Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 147(21): 1568-1578, 2023 05 23.
Artigo em Inglês | MEDLINE | ID: mdl-36960730

RESUMO

BACKGROUND: Treatment options for high-risk Brugada syndrome (BrS) with recurrent ventricular fibrillation (VF) are limited. Catheter ablation is increasingly performed but a large study with long-term outcome data is lacking. We report the results of the multicenter, international BRAVO (Brugada Ablation of VF Substrate Ongoing Registry) for treatment of high-risk symptomatic BrS. METHODS: We enrolled 159 patients (median age 42 years; 156 male) with BrS and spontaneous VF in BRAVO; 43 (27%) of them had BrS and early repolarization pattern. All but 5 had an implantable cardioverter-defibrillator for cardiac arrest (n=125) or syncope (n=34). A total of 140 (88%) had experienced numerous implantable cardioverter-defibrillator shocks for spontaneous VF before ablation. All patients underwent a percutaneous epicardial substrate ablation with electroanatomical mapping except for 8 who underwent open-thoracotomy ablation. RESULTS: In all patients, VF/BrS substrates were recorded in the epicardial surface of the right ventricular outflow tract; 45 (29%) patients also had an arrhythmic substrate in the inferior right ventricular epicardium and 3 in the posterior left ventricular epicardium. After a single ablation procedure, 128 of 159 (81%) patients remained free of VF recurrence; this number increased to 153 (96%) after a repeated procedure (mean 1.2±0.5 procedures; median=1), with a mean follow-up period of 48±29 months from the last ablation. VF burden and frequency of shocks decreased significantly from 1.1±2.1 per month before ablation to 0.003±0.14 per month after the last ablation (P<0.0001). The Kaplan-Meier VF-free survival beyond 5 years after the last ablation was 95%. The only variable associated with a VF-free outcome in multivariable analysis was normalization of the type 1 Brugada ECG, both with and without sodium-channel blockade, after the ablation (hazard ratio, 0.078 [95% CI, 0.008 to 0.753]; P=0.0274). There were no arrhythmic or cardiac deaths. Complications included hemopericardium in 4 (2.5%) patients. CONCLUSIONS: Ablation treatment is safe and highly effective in preventing VF recurrence in high-risk BrS. Prospective studies are needed to determine whether it can be an alternative treatment to implantable cardioverter-defibrillator implantation for selected patients with BrS. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT04420078.


Assuntos
Síndrome de Brugada , Ablação por Cateter , Desfibriladores Implantáveis , Humanos , Masculino , Adulto , Fibrilação Ventricular , Eletrocardiografia/métodos , Ventrículos do Coração , Síndrome de Brugada/cirurgia , Síndrome de Brugada/complicações , Desfibriladores Implantáveis/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
2.
Heart Rhythm ; 20(6): 918-926, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36863637

RESUMO

The current design of an innovative left ventricular assist device (LVAD) makes use of magnetic levitation technology, which enables the rotors of the device to be completely suspended by magnetic force, reducing friction and blood or plasma damage. However, this electromagnetic field can result in electromagnetic interference (EMI), which can interfere with proper functioning of another cardiac implantable electronic device (CIED) in its direct proximity. Approximately 80% of patients with an LVAD have a CIED, most frequently an implantable cardioverter-defibrillator (ICD). Several device-device interactions have been reported, including EMI-induced inappropriate shocks, inability to establish telemetry connection, EMI-induced premature battery depletion, undersensing by the device, and other CIED malfunctions. Unfortunately, additional procedures, including generator exchange, lead adjustment, and system extraction, are frequently required because of these interactions. In some circumstances, the additional procedure might be preventable or avoidable with appropriate solutions. In this article, we describe how EMI from the LVAD impacts the functionality of the CIED and provide possible management options, including manufacturer-specific information, for the current CIEDs (eg, transvenous and leadless pacemakers, transvenous and subcutaneous ICDs, and transvenous cardiac resynchronization therapy pacemakers and ICDs).


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Coração Auxiliar , Marca-Passo Artificial , Humanos , Coração Auxiliar/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Desfibriladores Implantáveis/efeitos adversos , Insuficiência Cardíaca/terapia
3.
Am J Cardiol ; 179: 83-89, 2022 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-35909017

RESUMO

We postulated that familial idiopathic dilated cardiomyopathy (F-IDC) is associated with a worse prognosis than nonfamilial IDC (nonF-IDC). Patients with F-IDC had either a strong family history and/or proved genetic mutations. We studied long-term prognosis (mean follow-up: 6.1 ± 4.1 years) of 162 patients with IDC (age: 55.5 ± 17.9 years, men: 57.8%, 50% F-IDC) with an implantable cardioverter-defibrillator or cardiac resynchronization therapy. The primary end point was a composite of death, left ventricular (LV) assist device implant, or heart transplantation. The secondary end point was a ventricular arrhythmia event. There was no significant difference in the prevalence of diabetes, hypertension, New York Heart Association class, medical therapy, and years of follow-up between the F-IDC and nonF-IDC groups. Patients with F-IDC were younger than patients with nonF-IDC (49.1 ± 17.0 years vs 61.6 ± 16.5 years, p <0.001). Mean LV ejection fraction was significantly lower in F-IDC group than in the nonF-IDC group (26 ± 12% vs 31 ± 12%, p = 0.022). The primary end point was achieved in 54 patients in F-IDC group (66.7%) versus 19 in the nonF-IDC group (23.5%) (p <0.001). The Kaplan-Meier survival estimates for the composite end point and for ventricular arrhythmia were significantly lower in the F-IDC versus nonF-IDC (log-rank p ≤0.001 and 0.04, respectively). F-IDC was the only multivariable predictor of the primary composite end point (hazard ratio 3.419 [95% confidence interval 1.845 to 6.334], p <0.001). The likelihood of LV remodeling manifested by LV ejection fraction improvement (≥10%) was significantly lower in F-IDC than nonF-IDC (27.1% vs 44.8%, p = 0.042). In conclusion, F-IDC is a predictor of mortality, need for LV assist device, or heart transplantation. F-IDC is associated with significantly lower event-free survival for primary end point and ventricular arrhythmia than nonF-IDC. F-IDC has significantly lower likelihood of LV reverse remodeling than nonF-IDC.


Assuntos
Cardiomiopatia Dilatada , Transplante de Coração , Coração Auxiliar , Adulto , Idoso , Arritmias Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Volume Sistólico , Remodelação Ventricular
4.
J Biomech Eng ; 133(3): 031006, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21303182

RESUMO

Although left ventricular (LV) coronary sinus lead dislodgement remains a problem, the risk factors for dislodgement have not been clearly defined. In order to identify potential risk factors for acute lead dislodgement, we conducted dynamic finite element simulations of pacemaker lead dislodgement in marginal LV vein. We considered factors such as mismatch in lead and vein diameters, velocity of myocardial motion, branch angle between the insertion vein and the coronary sinus, degree of slack, and depth of insertion. The results show that large lead-to-vein diameter mismatch, rapid myocardial motion, and superficial insertion are potential risk factors for lead dislodgement. In addition, the degree of slack presents either a positive or negative effect on dislodgement risk depending on the branch angle. The prevention of acute lead dislodgment can be enforced by inducing as much static friction force as possible at the lead-vein interface, while reducing the external force. If the latter exceeds the former, dislodgement will occur. The present findings underscore the major risk factors for lead dislodgment, which may improve implantation criterion and future lead design.


Assuntos
Simulação por Computador , Eletrodos Implantados , Análise de Falha de Equipamento/métodos , Modelos Cardiovasculares , Marca-Passo Artificial , Medição de Risco/métodos , Veias/lesões , Estimulação Cardíaca Artificial/métodos , Seio Coronário , Remoção de Dispositivo , Eletrodos Implantados/efeitos adversos , Falha de Equipamento , Análise de Elementos Finitos , Corpos Estranhos/etiologia , Corpos Estranhos/prevenção & controle , Frequência Cardíaca/fisiologia , Ventrículos do Coração/fisiopatologia , Humanos , Marca-Passo Artificial/efeitos adversos , Resultado do Tratamento , Lesões do Sistema Vascular/etiologia , Lesões do Sistema Vascular/prevenção & controle , Veias/fisiopatologia , Disfunção Ventricular Esquerda/fisiopatologia
5.
J Biomech Eng ; 133(6): 061006, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21744926

RESUMO

The risk of myocardial penetration due to active-fixation screw-in type pacing leads has been reported to increase as the helix electrodes become smaller. In order to understand the contributing factors for lead penetration, we conducted finite element analyses of acute myocardial micro-damage induced by a pacemaker lead screw-in helix electrode. We compared the propensity for myocardial micro-damage of seven lead designs including a baseline model, three modified designs with various helix wire cross-sectional diameters, and three modified designs with different helix diameters. The comparisons show that electrodes with a smaller helix wire diameter cause more severe micro-damage to the myocardium in the early stage. The damage severity, represented by the volume of failed elements, is roughly the same in the middle stage, whereas in the later stage the larger helix wire diameter generally causes more severe damage. The onset of myocardial damage is not significantly affected by the helix diameter. As the helix diameter increases, however, the extent of myocardial damage increases accordingly. The present findings identified several of the major risk factors for myocardial damage whose consideration for lead use and design might improve acute and chronic lead performance.


Assuntos
Marca-Passo Artificial , Fenômenos Biomecânicos , Engenharia Biomédica , Simulação por Computador , Desfibriladores Implantáveis/efeitos adversos , Eletrodos Implantados/efeitos adversos , Desenho de Equipamento , Análise de Elementos Finitos , Traumatismos Cardíacos/etiologia , Humanos , Modelos Cardiovasculares , Marca-Passo Artificial/efeitos adversos , Fatores de Risco
6.
Curr Opin Cardiol ; 25(1): 59-64, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19881337

RESUMO

PURPOSE OF REVIEW: Several invasive and noninvasive tests for risk stratification of sudden cardiac death (SCD) have been studied. Tests such as microwave T wave alternans (repolarization abnormality) and signal-averaged ECG (depolarization abnormality) have high negative predictive values but low positive predictive values in patients with heart disease. The presence of a fragmented QRS (fQRS) complex on a routine 12-lead ECG is another marker of depolarization abnormality. The purpose of this review is to discuss the potential utility of tests to detect depolarization abnormalities of the heart for the risk stratification of mortality and SCD with main emphasis on fQRS. RECENT FINDINGS: fQRS is associated with increased mortality and arrhythmic events in patients with coronary artery disease. fQRS has also been defined as a marker of arrhythmogenic right ventricular cardiomyopathy and Brugada syndrome. In Brugada syndrome, the presence of fQRS predicts episodes of ventricular fibrillation during follow-up. SUMMARY: fQRS may be of value in determining the risk for SCD and guiding selection for device therapy in patients with structural heart disease and Brugada syndrome. It is possible that the predictive value of fQRS for SCD can be enhanced further by combining a marker of repolarization abnormality such as microwave T wave alternans.


Assuntos
Morte Súbita Cardíaca/etiologia , Eletrocardiografia/mortalidade , Arritmias Cardíacas/etiologia , Humanos , Magnetocardiografia , Valor Preditivo dos Testes , Fatores de Risco
7.
J Cardiovasc Pharmacol ; 55(5): 438-49, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20509177

RESUMO

Life-threatening ventricular arrhythmias such as sustained ventricular tachycardia and ventricular fibrillation are responsible for two thirds of sudden cardiac deaths annually in the United States. Implantable cardioverter-defibrillator (ICD) therapy prevents mortality from arrhythmic death but is expensive and has some associated morbidity from proarrhythmia and mechanical malfunction. Furthermore, ICDs treat ventricular arrhythmias but do not prevent them. Antiarrhythmic drugs (AADs) can be used for acute or chronic therapy to prevent ventricular arrhythmias and sudden cardiac deaths. AADS are often used in patients with an ICD who have recurrent ICD shocks resulting from ventricular arrhythmias. Class I AADs are contraindicated in patients with structural heart disease. Other than amiodarone, all Class III drugs have either a neutral or deleterious effect on mortality. Dronedarone, a new Class III drug, may reduce mortality, but more information is needed to be sure. A class of drugs that do not qualify as an AAD can modify cardiovascular remodeling processes and have a delayed and indirect antiarrhythmic effect. These so-called "nonantiarrhythmic drugs" such as drugs acting on the renin-angiotensin-aldosterone system, fish oil, and statins can reduce the likelihood of future ventricular tachycardia/ventricular fibrillation in patients with coronary artery disease or congestive heart failure. The role of AADs for chronic therapy for primary and secondary prevention of sudden cardiac death is problematic because of proarrhythmia and adverse side effects. Because these nonantiarrhythmic drugs are well tolerated and have no proarrhythmic actions, their benefits should outweigh risks.


Assuntos
Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/tratamento farmacológico , Morte Súbita Cardíaca/prevenção & controle , Antagonistas de Receptores de Angiotensina , Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Inibidores da Enzima Conversora de Angiotensina/farmacologia , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Antiarrítmicos/administração & dosagem , Antiarrítmicos/efeitos adversos , Antiarrítmicos/farmacologia , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Ácidos Graxos Insaturados/efeitos adversos , Ácidos Graxos Insaturados/farmacologia , Ácidos Graxos Insaturados/uso terapêutico , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Antagonistas de Receptores de Mineralocorticoides/efeitos adversos , Antagonistas de Receptores de Mineralocorticoides/farmacologia , Antagonistas de Receptores de Mineralocorticoides/uso terapêutico , Ensaios Clínicos Controlados Aleatórios como Assunto , Sistema Renina-Angiotensina/efeitos dos fármacos
8.
Pacing Clin Electrophysiol ; 32(9): 1207-21, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19719501

RESUMO

In recent years, the role of implantable pacing devices has expanded beyond the arrhythmia horizon and contemporary pacemakers' attempt to meet the physiological needs of patients. Modern pacemakers' functions include various modes of dual-chamber pacing, rate-response algorithms with dual sensors for optimum physiological response, cardiac resynchronization therapy (CRT), arrhythmia-prevention algorithms, antitachycardia pacing, and hemodynamic monitoring. The automaticity features of pacemakers enable continuous or intermittent monitoring of various pacemaker parameters including battery voltage, pacing impedance, sensing levels, pacing thresholds, and daily activity log. Modern pacemakers offer "physiological pacing" algorithms that minimize ventricular pacing and reduce the incidence of atrial fibrillation significantly. Ventricular pacing in patients with intact atrioventricular (AV) conduction or intermittent advanced AV block should be minimized with a hope to reduce heart failure hospitalization and mortality. A reduction in all-cause mortality due to physiological pacing, except for the CRT, has yet to be demonstrated in a randomized trial. Overall, modern pacemakers have acceptable performances to fulfill the clinical needs and have a reasonable safety margin. Promising new technologies are currently under development and offer hope to patients who may one day derive both symptomatic and mortality benefit from these devices.


Assuntos
Diagnóstico por Computador/instrumentação , Eletrocardiografia/instrumentação , Marca-Passo Artificial , Terapia Assistida por Computador/instrumentação , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Avaliação da Tecnologia Biomédica , Terapia Assistida por Computador/métodos
9.
Ann Noninvasive Electrocardiol ; 14(4): 319-26, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19804507

RESUMO

BACKGROUND: Fragmented QRS complexes (fQRS) on a 12-lead ECG are a marker of myocardial scar in patients with coronary artery disease. Cardiac sarcoidosis is also associated with myocardial granuloma formation and scarring. We evaluated the significance of fQRS on a 12-lead ECG compared to Gadolinium-delayed enhancement images (GDE) in cardiac magnetic resonance imaging (CMR). METHOD AND RESULTS: The ECGs of patients (n = 17, mean age: 52 +/- 11 years, male: 53%) with established diagnosis of sarcoidosis who underwent a CMR for evaluation of cardiac involvement were studied. ECG abnormalities included bundle branch block, Q wave, and fQRS. fQRS, Q wave, and bundle branch block were present in 9 (53%), 1 (6%), and 4 (24%) patients, respectively. The sensitivity and specificity of fQRS for detecting abnormal GDE were 100% and 80%, respectively. Sensitivity and specificity of Q waves were 11% and 100%, respectively. CONCLUSIONS: fQRS on a 12-lead ECG in patients with suspected cardiac sarcoidosis are associated with cardiac involvement as detected by GDE on CMR.


Assuntos
Cardiomiopatias/diagnóstico , Meios de Contraste , Eletrocardiografia/métodos , Gadolínio , Imageamento por Ressonância Magnética/métodos , Sarcoidose/diagnóstico , Bloqueio de Ramo/diagnóstico , Cardiomiopatias/complicações , Feminino , Seguimentos , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Retrospectivos , Sarcoidose/complicações , Sensibilidade e Especificidade
10.
Cardiol Clin ; 26(3): 459-79, vii, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18538191

RESUMO

Catheter ablation is an effective therapy for symptomatic ventricular arrhythmia (VA) in patients with and without structural heart disease. It is the treatment of choice to cure or reduce recurrent VA in patients who have an implantable cardioverter defibrillator and can be a life-saving procedure in patients who have electrical storm. Catheter ablation for VAs remains a challenging procedure and requires a precise understanding of cardiac electrophysiology, the arrhythmia mechanisms, and mapping techniques. Various mapping techniques such as pace mapping, activation mapping, entrainment mapping, and substrate mapping are used. These techniques complement each other in localizing the critical isthmus of a reentrant VT or the source of origin of a focal VT. Most VAs can be ablated endocardially. Epicardial ablation is needed for VAs with an epicardial circuit or a focal source.


Assuntos
Ablação por Cateter , Taquicardia Ventricular/terapia , Cardiomiopatia Dilatada/epidemiologia , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Cardiopatias Congênitas/epidemiologia , Doenças das Valvas Cardíacas/epidemiologia , Humanos , Medição de Risco , Taquicardia por Reentrada no Nó Atrioventricular/terapia , Fibrilação Ventricular/terapia , Complexos Ventriculares Prematuros/fisiopatologia , Complexos Ventriculares Prematuros/terapia
12.
Circulation ; 113(21): 2495-501, 2006 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-16717150

RESUMO

BACKGROUND: Q waves on a 12-lead ECG are markers of a prior myocardial infarction (MI). However, they may regress or even disappear over time, and there is no specific ECG sign of a non-Q-wave MI. Fragmented QRS complexes (fQRSs), which include various RSR' patterns, without a typical bundle-branch block are markers of altered ventricular depolarization owing to a prior myocardial scar. We postulated that the presence of an fQRS might improve the ability to detect a prior MI compared with Q waves alone by ECG. METHODS AND RESULTS: A cohort of 479 consecutive patients (mean+/-SD age, 58.2+/-13.2 years; 283 males) who were referred for nuclear stress tests was studied. The fQRS included various morphologies of the QRS (<120 ms), which included an additional R wave (R') or notching in the nadir of the S wave, or >1 R' (fragmentation) in 2 contiguous leads, corresponding to a major coronary artery territory. The Q wave was present in 71 (14.8%) patients, an fQRS was present in 191 (34.9%) patients, and an fQRS and/or a Q wave was present in 203 (42.3%) patients. Sensitivity, specificity, and the negative predictive value for myocardial scar as detected by single photon emission computed tomography analysis were 36.3%, 99.2%, and 70.8%, respectively, for the Q wave alone; 85.6%, 89%, and 92.7%, respectively, for the fQRS; and 91.4%, 89%, and 94.2%, respectively, for the Q wave and/or fQRS. CONCLUSIONS: The fQRS on a 12-lead ECG is a marker of a prior MI, defined by regional perfusion abnormalities, which has a substantially higher sensitivity and negative predictive value compared with the Q wave.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Eletrocardiografia/métodos , Idoso , Estudos de Coortes , Eletrocardiografia/normas , Teste de Esforço , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único
13.
Heart Rhythm ; 4(9): 1165-9, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17765615

RESUMO

BACKGROUND: The outcomes of patients with ventricular assist devices (VADs) who undergo catheter ablation for ventricular tachycardia (VT) have not been reported. OBJECTIVE: The purpose of this study was to assess the feasibility, safety, and efficacy of endocardial VT ablation in patients with VADs. METHODS: We retrospectively reviewed three cases at our institution where endocardial catheter ablation was performed in patients with VADs and incessant VT. RESULTS: Three patients with underlying cardiomyopathies and VADs underwent VT ablation for incessant VT refractory to multiple antiarrhythmic medications. In each case, VT was either eliminated or significantly ameliorated by catheter ablation. No procedure-related complications occurred. The hemodynamic stability afforded by the VAD played an important role in facilitating ablation in two of the cases. CONCLUSION: Catheter ablation for VT in VAD patients appears to be feasible, safe, and effective based on our initial experience. Several technical issues, such as decreases in ventricular volumes that can limit maneuverability of the ablation catheter and potential entrapment of the mapping catheter in the inflow cannula, need to be considered at the time of ablation.


Assuntos
Ablação por Cateter/métodos , Coração Auxiliar , Taquicardia Ventricular/cirurgia , Adulto , Idoso , Volume Cardíaco , Eletrocardiografia , Evolução Fatal , Estudos de Viabilidade , Humanos , Masculino , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Resultado do Tratamento
14.
J Nucl Cardiol ; 14(3): 347-53, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17556169

RESUMO

BACKGROUND: Fragmented QRS (FQRS) complexes, not typical of a bundle branch block, are a marker of regional myocardial injury. The extent of stress myocardial perfusion imaging (MPI) abnormalities with FQRS patterns is not known. METHODS AND RESULTS: Twelve-lead electrocardiograms (ECGs) in 501 patients undergoing stress MPI were studied. FQRS was defined as a QRS duration of 120 milliseconds or less, with notches or slurs of QRS complexes, on 2 contiguous leads of a coronary artery territory. Abnormal MPI was defined as a regional summed stress score (SSS) and summed rest score (SRS) of 3 or greater based on a 17-segment model. Patients with a typical bundle (n = 26), paced rhythm (n = 2), and Q waves (n = 64) were excluded. Of the remaining 409 patients (mean age, 58 +/- 13 years; 52% male), 155 (38%) had FQRS on the ECG. FQRS patients had a higher mean SSS, SRS, and global summed difference score and a lower left ventricular ejection fraction (all P < .001), as well as greater regional stress MPI scar (69% vs 11%, P < .001). FQRS pattern sensitivity was 75% and specificity was 94% for a corresponding regional MPI scar. On logistic regression, SSS, SRS, summed difference score, left ventricular ejection fraction, and regional scar were univariate predictors of the FQRS pattern on the ECG (all P < .01), and any regional scar (odds ratio, 32; P < .001) was a multivariate predictor. CONCLUSIONS: FQRS complexes on an ECG are a marker of higher stress MPI perfusion and functional abnormalities. Regional FQRS patterns denote the presence of a greater corresponding focal regional myocardial scar on stress MPI.


Assuntos
Arritmias Cardíacas/diagnóstico , Bloqueio de Ramo/diagnóstico , Doença da Artéria Coronariana/diagnóstico , Eletrocardiografia/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Ventricular Esquerda/diagnóstico , Arritmias Cardíacas/complicações , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade , Disfunção Ventricular Esquerda/complicações
16.
J Am Coll Cardiol ; 69(10): 1247-1256, 2017 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-28279291

RESUMO

BACKGROUND: Mounting evidence shows that localized sources maintain atrial fibrillation (AF). However, it is unclear in unselected "real-world" patients if sources drive persistent atrial fibrillation (PeAF), long-standing persistent atrial fibrillation (LPeAF), or paroxysmal atrial fibrillation (PAF); if right atrial sites are important; and what the long-term success of source ablation is. OBJECTIVES: The aim of this study was to analyze the role of rotors and focal sources in a large academic registry of consecutive patients undergoing source mapping for AF. METHODS: One hundred seventy consecutive patients (mean age 59 ± 12 years, 79% men) with PAF (37%), PeAF (31%), or LPeAF (32%). Of these, 73 (43%) had undergone at least 1 prior ablation attempt (mean 1.9 ± 0.8; range: 1 to 4). Focal impulse and rotor modulation (FIRM) with an endocardial basket catheter was used in all cases. RESULTS: FIRM analysis revealed sources in the right atrium in 85% of patients (1.8 ± 1.3) and in the left atrium in 90% of patients (2.0 ± 1.3). FIRM ablation terminated AF to sinus rhythm or atrial flutter or tachycardia in 59% (PAF), 37% (PeAF), and 19% (LPeAF) of patients, with 15 of 67 terminations due to right atrial ablation. On follow-up, freedom from AF after a single FIRM procedure for the entire series was 95% (PAF), 83% (PeAF), and 82% (LPeAF) at 1 year and freedom from all atrial arrhythmias was 77% (PAF), 75% (PeAF), and 57% (LPeAF). CONCLUSIONS: In the Indiana University FIRM registry, FIRM-guided ablation produced high single-procedure success, mostly in patients with nonparoxysmal AF. Data from mapping, acute terminations, and outcomes strongly support the mechanistic role of biatrial rotors and focal sources in maintaining AF in diverse populations. Randomized trials of FIRM-guided ablation and mechanistic studies to determine how rotors form, progress, and regress are needed.


Assuntos
Fibrilação Atrial/cirurgia , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Registros , Universidades/estatística & dados numéricos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Seguimentos , Sistema de Condução Cardíaco/cirurgia , Humanos , Imageamento Tridimensional , Indiana , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
17.
Am J Cardiol ; 98(10): 1301-6, 2006 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-17134618

RESUMO

Patients with extensive regional wall motion abnormalities are predisposed to development of ventricular tachyarrhythmia. The prognostic effect of this in patients with an implantable cardioverter-defibrillator (ICD) and coronary artery disease (CAD) is not known. Echocardiographic left ventricular systolic indexes, wall motion score index (WMSI), and extent of regional akinesia in 140 patients (65 +/- 10 years old; 92% men) with an ICD and CAD were studied. Arrhythmic events requiring ICD therapy and causing death (n = 41, 29%) were recorded over a mean follow-up of 1.4 +/- 0.8 years. Left ventricular basal fractional shortening, ejection fraction, global WMSI, and extent of akinesia, especially in the inferoposterior regions of a right coronary artery territory, were univariate predictors (all p values <0.05). Global WMSI (hazard ratio 2.18, 95% confidence interval 1.03 to 4.65, p = 0.04) and fractional shortening (hazard ratio 0.93, 95% confidence interval 0.88 to 1.00, p = 0.04) were multivariate predictors. Global WMSI (p = 0.04) and > or =2 right coronary region akinetic segments (p = 0.05) provided incremental risk prediction to left ventricular ejection fraction in a global risk-assessment model (chi-square p = 0.001). Presence of right coronary region akinesia better identified those at increased risk of events (p = 0.02) compared with the presence of left anterior descending region akinesia (p = 0.2), independent of systolic function. In conclusion, global WMSI and left ventricular basal fractional shortening were important additional risk predictors of ICD events in CAD. Global WMSI and right coronary region inferoposterior akinesia provided independent and incremental risk assessment to left ventricular ejection fraction and improved identification of those at increased risk of ICD-related events in patients with ischemic cardiomyopathy.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Isquemia Miocárdica/complicações , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Distribuição de Qui-Quadrado , Doença das Coronárias/complicações , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/fisiopatologia , Ecocardiografia , Feminino , Humanos , Masculino , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Medição de Risco , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia
18.
Cardiol Clin ; 24(3): 439-51, ix-x, 2006 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16939835

RESUMO

A wealth of useful diagnostic criteria is available to assist the health care worker in arriving at the correct diagnosis in cases of a wide QRS tachycardia (WQRST). Despite the abundance of good criteria for determining the diagnosis in cases of WQRST, they are of no use if they cannot be readily applied in an urgent clinical situation because they cannot be easily recalled or are too complex and cumbersome to use. It may be that refresher courses in the differential diagnosis of WQRST, especially for emergency physicians who are often the "first responders" to patients with WQRST, can improve physicians' diagnostic accuracy in this important disorder.


Assuntos
Eletrocardiografia , Taquicardia Ventricular/diagnóstico , Bloqueio de Ramo/diagnóstico , Diagnóstico Diferencial , Humanos , Taquicardia Supraventricular/diagnóstico
19.
Circulation ; 106(22): 2793-9, 2002 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-12451005

RESUMO

BACKGROUND: We previously proposed that adenosine has mechanism-specific effects on atrial tachycardia (AT), such that adenosine terminates AT attributable to triggered activity, transiently suppresses automatic rhythms, and has no effect on macroreentrant AT. This, however, remains controversial, because other studies have reported that adenosine terminates reentrant AT. To clarify this issue, we used 3D electroanatomic mapping to delineate the tachycardia circuit and thereby determine whether the response to adenosine differentiates focal from macroreentrant AT. METHODS AND RESULTS: We examined the effect of adenosine on 43 ATs in 42 consecutive patients (59+/-15 years of age; 26 female) who received adenosine during tachycardia and whose mechanism of AT was characterized by pharmacological perturbation, entrainment, 3D electroanatomic mapping, and results of radiofrequency ablation. Eight tachycardias were macroreentrant (noncavotricuspid isthmus-dependent), and 35 ATs were focal (either triggered or automatic). Adenosine administered during AT (at doses sufficient to result in AV block) terminated or transiently suppressed focal AT in 33 of 35 cases, whereas 8 of 8 macroreentrant ATs were adenosine insensitive (P<0.001). Twenty-eight of 35 focal ATs were located along the crista terminalis or tricuspid annulus. CONCLUSIONS: The response of AT to adenosine can immediately differentiate atrial tachycardia arising from a focal source from that attributable to macroreentry. This finding can be exploited to facilitate developing a focused, strategic ablative approach at the onset of a procedure.


Assuntos
Adenosina , Mapeamento Potencial de Superfície Corporal , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Imageamento Tridimensional , Taquicardia/diagnóstico , Taquicardia/fisiopatologia , Agonistas Adrenérgicos beta/administração & dosagem , Mapeamento Potencial de Superfície Corporal/métodos , Estimulação Cardíaca Artificial , Ablação por Cateter , Diagnóstico Diferencial , Anomalia de Ebstein/diagnóstico , Anomalia de Ebstein/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia/classificação , Taquicardia/cirurgia , Resultado do Tratamento
20.
J Am Coll Cardiol ; 39(12): 1973-83, 2002 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-12084596

RESUMO

OBJECTIVES: The purpose of this study was to define the anatomic distribution of electrically abnormal atrial tissue and mechanisms of atrial tachycardia (AT) after mitral valve (MV) surgery. BACKGROUND: Atrial tachycardia is a well-recognized long-term complication of MV surgery. Because atrial incisions from repair of congenital heart defects provide a substrate for re-entrant arrhythmias in the late postoperative setting, we hypothesized that atriotomies or cannulation sites during MV surgery also contributed to postoperative arrhythmias. METHODS: In 10 patients with prior MV surgery, electroanatomic maps were constructed of 11 tachycardias (6 right atrium [RA], 4 left atrium [LA] and 1 biatrial). Activation and voltage maps were used to identify areas of low voltage, double potentials and conduction block. RESULTS: Lesions were present in the lateral wall of the RA (six of seven maps) and in the LA along the septum adjacent to the right pulmonary veins (four of five maps). In 8 of 10 patients, these findings corresponded to atrial incisions or cannulation sites. Arrhythmia mechanisms were identified for 9 of 11 tachycardias. A macro-re-entrant circuit was mapped in six cases, three involving lesions in the lateral wall of the RA and three involving the LA septum and right pulmonary veins. In three of these cases figure-of-eight re-entry was demonstrated, and in the other three a single macro-re-entrant circuit was observed. In three other cases, a focal origin was identified adjacent to abnormal tissue in the RA (two cases) or within a pulmonary vein (one case). CONCLUSIONS: Surgical incisions for MV surgery provide a substrate for atrial arrhythmias. Both macro-re-entrant and focal mechanisms contribute to AT after MV surgery.


Assuntos
Mapeamento Potencial de Superfície Corporal , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Doenças das Valvas Cardíacas/cirurgia , Valva Mitral/cirurgia , Taquicardia/etiologia , Taquicardia/fisiopatologia , Idoso , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Feminino , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiopatologia , Doenças das Valvas Cardíacas/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA