Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
Intervalo de ano de publicação
1.
Opt Lett ; 39(16): 4747-50, 2014 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-25121864

RESUMO

We report the fabrication and first demonstration of an electron beam position monitor for a dielectric microaccelerator. This device is fabricated on a fused silica substrate using standard optical lithography techniques and uses the radiated optical wavelength to measure the electron beam position with a resolution of 10 µm, or 7% of the electron beam spot size. This device also measures the electron beam spot size in one dimension.

2.
Med Phys ; 50(3): e53-e61, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36705550

RESUMO

Over several months, representatives from the U.S. Department of Energy (DOE) Office of Science and National Institutes of Health (NIH) had a number of meetings that lead to the conclusion that innovations in the Nation's health care could be realized by more directed interactions between NIH and DOE. It became clear that the expertise amassed and instrumentation advances developed at the DOE physical science laboratories to enable cutting-edge research in particle physics could also feed innovation in medical healthcare. To meet their scientific mission, the DOE laboratories created advances in such technologies as particle beam generation, radioisotope production, high-energy particle detection and imaging, superconducting particle accelerators, superconducting magnets, cryogenics, high-speed electronics, artificial intelligence, and big data. To move forward, NIH and DOE initiated the process of convening a joint workshop which occurred on July 12th and 13th, 2021. This Special Report presents a summary of the findings of the collaborative workshop and introduces the goals of the next one.


Assuntos
Pesquisa Biomédica , Disciplinas das Ciências Naturais , Estados Unidos , Inteligência Artificial , National Institutes of Health (U.S.) , Laboratórios
3.
Opt Express ; 20(5): 5607-12, 2012 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-22418367

RESUMO

The quest for less costly and more compact high-energy particle accelerators makes research on alternative acceleration mechanisms an important enterprise. From the multitude of suggested concepts, the photonic accelerator design by B. M. Cowan [Phys. Rev. ST Accel. Beams 11, 011301 (2008)] stands out by its distinct potential of creating an accelerator on a chip [Proposal E-163, SLAC (2001)]. Herein, electrons are accelerated by the axial electric field of a strongly confined optical mode of an air waveguide within a silicon-based three-dimensional photonic band-gap material. Using a combination of direct laser writing and silicon double inversion, we here present the first experimental realization of this complex structure. Optical spectroscopy provides unambiguous evidence for the existence of an accelerating waveguide mode with axial polarization.


Assuntos
Lentes , Aceleradores de Partículas/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
4.
Med Phys ; 42(4): 1606-13, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25832051

RESUMO

PURPOSE: To measure radiation dose in a water-equivalent medium from very high-energy electron (VHEE) beams and make comparisons to Monte Carlo (MC) simulation results. METHODS: Dose in a polystyrene phantom delivered by an experimental VHEE beam line was measured with Gafchromic films for three 50 MeV and two 70 MeV Gaussian beams of 4.0-6.9 mm FWHM and compared to corresponding MC-simulated dose distributions. MC dose in the polystyrene phantom was calculated with the EGSnrc/BEAMnrc and DOSXYZnrc codes based on the experimental setup. Additionally, the effect of 2% beam energy measurement uncertainty and possible non-zero beam angular spread on MC dose distributions was evaluated. RESULTS: MC simulated percentage depth dose (PDD) curves agreed with measurements within 4% for all beam sizes at both 50 and 70 MeV VHEE beams. Central axis PDD at 8 cm depth ranged from 14% to 19% for the 5.4-6.9 mm 50 MeV beams and it ranged from 14% to 18% for the 4.0-4.5 mm 70 MeV beams. MC simulated relative beam profiles of regularly shaped Gaussian beams evaluated at depths of 0.64 to 7.46 cm agreed with measurements to within 5%. A 2% beam energy uncertainty and 0.286° beam angular spread corresponded to a maximum 3.0% and 3.8% difference in depth dose curves of the 50 and 70 MeV electron beams, respectively. Absolute dose differences between MC simulations and film measurements of regularly shaped Gaussian beams were between 10% and 42%. CONCLUSIONS: The authors demonstrate that relative dose distributions for VHEE beams of 50-70 MeV can be measured with Gafchromic films and modeled with Monte Carlo simulations to an accuracy of 5%. The reported absolute dose differences likely caused by imperfect beam steering and subsequent charge loss revealed the importance of accurate VHEE beam control and diagnostics.


Assuntos
Simulação por Computador , Elétrons , Dosimetria Fotográfica , Método de Monte Carlo , Imagens de Fantasmas , Doses de Radiação , Poliestirenos , Incerteza , Água
5.
Phys Rev Lett ; 95(19): 194801, 2005 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-16383986

RESUMO

We present the first direct observation of a higher-order inverse-free-electron-laser (IFEL) interaction. Interaction at the fourth, fifth, and sixth harmonics is observed from an IFEL operating at 800 nm. The harmonic spacing, relative harmonic strength, and transverse beam overlap of the interaction are all in good agreement with tracking simulations.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA