Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Graefes Arch Clin Exp Ophthalmol ; 260(8): 2753-2762, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35175409

RESUMO

PURPOSE: To assess the results of partial monovision (PMV) in comparison to a bilateral monofocal implantation (MMV). METHODS: The PMV group was treated bilaterally with a monofocal intraocular lens (IOL) implantation, followed 3 months later by the implantation of a multifocal AddOn® lens (+ 3.00 D) into the non-dominant eye. The MMV group received a bilateral monofocal IOL implantation intending to achieve a slight anisometropia (0.0 D/ - 0.50 D). The near visual acuity (UNVA), intermediate visual acuity (UIVA), distance visual acuity (UDVA), defocus curve, and Lang-Stereotest II were conducted uncorrected, binocular, and minimum 3 months after the last operation. For the contrast sensitivity test, the patients were refractively corrected. The Quality of Vision Questionnaire (QoV), Visual Function Questionnaire (VF-14), spectacle independence, and general satisfaction were also assessed. RESULTS: A total of 27 PMV patients and 28 MMV patients without ocular diseases relevant to visual acuity were examined. The PMV group was significantly better at UNVA (0.11 ± 0.08 logMAR vs 0.56 ± 0.16 logMAR) and between - 2.00 and - 4.00 D in the defocus curve (p < 0.001). At the UIVA, the PMV group was slightly better (0.11 ± 0.10 logMAR vs 0.20 ± 0.18 logMAR) but not significant (p = 0.054). The UDVA (- 0.13 ± 0.09 logMAR vs - 0.09 ± 0.14 logMAR) (p = 0.315) and contrast sensitivity (p = 0.667) revealed no differences between the groups. The stereo vision was in favor of PMV (p = 0.008). Spectacle independence was statistically better for PMV at distance, intermediate, and near (distance p = 0.012; intermediate p < 0.001; near p < 0.001). In the VF-14 Questionnaire, the PMV was statistically superior (p < 0.001). The QoV Questionnaire showed no differences regarding frequency and severity of visual disturbances. Both groups were highly satisfied (p = 0.509). CONCLUSION: Patients with PMV are more independent of glasses and are able to read without disadvantages in distance vision, due to halos and glare. The concept of PMV is well suited for the desire of eyeglass independence, without optical side effects.


Assuntos
Lentes Intraoculares , Facoemulsificação , Óculos , Humanos , Implante de Lente Intraocular/métodos , Satisfação do Paciente , Desenho de Prótese , Pseudofacia , Visão Monocular
2.
Sensors (Basel) ; 22(9)2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35591048

RESUMO

The aim of this study was to develop and evaluate a 3D ultrasound scanning method. The main requirements were the freehand architecture of the scanner and high accuracy of the reconstructions. A quantitative evaluation of a freehand 3D ultrasound scanner prototype was performed, comparing the ultrasonographic reconstructions with the CAD (computer-aided design) model of the scanned object, to determine the accuracy of the result. For six consecutive scans, the 3D ultrasonographic reconstructions were scaled and aligned with the model. The mean distance between the 3D objects ranged between 0.019 and 0.05 mm and the standard deviation between 0.287 mm and 0.565 mm. Despite some inherent limitations of our study, the quantitative evaluation of the 3D ultrasonographic reconstructions showed comparable results to other studies performed on smaller areas of the scanned objects, demonstrating the future potential of the developed prototype.


Assuntos
Imageamento Tridimensional , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Ultrassonografia
3.
J Reconstr Microsurg ; 38(8): 604-612, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35798338

RESUMO

BACKGROUND: Live animals have been used for decades as one of the many training models for developing surgical skills. Microsurgery in particular relies on training for skill acquisition and maintenance, using live animal models, especially rats (murine models). Efforts are underway to reduce the number of rats sacrificed to achieve this objective. METHODS: A group of students with minimal microsurgical experience, after having gone through a basic microsurgical course, were randomly split into three equal groups, all three groups following a 24-week standard training program based on low- and medium-fidelity training models with standardized murine training days. In addition to the standard training regimen, each participant performed supplementary training on live rats every 4, 6, or 8 weeks. According to the training program, the procedures have been performed on chicken legs, flower petals, and rats, each procedure being blindly assessed and evaluated using validated models and scales. The primary evaluated outcome was the Stanford Microsurgery and Resident Training (SMaRT) scale result of the final rat anastomosis performed by each group, for which the tested hypothesis was one of noninferiority. The secondary outcomes were represented by the final rat anastomosis time, final chicken leg anastomosis result and time, and the final petal score. RESULTS: After the 24th week, no differences were observed between the three groups regarding their microsurgical skills, as measured by the aforementioned surgical outcomes. All participants improved significantly during the study (mean [standard deviation] 19 ± 4 points on the SMaRT scale), with no significant differences between the groups, p < 0.001 for noninferiority. CONCLUSION: A training regimen based on low- and moderate-fidelity models, with the addition of training on a live rat every 8 weeks was noninferior to a training regimen that used a live rat every 6 weeks and also noninferior to a training regimen that used a live rat every 4 weeks.


Assuntos
Anastomose Cirúrgica , Microcirurgia , Anastomose Cirúrgica/educação , Animais , Competência Clínica , Humanos , Microcirurgia/educação , Modelos Animais , Ratos
4.
J Esthet Restor Dent ; 33(5): 795-806, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33866673

RESUMO

OBJECTIVE: To analyze translucency variations among four different contemporary esthetic ceramic systems having different shades and thicknesses. MATERIAL AND METHODS: Ceramic specimens having different shades and translucencies were tested: leucite reinforced glass-ceramic (ECAD), conventional feldspathic ceramic (Noritake), zirconia reinforced lithium silicate glass-ceramic (Suprinity) and hybrid ceramic (Enamic). Specimens of 0.6, 0.9, 1.2, 1.5 and 2.0-mm thickness (n = 3/group, 615 total) were prepared. Translucency (TP) and Relative Translucency (RTP) Parameters were calculated from spectroradiometric color readings. Effects of shade and thickness for a given system were statistically analyzed using MANOVA and Tukey post-hoc multiple comparisons tests. Translucency variations were assessed comparatively with literature-based perceptibility and acceptability thresholds. RESULTS: TP/RTP values of all ceramic materials decreased with increasing thickness. The most translucent specimens were 0.6-mm thick ECAD HT-A3.5 (TP = 31.99) and ECAD HT-C2 (RTP = 23.75), while the least translucent was 2-mm thick Enamic T-3 M2 (TP = 7.27; RTP = 4.79). Thickness and material type significantly influenced translucency (p < 0.001). Noritake and ECAD LT showed similar translucency values, as well as Suprinity HT and ECAD LT. CONCLUSIONS: For ceramic restorations thicker than 0.9-mm, any thickness increase of 0.3-0.5 mm produces a perceptible but clinically acceptable translucency variation. Increases in thickness larger than 0.6-mm will result in an unacceptable translucency shift. Dental practitioners need to recognize key factors that influence translucency of ceramic restorations in order to choose the optimal material, shade, translucency, and thickness suitable for different clinical scenarios. While shade plays a minor role in translucency variation, ceramic type and restoration thickness significantly affect overall translucency.


Assuntos
Porcelana Dentária , Odontólogos , Cerâmica , Cor , Estética Dentária , Humanos , Teste de Materiais , Papel Profissional , Propriedades de Superfície
5.
BMC Oral Health ; 21(1): 75, 2021 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-33596918

RESUMO

BACKGROUND: To assess color compatibility between dental structures (human enamel and dentine) and three different types of ceramic systems. METHODS: Samples (1 and 2 mm-thick) of extracted tooth (containing dentine and enamel areas) and three ceramic systems with different shades and opacities (HT-High Translucent, T-Translucent) were prepared for this study: Vita Suprinity-VS (HT, T; A1, A2, A3, A3.5, B2, C2, D2) (Vita Zahnfabrik); Vita Enamic-VE (HT, T; 1M1, 1M2, 2M2, 3M2) (Vita Zahnfabrik) and Noritake Super Porcelain EX-3-NKT (A1, A2, A3, A3.5, B2, C2, D2) (Kuraray Noritake Dental). Reflectance measurements of all samples were performed over black backgrounds using a non-contact spectroradiometer (SpectraScan PR-670, Photo Research) under a CIE 45°/0° geometry. CIE L*a*b* color parameters were measured and CIELAB/CIEDE2000 color differences (ΔE00/ΔE*ab) and corresponding Coverage Error (CE) of ceramic system for dentine or enamel samples were calculated. Color data was analyzed using one-way ANOVA and post-hoc multiple comparisons tests. CE values were interpreted by comparisons with available 50:50% acceptability color threshold (AT) for dentistry. RESULTS: Statistically significant differences in lightness were found among all ceramic systems and human dentine (p < 0.001), while no significant differences were registered between enamel and VSHT, T and VEHT. 1 mm dentine showed no statistical differences with VST and VSHT for a* coordinate, while 2 mm dentine showed no significant differences (p > 0.05) with VEHT. Thin samples (1 mm) of dentine and enamel showed significant statistical differences (p < 0.05) for b* coordinate with less translucent materials (NKT, VET and VST). For dentine samples, none of the ceramic materials provided a CE lower than AT. VSHT provided the best CE for 1 mm-thick (CE00 = 1.7, CEab = 1.9) and for 2 mm-thick (CE00 = 2.3; CEab = 2.5) enamel samples. CONCLUSIONS: Color coordinates of evaluated esthetic ceramic systems were statistically different from those of human dentine in almost all cases. The evaluated ZrO2 lithium silicate glass-ceramic (VS), with its two levels of translucency, provided lower CE values with human enamel samples while conventional feldspathic ceramic (NKT) and hybrid ceramic systems (VE) demonstrated a better color compatibility with dentin samples.


Assuntos
Cerâmica , Porcelana Dentária , Cor , Humanos , Teste de Materiais
6.
J Esthet Restor Dent ; 31(5): 478-485, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31155848

RESUMO

OBJECTIVES: To assess the effect of material, thickness and glazing upon the color, translucency, and roughness of monolithic zirconia. MATERIALS AND METHODS: Sixty discs (0.8, 1.5, and 2 mm thickness) were fabricated from A1 translucent zirconia (IPS e.max ZirCAD/MT, Katana/HT, Vita YZ/HT, Cercon/HT) and glazed. Roughness (Ra) was assessed with a profilometer and color coordinates were measured with a spectrophotometer on a black, white, and tooth-shaded background before and after glazing. Relative translucency parameter (RTP), color differences (CIEDE2000) and differences in translucencies between materials, before and after glazing were calculated. RTP, Ra, color differences were statistically analyzed using ANOVA. Any significant interaction between factors was further analyzed using Tukey's HSD. RESULTS: RTP values were significantly different between materials (P < .001) and thicknesses (P < .001), with the interaction effect between material type and thickness, also significant (P < .001). However, glazing did not have a significant effect on RTP values (P = .782). Color differences resulted after glazing were significantly different between materials (P < .001), and thicknesses (P < .001) with the interaction effect also significant (P < .001). Glazing influenced roughness, Ra decreasing for all materials (P < .001). CONCLUSIONS: As a result of glazing, only color changes were statistically significant. Translucency varied among brands of precolored monolithic zirconia; the differences increased for greater thicknesses. CLINICAL SIGNIFICANCE: Glazing is an important step in the technological process of ceramic restorations; however, it can influence the final optical appearance of the restoration as color changes could be expected after the application of the glaze.


Assuntos
Porcelana Dentária , Zircônio , Cerâmica , Cor , Materiais Dentários , Teste de Materiais , Propriedades de Superfície
7.
J Prosthet Dent ; 115(4): 475-81, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26548886

RESUMO

STATEMENT OF PROBLEM: For restorations with excellent esthetics, an understanding of the optical properties of human dentin is needed. Little information is available on the translucency and color parameters of dentin and its relationship to tooth type and position. PURPOSE: The purpose of this in vitro study was to investigate the translucency and CIELab color coordinates of human dentin in both anterior (incisors and canines) and posterior teeth (molars) by using spectrophotometric and spectroradiometric assessment methods. MATERIAL AND METHODS: Uniformly thick specimens (2 mm) of midcoronal human dentin were taken from 33 central and lateral incisors, 7 canines, and 33 molars (all maxillary teeth). The CIELab color coordinates were measured with a clinical spectrophotometer (Easyshade Compact) and a noncontact spectroradiometer (SpectraScan PR-704). The translucency parameter (TP) was calculated. Bland-Altman plots and Wilcoxon signed rank tests for paired samples were used to assess the agreement of the 2 measurement techniques. The differences between anterior and posterior dentin specimens regarding color coordinates and the translucency parameter were analyzed using Mann-Whitney-Wilcoxon rank sum tests. RESULTS: Statistically significant differences between spectrophotometric and spectroradiometric measurements of the TP and CIELab color coordinates were found in both groups of dentin specimens (P<.05). TP values of molar dentin specimens were significantly higher than those of the anterior ones, regardless of the assessment method (P<.001). Dentin specimens of the anterior teeth exhibited higher L∗ values but lower a∗ and b∗ values on both black and white backgrounds compared with molar dentin specimens. CONCLUSIONS: The dentin of anterior teeth was found to be lighter but less translucent and less chromatic than in molars, regardless of the assessment method used.


Assuntos
Cor , Dentina/química , Espectrofotometria/métodos , Humanos , Incisivo , Dente Molar
8.
Biomedicines ; 11(7)2023 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-37509604

RESUMO

The goal of the current study was to determine the mechanical proprieties of polymethylmethacrylate (PMMA) and the improved compound, the graphene-based PMMA, with Zn and Ag and to compare the results. Scanning electron microscopy analysis of the samples before and after the mechanical test was conducted. The compression behavior, flexural properties, tensile strength, and shape of the samples were all investigated and compared between the variants of PMMA. Commercially available polymethylmethacrylate was used (Orthocryl®-Dentaurum, Ispringen, Germany) with the salt and pepper technique according to the manufacturer's instructions to produce 20 samples for each mechanical trial with standard cylinders (4 mm diameter × 8 mm length) for compression, parallelepipedal prisms for flexing (2 mm × 2 mm × 25 mm) and flat samples for traction. There was no statistical difference in the mechanical proprieties of the samples evaluated, although there were values that could suggest significance. The graphene-based PMMA demonstrated good mechanical proprieties, like the commercially available PMMA, and appears promising for future clinical use based on its multiple advantages.

9.
Polymers (Basel) ; 15(9)2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-37177171

RESUMO

The aim of this study was to develop a suitable clotrimazole (CLT)-loaded mucoadhesive vaginal gel (CLT-MVG) for topical applications in vaginal candidiasis. Ten CLT-MVG formulations were prepared, consisting of mixtures of acid polyacrylic (Carbopol 940) and polyethene oxides, Sentry Polyox WSRN 1105 or 750, according to an experimental D-optimal design, and CLT was suspended at a ratio of 1%. The prepared CLT-MVG formulations were studied in vitro, and the formulation containing Carbopol 940 0.89% combined with PEO 1105 1.39% was identified with the optimal rheological and in vitro bioadhesion properties, ensuring the prolonged release of CLT, with a similarity factor greater than 50, indicating dissolution profile similarity for three batches of the optimized formulation. This optimized formulation showed a pH in the tolerance range, and an adequate ex vivo mucoadhesion time, while the FT-IR studies revealed no interactions between the excipients and CLT. The microscopic analysis identified a mean particle size of suspended CLT of 5.24 ± 0.57 µm. The in vitro antifungal activity of the optimized formulation was tested on twenty strains of Candida albicans and proved to be better compared to a marketed clotrimazole preparation, showing a greater inhibition effect (p < 0.05). The optimized formulation could be a good candidate for the local treatment of vaginal mycosis.

10.
Biomedicines ; 11(8)2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37626652

RESUMO

Dental 3D-printing technologies, including stereolithography (SLA), polyjet (triple-jetting technology), and fusion deposition modeling, have revolutionized the field of orthodontic occlusal splint manufacturing. Three-dimensional printing is now currently used in many dental fields, such as restorative dentistry, prosthodontics, implantology, and orthodontics. This study aimed to assess the mechanical properties of 3D-printed materials and compare them with the conventional polymethylmethacrylate (PMMA). Compression, flexural, and tensile properties were evaluated and compared between PMMA samples (n = 20) created using the "salt and pepper" technique and digitally designed 3D-printed samples (n = 20). The samples were subjected to scanning electron microscope analysis. Statistical analysis revealed that the control material (PMMA) exhibited a significantly higher Young's modulus of compression and tensile strength (p < 0.05). In the flexural tests, the control samples demonstrated superior load at break results (p < 0.05). However, the 3D-printed samples exhibited significantly higher maximum bending stress at maximum load (MPa) (p < 0.05). Young's modulus of tensile testing (MPa) was statistically significant higher for the control samples, while the 3D-printed samples demonstrated significantly higher values for elongation at break (p < 0.05). These findings indicate that 3D-printed materials are a promising alternative that can be effectively utilized in clinical practice, potentially replacing traditional heat-cured resin in various applications.

11.
Med Mycol ; 50(4): 378-85, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21981028

RESUMO

We compared the E-test method to that of the Neo-Sensitabs tablet diffusion assay for evaluating the in vitro susceptibility of 100 clinical isolates of filamentous fungi (Aspergillus spp., Fusarium spp., Scedosporium spp., zygomycetes and other molds) to amphotericin B, itraconazole, voriconazole, caspofungin, and posaconazole. We determined the categorical agreement level between E-test minimum inhibitory concentrations (MIC) and tablet end-points, as opposed to the following disagreement parameters: very major error - resistant parameter (R) in E-test and susceptible (S) in tablet; major error - S by E-test and R by tablet; minor error - shifts between S and susceptible dose-dependent (S-DD) or S-DD and R. We also performed linear regression analyses and computed Pearson's correlation coefficients (R values) between the log transforms of MICs and the inhibition zone diameters of the five studied antifungal agents. For itraconazole we obtained 97% categorical agreement and R = -0.727. Categorical agreement for caspofungin and voriconazole was 96% and R =-0.821 and R = -0.789, respectively. For posaconazole the categorical agreement was 94% and R =-0.743. Amphotericin B exhibited a lower degree of agreement (76%, R = -0.672), especially in studies of Aspergillus spp. Our results suggest a potential value of the Neo-Sensitabs assay for in vitro susceptibility testing of molds to itraconazole, voriconazole, caspofungin and posaconazole, while amphotericin B exhibited an overall lower degree of agreement.


Assuntos
Antifúngicos/farmacologia , Fungos/efeitos dos fármacos , Micologia/métodos , Erros de Diagnóstico/estatística & dados numéricos , Fungos/isolamento & purificação , Humanos , Testes de Sensibilidade Microbiana/métodos , Micoses/microbiologia
12.
Acta Histochem ; 124(4): 151897, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35468563

RESUMO

INTRODUCTION: The pineal gland is a small photo-neuro-endocrine organ. This study used human post-mortem pineal glands to microscopically assess immunohistochemical marker intensity and percentage of positivity using known and novel digital techniques. MATERIALS AND METHODS: An experimental non-inferiority study has been performed on 72 pineal glands harvested from post-mortem examinations. The glands have been stained with glial fibrillary acidic protein (GFAP), synaptophysin (SYN), neuron-specific enolase (NSE), and neurofilament (NF). Slides were digitally scanned. Morphometric data were obtained using optical analysis, CaseViewer, ImageJ, and MorphoRGB RESULTS: Strong and statistically significant correlations were found and plotted using Bland-Altman diagrams between the two image analysis software in the case of mean percentage and intensity of GFAP, NSE, NF, and SYN. DISCUSSIONS: Software such as SlideViewer and ImageJ, with our novel software MorphoRGB were used to perform histological morphometry of the pineal gland. Digital morphometry of a small organ such as the pineal gland is easy to do by using whole slide imaging (WSI) and digital image analysis software, with potential use in clinical settings. MorphoRGB provides slightly more accurate data than ImageJ and is more user-friendly regarding measurements of parenchyma percentage stained by immunohistochemistry. The results show that MorphoRGB is not inferior in functionality. CONCLUSIONS: The described morphometric techniques have potential value in current practice, experimental small animal models and human pineal glands, or other small endocrine organs that can be fully included in a whole slide image. The software we used has applications in quantifying immunohistochemical stains.


Assuntos
Glândula Pineal , Animais , Autopsia , Imuno-Histoquímica
13.
Rom J Morphol Embryol ; 62(2): 545-551, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35024743

RESUMO

AIM: While histology remains the "gold standard" for cutaneous tumoral pathology, high-frequency ultrasound (HFUS) was shown to play a significant role in the non-invasive, pre-therapeutic assessment of skin tumors. The aim of our study was to determine whether there is a significant correlation between the ultrasound (US) and histological measurements of basal cell carcinoma (BCC) tumor depth. MATERIALS AND METHODS: The present study retrospectively analyzed clinical, dermoscopy, HFUS and histological examinations of 90 patients (52 men and 38 women) with histologically confirmed BCC, with focus on tumor depth index (DI). RESULTS: On clinical examination, 54 lesions were nodular (32 presented ulcerations) and 36 superficial lesions. Dermoscopy showed suggestive signs of BCC, most frequently "in focus" arborising superficial vessels (n=81), blue-grey ovoid nests (n=48) and specks of brown pigment (n=7). HFUS revealed well-defined (n=88) or poorly defined (n=2) hypoechoic, vascularized lesions, with inhomogeneous structure (n=90) and characteristic hyperechoic dots (n=36). A strong correlation (Pearson's r=0.92) between the HFUS (mean measured US depth = 1.33 mm) and histological (mean measured histological depth = 1.47 mm) DI of the investigated skin lesions was found, although significant differences (p<0.001 - t-test for paired samples) between the two measurements were observed. CONCLUSIONS: HFUS provides reliable information about BCC depth of invasion that cannot be otherwise obtained prior to surgery. In this manner, it completes the preclinical evaluation and can have an impact on the choice of the optimal therapeutic method.


Assuntos
Carcinoma Basocelular , Neoplasias Cutâneas , Carcinoma Basocelular/diagnóstico por imagem , Feminino , Humanos , Masculino , Estudos Retrospectivos , Neoplasias Cutâneas/diagnóstico por imagem , Ultrassonografia
14.
Int J Prosthodont ; 34(2): 154­162, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32588998

RESUMO

PURPOSE: To assess patient self-perception of overall dental appearance and of potentially localized dyschromic teeth and to compare them to the perception of the treating dentist. MATERIALS AND METHODS: A sample of 160 patients from Cluj-Napoca, Romania, answered a questionnaire regarding the self-perception of their dental appearance and of potential localized dental discolorations. The same questions were answered by their dentist, without knowing their answers, after clinical examination of each patient. Each patient and the dentist were asked to indicate a tooth with a pleasant color to be considered as reference. Color measurements of teeth indicated as dyschromic and of the reference teeth were performed using a spectrophotometer. Color differences were calculated using the ΔE00 formula. RESULTS: Tooth color was considered the most disturbing factor of their dental appearance by 41.25% of patients. Most patients (58.12%) acknowledged localized dyschromic teeth in their dental arches. Agreement between patients and dentist regarding the identification of dyschromic teeth was found in 61.87% of cases. The DE00 between the reference teeth and the teeth considered dyschromic by both patients and dentist ranged between 0.8 and 23.1. Disagreement between patients and dentist was found in 38.12% of situations. For teeth considered dyschromic only by patients, the ΔE00 ranged between 0.8 and 23.1. For teeth considered dyschromic only by the dentist, the ΔE00 ranged between 0.8 and 25. CONCLUSION: Most patients expressed concerns regarding their overall dental color and perceived themselves as having teeth with localized dyschromia. More than a third of the investigated patients had different perceptions regarding dyschromic teeth compared to their dentist. The majority of ΔE00 values calculated between dyschromic and reference teeth exceeded the perceptibility and acceptability thresholds.


Assuntos
Percepção de Cores , Dente , Cor , Odontólogos , Humanos , Espectrofotometria
15.
Artigo em Inglês | MEDLINE | ID: mdl-34299755

RESUMO

Cleft lip and palate is the most frequent birth anomaly, with increasing reported rates of complications, such as palate fistulae. Current studies concerning the occurrence rate of cleft lip and palate (CLP) report 2 to 10 cases in 10,000 births. The purpose of this study was to investigate the existence of factors that could predict the occurrence of fistulae after cleft lip and palate surgery. A retrospective study was performed by collecting and analyzing data from all patients who were operated for cleft lip and/or palate in the Maxillo-Facial Department of the Emergency Clinical County Hospital of Cluj-Napoca, Romania, between 2010 and 2020. We investigated the existing evidence for possible links between the number of fistulae observed after the primary palatoplasty and the age at which the primary palatoplasty was performed, the sex of the patient, the type of cleft, the timing of the surgical corrections, and the presence of comorbidities. A total of 137 cases were included for analysis. A significant link between the number of fistulae and the type of cleft was found (with fistulae occurring more frequently after the surgical correction of CLP-p < 0.001). No evidence was found for the existence of significant links between the number of fistulae and the patient's sex, the timing of surgery, or the presence of comorbidities. This study concluded that the incidence of palatal fistulae appears to be influenced by the type of cleft (CLP), but not by the sex of the patient, the timing of surgery, or the presence of comorbidities.


Assuntos
Fenda Labial , Fissura Palatina , Fenda Labial/epidemiologia , Fenda Labial/cirurgia , Fissura Palatina/epidemiologia , Fissura Palatina/cirurgia , Humanos , Lactente , Prognóstico , Estudos Retrospectivos , Romênia/epidemiologia
16.
J Med Life ; 14(2): 181-197, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34104241

RESUMO

The present study investigated the capacity of Suprathel® (a copolymer membrane, so far validated for skin regeneration) to also regenerate oral tissue - mucosa and bone, by comparing this biomaterial, in a split-mouth rabbit model, to Mucoderm®, a xenogeneic collagen matrix certified for keratinized oral mucosa healing. The clinical reason behind this experimental animal model was to determine whether the benefits of this advanced skin regeneration product (Suprathel®) could be conveyed for future evaluation in clinical trials of oral tissue regeneration in humans. The outcomes of this study validated the use of Suprathel®, a terpolymer of polylactide with trimethylene carbonate and ε-caprolactone, for stimulation of oral epithelium and alveolar bone regeneration in rabbits. Both Suprathel® and Mucoderm® exhibited comparable results and the null hypothesis stating a comparable regenerating effect of these two materials could not be rejected.


Assuntos
Osso e Ossos/patologia , Epitélio/patologia , Boca/fisiologia , Poliésteres/química , Regeneração , Cicatrização , Animais , Materiais Biocompatíveis/farmacologia , Regeneração Óssea/efeitos dos fármacos , Regeneração Óssea/fisiologia , Osso Esponjoso/patologia , Regeneração Tecidual Guiada , Masculino , Mucosa Bucal/patologia , Neovascularização Fisiológica/efeitos dos fármacos , Osteogênese/efeitos dos fármacos , Coelhos , Cicatrização/efeitos dos fármacos
17.
Med Pharm Rep ; 93(1): 89-96, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32133452

RESUMO

BACKGROUND AND AIMS: To verify the color match of metal-ceramic and full ceramic crowns, using instrumental methods. METHODS: A number of 153 teeth (anterior and posterior teeth), in 62 patients, were restored with metal ceramic (MC, n=119), pressed-ceramic (PC, n=28), and zirconia-ceramic (ZC, n=6) full coverage crowns. The shade of a reference natural tooth was recorded instrumentally with a dental spectrophotometer (Vitaeasyshade Advance 4.0) in "single tooth measurement", which provided the base color in Vita Classic (VC) and Vita 3D Master shades (3D).For verifying the outcome of the restoration "verify restoration" mode was used, and ΔE values were recorded for both VC and 3D Master shade guides. Moreover, matching symbols were also recorded (***=good, **=fair, *=poor). Descriptive statistics was performed and data were analyzed (One-sample z-Test, α=0.05) for comparison with visual thresholds in dentistry (Perceptibility Threshold - PT=1.2 and Acceptability Threshold - AT=2.7). RESULTS: The data did not follow a normal distribution (Kolmogorov-Smirnov test, p<0.05). Recorded color difference was significantly higher than PT and AT, for all types of restorations, regardless of the coding system (p<0.05). For MC crowns in 2.52% (4.20% for 3D) of the cases the color difference was smaller than PT, in 19.32% (the same for 3D) of cases was between PT and AT, and in 78.15% (76.47% for 3D) of cases was higher than the AT. For PC crowns in 3.57% (0% for 3D) of the cases the color difference was smaller than PT, in 25% (32.14% for 3D) of cases was between PT and AT, and in 71.42% (67.85% for 3D) of cases was higher than the AT. In the case of ZC crowns none of the restorations had color difference smaller than PT, but in 16.66% of cases was between PT and AT, and in 83.33% of cases was higher than the AT, for both VC and 3D. CONCLUSION: Within the limitations of the study, a better color match was achieved in the case of pressed ceramic crowns, made of lithium disilicate. In most of the situations the color difference between the restoration and the reference tooth exceeded the perceptibility thresholds, but the matching was recorded as "fair" by the spectrophotometer.

18.
J Gastrointestin Liver Dis ; 28(4): 483-493, 2019 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-31826063

RESUMO

BACKGROUND AND AIMS: Recent studies have evaluated the relationship associating non-alcoholic fatty liver disease (NAFLD) with several electrocardiogram (ECG) findings, but the results have been inconsistent. The aim of this systematic review is to assess the association between NAFLD with ECG modifications. METHODS: We conducted a systematic search on PubMed with predefined keywords identifying observational studies published till 22 February 2019 with NAFLD diagnosed either by biopsy, imaging, surrogate markers or ICD code and ECG findings by either a standard ECG, 24-hour Holter ECG or ICD code. Quality assessment was performed using the quality assessment tools from the National Heart, Lung, and Blood Institute. RESULTS: A total of 20 observational studies (1 case-control, 4 cohort, 15 cross-sectional studies, 401,745 individuals) were included. Twelve studies evaluated cardiac arrhythmias in NAFLD subjects, out of which 10 evaluated atrial fibrillation (AF). Although results were inconsistent, most studies rated as "good" demonstrated that hepatic steatosis was independently associated with an increased risk for prevalent AF in NAFLD patients. Diabetic patients with NAFLD were associated with an increased risk of ventricular arrhythmias in only one study rated as "good". Two studies rated as "good" demonstrated that hepatic steatosis was associated with a prolonged QTc interval. Four studies supported the association between cardiac conduction abnormalities and NAFLD, out of which two were rated as "good". Two studies assessed ECG modifications of ischemic heart disease (IHD), but only one having a "good" rating confirmed this independent association. CONCLUSIONS: Studies of high quality and with low risk of bias demonstrated that NAFLD is independently associated with AF, a prolonged QTc interval, bundle branch and atrioventricular blocks. Diabetic patients with NAFLD present an increased risk for developing ventricular arrhythmias.


Assuntos
Arritmias Cardíacas/etiologia , Hepatopatia Gordurosa não Alcoólica/complicações , Fibrilação Atrial/etiologia , Eletrocardiografia , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Hepatopatia Gordurosa não Alcoólica/diagnóstico
19.
Materials (Basel) ; 12(20)2019 Oct 21.
Artigo em Inglês | MEDLINE | ID: mdl-31640243

RESUMO

BACKGROUND: Once inserted and osseointegrated, dental implants become ankylosed, which makes them immobile with respect to the alveolar bone. The present paper describes the development of a new and original implant design which replicates the 3D physiological mobility of natural teeth. The first phase of the test followed the resistance of the implant to mechanical stress as well as the behavior of the surrounding bone. Modifications to the design were made after the first set of results. In the second stage, mechanical tests in conjunction with finite element analysis were performed to test the improved implant design. METHODS: In order to test the new concept, 6 titanium alloy (Ti6Al4V) implants were produced (milling). The implants were fitted into the dynamic testing device. The initial mobility was measured for each implant as well as their mobility after several test cycles. In the second stage, 10 implants with the modified design were produced. The testing protocol included mechanical testing and finite element analysis. RESULTS: The initial testing protocol was applied almost entirely successfully. Premature fracturing of some implants and fitting blocks occurred and the testing protocol was readjusted. The issues in the initial test helped design the final testing protocol and the new implants with improved mechanical performance. CONCLUSION: The new prototype proved the efficiency of the concept. The initial tests pointed out the need for design improvement and the following tests validated the concept.

20.
Int Dent J ; 68(3): 152-161, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29315538

RESUMO

BACKGROUND: The recognition of work stressors and their links to sociodemographic characteristics, health behaviours and coping strategies is important for enhancing the working conditions of dentists. AIM: The aim of our study was to identify and rank work stressors in dentists from Cluj-Napoca, Romania, and to investigate their potential links to sociodemographic characteristics, health behaviours and coping strategies. STUDY DESIGN: A questionnaire based on the Work Stress Inventory for Dentists (WSID) was delivered to a cross-sectional sample of 250 dentists working in six neighborhoods across Cluj-Napoca, Romania, as well as at the local Faculty of Dentistry. We collected and analysed information on sociodemographic characteristics, work stressors, health behaviours and coping strategies. RESULTS: Time and scheduling pressure, concerns about the future and pay-related work stressors were found to rank highest among the categories of work stressors investigated. Higher work stress was significantly linked to higher workloads, lower job satisfaction, poorer eating and exercise habits, higher work pain and discomfort, lower perceived health and less sleep. Job satisfaction was the single best predictor variable of work stress scores. The most frequently used coping strategy to deal with work stress was resting and taking breaks. Only one-quarter of respondents used active coping strategies. CONCLUSION: Our findings suggest that work stress is linked to a number of detrimental attitudes in dentists and that there is room for dentists to make lifestyle improvements.


Assuntos
Adaptação Psicológica , Odontólogos/psicologia , Comportamentos Relacionados com a Saúde , Estresse Psicológico , Adulto , Estudos Transversais , Feminino , Humanos , Satisfação no Emprego , Masculino , Romênia , Salários e Benefícios , Fatores Socioeconômicos , Tolerância ao Trabalho Programado , Carga de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA