Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Mol Genet Metab ; 113(1-2): 67-75, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25066104

RESUMO

Tyrosinemia type I (TYR I) is caused by autosomal recessive fumarylacetoacetate hydrolase deficiency and is characterized by development of severe liver disease in infancy and neurologic crises. If left untreated, most patients die of liver failure in the first years of life. Intervention with medication is effective when initiated during the first month of life. This improvement in the treatment of TYR I patients influenced the decision to include TYR I in the US Secretary of the Department of Health and Human Services' (HHS) Recommended Uniform Screening Panel. However, while tyrosine is routinely measured in newborn screening (NBS) by tandem mass spectrometry (MS/MS), elevated tyrosine levels are not specific to TYR I. To improve the specificity of NBS for TYR I, several assays were developed to measure succinylacetone (SUAC) in dried blood spots (DBS). SUAC is a pathognomonic marker of TYR I, and its detection by NBS MS/MS is possible. This review of the current status of NBS for TYR I in the US is the result of discussions at the HHS Secretary's (Discretionary) Advisory Committee on Heritable Disorders in Newborns and Children about the inconsistent implementation of effective NBS for TYR I in the US. We sought to understand the different TYR I screening practices in US NBS programs. Results indicate that 50 out of 51 NBS programs in the US screen for TYR I, and a successful SUAC performance evaluation scheme is available from the Centers for Disease Control and Prevention. Programmatic and methodological barriers were identified that prevent widespread adoption of SUAC measurements in NBS laboratories. However, since SUAC detection is currently the best approach to NBS for TYR I, a further delay of the addition of SUAC measurement into NBS procedures is discouraged. SUAC measurement should improve both the false positive and false negative rate in NBS for TYR I thereby yielding the desired benefits for affected patients at no expense to the overall population served.


Assuntos
Heptanoatos/sangue , Triagem Neonatal , Tirosinemias/sangue , Tirosinemias/diagnóstico , Biomarcadores/sangue , Teste em Amostras de Sangue Seco/métodos , Teste em Amostras de Sangue Seco/normas , Humanos , Recém-Nascido , Triagem Neonatal/métodos , Triagem Neonatal/normas , Controle de Qualidade , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem
2.
Artigo em Inglês | MEDLINE | ID: mdl-38701341

RESUMO

BACKGROUND: Single-tier newborn screening (NBS) for CAH using 17-hydroxyprogesterone (17OHP) measured by fluoroimmunoassay (FIA) in samples collected at 24-48 hours produces a high false-positive rate (FPR). 2nd tier steroid testing can reduce the FPR and has been widely implemented. We investigated the accuracy of an alternative multi-tier CAH NBS protocol that incorporates molecular testing of the CYP21A2 gene and reduces the 1st tier 17OHP cutoff to minimize missed cases. METHODS: Created a Minnesota-specific CYP21A2 pathogenic variants panel; develop a rapid, high-throughput multiplex, allele-specific-primer-extension assay; perform 1-year retrospective analysis of Minnesota NBS results comparing metrics between a conventional steroid-based two-tier protocol and a molecular-based multi-tier NBS protocol, applied post-hoc. RESULTS: CYP21A2 gene sequencing of 103 Minnesota families resulted in a Minnesota-specific panel of 21 pathogenic variants. Centers for Disease Control and Prevention (CDC) created a molecular assay with 100% accuracy and reproducibility. Two-tier steroid-based screening of 68,659 live births during 2015 resulted in 2 false negatives (FNs), 91 FPs, and 1 true positive (TP). A three-tier protocol with a lower 1st-tier steroid cutoff, 2nd-tier 21-variant CYP21A2 panel and 3rd-tier CYP21A2 sequencing would have resulted in 0 FNs, 52 FPs and 3 TPs. CONCLUSIONS: Incorporation of molecular testing could improve the accuracy of CAH NBS, although some distinct challenges of molecular testing may need to be considered before implementation by NBS programs.

3.
Clin Chem ; 56(11): 1686-95, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20807894

RESUMO

BACKGROUND: Newborn screening (NBS) for inborn errors of propionate, methionine, and cobalamin metabolism relies on finding abnormal concentrations of methionine and propionylcarnitine. These analytes are not specific for these conditions and lead to frequent false-positive results. More specific markers are total homocysteine (tHCY), methylmalonic acid (MMA), and methylcitric acid (MCA), but these markers are not detected by current NBS methods. To improve this situation, we developed a method for the detection of tHCY, MMA, and MCA in dried blood spots (DBSs) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). METHODS: The analytes were extracted from a single 4.8-mm DBS punch with acetonitrile:water:formic acid (59:41:0.42) containing dithiothreitol and isotopically labeled standards (d(3)-MMA, d(3)-MCA, d(8)-homocystine). The extract was dried and treated with 3 N HCl in n-butanol to form butylesters. After evaporation of the butanol, the residue was reconstituted and centrifuged and the supernatant was subjected to LC-MS/MS analysis. Algorithms were developed to apply this method as an efficient and effective second-tier assay on samples with abnormal results by primary screening. RESULTS: The 99th percentiles determined from the analysis of 200 control DBSs for MMA, MCA, and HCY were 1.5, 0.5, and 9.8 µmol/L, respectively. Since 2005, prospective application of this second-tier analysis to 2.3% of all NBS samples led to the identification of 13 affected infants. CONCLUSIONS: Application of this assay reduced the false-positive rate and improved the positive predictive value of NBS for conditions associated with abnormal propionylcarnitine and methionine concentrations.


Assuntos
Citratos/sangue , Homocisteína/sangue , Ácido Metilmalônico/sangue , Coleta de Amostras Sanguíneas , Cromatografia Líquida , Reações Falso-Positivas , Humanos , Recém-Nascido , Limite de Detecção , Triagem Neonatal , Valor Preditivo dos Testes , Valores de Referência , Espectrometria de Massas em Tandem
4.
Artigo em Inglês | MEDLINE | ID: mdl-32514487

RESUMO

An increasing number of newborn screening laboratories in the United States and abroad are moving towards incorporating next-generation sequencing technology, or NGS, into routine screening, particularly for cystic fibrosis. As more programs utilize this technology for both cystic fibrosis and beyond, it is critical to identify appropriate DNA extraction methods that can be used with dried blood spots that will result in consistent, high-quality sequencing results. To provide comprehensive quality assurance and technical assistance to newborn screening laboratories wishing to incorporate NGS assays, CDC's Newborn Screening and Molecular Biology Branch designed a study to evaluate the performance of nine commercial or laboratory-developed DNA extraction methods that range from a highly purified column extraction to a crude detergent-based no-wash boil prep. The DNA from these nine methods was used in two NGS library preparations that interrogate the CFTR gene. All DNA extraction methods including the cruder preps performed reasonably well with both library preps. One lower-concentration, older sample was excluded from one of the assay evaluations due to poor performance across all DNA extraction methods. When 84 samples, versus eight, were run on a flow cell, the DNA quality and quantity were more significant variables.

5.
Biol Psychol ; 77(1): 32-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17923241

RESUMO

Based on the premise that acute and chronic stresses stimulate and suppress cortisol secretion, respectively, and the hypothesis that marriage provides a buffer to stress, we tested whether extreme values of serum cortisol concentrations would be less likely in married women than in unmarried women. Three hundred women were recruited from two central Connecticut communities. Cortisol was measured in overnight urine samples using liquid chromatography-tandem mass spectrometry. Information on each subject's demographic characteristics, such as income and education level was collected. Mean log urinary cortisol was virtually identical in married and unmarried women, however, as predicted, the variance was significantly larger in the unmarried group (p=0.01). After adjustment for potential confounders, multivariate logistic regression still revealed that absolute deviation of log(10) cortisol from the mean was smaller for married versus unmarried women (p<0.01); deviation from the mean cortisol was also higher for non-working than working women. These results support the idea that marriage and employment reduce the extreme levels of cortisol secretion, and by extension, this may reflect differences in levels of stress in married and in working women compared to unmarried and non-working women.


Assuntos
Hidrocortisona/urina , Estado Civil , Pós-Menopausa/metabolismo , Pós-Menopausa/psicologia , Idoso , Análise por Conglomerados , Connecticut/epidemiologia , Creatinina/urina , Educação , Feminino , Humanos , Renda , Modelos Logísticos , Pessoa de Meia-Idade , Fatores Socioeconômicos
6.
Int J Neonatal Screen ; 1(1): 13-26, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26309908

RESUMO

Newborn screening is the largest genetic testing effort in the United States and is considered one of the ten great public health achievements during the first 10 years of the 21st century. For over 35 years, the Newborn Screening Quality Assurance Program (NSQAP) at the US Centers for Disease Control and Prevention has helped NBS laboratories ensure that their testing does not delay diagnosis, minimizes false-positive reports, and sustains high-quality testing performance. It is a multi-component program that provides comprehensive quality assurance services for dried blood spot testing. The NSQAP, the Biochemical Mass Spectrometry Laboratory (BMSL), the Molecular Quality Improvement Program (MQIP) and the Newborn Screening Translation Research Initiative (NSTRI), aid screening laboratories achieve technical proficiency and maintain confidence in their performance while processing large volumes of specimens daily. The accuracy of screening tests could be the difference between life and death for many babies; in other instances, identifying newborns with a disorder means that they can be treated and thus avoid life-long disability or severe cognitive impairment. Thousands of newborns and their families have benefited from reliable and accurate testing that has been accomplished by a network of screening laboratories and the NSQAP, BMSL, MQIP and NSTRI.

7.
Blood ; 105(4): 1531-9, 2005 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-15498853

RESUMO

Mechanisms of tissue-restricted patterns of von Willebrand factor (VWF) expression involve activators and repressors that limit expression to endothelial cells and megakaryocytes. The relative transcriptional activity of the proximal VWF promoter was assessed in VWF-producing and -nonproducing cells, and promoter activity was highest in endothelial cells followed by megakaryocytes. Only basal VWF promoter activity was seen in nonendothelial cells. Here we identify a negative response element located at nucleotides (nts) +96/+105 and demonstrate, using chromatin immunoprecipitation (ChIP) analysis, that in vivo this sequence interacts with the E4BP4 transcriptional repressor. Differences in size and relative abundance of nuclear E4BP4 were observed. In HepG2 cells, low levels of larger forms of E4BP4 are present that directly interact with the negative response element. In VWF-expressing cells, high levels of smaller forms predominate with no evidence of direct DNA binding. However, in endothelial cells, mutation of the VWF E4BP4 binding motif not only restores but also further elevates VWF promoter activity, suggesting that E4BP4 may be part of a coordinated binding complex. These observations implicate this binding motif in repressing both activated and basal levels of VWF transcription by different cell type-specific mechanisms, and support the hypothesis that E4BP4 sequesters negative regulators of transcription, thereby enhancing activated gene expression.


Assuntos
Proteínas de Ligação a DNA/fisiologia , Endotélio Vascular/citologia , Endotélio Vascular/metabolismo , Proteínas Repressoras/fisiologia , Fatores de Transcrição/fisiologia , Fator de von Willebrand/biossíntese , Fator de von Willebrand/metabolismo , Animais , Sequência de Bases , Fatores de Transcrição de Zíper de Leucina Básica , Western Blotting , Bovinos , Linhagem Celular , Linhagem Celular Tumoral , Cricetinae , Proteínas de Ligação a DNA/genética , Proteínas de Ligação a DNA/metabolismo , Éxons/genética , Fatores de Ligação G-Box , Células HeLa , Humanos , Camundongos , Dados de Sequência Molecular , Mutagênese Sítio-Dirigida , Proteínas Nucleares/análise , Proteínas Nucleares/metabolismo , Regiões Promotoras Genéticas/genética , Ligação Proteica/genética , Proteínas Repressoras/genética , Proteínas Repressoras/metabolismo , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo , Transfecção , Fator de von Willebrand/antagonistas & inibidores , Fator de von Willebrand/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA