Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Am J Cardiol ; 122(12): 2095-2103, 2018 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-30293652

RESUMO

Preoperative evaluation of the mitral valve but also of tricuspid valve and right ventricular (RV) function is mandatory in primary mitral regurgitation (MR) secondary to mitral valve prolapse (MVP). Tricuspid annulus (TA) diameter plays a pivotal role in the surgical decision to perform preventive combined tricuspid valve annuloplasty. Cardiac magnetic resonance (CMR) is the gold standard for the assessment of RV size and function. Based on 70 consecutive patients (17 women; mean age 64 ± 12) with severe MR secondary to MVP referred for CMR, we sought to assess RV geometry and function and TA dimensions and to study the interaction between TA dilatation and right-sided cardiac chambers. Frequency of RV dilatation, RV systolic dysfunction, and TA dilatation (TA diameter ≥ 40 or 21 mm/m²) were 11%, 51%, and 49%, respectively. Left ventricular (LV) end-diastolic volume index was the only independent predictor of RV dilatation. Presence of symptoms, larger LV end-diastolic volume index, and LV ejection fraction <60% were independently associated with RV dysfunction. Absolute TA diameter was 36 ± 6 mm and TA diameter index was 20 ± 3 mm/m². Reproducibility TA diameter measurement was excellent (coefficient of variation ≤10%). TR velocity >220 cm/s (odds ratio = 20.17; [3.57 to 113.90]; p = 0.001 and right atrial volume index ≥ 38 ml/m² (odds ratio = 13.44; [3.57 to 50.54]; p = 0.0001) were independent predictors of TA diameter ≥40 or 21 mm/m². CMR provides accurate right-sided cardiac chambers assessment and may help surgical planning of concomitant tricuspid valve annuloplasty before mitral valve repair in severe MR secondary to MVP. In conclusion, TA dilatation, RV enlargement, and dysfunction are related to pulmonary pressure and left-sided cardiac chambers enlargement, reflecting the long-standing consequences of severe MR.


Assuntos
Ventrículos do Coração/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico , Prolapso da Valva Mitral/fisiopatologia , Valva Mitral/diagnóstico por imagem , Função Ventricular Direita/fisiologia , Remodelação Ventricular , Idoso , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/diagnóstico
2.
Arch Cardiovasc Dis ; 110(11): 580-589, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28566200

RESUMO

BACKGROUND: Three-dimensional (3D) transthoracic echocardiography (TTE) is superior to two-dimensional Simpson's method for assessment of left ventricular (LV) volumes and LV ejection fraction (LVEF). Nevertheless, 3D TTE is not incorporated into everyday practice, as current LV chamber quantification software products are time-consuming. AIMS: To evaluate the feasibility, accuracy and reproducibility of new fully automated fast 3D TTE software (HeartModelA.I.; Philips Healthcare, Andover, MA, USA) for quantification of LV volumes and LVEF in routine practice; to compare the 3D LV volumes and LVEF obtained with a cardiac magnetic resonance (CMR) reference; and to optimize automated default border settings with CMR as reference. METHODS: Sixty-three consecutive patients, who had comprehensive 3D TTE and CMR examinations within 24hours, were eligible for inclusion. Nine patients (14%) were excluded because of insufficient echogenicity in the 3D TTE. Thus, 54 patients (40 men; mean age 63±13 years) were prospectively included into the study. RESULTS: The inter- and intraobserver reproducibilities of 3D TTE were excellent (coefficient of variation<10%) for end-diastolic volume (EDV), end-systolic volume (ESV) and LVEF. Despite a slight underestimation of EDV using 3D TTE compared with CMR (bias=-22±34mL; P<0.0001), a significant correlation was found between the two measurements (r=0.93; P=0.0001). Enlarging default border detection settings leads to frequent volume overestimation in the general population, but improved agreement with CMR in patients with LVEF≤50%. Correlations between 3D TTE and CMR for ESV and LVEF were excellent (r=0.93 and r=0.91, respectively; P<0.0001). CONCLUSION: 3D TTE using new-generation fully automated software is a feasible, fast, reproducible and accurate imaging modality for LV volumetric quantification in routine practice. Optimization of border detection settings may increase agreement with CMR for EDV assessment in dilated ventricles.


Assuntos
Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Software , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Automação , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA