) with the axial HeartMate II (HMII) continuous-flow left ventricular assist system in patients with advanced heart failure, irrespective of the intended goal of therapy. The trial's 2-year clinical outcome (n=366) demonstrated superiority of the HM3 for the primary end point (survival free of a disabling stroke or reoperation to replace or remove a malfunctioning pump). This analysis evaluates health resource use and cost implications of the observed differences between the 2 devices while patients were enrolled in the trial. METHODS: We analyzed all hospitalizations and their associated costs occurring after discharge from the implant hospitalization until censoring (study withdrawal, heart transplantation, and pump exchange with a nonstudy device or death). Each adjudicated episode of hospital-based care was used to calculate costs (device-attributable and non-device-attributable event costs), estimated by using trial data and payer administrative claims databases. Cost savings stratified by subgroups (study outcome [transplant, death, or ongoing on device], intended goal of therapy, type of insurance, or sex) were also assessed. RESULTS: In 366 randomly assigned patients, 361 comprised the as-treated group (189 in the HM3 group and 172 in the HMII group), of whom 337 (177 in the HM3 group and 160 in the HMII group) were successfully discharged following implantation. The HM3 arm experienced fewer total hospitalizations per patient-year (HM3: 2.1±0.2 versus HMII: 2.7±0.2; P=0.015) and 8.3 fewer hospital days per patient-year on average (HM3: 17.1 days versus HMII: 25.5 days; P=0.003). These differences were driven by patients hospitalized for suspected pump thrombosis (HM3: 0.6% versus HMII: 12.5%; P<0.001) and stroke (HM3: 2.8% versus HMII: 11.3%; P=0.002). Controlled for time spent in the study (average cumulative cost per patient-year), postdischarge HM3 arm costs were 51% lower than with the HMII (HM3: $37 685±4251 versus HMII: $76 599±11 889, P<0.001) and similar in either bridge to transplant or destination therapy intent. CONCLUSIONS: In this 2-year outcome economic analysis of the MOMENTUM 3 trial, the HM3 demonstrated a reduction in rehospitalizations, hospital days spent during rehospitalizations, and a significant cost savings following discharge in comparison with the HMII left ventricular assist system, irrespective of the intended goal of therapy. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02224755.


Assuntos
Atenção à Saúde/economia , Insuficiência Cardíaca/terapia , Coração Auxiliar/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Custos e Análise de Custo , Feminino , Insuficiência Cardíaca/economia , Insuficiência Cardíaca/patologia , Transplante de Coração , Coração Auxiliar/efeitos adversos , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Trombose/etiologia , Resultado do Tratamento , Adulto Jovem
5.
Eur Heart J ; 39(37): 3454-3460, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30165521

RESUMO

Aims: The ELEVATE registry was planned to study post-approval outcomes with HeartMate 3™ (HM3), a fully magnetically levitated continuous flow left ventricular assist device (LVAD). Methods and results: A total of 482 patients provided consent to participate in ELEVATE (enrolled cohort). Data collection included baseline demographics, survival, adverse events, quality of life (QOL) [EuroQoL-5 Dimensions visual analogue scale (VAS), and 6-minute walk distance (6MWD)]. An additional 58 patients were implanted with HM3 during the same period but expired or were explanted prior to consent, and only survival data were collected (anonymized cohort). We report the 6-month outcomes of the patients who received HM3 as their primary implant (n = 463) and the survival of the 540 patients in the full cohort (enrolled + anonymized). Baseline characteristics included a mean age of 55.6 ± 11.7 years, 89% male, 48% ischaemic aetiology, and 70% on inotropes. The majority of patients (66%) were bridge-to-transplantation (BTT) and 32% were INTERMACS profile 1-2. Full cohort survival at 6 months was 82 ± 2%. In the enrolled primary implant patients, there was no incidence of pump thrombosis, major bleeding was 25%, major infection 35%, and any stroke type 5%. Functional capacity improved significantly (Δ6MWD 230 ± 191 m) as did QOL (ΔVAS 31 ± 23). Freedom from unplanned rehospitalizations at 6 months was 68 ± 2%. Conclusion: The 6-month outcomes of the HM3 LVAD demonstrate a highly reliable, thrombosis free, device with low incidence of stroke and improved functional capacity, and QOL. ClinicalTrials. gov Identifier: NCT02497950.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Idoso , Feminino , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Coração Auxiliar/efeitos adversos , Coração Auxiliar/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
6.
Hum Mol Genet ; 23(5): 1134-50, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24108106

RESUMO

Arrhythmogenic right ventricular cardiomyopathy (ARVC) termed a 'disease of the desmosome' is an inherited cardiomyopathy that recently underwent reclassification owing to the identification of left-dominant and biventricular disease forms. Homozygous loss-of-function mutations in the desmosomal component, desmoplakin, are found in patients exhibiting a biventricular form of ARVC; however, no models recapitulate the postnatal hallmarks of the disease as seen in these patients. To gain insights into the homozygous loss-of-function effects of desmoplakin in the heart, we generated cardiomyocyte-specific desmoplakin-deficient mice (DSP-cKO) using ventricular myosin light chain-2-Cre mice. Homozygous DSP-cKO mice are viable but display early ultrastructural defects in desmosomal integrity leading to a cardiomyopathy reminiscent of a biventricular form of ARVC, which includes cell death and fibro-fatty replacement within the ventricle leading to biventricular dysfunction, failure and premature death. DSP-cKO mice also exhibited ventricular arrhythmias that are exacerbated with exercise and catecholamine stimulation. Furthermore, DSP-cKO hearts exhibited right ventricular conduction defects associated with loss of connexin 40 expression and electrical wavefront propagation defects associated with loss of connexin 43 expression. Dose-dependent assessment of the effects of loss of desmoplakin in neonatal ventricular cardiomyocytes revealed primary loss of connexin 43 levels, phosphorylation and function independent of the molecular dissociation of the mechanical junction complex and fibro-fatty manifestation associated with ARVC, suggesting a role for desmoplakin as a primary stabilizer of connexin integrity. In summary, we provide evidence for a novel mouse model, which is reminiscent of the postnatal onset of ARVC while highlighting mechanisms underlying a biventricular form of human ARVC.


Assuntos
Displasia Arritmogênica Ventricular Direita/genética , Conexinas/deficiência , Animais , Animais Recém-Nascidos , Arritmias Cardíacas/genética , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/mortalidade , Síndrome de Brugada , Doença do Sistema de Condução Cardíaco , Catecolaminas/farmacologia , Conexina 43/deficiência , Conexina 43/genética , Conexina 43/metabolismo , Conexinas/genética , Desmoplaquinas/deficiência , Modelos Animais de Doenças , Eletrocardiografia , Expressão Gênica , Coração/efeitos dos fármacos , Sistema de Condução Cardíaco/anormalidades , Imageamento por Ressonância Magnética , Camundongos , Camundongos Knockout , Miocárdio/metabolismo , Miocárdio/patologia , Miocárdio/ultraestrutura , Miócitos Cardíacos/efeitos dos fármacos , Miócitos Cardíacos/metabolismo , Miócitos Cardíacos/patologia , Miócitos Cardíacos/ultraestrutura , Fosforilação , Condicionamento Físico Animal/efeitos adversos , Proteína alfa-5 de Junções Comunicantes
7.
Artigo em Inglês | MEDLINE | ID: mdl-38669474

RESUMO

Background and Aim: Glucagon-like peptide-1 receptor agonists (GLP-1 RA) therapy provides glycemic benefits to individuals with type 2 diabetes (T2D). However, the effects of GLP-1 RA therapy in combination with FreeStyle Libre systems (FSL) are unknown. This study aimed to compare changes in hemoglobin A1c (HbA1c) between people acquiring GLP-1 with FSL (GLP-1+FSL) versus GLP-1 without FSL (GLP-1). Methods: This real-world study used Optum's de-identified Market Clarity Data, a linked electronic health records (EHR)-claims database, and included adults with T2D and HbA1c ≥8% who acquired their first GLP-1 RA medication between 2018 and 2022. GLP-1+FSL subjects acquired their first FSL within ±30 days of their first GLP-1 acquisition. Cohorts were matched 1:5 on baseline insulin therapy, age, sex, baseline HbA1c, and GLP-1 type. Paired changes in HbA1c were compared between unmatched and matched groups at 6 months. Results: The study included 24,724 adults in the unmatched cohort (GLP-1+FSL, n = 478; GLP-1, n = 24,246). The matched cohort included 478 GLP-1+FSL users and 2,390 GLP-1 users: mean age 53.5 ± 11.8 and 53.5 ± 11.3 years, HbA1c 10.25 ± 1.68% and 10.22 ± 1.69%, respectively. HbA1c reduction was greater in the GLP-1+FSL group compared with the GLP-1 group in the unmatched cohort (-2.43% vs. -1.73%, difference 0.70%, P < 0.001, respectively) and in the matched cohort (-2.43% vs. -2.06%, difference 0.37%, P < 0.001). GLP-1+FSL vs. GLP-1 treatment was associated with greater HbA1c reduction in the intensive insulin (-2.32% vs. -1.50%), nonintensive insulin (-2.50% vs. -1.74%), and noninsulin group (-2.46% vs. -1.78%), as well as in patients using semaglutide (-2.73% vs. -1.92%) and dulaglutide (-2.45% vs. -1.71%) GLP-1 RA, all P < 0.001. Conclusions: Adults with suboptimally controlled T2D, initiating GLP-1 RA with FreeStyle Libre, had greater improvement in HbA1c compared with those treated with GLP-1 RA only. These results suggest an additional glycemic benefit of FSL when used with a GLP-1 RA in T2D treatment.

8.
Biophys J ; 104(7): 1623-33, 2013 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-23561539

RESUMO

Vinculin (Vcl) plays a key structural role in ventricular myocytes that, when disrupted, can lead to contractile dysfunction and dilated cardiomyopathy. To investigate the role of Vcl in myocyte and myocardial function, cardiomyocyte-specific Vcl knockout mice (cVclKO) and littermate control wild-type mice were studied with transmission electron microscopy (TEM) and in vivo magnetic resonance imaging (MRI) tagging before the onset of global ventricular dysfunction. MRI revealed significantly decreased systolic strains transverse to the myofiber axis in vivo, but no changes along the muscle fibers or in fiber tension in papillary muscles from heterozygous global Vcl null mice. Myofilament lattice spacing from TEM was significantly greater in cVclKO versus wild-type hearts fixed in the unloaded state. AFM in Vcl heterozygous null mouse myocytes showed a significant decrease in membrane cortical stiffness. A multiscale computational model of ventricular mechanics incorporating cross-bridge geometry and lattice mechanics showed that increased transverse systolic stiffness due to increased lattice spacing may explain the systolic wall strains associated with Vcl deficiency, before the onset of ventricular dysfunction. Loss of cardiac myocyte Vcl may decrease systolic transverse strains in vivo by decreasing membrane cortical tension, which decreases transverse compression of the lattice thereby increasing interfilament spacing and stress transverse to the myofibers.


Assuntos
Ventrículos do Coração/citologia , Ventrículos do Coração/fisiopatologia , Fenômenos Mecânicos , Miócitos Cardíacos/metabolismo , Disfunção Ventricular/metabolismo , Vinculina/metabolismo , Animais , Fenômenos Biomecânicos , Adesão Celular , Membrana Celular/metabolismo , Técnicas de Inativação de Genes , Ventrículos do Coração/patologia , Camundongos , Modelos Moleculares , Conformação Molecular , Miócitos Cardíacos/citologia , Miócitos Cardíacos/patologia , Sarcômeros/metabolismo , Sarcômeros/patologia , Estresse Mecânico , Disfunção Ventricular/patologia , Vinculina/deficiência , Vinculina/genética
9.
Circulation ; 126(22): 2575-88, 2012 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-23095280

RESUMO

BACKGROUND: Cardiac hypertrophy is a common response to circulatory or neurohumoral stressors as a mechanism to augment contractility. When the heart is under sustained stress, the hypertrophic response can evolve into decompensated heart failure, although the mechanism(s) underlying this transition remain largely unknown. Because phosphorylation of cardiac myosin light chain 2 (MLC2v), bound to myosin at the head-rod junction, facilitates actin-myosin interactions and enhances contractility, we hypothesized that phosphorylation of MLC2v plays a role in the adaptation of the heart to stress. We previously identified an enzyme that predominantly phosphorylates MLC2v in cardiomyocytes, cardiac myosin light-chain kinase (cMLCK), yet the role(s) played by cMLCK in regulating cardiac function in health and disease remain to be determined. METHODS AND RESULTS: We found that pressure overload induced by transaortic constriction in wild-type mice reduced phosphorylated MLC2v levels by ≈40% and cMLCK levels by ≈85%. To examine how a reduction in cMLCK and the corresponding reduction in phosphorylated MLC2v affect function, we generated Mylk3 gene-targeted mice and transgenic mice overexpressing cMLCK specifically in cardiomyocytes. Pressure overload led to severe heart failure in cMLCK knockout mice but not in mice with cMLCK overexpression in which cMLCK protein synthesis exceeded degradation. The reduction in cMLCK protein during pressure overload was attenuated by inhibition of ubiquitin-proteasome protein degradation systems. CONCLUSIONS: Our results suggest the novel idea that accelerated cMLCK protein turnover by the ubiquitin-proteasome system underlies the transition from compensated hypertrophy to decompensated heart failure as a result of reduced phosphorylation of MLC2v.


Assuntos
Adaptação Fisiológica/fisiologia , Miosinas Cardíacas/metabolismo , Cardiomegalia/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Contração Miocárdica/fisiologia , Cadeias Leves de Miosina/metabolismo , Estresse Fisiológico/fisiologia , Animais , Aorta/fisiopatologia , Miosinas Cardíacas/genética , Modelos Animais de Doenças , Progressão da Doença , Feminino , Masculino , Camundongos , Camundongos da Linhagem 129 , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Cadeias Leves de Miosina/genética , Quinase de Cadeia Leve de Miosina/genética , Quinase de Cadeia Leve de Miosina/metabolismo , Fosforilação/fisiologia , Complexo de Endopeptidases do Proteassoma/metabolismo , Ubiquitina/metabolismo , Pressão Ventricular/fisiologia
10.
Ann Thorac Surg ; 114(6): 2262-2269, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35452663

RESUMO

BACKGROUND: Outcomes in patients with smaller body size after HeartMate 3 left ventricular assist device (HM3) implantation are not well characterized. We sought to evaluate outcomes in smaller vs larger body surface area (BSA) patients in the MOMENTUM 3 pivotal trial and its Continued Access Protocol cohort. METHODS: The analysis cohort included 1015 HM3 patients divided into 2 groups: BSA ≤1.70 m2 (small patients, n = 82) and BSA >1.70 m2 (large patients, n = 933). The composite primary end point was survival at 2 years free of disabling stroke or reoperation to replace or to remove a malfunctioning device. Adverse events were compared between groups. RESULTS: Smaller patients were more frequently women (56.1% vs 17.7%; P < .001) and had lower prevalence of diabetes (28.1% vs 43.9%; P = .005) and hypertension (51.2% vs 71.9%; P < .001), larger median indexed LVEDD (normalized by BSA, 40 vs 33 mm/m2; P < .001), and lower median serum creatinine concentration (1.1 vs 1.3 mg/dL; P < .001). The proportion of patients achieving the composite end point at 2 years was 77% in both groups (adjusted hazard ratio, 1.14; 95% CI, 0.68-1.91; P = .62). Two-year adverse event rates were also similar between groups except for sepsis (6.1% vs 14.9%; P = .029) and cardiac arrhythmias (24.4% vs 35.3%; P = .005), which were higher in the larger patients. CONCLUSIONS: Outcomes after HM3 implantation were comparable between small and large patients. Smaller body size should not be used to deny HM3 implantation in patients who are otherwise suitable candidates for durable mechanical circulatory support.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Adulto , Feminino , Humanos , Tamanho Corporal , Insuficiência Cardíaca/etiologia , Coração Auxiliar/efeitos adversos , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
11.
JACC Heart Fail ; 10(12): 948-959, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36456068

RESUMO

BACKGROUND: Clinical trials inform on average efficacy, but individualized risk assessments for outcome prediction are important in guiding treatment implementation. OBJECTIVES: The authors developed and validated a patient-specific risk score to predict survival at 1 and 2 years after HeartMate 3 (HM3) left ventricular assist device (LVAD) implantation. METHODS: The MOMENTUM 3 (Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy with HeartMate 3) trial includes 2,200 HM3 LVAD patients in the pivotal trial and Continued Access Protocol study (2014-2018). The authors randomly assigned all patients to a derivation cohort (n = 1,540) or validation cohort (n = 660). Univariate mortality predictors were screened for potential model inclusion, stepwise selection was used to build the multivariable Cox proportional hazards regression model, and performance (discrimination and calibration) was evaluated. RESULTS: Age, prior cardiac surgery (coronary artery bypass grafting [CABG] or valve procedure), lower serum sodium, higher blood urea nitrogen (BUN), small left ventricular size, and right atrial pressure-to-pulmonary capillary wedge pressure (RAP/PCWP) ratio >0.6 were significant risk factors for mortality. Receiver-operating characteristic (ROC) analysis in the validation cohort demonstrated an area under the curve (AUC) of 0.76 (95% CI: 0.70-0.81) at 1 year and 0.71 (95% CI: 0.66-0.77) at 2 years. Calibration between predicted and observed survival of the risk quintiles was high, with Pearson correlation coefficients of 0.986 and 0.994 at 1 and 2 years, respectively. Patients were successfully stratified into tertiles with higher-than-average, average, and lower-than-average survival, and observed mortality risk increased by 2-fold from one tertile to the next. CONCLUSIONS: A practical, easy-to-use HM3 Survival Risk Score with 6 components was developed to accurately predict 1- and 2-year survival after HM3 LVAD implantation. The survival risk score can be used to provide individual survival estimates to facilitate shared decision making when considering HM3 LVAD therapy. (MOMENTUM 3 Trial Portfolio; NCT02224755, NCT02892955).


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Humanos , Insuficiência Cardíaca/terapia , Fatores de Risco , Pressão Propulsora Pulmonar , Medição de Risco
12.
Eur J Heart Fail ; 23(8): 1392-1400, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33932272

RESUMO

AIM: The MOMENTUM 3 pivotal trial established superiority of the HeartMate 3 (HM3) left ventricular assist device (LVAD), a fully magnetically levitated centrifugal-flow pump, over the HeartMate II axial-flow pump. We now evaluate HM3 LVAD outcomes in a single-arm prospective continuous access protocol (CAP) post-pivotal trial study. METHODS AND RESULTS: We enrolled 2200 HM3 implanted patients (515 pivotal trial and 1685 CAP patients) and compared outcomes including survival free of disabling stroke or reoperation to replace or remove a malfunctioning device (primary composite endpoint), overall survival and major adverse events at 2 years. The 2-year primary endpoint [76.7% vs. 74.8%; adjusted hazard ratio (HR) 0.87, 95% confidence interval (CI) 0.71-1.08, P = 0.21] and overall survival (81.2% vs. 79.0%) were similar among CAP and pivotal cohorts despite sicker patients (more intra-aortic balloon pump use and INTERMACS profile 1) in CAP who were more often intended for destination therapy. Survival was similar between the CAP and pivotal trial in transplant ineligible patients (79.1% vs. 76.7%; adjusted HR 0.89, 95% CI 0.68-1.16, P = 0.38). In a pooled analysis, the 2-year primary endpoint was similar between INTERMACS profiles 1-2 ('unstable' advanced heart failure), profile 3 ('stable' on inotropic therapy), and profiles 4-7 ('stable' ambulatory advanced heart failure) (75.7% vs. 77.6% vs. 72.9%, respectively). The net burden of adverse events was lower in CAP (adjusted rate ratio 0.93, 95% CI 0.88-0.98, P = 0.006), with consequent decrease in hospitalization. CONCLUSIONS: The primary results of accumulating HM3 LVAD experience suggest a lower adverse event burden and similar survival compared to the pivotal MOMENTUM 3 trial.


Assuntos
Insuficiência Cardíaca , Coração Auxiliar , Acidente Vascular Cerebral , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
13.
Magn Reson Med ; 64(5): 1281-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20981782

RESUMO

A model-based method for calculating three-dimensional (3D) cardiac wall strain distributions in the mouse has been developed and tested in a genetically engineered mouse model of dilated cardiomyopathy. Data from MR tagging and harmonic phase (HARP) tracking were used to measure material point displacements, and 3D Lagrangian strains were calculated throughout the entire left ventricle (LV) with a deformable parametric model. A mouse model where cardiomyocytes are specifically made deficient in vinculin (VclKO) were compared to wild-type (WT) littermates. 3D strain analysis revealed differences in LV wall mechanics between WT and VclKO mice at 8 weeks of age when systolic function had just begun to decline. Most notably, end-systolic radial strain and torsional shear were reduced in VclKO hearts which contributed to regional mechanical dysfunction. This study demonstrates the feasibility of using MRI tagging methods to detect alterations in 3D myocardial strain distributions in genetically engineered mouse models of cardiovascular disease.


Assuntos
Cardiomiopatia Dilatada/diagnóstico , Cardiomiopatia Dilatada/fisiopatologia , Modelos Animais de Doenças , Técnicas de Imagem por Elasticidade/métodos , Ventrículos do Coração/fisiopatologia , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/fisiopatologia , Animais , Cardiomiopatia Dilatada/complicações , Módulo de Elasticidade , Marcação de Genes , Camundongos , Camundongos Knockout , Camundongos Transgênicos , Coloração e Rotulagem/métodos , Estresse Mecânico , Disfunção Ventricular Esquerda/etiologia , Vinculina/genética
14.
J Heart Lung Transplant ; 39(6): 529-537, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32279919

RESUMO

BACKGROUND: Mitral regurgitation (MR) determines pathophysiology and outcome in advanced heart failure. The impact of left ventricular assist device (LVAD) placement on clinically significant MR and its contribution to long-term outcomes has been sparsely evaluated. METHODS: We evaluated the effect of clinically significant MR on patients implanted in the MOMENTUM 3 trial with either the HeartMate II (HMII) or the HeartMate 3 (HM3) at 2 years. Clinical significance was defined as moderate or severe grade MR determined by site-based echocardiograms. RESULTS: Of 927 patients with LVAD implants without a prior or concomitant mitral valve procedure, 403 (43.5%) had clinically significant MR at baseline. At 1-month of support, residual MR was present in 6.2% of patients with HM3 and 14.3% of patients with HMII (relative risk = 0.43; 95% CI, 0.22-0.84; p = 0.01) with a low rate of worsening at 2 years. Residual MR at 1-month post-implant did not impact 2-year mortality for either the HM3 (hazard ratio [HR],1.41; 95% CI, 0.52-3.89; p = 0.50) or HMII (HR, 0.91; 95% CI, 0.37-2.26; p = 0.84) LVAD. The presence or absence of baseline MR did not influence mortality (HM3 HR, 0.86; 95% CI, 0.56-1.33; p = 0.50; HMII HR, 0.81; 95% CI, 0.54-1.22; p = 0.32), major adverse events or functional capacity. In multivariate analysis, severe baseline MR (p = 0.001), larger left ventricular dimension (p = 0.002), and implantation with the HMII instead of the HM3 LVAD (p = 0.05) were independently associated with an increased likelihood of persistent MR post-implant. CONCLUSIONS: Hemodynamic unloading after LVAD implantation improves clinically significant MR early, sustainably, and to a greater extent with the HM3 LVAD. Neither baseline nor residual MR influence outcomes after LVAD implantation.


Assuntos
Insuficiência Cardíaca/terapia , Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Ecocardiografia , Feminino , Seguimentos , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico , Estudos Retrospectivos , Resultado do Tratamento
15.
Ann Thorac Surg ; 107(1): 33-39, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30291831

RESUMO

BACKGROUND: The HeartMate 3 left ventricular assist device (Abbott, Chicago, IL) is designed to provide circulatory support with enhanced hemocompatibility for patients with advanced heart failure. The purpose of this study was to compare the surgical outcomes between patients treated during the European Conformity Mark (CE Mark [CEM]) clinical trial and those treated in the postmarket era. METHODS: The prospective, observational, multinational ELEVATE (Evaluating the HeartMate 3 with Full MagLev Technology in a Post-Market Approval Setting) registry includes patients receiving the HeartMate 3 following CEM approval. Outcomes of patients in the ELEVATE registry are compared with patients in the CEM trial. RESULTS: Compared with the CEM trial (N = 50), the ELEVATE registry group (N = 463) was more severely ill, with more patients classified as INTERMACS (Interagency Registry for Mechanically Assisted Circulatory Support) profile 1 to 2 (32% versus 10%; p < 0.001). The CEM trial group was younger and underwent fewer concomitant valve procedures. After adjustment for differences in baseline characteristics, the 30-day survival was comparable between the ELEVATE registry and CEM trial groups (95% versus 98%; p = 0.46). Length of intensive care unit stay was similar between the ELEVATE registry (7 days) and CEM trial (6 days) groups. Most adverse event rates were comparable between the 2 groups. ELEVATE registry patients had a lower rate of cardiac arrhythmias (13% versus 28%; p = 0.009). With increasing experience, the implant technique has evolved to include more versatile approaches such as less invasive and off-pump implantation. CONCLUSIONS: The 30-day outcomes for ELEVATE registry patients are comparable despite being sicker than CEM trial patients. Adverse event rates remain low, with no cases of pump thrombosis within the first 30 days. Implant techniques have evolved to include more versatile approaches.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Sistema de Registros , Adulto , Idoso , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Vigilância de Produtos Comercializados , Estudos Prospectivos , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
16.
ASAIO J ; 65(3): 227-232, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-29952801

RESUMO

The PREVENtion of HeartMate II pump Thrombosis through clinical management (PREVENT) study was a multicenter, prospective investigation to evaluate the rate of pump thrombosis (PT) with adoption of a uniform set of surgical and medical practices for left ventricular assist device implantation. We sought to quantify pump position at baseline and retrospectively define a pump position associated with poor clinical outcomes. Chest x-rays at baseline were prospectively obtained per protocol. Pump pocket depth, inflow cannula (IC) angle relative to the pump, and IC angle relative to the vertical were measured. Pumps falling in the tail-ends of the IC angle and pump pocket depth distributions were categorized as having an extreme pump position within the PREVENT study. Patients with extreme pump position had a significantly higher risk of confirmed and suspected PT, hemolysis, and elevated lactate dehydrogenase. In a multivariable analysis of survival free of confirmed PT, extreme pump position was an independent risk factor (hazard ratio = 3.6; 95% confidence interval = 1.5-8.9; p = 0.006) when adjusting for differences in pump speed and anticoagulation level. Our analysis shows that HeartMate II pump position at implant can significantly impact event-free survival and the incidence of adverse events at 6 months.


Assuntos
Coração Auxiliar/efeitos adversos , Trombose/etiologia , Idoso , Procedimentos Cirúrgicos Cardíacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
17.
J Heart Lung Transplant ; 37(6): 706-714, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29275844

RESUMO

BACKGROUND: The ROADMAP study showed survival with improved functional status was better with left ventricular assist device (LVAD) therapy compared with optimal medical management (OMM) in ambulatory, non-inotrope-dependent (INTERMACS [IM] Profile 4 to 7) patients. To study more balanced cohorts and better define which patients may benefit from implantation of an LVAD, we re-evaluated the patients enrolled in ROADMAP when stratified by INTERMACS profile (Profile 4 and Profiles 5 to 7). METHODS: The primary end-point (survival on original therapy with improvement in 6-minute walk distance ≥75 meters at 1 year), actuarial survival, adverse events (AEs) and health-related quality of life (HRQoL) were evaluated. RESULTS: For INTERMACS Profile 4 (IM4), more LVAD patients met the primary end-point compared with OMM patients (40% vs 15%; odds ratio = 3.9 [1.2 to 12.7], p = 0.024), but there was no statistically significant difference for INTERMACS Profiles IM 5 to 7 (IM5-7). Event-free survival on original therapy at 2 years was greater for LVAD than for OMM patients in both IM4 (67% vs 28%; p < 0.001) and IM5-7 (76% vs 49%; p = 0.025) profile groups. Composite end-points of survival on original therapy with improved HRQoL or depression were better with LVAD than OMM in IM4, but not IM5-7. AEs trended higher in LVAD compared with OMM patients in both profile groups. Rehospitalization rates for LVAD vs OMM were similar between treatment arms in IM4 (82% vs 86%; p = 0.780), but were higher for LVAD in IM5-7 (93% vs 71%; p = 0.016). CONCLUSIONS: LVAD patients in IM4, but not IM5-7, are more likely to meet the primary end-point and have improvements in HRQoL and depression compared with OMM, even with AEs generally being more frequent. LVAD therapy with current technology may be beneficial in select IM4 patients, but can be deferred for most IM5-7 patients, who should be followed closely due to the high frequency of treatment failures.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Idoso , Feminino , Insuficiência Cardíaca/classificação , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Taxa de Sobrevida , Resultado do Tratamento , Teste de Caminhada
18.
ASAIO J ; 64(2): 154-158, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-28746083

RESUMO

Optimal function of left ventricular assist devices (LVADs) depends on proper alignment of the inflow cannula (IC). Quantitative guidelines for IC angulation are lacking because of variation in cardiac geometry and difficulty in analyzing three-dimensional (3D) cannula orientation relative to the left ventricle (LV). Based on contrast-enhanced computed tomography images from five normal and five clinically malpositioned IC cases in patients with HeartMate II LVADs, we developed a method for 3D quantification of IC malpositioning. Using Mimics image software (Materialise, Leuven, Belgium), the native heart, major arteries, and LVAD were segmented to create patient-specific 3D models, allowing LV cavity volume and long-axis length to be measured directly. The deviation of the IC was quantified in a cylindrical coordinate system at the IC insertion point relative to the mitral valve and septum, and IC occlusion was assessed by the distance between cannula inlet and the proximal endocardium. Compared with normal cases, patients with malpositioned pumps had shorter LV length (p = 0.03) and reduced pump pocket depth (p = 0.009). Malpositioned pumps may experience greater obstruction by the nearby myocardium. This quantitative 3D modeling tool may help identify different modes of pump malalignment and migration and may facilitate preoperative planning and minimally invasive approaches via virtual LVAD implantation.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Coração Auxiliar , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia Computadorizada por Raios X/métodos , Cânula , Humanos , Masculino
19.
J Heart Lung Transplant ; 37(1): 25-32, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29153636

RESUMO

BACKGROUND: Hemolysis, assessed by elevated serum lactate dehydrogenase (LDH), is strongly associated with HeartMate II pump thrombosis (PT). However, it is unknown whether early intervention for elevated LDH circumvents the risk of serious PT requiring pump exchange. We sought to evaluate the relationship between elevated LDH and clinical outcomes, the effectiveness of early medical intervention, and risk factors for elevated LDH. METHODS: We studied 268 patients in the prospective, multicenter PREVENT study who had 2 or more LDH measurements at ≥30 days post-implant. Elevated LDH was defined as LDH ≥2.5× upper limit of normal (ULN) for 2 consecutive measurements. RESULTS: Fourteen percent of patients had elevated LDH. Stroke-free survival at 6 months was lower in patients with elevated LDH vs patients with normal LDH (83 ± 6% vs 93 ± 2%, p = 0.035). Elevated LDH resolved without intervention in 19% of patients, with intensified medical therapy in 43% and required surgical intervention in 38%. For patients receiving only medical therapy, survival was 94 ± 6% at 6 months post-treatment. In this subgroup, resolution of symptoms with intensified medical therapy was sustained in 15 of 16 patients, with PT occurring in 1 patient at 171 days after initial treatment for elevated LDH (202 days post-implant). Early medical intervention at moderately elevated LDH (2.5× to 3.2× ULN), as compared with higher levels (>3.2× ULN), led to more sustained resolution of symptoms without subsequent PT or need for surgical intervention (91% vs 26% at 6 months post-treatment, p = 0.002). CONCLUSIONS: Early medical intervention can successfully resolve moderate LDH elevations (2.5× to 3.2× ULN) with a low incidence of death or PT at 6 months post-treatment.


Assuntos
Intervenção Médica Precoce , Coração Auxiliar/efeitos adversos , Hemólise , L-Lactato Desidrogenase/sangue , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Trombose/etiologia , Trombose/prevenção & controle , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Fatores de Risco , Trombose/epidemiologia , Fatores de Tempo , Resultado do Tratamento
20.
Circ Heart Fail ; 10(5)2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28465311

RESUMO

BACKGROUND: Timing of left ventricular assist device (LVAD) implantation in advanced heart failure patients not on inotropes is unclear. Relevant prediction models exist (SHFM [Seattle Heart Failure Model] and HMRS [HeartMate II Risk Score]), but use in this group is not established. METHODS AND RESULTS: ROADMAP (Risk Assessment and Comparative Effectiveness of Left Ventricular Assist Device and Medical Management in Ambulatory Heart Failure Patients) is a prospective, multicenter, nonrandomized study of 200 advanced heart failure patients not on inotropes who met indications for LVAD implantation, comparing the effectiveness of HeartMate II support versus optimal medical management. We compared SHFM-predicted versus observed survival (overall survival and LVAD-free survival) in the optimal medical management arm (n=103) and HMRS-predicted versus observed survival in all LVAD patients (n=111) using Cox modeling, receiver-operator characteristic (ROC) curves, and calibration plots. In the optimal medical management cohort, the SHFM was a significant predictor of survival (hazard ratio=2.98; P<0.001; ROC area under the curve=0.71; P<0.001) but not LVAD-free survival (hazard ratio=1.41; P=0.097; ROC area under the curve=0.56; P=0.314). SHFM showed adequate calibration for survival but overestimated LVAD-free survival. In the LVAD cohort, the HMRS had marginal discrimination at 3 (Cox P=0.23; ROC area under the curve=0.71; P=0.026) and 12 months (Cox P=0.036; ROC area under the curve=0.62; P=0.122), but calibration was poor, underestimating survival across time and risk subgroups. CONCLUSIONS: In non-inotrope-dependent advanced heart failure patients receiving optimal medical management, the SHFM was predictive of overall survival but underestimated the risk of clinical worsening and LVAD implantation. Among LVAD patients, the HMRS had marginal discrimination and underestimated survival post-LVAD implantation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01452802.


Assuntos
Gerenciamento Clínico , Insuficiência Cardíaca/terapia , Coração Auxiliar , Pacientes Ambulatoriais , Medição de Risco/métodos , Idoso , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Ventrículos do Coração , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Fatores de Risco , Taxa de Sobrevida/tendências , Resultado do Tratamento , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA