Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
NMR Biomed ; 35(5): e4653, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34816501

RESUMO

Dynamic susceptibility contrast (DSC) MRI is clinically used to measure brain perfusion by monitoring the dynamic passage of a bolus of contrast agent through the brain. For quantitative analysis of the DSC images, the arterial input function is required. It is known that the original assumption of a linear relation between the R2(*) relaxation and the arterial contrast agent concentration is invalid, although the exact relation is as of yet unknown. Studying this relation in vitro is time-consuming, because of the widespread variations in field strengths, MRI sequences, contrast agents, and physiological conditions. This study aims to simulate the R2(*) versus contrast concentration relation under varying physiological and technical conditions using an adapted version of an open-source simulation tool. The approach was validated with previously acquired data in human whole blood at 1.5 T by means of a gradient-echo sequence (proof-of-concept). Subsequently, the impact of hematocrit, field strength, and oxygen saturation on this relation was studied for both gradient-echo and spin-echo sequences. The results show that for both gradient-echo and spin-echo sequences, the relaxivity increases with hematocrit and field strength, while the hematocrit dependency was nonlinear for both types of MRI sequences. By contrast, oxygen saturation has only a minor effect. In conclusion, the simulation setup has proven to be an efficient method to rapidly calibrate and estimate the relation between R2(*) and gadolinium concentration in whole blood. This knowledge will be useful in future clinical work to more accurately retrieve quantitative information on brain perfusion.


Assuntos
Meios de Contraste , Gadolínio DTPA , Hematócrito , Humanos , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos
2.
Magn Reson Med ; 79(3): 1314-1324, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28585234

RESUMO

PURPOSE: To evaluate a prescan-based radiofrequency phase-correction strategy for unbalanced pseudo-continuous arterial spin labeling (pCASL) at 9.4 T in vivo and to test its robustness toward suboptimal shim conditions. METHODS: Label and control interpulse phases were optimized separately by means of two prescans in rats. The mean perfusion as well as the interhemispherical symmetry were measured for several phase combinations (optimized versus theoretical phases) to evaluate the correction quality. Interpulse phases were also optimized under degraded shim conditions (i.e., up to four times the study shim values) to test the strategy's robustness. RESULTS: For all tested shim conditions, the full arterial spin labeling (ASL) signal could be restored. Without any correction, the relative ASL signal was 1.4 ± 1.7%. It increased to 3.6 ± 1.4% with an optimized label phase and to 5.3 ± 1.2% with optimized label and control phases. Moreover, asymmetry between brain hemispheres, which could be as high as 100% without phase optimization, was dramatically reduced to 1 ± 3% when applying optimized label and control phases. CONCLUSIONS: Pseudo-continuous ASL at high magnetic field is very sensitive to shim conditions. Label and control radiofrequency phase optimization based on prescans robustly maximizes the ASL signal obtained with unbalanced pCASL and minimizes the asymmetry between hemispheres. Magn Reson Med 79:1314-1324, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Angiografia por Ressonância Magnética/métodos , Marcadores de Spin , Algoritmos , Animais , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Masculino , Ratos , Ratos Sprague-Dawley
3.
Magn Reson Med ; 77(4): 1656-1664, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27136322

RESUMO

PURPOSE: Arterial spin labeling (ASL) may provide quantitative maps of cerebral blood flow (CBF). Because labeled water exchanges with tissue water, this study evaluates the influence of tissue T1 on CBF quantification using ASL. METHODS: To locally modify T1 , a low dose of manganese (Mn) was intracerebrally injected in one hemisphere of 19 rats (cortex or striatum). Tissue T1 and CBF were mapped using inversion recovery and continuous ASL experiments at 4.7T. RESULTS: Mn reduced the tissue T1 by more than 30% but had little impact on other tissue properties as assessed via dynamic susceptibility and diffusion MRI. Using a single-compartment model, the use of a single tissue T1 value yielded a mean relative ipsilateral (Mn-injected) to contralateral (noninjected) CBF difference of -34% in cortex and -22% in striatum tissue. With a T1 map, these values became -7% and +8%, respectively. CONCLUSION: A low dose of Mn reduces the tissue T1 without modifying CBF. Heterogeneous T1 impacts the ASL estimate of CBF in a region-dependent way. In animals, and when T1 modifications exceed the accuracy with which the tissue T1 can be determined, an estimate of tissue T1 should be obtained when quantifying CBF with an ASL technique. Magn Reson Med 77:1656-1664, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Encéfalo/efeitos dos fármacos , Encéfalo/fisiologia , Circulação Cerebrovascular/fisiologia , Angiografia por Ressonância Magnética/métodos , Manganês/administração & dosagem , Animais , Velocidade do Fluxo Sanguíneo/efeitos dos fármacos , Encéfalo/irrigação sanguínea , Masculino , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Marcadores de Spin
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA