J Biomech Eng ; 132(8): 081005, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20670054

RESUMO

Characterization of high-intensity focused ultrasound (HIFU) systems using ex vivo tissues is an important part of the preclinical testing for new HIFU devices. In ex vivo characterization, the lesion volume produced by the absorption of HIFU energy is quantified as operational parameters are varied. This paper examines the three methods used for lesion-volume quantification: histology, magnetic resonance (MR) imaging, and numerical calculations. The methods were studied in the context of a clinically relevant problem for HIFU procedures--that of quantifying the change in the lesion volume with changing sonication time. The lesion volumes of sonicated samples of porcine liver were determined using the three methods, at focal intensities ranging from 800 W/cm(2) to 1700 W/cm(2) and sonication times between 20 s and 40 s. It was found that histology consistently yielded lower lesion volumes than the other two methods, and the calculated values were below magnetic resonance imaging (MRI) at high applied energies. Still, the three methods agreed with each other to within a +/-10% difference for all of the experiments. Increasing the sonication time produced much larger changes in the lesion volume than increasing the acoustic intensity, for the same total energy expenditure, at lower energy (less than 1000 J) levels. At higher energy levels, (around 1500 J), increasing the sonication time and increasing the intensity produced roughly the same change in the lesion volume for the same total energy expenditure.


Assuntos
Ablação por Ultrassom Focalizado de Alta Intensidade/métodos , Fígado/patologia , Fígado/cirurgia , Modelos Biológicos , Animais , Simulação por Computador , Relação Dose-Resposta à Radiação , Fígado/efeitos da radiação , Doses de Radiação , Suínos
2.
Ultrasonics ; 51(2): 171-80, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20817250

RESUMO

Experimental studies of thermal effects in high-intensity focused ultrasound (HIFU) procedures are often performed with the aid of fine wire thermocouples positioned within tissue phantoms. Thermocouple measurements are subject to several types of error which must be accounted for before reliable inferences can be made on the basis of the measurements. Thermocouple artifact due to viscous heating is one source of error. A second is the uncertainty regarding the position of the beam relative to the target location or the thermocouple junction, due to the error in positioning the beam at the junction. This paper presents a method for determining the location of the beam relative to a fixed pair of thermocouples. The localization technique reduces the uncertainty introduced by positioning errors associated with very narrow HIFU beams. The technique is presented in the context of an investigation into the effect of blood flow through large vessels on the efficacy of HIFU procedures targeted near the vessel. Application of the beam localization method allowed conclusions regarding the effects of blood flow to be drawn from previously inconclusive (because of localization uncertainties) data. Comparison of the position-adjusted transient temperature profiles for flow rates of 0 and 400ml/min showed that blood flow can reduce temperature elevations by more than 10%, when the HIFU focus is within a 2mm distance from the vessel wall. At acoustic power levels of 17.3 and 24.8W there is a 20- to 70-fold decrease in thermal dose due to the convective cooling effect of blood flow, implying a shrinkage in lesion size. The beam-localization technique also revealed the level of thermocouple artifact as a function of sonication time, providing investigators with an indication of the quality of thermocouple data for a given exposure time. The maximum artifact was found to be double the measured temperature rise, during initial few seconds of sonication.


Assuntos
Terapia por Ultrassom/métodos , Algoritmos , Desenho de Equipamento , Géis , Humanos , Modelos Teóricos , Imagens de Fantasmas , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Temperatura , Transdutores , Terapia por Ultrassom/efeitos adversos